923 resultados para implant frameworks
Resumo:
Microwave assisted synthesis of the Cu(I) compound [Cu(µ4-4-ptz)]n [1, 4-ptz = 5-(4-pyridyl)tetrazolate] has been performed by employing a relatively easy method and within a shorter period of time compared to its sister compounds. The syntheses of the Cu(II) compounds [Cu3(µ3-4-ptz)4(µ2-N3)2(DMF)2]n∙(DMF)2n (2) and [Cu(µ2-4-ptz)2(H2O)2]n (3) using a similar method were reported previously by us. MOFs 1-3 revealed high catalytic activity toward oxidation of cyclic alkanes (cyclopentane, -hexane and -octane) with aqueous hydrogen peroxide, under very mild conditions (at room temperature), without any added solvent or additive. The most efficient system (2/H2O2) showed, for the oxidation of cyclohexane, a turnover number (TON) of 396 (TOF of 40 h−1), with an overall product yield (cyclohexanol and cyclohexanone) of 40% relative to the substrate. Moreover, the heterogeneous catalytic systems 1–3 allowed an easy catalyst recovery and reuse, at least for four consecutive cycles, maintaining ca. 90% of the initial high activity and concomitant high selectivity.
Resumo:
Comunicação apresentada no 38º Congresso Mundial do Instituto Internacional de Sociologia, em Budapeste, Hungria, de 26 a 30 de Junho de 2008.
Resumo:
O objetivo deste trabalho é o desenvolvimento de frameworks de testes automáticos de software. Este tipo de testes normalmente está associado ao modelo evolucionário e às metodologias ágeis de desenvolvimento de software, enquanto que os testes manuais estão relacionados com o modelo em cascata e as metodologias tradicionais. Como tal foi efetuado um estudo comparativo sobre os tipos de metodologias e de testes existentes, para decidir quais os que melhor se adequavam ao projeto e dar resposta à questão "Será que realmente compensa realizar testes (automáticos)?". Finalizado o estudo foram desenvolvidas duas frameworks, a primeira para a implementação de testes funcionais e unitários sem dependências a ser utilizada pelos estagiários curriculares da LabOrders, e a segunda para a implementação de testes unitários com dependências externas de base de dados e serviços, a ser utilizada pelos funcionários da empresa. Nas últimas duas décadas as metodologias ágeis de desenvolvimento de software não pararam de evoluir, no entanto as ferramentas de automação não conseguiram acompanhar este progresso. Muitas áreas não são abrangidas pelos testes e por isso alguns têm de ser feitos manualmente. Posto isto foram criadas várias funcionalidades inovadoras para aumentar a cobertura dos testes e tornar as frameworks o mais intuitivas possível, nomeadamente: 1. Download automático de ficheiros através do Internet Explorer 9 (e versões mais recentes). 2. Análise do conteúdo de ficheiros .pdf (através dos testes). 3. Obtenção de elementos web e respetivos atributos através de código jQuery utilizando a API WebDriver com PHP bindings. 4. Exibição de mensagens de erro personalizadas quando não é possível encontrar um determinado elemento. As frameworks implementadas estão também preparadas para a criação de outros testes (de carga, integração, regressão) que possam vir a ser necessários no futuro. Foram testadas em contexto de trabalho pelos colaboradores e clientes da empresa onde foi realizado o projeto de mestrado e os resultados permitiram concluir que a adoção de uma metodologia de desenvolvimento de software com testes automáticos pode aumentar a produtividade, reduzir as falhas e potenciar o cumprimento de orçamentos e prazos dos projetos das organizações.
Resumo:
Disserta ção apresentada para obten ção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Os sistemas de informação integrados contribuem para a gestão eficiente das empresas, seja na organização e funcionamento internos ou nas relações externas. O mercado deste software é dominado pelas empresas que criam e distribuem sistemas proprietários. Existe uma alternativa, software livre, que disponibiliza aplicações em código aberto e maioritariamente de licença gratuita, que pode ser adaptado às necessidades das empresas. O objetivo do presente trabalho é avaliar a viabilidade de plataformas livres, de natureza vertical – OFBiz – e horizontal – Spring – como opção na escolha de um sistema de informação nas Pequenas e Médias Empresas portuguesas. Das áreas de negócio principais das organizações, foi selecionada a área de Recursos Humanos para efeitos de adaptação na aplicação OFBiz, com incidência em dois casos de uso: uma opção essencial, mas que atualmente não está prevista – Processamento de vencimentos – e outra já existente e que é avaliada em termos de necessidades de adaptação – Recrutamento. Sendo o idioma um requisito indispensável à internacionalização da aplicação, foi também analisada a sua implementação. A metodologia de investigação utilizada foi o Design Science Research, tendo sido implementado um protótipo para efeitos de teste e avaliação do projeto, com a elaboração de dois modelos: configuração e desenvolvimento. Implementado o protótipo, verificou-se que a framework vertical apresenta-se como uma alternativa mais viável do que a horizontal, pelas funcionalidades já existentes e que facilitam a adequação às necessidades de informação das Pequenas e Médias Empresas. A sua base tecnológica e de estrutura permite que a aplicação possa ser adaptada por técnicos especialistas das próprias empresas.
