983 resultados para operation control
Resumo:
The networking and digitalization of audio equipment has created a need for control protocols. These protocols offer new services to customers and ensure that the equipment operates correctly. The control protocols used in the computer networks are not directly applicable since embedded systems have resource and cost limitations. In this master's thesis the design and implementation of new loudspeaker control network protocols are presented. The protocol stack was required to be reliable, have short response times, configure the network automatically and support the dynamic addition and removal of loudspeakers. The implemented protocol stack was also required to be as efficient and lightweight as possible because the network nodes are fairly simple and lack processing power. The protocol stack was thoroughly tested, validated and verified. The protocols were formally described using LOTOS (Language of Temporal Ordering Specifications) and verified using reachability analysis. A prototype of the loudspeaker network was built and used for testing the operation and the performance of the control protocols. The implemented control protocol stack met the design specifications and proved to be highly reliable and efficient.
Resumo:
Työn tarkoituksena oli analysoida polttoainesauvojen käyttäytymistä Loviisan ydinvoimalaitoksen tehonsäätöajossa. Sähkömarkkinoiden vapautuminen Pohjoismaissa sekä tämän seurauksena vaihteleva sähkön markkinahinta ovat ajaneet sähkötuottajat tilanteeseen, jossa tuotanto aiempaa enemmän mukautuu markkinatilanteeseen. Näin ollen myös Loviisan ydinvoimalaitoksen osallistuminen sähkön tuotannon säätelyyn saattaa tulevaisuudessa olla ajankohtaista. Ennen kuin reaktorin tehonsäätöajoa voidaan alkaa toteuttaa, tulee varmistua siitä, että polttoainesauvassa tehonsäätöjen seurauksena tapahtuvat muutokset eivät aiheuta epäsuotuisia käyttäytymisilmiöitä. Työssä tarkastellaan kahden Loviisan ydinvoimalaitoksen polttoainetoimittajan, British Nuclear Fuels plc:n ja venäläisen TVEL:n ensinippujen polttoainesauvan käyttäytymistä tehonsäätötapauksissa. Työssä tarkastellut tehonsäätötapaukset on pyritty valitsemaan niin, että ne kuvaisivat tulevaisuudessa mahdollisesti toteutettavia tehonsäätöjä. Laskentatapauksien sauvatehohistoriat on generoitu HEXBU-3D sydänsimulaattoriohjelmalla lasketun nelivuotisen perustehohistorian pohjalta lisäämällä säätösauvan aiheuttama reaktoritehon muutos, säätösauvan viereisen polttoainenipun aksiaalitehon muutos sekä säätösauvan rakenteen aiheuttama paikallinen tehopiikki säätösauvan vieressä. Työssä tarkastellaan tehonsäätöjen toteuttamista eri tehotasoille ja vaihtelevilla määrillä tehonsäätösyklejä. Työssä käsitellyt laskentatapaukset on jaoteltu reaktorin ajotavan mukaan seuraavasti: peruskuorma-ajo, viikonloppusäätö ja päiväsäätö. Laskenta suoritettiin ydinpolttoaineen käyttäytymistä kuvaavaa ENIGMA-B 7.3.0 ohjelmaa apuna käyttäen. Laskelmien tulokset osoittavat, että molempien polttoainetoimittajien ensinippujen sauvat kestävät reaktorin tehonsäätöajoa rajoituksetta tarkastelluissa laskentatapauksissa. ENIGMA-ohjelman sisältämät mallit, jotka ennustavat polttoainesauvan suojakuoren vaurioitumistodennäköisyyden jännityskorroosion tai väsymismurtuman kautta, eivät näytä mitään merkkejä vaurioitumisesta. BNFL:n polttoainesauva saavuttaa kuitenkin suurempia väsymismurtumatodennäköisyyden arvoja. Tämä johtuu siitä, että polttoainepelletin ja suojakuoren välinen mekaaninen vuorovaikutus syntyy BNFL:n sauvassa aikaisemmin, joka taas johtaa suurempaan määrään sauvaa rasittavia muodonmuutoksia tehonnostotilanteissa. TVEL:n Zr1%Nb -materiaalista valmistetun suojakuoren käyttäytymistä ei voida kuitenkaan suoraan näiden laskujen perusteella arvioida, sillä ENIGMA-ohjelman mallit perustuvat Zircaloy-suojakuorimateriaaleilla suoritettuihin kokeisiin.
