915 resultados para hardware abstraction layer
Resumo:
Nowadays despite improvements in usability and intuitiveness users have to adapt to the proposed systems to satisfy their needs. For instance, they must learn how to achieve tasks, how to interact with the system, and fulfill system's specifications. This paper proposes an approach to improve this situation enabling graphical user interface redefinition through virtualization and computer vision with the aim of increasing the system's usability. To achieve this goal the approach is based on enriched task models, virtualization and picture-driven computing.
Resumo:
Os sistemas de redes de campo ligando componentes de automação e máquinas possuem uma performance muito elevada, relativamente à sua velocidade e capacidade de funcionamento em tempo-real. Estes apresentam também uma variedade de funcionalidades tais como comunicação cruzada, protocolos de segurança e endereçamento automático. Além disso, definem também aproximações lógicas ao tipo de máquinas em questão, de acordo com o seu perfil de funcionamento. No entanto, todas estas funcionalidades tornam a configuração e programação de aplicações comunicando nestas redes de campo extremamente complexa. Para além da complexidade existente na configuração e programação de um único sistema de redes de campo, existe também uma panóplia de diferentes sistemas de redes de campo, totalmente incompatíveis entre si. Contudo, estes pouco se diferenciam relativamente às suas funcionalidades e performance. Neste trabalho é elaborada uma comparação entre 4 diferentes perfis de accionamentos (CiA 402, CIP Motion, FSP Drive e PROFIdrive) para sistemas de redes de campo baseados em Ethernet (Ethercat, Ethernet/IP, PROFInet e SERCOS. Com este resultado, o acesso aos diferentes sistemas de redes de campo poderá ser generalizado, de forma que a aplicação a desenvolver seja independente do sistema localizado nas camadas OSI inferiores.
Resumo:
Este trabalho sugere uma solução de integração de dados em tempo real no contexto dos transportes públicos. Com o aumento das alternativas oferecidas aos utilizadores dos transportes públicos é importante que estes conheçam todas as alternativas com base em informação em tempo real para que realizem a escolha que melhor se enquadre às suas necessidades. Por outro lado, os operadores de transportes públicos deverão ser capazes de disponibilizar toda a informação pretendida com o mínimo de esforço ou de alterações ao sistema que têm implementado. Neste trabalho serão utilizadas ferramentas que permitem fornecer uma visão homogénea das várias fontes de dados heterogéneas, sendo essa homogeneidade o ponto de integração de todas as fontes de dados com as aplicações cliente.
Resumo:
We report on structural, electronic, and optical properties of boron-doped, hydrogenated nanocrystalline silicon (nc-Si:H) thin films deposited by plasma-enhanced chemical vapor deposition (PECVD) at a substrate temperature of 150 degrees C. Film properties were studied as a function of trimethylboron-to-silane ratio and film thickness. The absorption loss of 25% at a wavelength of 400 nm was measured for the 20 nm thick films on glass and glass/ZnO:Al substrates. By employing the p(+) nc-Si:H as a window layer, complete p-i-n structures were fabricated and characterized. Low leakage current and enhanced sensitivity in the UV/blue range were achieved by incorporating an a-SiC:H buffer between the p- and i-layers.
Resumo:
Characteristics of tunable wavelength filters based on a-SiC:H multi-layered stacked cells are studied both theoretically and experimentally. Results show that the light-activated photonic device combines the demultiplexing operation with the simultaneous photodetection and self amplification of an optical signal. The sensor is a bias wavelength current-controlled device that make use of changes in the wavelength of the background to control the power delivered to the load, acting a photonic active filter. Its gain depends on the background wavelength that controls the electrical field profile across the device.
Resumo:
Since the last decade research in Group Decision Making area have been focus in the building of meeting rooms that could support the decision making task and improve the quality of those decisions. However the emergence of Ambient Intelligence concept contributes with a new perspective, a different way of viewing traditional decision rooms. In this paper we will present an overview of Smart Decision Rooms providing Intelligence to the meeting environment, and we will also present LAID, an Ambient Intelligence Environment oriented to support Group Decision Making and some of the software tools that we already have installed in this environment.
