955 resultados para gold standard
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
Background: With the decrease of DNA sequencing costs, sequence-based typing methods are rapidly becoming the gold standard for epidemiological surveillance. These methods provide reproducible and comparable results needed for a global scale bacterial population analysis, while retaining their usefulness for local epidemiological surveys. Online databases that collect the generated allelic profiles and associated epidemiological data are available but this wealth of data remains underused and are frequently poorly annotated since no user-friendly tool exists to analyze and explore it. Results: PHYLOViZ is platform independent Java software that allows the integrated analysis of sequence-based typing methods, including SNP data generated from whole genome sequence approaches, and associated epidemiological data. goeBURST and its Minimum Spanning Tree expansion are used for visualizing the possible evolutionary relationships between isolates. The results can be displayed as an annotated graph overlaying the query results of any other epidemiological data available. Conclusions: PHYLOViZ is a user-friendly software that allows the combined analysis of multiple data sources for microbial epidemiological and population studies. It is freely available at http://www.phyloviz.net.
Resumo:
Introdução – A mamografia é o principal método de diagnóstico por imagem utilizado no rastreio e diagnóstico do cancro da mama, sendo a modalidade de imagem recomendada em vários países da Europa e Estados Unidos para utilização em programas de rastreio. A implementação da tecnologia digital causou alterações na prática da mamografia, nomeadamente a necessidade de adaptar os programas de controlo de qualidade. Objetivos – Caracterizar a tecnologia instalada para mamografia em Portugal e as práticas adotadas na sua utilização pelos profissionais de saúde envolvidos. Concluir sobre o nível de harmonização das práticas em mamografia em Portugal e a conformidade com as recomendações internacionais. Identificar oportunidades para otimização que permitam assegurar a utilização eficaz e segura da tecnologia. Metodologia – Pesquisa e recolha de dados sobre a tecnologia instalada, fornecidos por fontes governamentais, prestadores de serviços de mamografia e indústria. Construção de três questionários, orientados ao perfil do médico radiologista, técnico de radiologia com atividade em mamografia digital e técnico de radiologia coordenador. Os questionários foram aplicados em 65 prestadores de serviços de mamografia selecionados com base em critérios de localização geográfica, tipo de tecnologia instalada e perfil da instituição. Resultados – Foram identificados 441 sistemas para mamografia em Portugal. A tecnologia mais frequente (62%) e vulgarmente conhecida por radiografia computorizada (computed radiography) é constituída por um detector (image plate) de material fotoestimulável inserido numa cassete de suporte e por um sistema de processamento ótico. A maioria destes sistemas (78%) está instalada em prestadores privados. Aproximadamente 12% dos equipamentos instalados são sistemas para radiografia digital direta (Direct Digital Radiography – DDR). Os critérios para seleção dos parâmetros técnicos de exposição variam, observando-se que em 65% das instituições são adotadas as recomendações dos fabricantes do equipamento. As ferramentas de pós-processamento mais usadas pelos médicos radiologistas são o ajuste do contraste e brilho e magnificação total e/ou localizada da imagem. Quinze instituições (em 19) têm implementado um programa de controlo de qualidade. Conclusões – Portugal apresenta um parque de equipamentos heterogéneo que inclui tecnologia obsoleta e tecnologia “topo de gama”. As recomendações/guidelines (europeias ou americanas) não são adotadas formalmente na maioria das instituições como guia para fundamentação das práticas em mamografia, dominando as recomendações dos fabricantes do equipamento. Foram identificadas, pelos técnicos de radiologia e médicos radiologistas, carências de formação especializada, nomeadamente nas temáticas da intervenção mamária, otimização da dose e controlo da qualidade. A maioria dos inquiridos concorda com a necessidade de certificação da prática da mamografia em Portugal e participaria num programa voluntário. ABSTRACT - Introduction – Mammography is the gold standard for screening and imaging diagnosis of breast disease. It is the imaging modality recommended by screening programs in various countries in Europe and the United States. The implementation of the digital technology promoted changes in mammography practice and triggered the need to adjust quality control programs. Aims –Characterize the technology for mammography installed in Portugal. Assess practice in use in mammography and its harmonization and compliance to international guidelines. Identify optimization needs to promote an effective and efficient use of digital mammography to full potential. Methodology – Literature review was performed. Data was collected from official sources (governmental bodies, mammography healthcare providers and medical imaging industry) regarding the number and specifications of mammography equipment installed in Portugal. Three questionnaires targeted at radiologists, breast radiographers and the chief-radiographer were designed for data collection on the technical and clinical practices in mammography. The questionnaires were delivered in a sample of 65 mammography providers selected according to geographical criteria, type of technology and institution profile. Results – Results revealed 441 mammography systems installed in Portugal. The most frequent (62%) technology type are computerized systems (CR) mostly installed in the private sector (78%). 12% are direct radiography systems (DDR). The criteria for selection of the exposure parameters differ between the institutions with the majority (65%) following the recommendations from the manufacturers. The use of available tools for post-processing is limited being the most frequently reported tools used the contrast/ brightness and Zoom or Pan Magnification tools. Fifteen participant institutions (out of 19) have implemented a quality control programme. Conclusions – The technology for mammography in Portugal is heterogeneous and includes both obsolete and state of the art equipment. International guidelines (European or American) are not formally implemented and the manufacturer recommendations are the most frequently used guidance. Education and training needs were identified amongst the healthcare professionals (radiologists and radiographers) with focus in the areas of mammography intervention, patient dose optimization and quality control. The majority of the participants agree with the certification of mammography in Portugal.
Resumo:
OBJECTIVE: To evaluate the discriminative and diagnostic values of neuropsychological tests for identifying schizophrenia patients. METHODS: A cross-sectional study with 36 male schizophrenia outpatients and 72 healthy matched volunteers was carried out. Participants underwent the following neuropsychological tests: Wisconsin Card Sorting test, Verbal Fluency, Stroop test, Mini Mental State Examination, and Spatial Recognition Span. Sensitivity and specificity estimated the diagnostic value of tests with cutoffs obtained using Receiver Operating Characteristic curves. The latent class model (diagnosis of schizophrenia) was used as gold standard. RESULTS: Although patients presented lower scores in most tests, the highest canonical function for the discriminant analysis was 0.57 (Verbal Fluency M). The best sensitivity and specificity were obtained in the Verbal Fluency M test (75 and 65, respectively). CONCLUSIONS: The neuropsychological tests showed moderate diagnostic value for the identification of schizophrenia patients. These findings suggested that the cognitive impairment measured by these tests might not be homogeneous among schizophrenia patients.
Resumo:
Levels of risk for future disability can be assessed with grip strength. This assessment is of fundamental importance for establishing prevention strategies. It also allows verifying relationships with functional capacity of individuals. Most studies on grip strength use the JAMAR Hydraulic dynamometer that provides the value of isometric force obtained during the performance of grip movement and is considered the “gold standard” for measurement of grip strength. However, there are different dynamometers available commercially, such as portable computerized dynamometer E-Link (Biometrics), which provides the value of maximum force (peak force) in addition to other variables as the rate of fatigue for hand strength, among others. Of our knowledge, there are no studies that allow us to accept or not and compare values obtained with both devices and perhaps use them interchangeably. The aim of this study was to evaluate the absolute agreement between the measurements of grip strength (peak force or maximum force in kg) obtained from two different devices (portable dynamometers): a computerized (E-Link, Biometrics) and one hydraulic (JAMAR).