Resumo:
Pysyäkseen kilpailukykyisenä vapautuneilla sähkömarkkinoilla on voimalaitoksen energiantuotantokustannusten oltava mahdollisimman matalia, tinkimättä kuitenkaan korkeasta käytettävyydestä. Polttoaineen energiasisällön mahdollisimman hyvä hyödyntäminen on ratkaisevan tärkeää voimalaitoksen kannattavuudelle. Polttoainekustannusten osuus on konvektiivisilla laitoksilla yleensä yli puolet koko elinjakson kustannuksista. Kun vielä päästörajat tiukkenevat koko ajan, korostuu polttoaineen korkea hyötykäyttö entisestään. Korkea energiantuotannon luotettavuus ja käytettävyys ovat myös elintärkeitä pyrittäessä kustannusten minimointiin. Tässä työssä on käyty läpi voimalaitoksen kustannuksiin vaikuttavia käsitteitä, kuten hyötysuhdetta, käytettävyyttä, polttoaineen hintoja, ylös- ja alasajoja ja tärkeimpiä häviöitä. Ajostrategiassa ja poikkeamien hallinnassa pyritään hyvään hyötysuhteeseen ja alhaisiin päästöihin joka käyttötilanteessa. Lisäksi on tarkasteltu tiettyjen suureiden, eli höyryn lämpötilan ja paineen, savukaasun hapen pitoisuuden, savukaasun loppulämpötilan, sekä lauhduttimen paineen poikkeamien vaikutusta ohjearvostaan energiantuotantokustannuksiin. Happi / hiilimonoksidi optimoinnissa on otettu huomioon myös pohjatuhkan palamattomat.
Resumo:
This thesis presents briefly the basic operation and use of centrifugal pumps and parallel pumping applications. The characteristics of parallel pumping applications are compared to circuitry, in order to search analogy between these technical fields. The purpose of studying circuitry is to find out if common software tools for solving circuit performance could be used to observe parallel pumping applications. The empirical part of the thesis introduces a simulation environment for parallel pumping systems, which is based on circuit components of Matlab Simulink —software. The created simulation environment ensures the observation of variable speed controlled parallel pumping systems in case of different controlling methods. The introduced simulation environment was evaluated by building a simulation model for actual parallel pumping system at Lappeenranta University of Technology. The simulated performance of the parallel pumps was compared to measured values of the actual system. The gathered information shows, that if the initial data of the system and pump perfonnance is adequate, the circuitry based simulation environment can be exploited to observe parallel pumping systems. The introduced simulation environment can represent the actual operation of parallel pumps in reasonably accuracy. There by the circuitry based simulation can be used as a researching tool to develop new controlling ways for parallel pumps.
Resumo:
The interface and software for synchronous control of an autosampler and an electrothermal tungsten coil atomizer in atomic absorption spectrophotometry were developed. The control of the power supply, the trigger of the Read function of the spectrophotometer and the automatic operation of the autosampler was performed by software written in "TurboBasic". The system was evaluated by comparison of the repeatability of peak-height absorbances obtained in the atomization of lead by consecutive 10-µl injections of solutions (prepared in 0.2% v/v HNO3) using autosampler and manual sample introduction, and also by long term operation.