Resumo:
Titanium films have been deposited on stainless steel metal sheets using dc magnetron sputtering technique at different substrate temperatures. The structure of the titanium films strongly depend on the substrate temperature. The titanium film deposited at the substrate temperature lower than 300 ◦C has a loose flat sheet grains structure and the titanium film prepared at the substrate temperature higher than 500 ◦C has a dense nubby grains structure. The DSSC assembled using stainless steel sheet coated with titanium film deposited at high substrate temperature has a low charge transfer resistance in the TiO2/Ti interface and results in a high conversion efficiency. The DSSC assembled using stainless steel sheet coated with titanium film deposited at temperature higher than 500 ◦C has higher conversion efficiency than that assembled using titanium metal sheet as the substrate. The maximum conversion efficiency, 2.26% is obtained for DSSC assembled using stainless steel sheet coated with titanium film deposited at 700 ◦C substrate temperature, which is about 70% of the conversion efficiency of the FTO reference cell used in this study.
Resumo:
: In this work we derive an analytical solution given by Bessel series to the transient and one-dimensional (1D) bioheat transfer equation in a multi-layer region with spatially dependent heat sources. Each region represents an independent biological tissue characterized by temperature-invariant physiological parameters and a linearly temperature dependent metabolic heat generation. Moreover, 1D Cartesian, cylindrical or spherical coordinates are used to define the geometry and temperature boundary conditions of first, second and third kinds are assumed at the inner and outer surfaces. We present two examples of clinical applications for the developed solution. In the first one, we investigate two different heat source terms to simulate the heating in a tumor and its surrounding tissue, induced during a magnetic fluid hyperthermia technique used for cancer treatment. To obtain an accurate analytical solution, we determine the error associated with the truncated Bessel series that defines the transient solution. In the second application, we explore the potential of this model to study the effect of different environmental conditions in a multi-layered human head model (brain, bone and scalp). The convective heat transfer effect of a large blood vessel located inside the brain is also investigated. The results are further compared with a numerical solution obtained by the Finite Element Method and computed with COMSOL Multi-physics v4.1 (c). (c) 2013 Elsevier Ltd. All rights reserved.
Resumo:
We report within this paper the development of a fiber-optic based sensor for Hg(II) ions. Fluorescent carbon nanoparticles were synthesized by laser ablation and functionalized with PEG200 and N-acetyl-l-cysteine so they can be anionic in nature. This characteristic facilitated their deposition by the layer-by-layer assembly method into thin alternating films along with a cationic polyelectrolyte, poly(ethyleneimine). Such films could be immobilized onto the tip of a glass optical fiber, allowing the construction of an optical fluorescence sensor. When immobilized on the fiber-optic tip, the resultant sensor was capable of selectively detecting sub-micromolar concentrations of Hg(II) with an increased sensitivity compared to carbon dot solutions. The fluorescence of the carbon dots was quenched by up to 44% by Hg(II) ions and interference from other metal ions was minimal.
