943 resultados para pH effect


Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is a g-rowing body of evidence that melatonin and its oxidation product, N-1-acetyl-N-2-formyl-5-methoxykynuramine (AFMK), have anti-inflammatory properties. From a nutritional point of view, the discovery of melatonin in plant tissues emphasizes the importance of its relationship with plant peroxidases. Here we found that the pH of the reaction mixture has a profound influence in the reaction rate and products distribution when melatonin is oxidized by the plant enzyme horseradish peroxidase. At pH 5.5. 1 mm of melatonin was almost completely oxidized within 2 min, whereas only about 3% was consumed at pH 7.4. However, the relative yield of AFMK was higher in physiological pH. Radical-mediated oxidation products, including 2-hydroxymelatonin a dimer of, 2-hydroxymelatonin and O-demethylated dimer of melatonin account for the fast consumption of melatonin at pH 5.5. The higher production of AFMK at pH 7.4 was explained by the involvement of compound III of peroxidases as evidenced by spectral studies. on the other hand, the fast oxidative degradation at pH 5.5 was explained by the classic peroxidase cycle.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the effect of cycling various pH demineralizing solutions on the surface hardness, fluoride release and surface properties of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty specimens of each material were made and the surface hardness measured. The specimens were randomized into five groups according to the pH (4.3; 4.6; 5.0; 5.5 and 6.2) of the demineralizing solution. The specimens were submitted to pH-cycling for 15 days. The specimens remained in the demineralizing solution for six hours and in the remineralizing solution for 18 hours. Then, the surface hardness (SH) was remeasured and the surface properties were assessed. Fluoride release was determined daily. Data from SH and the percentage of alteration in surface hardness were analyzed by analysis of variance (p < 0.05); the Kruskal-Wallis test was performed for the fluoride release results. When hardness was compared, the variation in pH led to a positive correlation for glass ionomer cements and a negative correlation for fluoride release. For polyacid-modified resin composites, a negative correlation was found with regards to fluoride release; no significant correlation was observed for hardness. Surface properties were influenced: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. The pH of the demineralizing solution influenced fluoride release from the tested materials. The pH variation altered hardness and surface properties of glass ionomer cements but did not influence polyacid-modified resin composites.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of a prolonged erosive pH cycling on the superficial microhardness change (SMHC) and the erosive wear of different restorative materials. Eighty enamel specimens with prepared cavities of 1.5 x 1.5 mm were randomly divided into eight groups according to the restorative materials used for the fillings (RMGI - resin-modified glass-ionomer, CGI - conventional glass-ionomer, CR- composite resin, A - amalgam) and immersion media used (ERO - erosive medium or SAL - artificial saliva). During 35 days, half of the specimens were immersed in a cola drink (ERO), for 5 min, three times a day, and they remained in SAL between the erosive cycles. The other half of the specimens was immersed in SAL only, for the entire experimental period (control). Data were tested for significant differences by anova and Tukey's tests (P < 0.05). Scanning electron microscopy images were made to illustrate the enamel erosive wear and restorative materials alterations. The mean SMHC (%) and mean erosive wear (mu m) of the materials were: RMGI-ERO (30/0.5); CGI-ERO (37/0.5); CR-ERO (-0.3/0.3); A-ERO (-4/0.3); RMGI-SAL (4/0.4); CGI-SAL (-6/0.4); CR-SAL (-3/0.2) and A-SAL (2/0.4). Scanning electron microscopy images showed pronounced enamel erosive wear on groups submitted to erosive pH cycling when compared with groups maintained in saliva. In conclusion, the prolonged pH cycling promoted significantly higher alterations (SMHC and erosive wear) on the glass-ionomer cements than the CR and amalgam.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of erosive pH cycling on the percentage of surface micro-hardness change (%SMHC) and wear of different restorative materials and bovine enamel restored with these materials. Eighty enamel specimens were randomly divided into eight groups according to the restorative materials and immersion media used: GI/GV-resin-modifled glass-ionomer, GII/GVI-conventional glass-ionomer, GIII/GVII-resin composite and GIV/GVIII-amalgam. Over a period of seven days, groups GI to GIV were immersed in a cola drink (ERO) for 5 minutes, 3x/day and kept in artificial saliva between erosive cycles. Groups GV to GVIII were immersed in artificial saliva (SAL) throughout the entire experimental period (control). Data were tested for significant differences using ANOVA and Tukey's tests (p < 0.05). For %SMHC, considering the restorative materials, no significant differences were detected among the materials and immersion media. Mean wear was higher for the resin modified glass ionomer cement when compared to conventional cement, but those materials did not significantly differ from the others. For enamel analyses, erosive pH cycling promoted higher wear and %SMHC compared to saliva. There were no significant differences in wear and %SMHC of enamel around the different restorative materials, regardless of the distance from the restorative material (50, 150 or 300 mu m). In conclusion, there were only subtle differences among the materials, and these differences were not able to protect the surrounding enamel from erosion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effects of anaerobic digestion and initial pH on the bioleaching of metals from sewage sludge were investigated in shake flask experiments. A strain of Acidithiobacillus thiooxidans was employed in the assays using secondary and anaerobic sludges, which resulted in similar solubilization yields of the metals chromium, copper, lead, nickel, and zinc for both the sludges investigated. The effect of initial pH (7.0 and 4.0) on metal bioleaching was assayed by using the anaerobic sludge inoculated with indigenous sulfur-oxidizing thiobacilli. Although the time required to reach the end of the experiment (final pH close to 1.0) was shortened at initial pH of 4.0, final metal solubilization was not significantly different for both