Resumo:
Synchronous machines with an AC converter are used mainly in large drives, for example in ship propulsion drives as well as in rolling mill drives in steel industry. These motors are used because of their high efficiency, high overload capacity and good performance in the field weakening area. Present day drives for electrically excited synchronous motors are equipped with position sensors. Most drives for electrically excited synchronous motors will be equipped with position sensors also in future. This kind of drives with good dynamics are mainly used in metal industry. Drives without a position sensor can be used e.g. in ship propulsion and in large pump and blower drives. Nowadays, these drives are equipped with a position sensor, too. The tendency is to avoid a position sensor if possible, since a sensor reduces the reliability of the drive and increases costs (latter is not very significant for large drives). A new control technique for a synchronous motor drive is a combination of the Direct Flux Linkage Control (DFLC) based on a voltage model and a supervising method (e.g. current model). This combination is called Direct Torque Control method (DTC). In the case of the position sensorless drive, the DTC can be implemented by using other supervising methods that keep the stator flux linkage origin centered. In this thesis, a method for the observation of the drift of the real stator flux linkage in the DTC drive is introduced. It is also shown how this method can be used as a supervising method that keeps the stator flux linkage origin centered in the case of the DTC. In the position sensorless case, a synchronous motor can be started up with the DTC control, when a method for the determination of the initial rotor position presented in this thesis is used. The load characteristics of such a drive are not very good at low rotational speeds. Furthermore, continuous operation at a zero speed and at a low rotational speed is not possible, which is partly due to the problems related to the flux linkage estimate. For operation in a low speed area, a stator current control method based on the DFLC modulator (DMCQ is presented. With the DMCC, it is possible to start up and operate a synchronous motor at a zero speed and at low rotational speeds in general. The DMCC is necessary in situations where high torque (e.g. nominal torque) is required at the starting moment, or if the motor runs several seconds at a zero speed or at a low speed range (up to 2 Hz). The behaviour of the described methods is shown with test results. The test results are presented for the direct flux linkage and torque controlled test drive system with a 14.5 kVA, four pole salient pole synchronous motor with a damper winding and electric excitation. The static accuracy of the drive is verified by measuring the torque in a static load operation, and the dynamics of the drive is proven in load transient tests. The performance of the drive concept presented in this work is sufficient e.g. for ship propulsion and for large pump drives. Furthermore, the developed methods are almost independent of the machine parameters.
Resumo:
This thesis concentrates on studying the operational disturbance behavior of machine tools integrated into FMS. Operational disturbances are short term failures of machine tools which are especially disruptive to unattended or unmanned operation of FMS. The main objective was to examine the effect of operational disturbances on reliability and operation time distribution for machine tools. The theoretical part of the thesis covers the fimdamentals of FMS relating to the subject of this study. The concept of FMS, its benefits and operator's role in FMS operation are reviewed. The importance of reliability is presented. The terms describing the operation time of machine tools are formed by adopting standards and references. The concept of failure and indicators describing reliability and operational performance for machine tools in FMSs are presented. The empirical part of the thesis describes the research methodology which is a combination of automated (ADC) and manual data collection. By using this methodology it is possible to have a complete view of the operation time distribution for studied machine tools. Data collection was carried out in four FMSs consisting of a total of 17 machine tools. Each FMS's basic features and the signals of ADC are described. The indicators describing the reliability and operation time distribution of machine tools were calculated according to collected data. The results showed that operational disturbances have a significant influence on machine tool reliability and operational performance. On average, an operational disturbance occurs every 8,6 hours of operation time and has a down time of 0,53 hours. Operational disturbances cause a 9,4% loss in operation time which is twice the amount of losses caused by technical failures (4,3%). Operational disturbances have a decreasing influence on the utilization rate. A poor operational disturbance behavior decreases the utilization rate. It was found that the features of a part family to be machined and the method technology related to it are defining the operational disturbance behavior of the machine tool. Main causes for operational disturbances were related to material quality variations, tool maintenance, NC program errors, ATC and machine tool control. Operator's role was emphasized. It was found that failure recording activity of the operators correlates with the utilization rate. The more precisely the operators record the failure, the higher is the utilization rate. Also the FMS organizations which record failures more precisely have fewer operational disturbances.