Resumo:
We present measurements and numerical simulation of a-Si:H p-i-n detectors with a wide range of intrinsic layer thickness between 2 and 10 pm. Such a large active layer thickness is required in applications like elementary particle detectors or X-ray detectors. For large thickness and depending on the applied bias, we observe a sharp peak in the spectral response in the red region near 700 nm. Simulation results obtained with the program ASCA are in agreement with the measurement and permit the explanation of the experimental data. In thick samples holes recombine or are trapped before reaching the contacts, and the conduction mechanism is fully electron dominated. As a consequence, the peak position in the spectral response is located near the optical band gap of the a-Si:H i-layer. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Introduction: Paper and thin layer chromatography methods are frequently used in Classic Nuclear Medicine for the determination of radiochemical purity (RCP) on radiopharmaceutical preparations. An aliquot of the radiopharmaceutical to be tested is spotted at the origin of a chromatographic strip (stationary phase), which in turn is placed in a chromatographic chamber in order to separate and quantify radiochemical species present in the radiopharmaceutical preparation. There are several methods for the RCP measurement, based on the use of equipment as dose calibrators, well scintillation counters, radiochromatografic scanners and gamma cameras. The purpose of this study was to compare these quantification methods for the determination of RCP. Material and Methods: 99mTc-Tetrofosmin and 99mTc-HDP are the radiopharmaceuticals chosen to serve as the basis for this study. For the determination of RCP of 99mTc-Tetrofosmin we used ITLC-SG (2.5 x 10 cm) and 2-butanone (99mTc-tetrofosmin Rf = 0.55, 99mTcO4- Rf = 1.0, other labeled impurities 99mTc-RH RF = 0.0). For the determination of RCP of 99mTc-HDP, Whatman 31ET and acetone was used (99mTc-HDP Rf = 0.0, 99mTcO4- Rf = 1.0, other labeled impurities RF = 0.0). After the development of the solvent front, the strips were allowed to dry and then imaged on the gamma camera (256x256 matrix; zoom 2; LEHR parallel-hole collimator; 5-minute image) and on the radiochromatogram scanner. Then, strips were cut in Rf 0.8 in the case of 99mTc-tetrofosmin and Rf 0.5 in the case of 99mTc-HDP. The resultant pieces were smashed in an assay tube (to minimize the effect of counting geometry) and counted in the dose calibrator and in the well scintillation counter (during 1 minute). The RCP was calculated using the formula: % 99mTc-Complex = [(99mTc-Complex) / (Total amount of 99mTc-labeled species)] x 100. Statistical analysis was done using the test of hypotheses for the difference between means in independent samples. Results:The gamma camera based method demonstrated higher operator-dependency (especially concerning the drawing of the ROIs) and the measures obtained using the dose calibrator are very sensitive to the amount of activity spotted in the chromatographic strip, so the use of a minimum of 3.7 MBq activity is essential to minimize quantification errors. Radiochromatographic scanner and well scintillation counter showed concordant results and demonstrated the higher level of precision. Conclusions: Radiochromatographic scanners and well scintillation counters based methods demonstrate to be the most accurate and less operator-dependant methods.
Resumo:
Para dar resposta aos grandes avanços tecnológicos e, consequentemente, à postura mais exigente dos clientes, a empresa Francisco Parracho – Electrónica Industrial, Lda., que tem actividade no ramo dos elevadores, decidiu introduzir no mercado um controlador dedicado de ecrãs Liquid Crystal Display / Thin Film Transistor (LCD / TFT). O objectivo é substituir um sistema suportado por um computador, caracterizado pelas suas elevadas dimensões e custos, mas incontornável até à data, nomeadamente para resoluções de ecrã elevadas. E assim nasceu este trabalho. Com uma selecção criteriosa de todos os componentes e, principalmente, sem funcionalidades inúteis, obteve-se um sistema embebido com dimensões e custos bem mais reduzidos face ao seu opositor. O ecrã apontado para este projecto é um Thin Film Transistor – Liquid Crystal Display (TFT-LCD) da Sharp de 10.4” de qualidade industrial, com uma resolução de 800 x 600 píxeis a 18 bits por píxel. Para tal, foi escolhido um micro-controlador da ATMEL, um AVR de 32 bits que, entre outras características, possui um controlador LCD que suporta resoluções até 2048 x 2048 píxeis, de 1 a 24 bits por píxel. Atendendo ao facto deste produto ser inserido na área dos elevadores, as funcionalidades, quer a nível do hardware quer a nível do software, foram projectadas para este âmbito. Contudo, o conceito aqui exposto é adjacente a quaisquer outras áreas onde este produto se possa aplicar, até porque o software está feito para se tornar bem flexível. Com a ajuda de um kit de desenvolvimento, foram validados os drivers dos controladores e periféricos base deste projecto. De seguida, aplicou-se esse software numa placa de circuito impresso, elaborada no âmbito deste trabalho, para que fossem cumpridos todos os requisitos requeridos pela empresa patrocinadora: - Apresentação de imagens no ecrã consoante o piso; - Possibilidade de ter um texto horizontalmente deslizante;Indicação animada do sentido do elevador; - Representação do piso com deslizamento vertical; - Descrição sumária do directório de pisos também com deslizamento vertical; - Relógio digital; - Leitura dos conteúdos pretendidos através de um cartão SD/MMC; - Possibilidade de actualização dos conteúdos via USB flash drive.
