934 resultados para percussion instrument


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A portable self-contained instrument has been designed and developed for the measurement of the Fore and Aft tilt of otter boards within the range —22° to + 22° with an accuracy of ± 1°. An underwater transducer fitted on the otter board converts its tilt into corresponding electrical resistance which is measured in an ohmmeter on board, both being connected by electric cable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study on the nanosecond fiber laser interaction with silicon was performed experimentally for the generation of percussion drilled holes. Single pulse ablation experiments were carried out on mono crystalline 650μm thick Si wafers. Changes of the mass removal mechanism were investigated by varying laser fluence up to 68 J/cm2 and pulse duration from 50 ns to 200 ns. Hole width and depth were measured and surface morphology were studied using scanning electron microscopy (SEM) and optical interferometric profilometry (Veeco NT3300). High speed photography was also used to examine laser generated plasma expansion rates. The material removal rate was found to be influenced by the pulse energy, full pulse duration and pulse peak power. Single pulse ablation depth of 4.42 μm was achieved using a 200 ns pulse of 13.3 J/cm 2, giving a maximum machining efficiency of 31.86 μm per mJ. Holes drilled with an increased fluence but fixed pulse length were deeper, exhibited low recast, but were less efficient than those produced at a lower fluence. The increased peak power in this case led to high levels of plasma and vapour production. The expansion of which, results in a strong driving recoil force, an increase in the rate and volume of melt ejection, and cleaner hole formation. The experimental findings show that for efficient drilling at a given energy, a longer, lower peak power pulse is more desirable than a high peak power short pulse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction phenomena of nanosecond Q-switched diode-pumped solid state (DPSS) laser using 355nm radiation with 0.2mm thick 316L stainless steel foil was investigated at incident laser fluence range of 19 - 82Jcm-2. The characterization study was performed with and without the use of assist gas by utilizing micro supersonic minimum length nozzles (MLN), specifically designed for air at inlet chamber pressure of 8bar. MLN ranged in throat diameters of 200μm, 300μm, and 500μm respectively. Average etch rate per pulse under the influence of three micro supersonic impinging jets, for both oxygen and air showed the average etch rate was reduced when high-speed gas jets were utilized, compared to that without any gas jets, but significant variation was noticed between different jet sizes. Highest etch rate and quality was achieved with the smallest diameter nozzle, suggesting that micro nozzles can produce a viable process route for micro laser cutting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article deals with a draft bill amending the Code of Commercial Companies and the ongoing debate on the planned amendment which includes a proposal to remove a fixed minimum of share capital in limited liability companies. The most important issue under consideration in this paper is the protection of a company’s creditors. The author of the following article, referring to a number of already published statements concerning the draft bill, summarizes the ongoing discussion about the role and the functions of share capital and the proposed new instruments for strengthening creditors’ protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To develop and evaluate the psychometric properties of an instrument for the measurement of self-neglect (SN).Conceptual Framework: An elder self-neglect (ESN) conceptual framework guided the literature review and scale development. The framework has two key dimensions physical/psycho-social and environmental and seven sub dimensions which are representative of the factors that can contribute to intentional and unintentional SN. Methods: A descriptive cross-sectional design was adopted to achieve the research aim. The study was conducted in two phases. Phase 1 involved the development of the questionnaire content and structure. Phase 2 focused on establishing the psychometric properties of the instrument. Content validity was established by a panel of 8 experts and piloted with 9 health and social care professionals. The instrument was subsequently posted with a stamped addressed envelope to 566 health and social care professionals who met specific eligibility criteria across the four HSE areas. A total of 341 questionnaires were returned, a response rate of 60% and 305 (50%) completed responses were included in exploratory factor analysis (EFA). Item and factor analyses were performed to elicit the instruments underlying factor structure and establish preliminary construct validity. Findings: Item and factor analyses resulted in a logically coherent, 37 items, five factor solution, explaining 55.6% of the cumulative variance. The factors were labelled: ‘Environment’, ‘Social Networks’, ‘Emotional and Behavioural Liability’, ‘Health Avoidance’ and ‘Self-Determinism’. The factor loadings were >0.40 for all items on each of the five subscales. Preliminary construct validity was supported by findings. Conclusion: The main outcome of this research is a 37 item Self-Neglect (SN-37) measurement instrument that was developed by EFA and underpinned by an ESN conceptual framework. Preliminary psychometric evaluation of the instrument is promising. Future work should be directed at establishing the construct and criterion related validity of the instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Spirituality is fundamental to all human beings, existing within a person, and developing until death. This research sought to operationalise spirituality in a sample of individuals with chronic illness. A review of the conceptual literature identified three dimensions of spirituality: connectedness, transcendence, and meaning in life. A review of the empirical literature identified one instrument that measures the three dimensions together. Yet, recent