Resumo:
In a previous work, a hybrid system consisting of an advanced oxidation process (AOP) named Photo-Fenton (Ph-F) and a fixed bed biological treatment operating as a sequencing batch biofilm reactor (SBBR) was started-up and optimized to treat 200 mg·L-1 of 4-chlorophenol (4-CP) as a model compound. In this work, studies of reactor stability and control as well as microbial population determination by molecular biology techniques were carried out to further characterize and control the biological reactor. Results revealed that the integrated system was flexible and even able to overcome toxic shock loads. Oxygen uptake rate (OUR) in situ was shown to be a valid tool to control the SBBR operation, to detect toxic conditions to the biomass, and to assess the recovery of performance. A microbial characterization by 16S rDNA sequence analysis reveals that the biological population was varied, although about 30% of the bacteria belonged to the Wautersia genus.
Resumo:
We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.
Resumo:
Un dels problemes típics de regulació en el camp de l’automatització industrial és el control de velocitat lineal d’entrada del fil a les bobines, ja que com més gruix acumulem a igual velocitat de rotació de la bobina s’augmenta notablement la velocitat lineal d’entrada del fil, aquest desajust s’ha de poder compensar de forma automàtica per aconseguir una velocitat d’entrada constant. Aquest problema de regulació de velocitats és molt freqüent i de difícil control a la indústria on intervé el bobinat d’algun tipus de material com cablejat, fil, paper, làmines de planxa, tubs, etc... Els dos reptes i objectius principals són, primer, la regulació de la velocitat de rotació de la bobina per aconseguir una velocitat lineal del fil d’entrada, i segon, mitjançant el guiatge de l’alimentació de fil a la bobina, aconseguir un repartiment uniforme de cada capa de fil. El desenvolupament consisteix amb l’automatització i control d’una bobinadora automàtica mitjançant la configuració i programació de PLC’s, servomotors i encoders. Finalment es farà el muntatge pràctic sobre una bancada per verificar i simular el seu correcte funcionament que ha de donar solució a aquests problemes de regulació de velocitats. Com a conclusions finals s’han aconseguit els objectius i una metodologia per fer una regulació de velocitats de rotació per bobines, amb accionaments de servomotors amb polsos, i a nivell de coneixements he aconseguit dominar les aplicacions d’aquest tipus d’accionaments aplicats a construccions mecàniques.
Resumo:
The RPC Detector Control System (RCS) is the main subject of this PhD work. The project, involving the Lappeenranta University of Technology, the Warsaw University and INFN of Naples, is aimed to integrate the different subsystems for the RPC detector and its trigger chain in order to develop a common framework to control and monitoring the different parts. In this project, I have been strongly involved during the last three years on the hardware and software development, construction and commissioning as main responsible and coordinator. The CMS Resistive Plate Chambers (RPC) system consists of 912 double-gap chambers at its start-up in middle of 2008. A continuous control and monitoring of the detector, the trigger and all the ancillary sub-systems (high voltages, low voltages, environmental, gas, and cooling), is required to achieve the operational stability and reliability of a so large and complex detector and trigger system. Role of the RPC Detector Control System is to monitor the detector conditions and performance, control and monitor all subsystems related to RPC and their electronics and store all the information in a dedicated database, called Condition DB. Therefore the RPC DCS system has to assure the safe and correct operation of the sub-detectors during all CMS life time (more than 10 year), detect abnormal and harmful situations and take protective and automatic actions to minimize consequential damages. The analysis of the requirements and project challenges, the architecture design and its development as well as the calibration and commissioning phases represent themain tasks of the work developed for this PhD thesis. Different technologies, middleware and solutions has been studied and adopted in the design and development of the different components and a big challenging consisted in the integration of these different parts each other and in the general CMS control system and data acquisition framework. Therefore, the RCS installation and commissioning phase as well as its performance and the first results, obtained during the last three years CMS cosmic runs, will be
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