Resumo:
A crescente complexidade dos sistemas electrónicos associada a um desenvolvimento nas tecnologias de encapsulamento levou à miniaturização dos circuitos integrados, provocando dificuldades e limitações no diagnóstico e detecção de falhas, diminuindo drasticamente a aplicabilidade dos equipamentos ICT. Como forma de lidar com este problema surgiu a infra-estrutura Boundary Scan descrita na norma IEEE1149.1 “Test Access Port and Boundary-Scan Architecture”, aprovada em 1990. Sendo esta solução tecnicamente viável e interessante economicamente para o diagnóstico de defeitos, efectua também outras aplicações. O SVF surgiu do desejo de incutir e fazer com que os fornecedores independentes incluíssem a norma IEEE 1149.1, é desenvolvido num formato ASCII, com o objectivo de enviar sinais, aguardar pela sua resposta, segundo a máscara de dados baseada na norma IEEE1149.1. Actualmente a incorporação do Boundary Scan nos circuitos integrados está em grande expansão e consequentemente usufrui de uma forte implementação no mercado. Neste contexto o objectivo da dissertação é o desenvolvimento de um controlador boundary scan que implemente uma interface com o PC e possibilite o controlo e monitorização da aplicação de teste ao PCB. A arquitectura do controlador desenvolvido contém um módulo de Memória de entrada, um Controlador TAP e uma Memória de saída. A implementação do controlador foi feita através da utilização de uma FPGA, é um dispositivo lógico reconfiguráveis constituído por blocos lógicos e por uma rede de interligações, ambos configuráveis, que permitem ao utilizador implementar as mais variadas funções digitais. A utilização de uma FPGA tem a vantagem de permitir a versatilidade do controlador, facilidade na alteração do seu código e possibilidade de inserir mais controladores dentro da FPGA. Foi desenvolvido o protocolo de comunicação e sincronização entre os vários módulos, permitindo o controlo e monitorização dos estímulos enviados e recebidos ao PCB, executados automaticamente através do software do Controlador TAP e de acordo com a norma IEEE 1149.1. A solução proposta foi validada por simulação utilizando o simulador da Xilinx. Foram analisados todos os sinais que constituem o controlador e verificado o correcto funcionamento de todos os seus módulos. Esta solução executa todas as sequências pretendidas e necessárias (envio de estímulos) à realização dos testes ao PCB. Recebe e armazena os dados obtidos, enviando-os posteriormente para a memória de saída. A execução do trabalho permitiu concluir que os projectos de componentes electrónicos tenderão a ser descritos num nível de abstracção mais elevado, recorrendo cada vez mais ao uso de linguagens de hardware, no qual o VHDL é uma excelente ferramenta de programação. O controlador desenvolvido será uma ferramenta bastante útil e versátil para o teste de PCBs e outras funcionalidades disponibilizadas pelas infra-estruturas BS.
Resumo:
Conferência: 39th Annual Conference of the IEEE Industrial-Electronics-Society (IECON), Vienna, Austria, Nov 10-14, 2013
Resumo:
Relatório do Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações