988 resultados para internal R


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Accurately measured peptide masses can be used for large-scale protein identification from bacterial whole-cell digests as an alternative to tandem mass spectrometry (MS/MS) provided mass measurement errors of a few parts-per-million (ppm) are obtained. Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS) routinely achieves such mass accuracy either with internal calibration or by regulating the charge in the analyzer cell. We have developed a novel and automated method for internal calibration of liquid chromatography (LC)/FTICR data from whole-cell digests using peptides in the sample identified by concurrent MS/MS together with ambient polydimethyl-cyclosiloxanes as internal calibrants in the mass spectra. The method reduced mass measurement error from 4.3 +/- 3.7 ppm to 0.3 +/- 2.3 ppm in an E. coli LC/FTICR dataset of 1000 MS and MS/MS spectra and is applicable to all analyses of complex protein digests by FTICRMS. Copyright (c) 2006 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A numerical mesoscale model is used to make a high-resolution simulation of the marine boundary layer in the Persian Gulf, during conditions of offshore flow from Saudi Arabia. A marine internal boundary layer (MIBL) and a sea-breeze circulation (SBC) are found to co-exist. The sea breeze develops in the mid-afternoon, at which time its front is displaced several tens of kilometres offshore. Between the coast and the sea-breeze system, the MIBL that occurs is consistent with a picture described in the existing literature. However, the MIBL is perturbed by the SBC, the boundary layer deepening significantly seaward of the sea-breeze front. Our analysis suggests that this strong, localized deepening is not a direct consequence of frontal uplift, but rather that the immediate cause is the retardation of the prevailing, low-level offshore wind by the SBC. The simulated boundary-layer development can be accounted for by using a simple 1D Lagrangian model of growth driven by the surface heat flux. This model is obtained as a straightforward modification of an established MIBL analytic growth model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we show how a set of recently derived theoretical results for recurrent neural networks can be applied to the production of an internal model control system for a nonlinear plant. The results include determination of the relative order of a recurrent neural network and invertibility of such a network. A closed loop controller is produced without the need to retrain the neural network plant model. Stability of the closed-loop controller is also demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recurrent neural networks can be used for both the identification and control of nonlinear systems. This paper takes a previously derived set of theoretical results about recurrent neural networks and applies them to the task of providing internal model control for a nonlinear plant. Using the theoretical results, we show how an inverse controller can be produced from a neural network model of the plant, without the need to train an additional network to perform the inverse control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research in the late 1980s showed that in many corporate real estates users were not fully aware of the full extent of their property holdings. In many cases, not only was the value of the holdings unknown, but there was uncertainty over the actual extent of ownership within the portfolio. This resulted in a large number of corporate occupiers reviewing their property holdings during the 1990s, initially to create a definitive asset register, but also to benefit from an more efficient use of space. Good management of corporately owned property assets is of equal importance as the management of other principal resources within the company. A comprehensive asset register can be seen as the first step towards a rational property audit. For the effective, efficient and economic delivery of services, it is vital that all property holdings are utilised to the best advantage. This requires that the property provider and the property user are both fully conversant with the value of the property holding and that an asset/internal rent/charge is made accordingly. The advantages of internal rent charging are twofold. Firstly, it requires the occupying department to “contribute” an amount to the business equivalent to the open market rental value of the space that it occupies. This prevents the treating of space as a free good and, as individual profit centres, each department will then rationalise its holdings to minimise its costs. The second advantage is from a strategic viewpoint. By charging an asset rent, the holding department can identify the performance of its real estate holdings. This can then be compared to an internal or external benchmark to help determine whether the company has adopted the most efficient tenure pattern for its properties. This paper investigates the use of internal rents by UK-based corporate businesses and explains internal rents as a form of transfer pricing in the context of management and responsibility accounting. The research finds that the majority of charging organisations introduced internal rents primarily to help calculate true profits at the business unit level. However, less than 10% of the charging organisations introduced internal rents primarily to capture the return on assets within the business. There was also a sizeable element of the market who had no plans to introduce internal rents. Here, it appears that, despite academic and professional views that internal rents are beneficial in improving the efficient use of property, opinion at the business and operational level has not universally accepted this proposition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demands for thermal comfort, better indoor air quality together with lower environmental impacts have had ascending trends in the last decade. In many circumstances, these demands could not be fully covered through the soft approach of bioclimatic design like optimisation of the building orientation and internal layout. This is mostly because of the dense urban environment and building internal energy loads. In such cases, heating, ventilation, air-conditioning and refrigeration (HVAC&R) systems make a key role to fulfill the requirements of indoor environment. Therefore, it is required to select the most proper HVAC&R system. In this study, a robust decision making approach for HVAC&R system selection is proposed. Technical performance, economic aspect and environmental impacts of 36 permutations of primary and secondary systems are taken into account to choose the most proper HVAC&R system for a case study office building. The building is a representative for the dominant form of office buildings in the UK. Dynamic performance evaluation of HVAC&R alternatives using TRNSYS package together with life cycle energy cost analysis provides a reliable basis for decision making. Six scenarios broadly cover the decision makers' attitudes on HVAC&R system selection which are analysed through Analytical Hierarchy Process (AHP). One of the significant outcomes reveals that, despite both the higher energy demand and more investment requirements associated with compound heating, cooling and power system (CCHP); this system is one of the top ranked alternatives due to the lower energy cost and C02 emissions. The sensitivity analysis reveals that in all six scenarios, the first five top ranked alternatives are not changed. Finally, the proposed approach and the results could be used by researchers and designers especially in the early stages of a design process in which all involved bodies face the lack of time, information and tools for evaluation of a variety of systems.