Operation Musketeer, a combined joint Anglo-French operation aimed at regaining control of the Suez Canal in 1956, has received much attention from scholars. The most common approach to the crisis has been to examine the political dimension. The political events that led Prime Minister Anthony Eden’s cabinet to decide to use military force against the wishes of their superior American ally and in the face of American economic pressure and a Soviet threat to attack Paris and London with rockets have been analysed thoroughly. This is particularly the case because the ceasefire and eventual withdrawal were an indisputable defeat of British policy in the Middle East. The military operation not only ruined Prime Minister Eden’s career, but it also diminished the prestige of Britain. It was the beginning of the end, some claim. The British Empire would never be the same. As the consequences of using force are generally considered more important than the military operations themselves, very little attention has been paid to the military planning of Operation Musketeer. The difference between the number of publications on Operation Corporate of the Falklands War and Operation Musketeer is striking. Not only has there been little previous research on the military aspects of Musketeer, the conclusions drawn in the existing works have not reached a consensus. Some historians, such as Correlli Barnett, compare Musketeer to the utter failures of the Tudor landings and Gallipoli. Among significant politicians, Winston Churchill, who had retired from the prime ministership only a year before the Suez Crisis, described the operation as “the most ill-conceived and ill-executed imaginable”. Colin McInnes, a well-known author on British defence policy, represents the middle view when he describes the execution as “far from failure”. Finally, some, like Julian Thompson, the Commander of 3 Commando Brigade during the Falklands War, rate the military action itself as being successful. The interpretation of how successful the handling of the Suez Crisis was from the military point of view depends very much on the approach taken and the areas emphasised in the subject. Frequently, military operations are analysed in isolation from other events. The action of a country’s armed forces is separated from the wider context and evaluated without a solid point of comparison. Political consequences are often used as validated criteria, and complicated factors contributing to military performance are ignored. The lack of comprehensive research on the military action has left room for an analysis concentrating on the military side of the crisis.
Resumo:
The costs of health care are increasing, and at the same time, population is aging. This leads health care organizations to focus more on home based care services. This thesis focuses on the home care organization of the South Karelian District of Social and Health Services (Eksote), which was established in 2010; how its operation is organized and managed, and which problem types are faced in the daily operation of home care. This thesis examines home care services through an extensive interview study, process mapping and statistical data analysis. To be able to understand the nature of services and special environment theory models, such as service management and performance measurement, service processes and service design are introduced. This study is conducted from an external researcher‟s point of view and should be used as a discussion opener. The outcome of this thesis is an upper level development path for Eksote home care. The organization should evaluate and build a service offering, then productize home care services and modularize the products and identify similarities. Service processes should be mapped to generate efficiency for repeating tasks. Units should be reasonably sized and geographically located to facilitate management and operation. All this can be done by recognizing the different types of service products: runners repeaters and strangers. Furthermore, the organization should not hide behind medical issues and should understand the legislative, medical and operational frameworks in health care.
Resumo:
ABSTRACT Statistical process control in mechanized farming is a new way to assess operation quality. In this sense, we aimed to compare three statistical process control tools applied to losses in sugarcane mechanical harvesting to determine the best control chart template for this quality indicator. Losses were daily monitored in farms located within Triângulo Mineiro region, in Minas Gerais state, Brazil. They were carried over a period of 70 days in the 2014 harvest. At the end of the evaluation period, 194 samples were collected in total for each type of loss. The control charts used were individual values chart, moving average and exponentially weighted moving average. The quality indicators assessed during sugarcane harvest were the following loss types: full grinding wheel, stumps, fixed piece, whole cane, chips, loose piece and total losses. The control chart of individual values is the best option for monitoring losses in sugarcane mechanical harvesting, as it is of easier result interpretation, in comparison to the others.