Resumo:
This report describes a study based on a research and evaluation of platforms (JavaScript frameworks and libraries carried out under the discipline of Tese/Dissertação/Estágio in the Master Degree Computer Science - area of expertise in Arquitecturas Sistemas e Redes, in Instituto Superior de Engenharia do Porto (ISEP). The JavaScript language is increasingly present in the development of software and particularly software for the web environment. For this reason there is a need to investigate the issue, as the platforms that are emerging in the market have a very low level of maturity compared to existing, it is crucial to identify the main differences so that we can save time, labor and other costs in research and experimentation developers. This project aims to inform a range of platforms and existing JavaScript libraries on the market. For further investigation, a study of use cases used at this point in the market was held. To assist the work were used qualitative research methods through the existing content of research related to the area, and quantitative research methods. It was thus conducted a survey sent via email to fifty regular users of the language, platforms, and JavaScript libraries, linking the functional and non-functional characteristics of the platforms and existing use cases in the market, in order to realize what is the use of these tools in his professional life. This study allowed developers to access information that will be compared and evaluated in order to achieve a more precise evaluation of the various analyzed platforms. It was also made an evaluation of adaptation of the various platforms to the various use cases.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Diabetic macular oedema (DMO) is a leading cause of vision loss in the working-age population worldwide. Corticosteroid drugs have been demonstrated to inhibit the expression of both the vascular endothelial growth factor (VEGF) gene and other anti-inflammatory mediators, such as prostaglandins. Triamcinolone, fluocinolone and dexamethasone are the main steroids that have been studied for the treatment of macular oedema. Over the last few years, several studies have suggested an important role for dexamethasone in the management of DMO. The dexamethasone intravitreal implant (DEX implant) (Ozurdex®; Allergan, Inc., Irvine, CA) is a novel approach approved by the US Food and Drug Administration (FDA) and by the EU for the intravitreal treatment of macular oedema after branch or central retinal vein occlusion, and for the treatment of non-infectious uveitis affecting the posterior segment of the eye. We reviewed manuscripts that had investigated the pharmacokinetics, efficacy and safety of the DEX implant regarding DMO treatment.
Resumo:
Nexplanon (Schering-Plough Limited/Merck Sharp & Dohme Limited (MSD)) is a long active reversible contraceptive method that provides effective contraception for 3 years. It consists of a single, flexible, rod-shaped implant, containing 68 mg etonogestrel. It is 4 cm long, consists of an ethylene vinyl acetate copolymer, a non-absorbable material, and also contains 15 mg of barium sulfate, which makes it visible by X-ray. We describe a case of a 39-year-old woman who experienced a local reaction to the barium sulfate in Nexplanon. She was given medical treatment, but only the removal of the implant resolved the symptoms. After removal there was gradual improvement and 72 h later the patient was asymptomatic. Allergic reaction to barium sulfate is extremely rare: until now, there have only been two cases associated with Nexplanon described in the literature.
Resumo:
Background Several studies link the seamless fit of implant-supported prosthesis with the accuracy of the dental impression technique obtained during acquisition. In addition, factors such as implant angulation and coping shape contribute to implant misfit. Purpose To identify the most accurate impression technique and factors affecting the impression accuracy. Material and Methods A systematic review of peer-reviewed literature was conducted analyzing articles published between 2009 and 2013. The following search terms were used: implant impression, impression accuracy, and implant misfit. A total of 417 articles was identified, 32 were selected for review. Results All 32 selected studies refer to in vitro studies. Fourteen articles compare open and closed impression technique, 8 advocate the open technique and 6 report similar results. Other 14 articles evaluate splinted and non-splinted techniques; all advocating the splinted technique. Polyether material usage was reported in 9; 6 studies tested vinyl polysiloane and 1 study used irreversible hydrocolloid. Eight studies evaluated different copings designs. Intra-oral optical devices were compared in 4 studies. Conclusions The most accurate results were achieved with two configurations: (1) the optical intra-oral system with powder; and (2) the open technique with splinted squared transfer copings, using polyether as impression material.
Resumo:
Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação
Resumo:
Infections associated with implants are increasingly important in modem medicine. Biofilms are the cause that these infections are more difficult to diagnose and to cure. Particularly low-grade infections are difficult to distinguish from aseptic failure, because they often present with early loosening and persisting pain. For an accurate diagnosis, clinical signs and symptoms, laboratory markers of infection, microbiology, histology and imaging examinations are needed. The treatment goal is eradication of infection and an optimal functional result. Successful treatment requires adequate surgical procedure combined with long-term antimicrobial therapy, ideally with an agent acting on biofilms.
Resumo:
BACKGROUND: The aim of this study was to evaluate the mid-term biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. METHODS: Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. IOP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. RESULTS: For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. CONCLUSIONS: The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.