appraisals of this instrument highlighted issues with item formulation and limited evidence of reliability and validity. Aim: The aim of this research was to develop a theoretically-grounded instrument to measure spirituality – the Spirituality Instrument-27 (SpI-27). A secondary aim was to psychometrically evaluate this instrument in a sample of individuals with chronic illness (n=249). Methods: A two-phase design was adopted. Phase one consisted of the development of the SpI-27 based on item generation from a concept analysis, a literature review, and an instrument appraisal. The second phase established the psychometric properties of the instrument and included: a qualitative descriptive design to establish content validity; a pilot study to evaluate the mode of administration; and a descriptive correlational design to assess the instrument’s reliability and validity. Data were analysed using SPSS (Version 18). Results: Results of exploratory factor analysis concluded a final five-factor solution with 27 items. These five factors were labelled: Connectedness with Others, Self-Transcendence, Self-Cognisance, Conservationism, and Connectedness with a Higher Power. Cronbach’s alpha coefficients ranged from 0.823 to 0.911 for the five factors, and 0.904 for the overall scale, indicating high internal consistency. Paired-sample t-tests, intra-class correlations, and weighted kappa values supported the temporal stability of the instrument over 2 weeks. A significant positive correlation was found between the SpI-27 and the Spirituality Index of Well-Being, providing evidence for convergent validity. Conclusion: This research addresses a call for a theoretically-grounded instrument to measure spirituality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffuse reflectance spectroscopy with a fiber optic probe is a powerful tool for quantitative tissue characterization and disease diagnosis. Significant systematic errors can arise in the measured reflectance spectra and thus in the derived tissue physiological and morphological parameters due to real-time instrument fluctuations. We demonstrate a novel fiber optic probe with real-time, self-calibration capability that can be used for UV-visible diffuse reflectance spectroscopy in biological tissue in clinical settings. The probe is tested in a number of synthetic liquid phantoms over a wide range of tissue optical properties for significant variations in source intensity fluctuations caused by instrument warm up and day-to-day drift. While the accuracy for extraction of absorber concentrations is comparable to that achieved with the traditional calibration (with a reflectance standard), the accuracy for extraction of reduced scattering coefficients is significantly improved with the self-calibration probe compared to traditional calibration. This technology could be used to achieve instrument-independent diffuse reflectance spectroscopy in vivo and obviate the need for instrument warm up and post∕premeasurement calibration, thus saving up to an hour of precious clinical time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anticoagulation can reduce quality of life, and different models of anticoagulation management might have different impacts on satisfaction with this component of medical care. Yet, to our knowledge, there are no scales measuring quality of life and satisfaction with anticoagulation that can be generalized across different models of anticoagulation management. We describe the development and preliminary validation of such an instrument - the Duke Anticoagulation Satisfaction Scale (DASS). METHODS: The DASS is a 25-item scale addressing the (a) negative impacts of anticoagulation (limitations, hassles and burdens); and (b) positive impacts of anticoagulation (confidence, reassurance, satisfaction). Each item has 7 possible responses. The DASS was administered to 262 patients currently receiving oral anticoagulation. Scales measuring generic quality of life, satisfaction with medical care, and tendency to provide socially desirable responses were also administered. Statistical analysis included assessment of item variability, internal consistency (Cronbach's alpha), scale structure (factor analysis), and correlations between the DASS and demographic variables, clinical characteristics, and scores on the above scales. A follow-up study of 105 additional patients assessed test-retest reliability. RESULTS: 220 subjects answered all items. Ceiling and floor effects were modest, and 25 of the 27 proposed items grouped into 2 factors (positive impacts, negative impacts, this latter factor being potentially subdivided into limitations versus hassles and burdens). Each factor had a high degree of internal consistency (Cronbach's alpha 0.78-0.91). The limitations and hassles factors consistently correlated with the SF-36 scales measuring generic quality of life, while the positive psychological impact scale correlated with age and time on anticoagulation. The intra-class correlation coefficient for test-retest reliability was 0.80. CONCLUSIONS: The DASS has demonstrated reasonable psychometric properties to date. Further validation is ongoing. To the degree that dissatisfaction with anticoagulation leads to decreased adherence, poorer INR control, and poor clinical outcomes, the DASS has the potential to help identify reasons for dissatisfaction (and positive satisfaction), and thus help to develop interventions to break this cycle. As an instrument designed to be applicable across multiple models of anticoagulation management, the DASS could be crucial in the scientific comparison between those models of care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este trabajo se describe una experiencia llevada a cabo con profesores de matemáticas en formación, sobre el papel que pueden desarrollar las nuevas tecnologías para llevar a cabo procesos de demostración y prueba en el aula de secundaria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este trabajo se describe detalladamente una experiencia llevada a cabo con profesores de matemáticas en formación, sobre el papel que pueden desarrollar las nuevas tecnologías para llevar a cabo procesos de demostración y prueba en el aula de secundaria.