initial pH values, resulting in higher solubilization yields for copper, nickel, and zinc (higher than 80%). Chromium and lead presented solubilization yields close to 50%. The results obtained in this work showed that the metal bioleaching process can be applied to sewage sludge regardless of the type of sludge and without the requirement of pH adjustment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Sensitive immunologic techniques for the detection of alterations that occur in protein antigens were used to evaluate the immunogenicity of soybean glycinin after isolation, heat denaturation and pH alteration. The objective was to determine the effect of these agents on the immunogenic ability of this protein fraction. Immunologic assays performed on heat-denatured glycinin up to 80 degrees C in the presence of antinative glycinin serum demonstrated that glycinin retains its immunogenic properties. Above 90 degrees C this biological property begins to disappear, with protein insolubilization and epitope modification due to the conformational changes imposed by temperature. A reduction in immunogenicity also occurred when glycinin was taken to pH 2.0 (below its pi) and pH 11.00 (above its pi) and exposed to high temperatures in the presence of native antiglycinin serum. From these data one can conclude that, at extreme pH values, intramolecular reactions may occur which, in combination with the structural disorganization caused by high temperatures, may contribute to the reduction of immunogenicity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: In the present investigation, the anticariogenic effect of fluoride released by two products commonly applied in infants was evaluated. Methods: Bovine sound enamel blocks were randomly allocated to each one of the treatment groups: control (C), varnish (V) and diamine silver fluoride solution (D). The blocks were submitted to pH cycles in an oven at 37°C. Next, surface and cross-sectional microhardness were assessed to calculate the percentage loss of surface microhardness (%SML) and the mineral loss (ΔZ). The fluoride present in enamel was also determined. Results: F/Px10 -3 (ANOVA, p<0.05) in the 1 st layer of enamel before pH-cycling were (C, V and D): 1.61 a; 21.59 b and 3.98 c. The %SMH (Kruskal-Wallis, p<0.05) were: -64.0 a, -45.2 b and -53.1 c. %ΔZ values (ANOVA, p<0.05) were: -18.7 a, -7.7 b and -17.3 a. Conclusion: The data suggested that the fluoride released by varnish showed greater interaction with sound enamel and provided less mineral loss when compared with silver diamine solution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

There is a growing body of evidence that melatonin and its oxidation product, N1-acetyl-N2-formyl-5-methoxykynuramine (AFMK), have anti-inflammatory properties. From a nutritional point of view, the discovery of melatonin in plant tissues emphasizes the importance of its relationship with plant peroxidases. Here we found that the pH of the reaction mixture has a profound influence in the reaction rate and products distribution when melatonin is oxidized by the plant enzyme horseradish peroxidase. At pH 5.5, 1 mm of melatonin was almost completely oxidized within 2 min, whereas only about 3% was consumed at pH 7.4. However, the relative yield of AFMK was higher in physiological pH. Radical-mediated oxidation products, including 2-hydroxymelatonin, a dimer of 2-hydroxymelatonin and O-demethylated dimer of melatonin account for the fast consumption of melatonin at pH 5.5. The higher production of AFMK at pH 7.4 was explained by the involvement of compound III of peroxidases as evidenced by spectral studies. On the other hand, the fast oxidative degradation at pH 5.5 was explained by the classic peroxidase cycle. © 2007 The Authors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the effect of calcium hydroxide on pH changes of the external medium after intracoronal bleaching. Materials and methods: A total of 50 extracted human premolars were prepared and filled with gutta-percha and endodontic sealer. The teeth were randomly divided into five groups according to the bleaching agents employed: (a) Sterile cotton pellet with distilled water (control group); (b) sodium perborate and distilled water; (c) sodium perborate and 10% carbamide peroxide; (d) sodium perborate and 35% hydrogen peroxide; (e) 35% hydrogen peroxide. The teeth were stored in vials containing distilled water and the pH values of the medium surrounding the teeth were analyzed. After 7-day storage, the bleaching agent was removed and replaced by calcium hydroxide, and the distilled water was changed, in which the teeth were kept stored for further 14 days. Measurement of pH of the external medium (distilled water) was performed 7 days after insertion of the bleaching agents, immediately, 7 and 14 days after insertion of the calcium hydroxide. Data were submitted to statistical analysis by the two-way ANOVA and Tukey,s test. Results: There were pH changes of the external medium at 7-day period after bleaching procedures. These results confirmed the diffusion of bleaching agents to the external medium. Conclusion: Calcium hydroxide increased the external medium pH and was effective for pH alkalinization after intracoronal bleaching. Clinical significance: Intracoronal bleaching of endodontically treated teeth may cause cervical root resorption. A possible explanation for this process is the passage of bleaching agents to the periodontal tissues yielding an inflammatory process. In an attempt to keep the neutrality of the periodontal pH, the calcium hydroxide has been recommended.Results of this study showed that this material should be always used after intracoronal bleaching.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The poly(furfuryl alcohol) is highly indicated to obtain advanced carbonaceous materials due mainly to its good carbon yield (around 50%) and a controllable cure reaction. In the processing of some carbonaceous materials, such as monolithic vitreous carbon, it is necessary to make sure that the material has the smallest porosity to be used in nobler applications such as heart valves and aerospace integrated systems. In this manuscript, a design of experiments was used to study the influence of viscosity, pH, and moisture in the porosity of the cured material. This study shows that the moisture exerts a significant influence on the porosity and the trend of the results lead to conclude that lower viscosity and moisture, and the use of non-neutralized poly(furfuryl alcohol) resins lead to obtain materials with better quality. © 2012 Wiley Periodicals, Inc.