Resumo:
A glomerulonefrite membranosa faz parte das doenças glomerulares que provocam glomerulonefrite crônica, apresentando-se como uma das causas da doença renal terminal. As técnicas de imunofluorescência são o gold standard no estudo imunológico desta patologia em biópsia renal, através da deteção de imunocomplexos (e.g. IgG e C3) e do seu padrão de distribuição granular característico. No entanto, a imunofluorescência não permite uma contextualização histológica e os fluorocromos utilizados possuem um reduzido tempo de atividade, ao contrário das técnicas imunoenzimáticas que utilizam cromogénios coloridos precipitados que permitem a obtenção de uma marcação permanente e a sua contextualização histológica por via da utilização de eficientes colorações de contraste. Com a finalidade de contribuir para a qualidade do diagnóstico da glomerulonefrite membranosa, em biópsias renais, procurou-se, com esta pesquisa, identificar uma técnica imunoenzimática, através da conjugação entre diferentes cromogênios e colorações de contraste, que permita a deteção de depósitos de IgG e C3, com padrão granular. Foram constituídos diferentes binômios cromogênio + coloração, com os cromogênios 3,3›- Diaminobenzidine Tetrahydrochloride e 3-Amino-9-ethylcarbazole e as colorações Periodic Acid Schiff, Periodic Acid Methenamine Silver e Hematoxilina. Foram utilizadas 72 secções de tecido provenientes de seis de casos de biópsias renais com diagnóstico de glomerulonefrite membranosa, fixados em formalina a 10% e incluídos em parafina. A recolha de dados foi realizada por observação microscópica com preenchimento de uma grelha de classificação dos parâmetros: preservação da morfologia, intensidade da marcação específica, quantidade relativa de estruturas marcadas, marcação inespecífica/fundo, contraste e padrão da marcação, que permitiu a classificação dos binómios estudados num score quantitativo de 0-100 pontos. O binômio que apresentou melhores resultados foi 3-Amino-9-ethylcarbazole + Hematoxilina (score 71,81) e o binômio 3,3›- Diaminobenzidine Tetrahydrochloride+Periodic Acid Methenamine Silver (score 7,81), apresentou os piores resultados. O resultado do teste Kruskal-Wallis indica-nos a presença de diferenças estatísticas entre os binómios em estudo (p=0,000). A Hematoxilina pode ser considerada a coloração mais eficaz, pois cumpriu a sua função de auxiliar e facilitar a observação do tipo de padrão com os dois cromogênios utilizados. O cromogênio 3-Amino-9-ethylcarbazole apresentou resultados semelhantes aos produzidos pelo 3,3›-Diaminobenzidine Tetrahydrochloride, no entanto, permitiu identificar em todos os casos o padrão granular de imunomarcação, ao contrário do que aconteceu com este último.
Resumo:
Objective Deregulation of FAS/FASL system may lead to immune escape and influence bacillus Calmette-Guérin (BCG) immunotherapy outcome, which is currently the gold standard adjuvant treatment for high-risk non–muscle invasive bladder tumors. Among other events, functional promoter polymorphisms of FAS and FASL genes may alter their transcriptional activity. Therefore, we aim to evaluate the role of FAS and FASL polymorphisms in the context of BCG therapy, envisaging the validation of these biomarkers to predict response. Patients and methods DNA extracted from peripheral blood from 125 patients with bladder cancer treated with BCG therapy was analyzed by Polymerase Chain Reaction—Restriction Fragment Length Polymorphism for FAS-670 A/G and FASL-844 T/C polymorphisms. FASL mRNA expression was analyzed by real-time Polymerase Chain Reaction. Results Carriers of FASL-844 CC genotype present a decreased recurrence-free survival after BCG treatment when compared with FASL-844 T allele carriers (mean 71.5 vs. 97.8 months, P = 0.030) and have an increased risk of BCG treatment failure (Hazard Ratio = 1.922; 95% Confidence Interval: [1.064–3.471]; P = 0.030). Multivariate analysis shows that FASL-844 T/C and therapeutics scheme are independent predictive markers of recurrence after treatment. The evaluation of FASL gene mRNA levels demonstrated that patients carrying FASL-844 CC genotype had higher FASL expression in bladder tumors (P = 0.0027). Higher FASL levels were also associated with an increased risk of recurrence after BCG treatment (Hazard Ratio = 2.833; 95% Confidence Interval: [1.012–7.929]; P = 0.047). FAS-670 A/G polymorphism analysis did not reveal any association with BCG therapy outcome. Conclusions Our results suggest that analysis of FASL-844 T/C, but not FAS-670 A/G polymorphisms, may be used as a predictive marker of response to BCG immunotherapy.
Resumo:
Dissertação de Mestrado em Gerontologia Social
Resumo:
OBJECTIVE: To validate a new symphysis-fundal curve for screening fetal growth deviations and to compare its performance with the standard curve adopted by the Brazilian Ministry of Health. METHODS: Observational study including a total of 753 low-risk pregnant women with gestational age above 27 weeks between March to October 2006 in the city of João Pessoa, Northeastern Brazil. Symphisys-fundal was measured using a standard technique recommended by the Brazilian Ministry of Health. Estimated fetal weight assessed through ultrasound using the Brazilian fetal weight chart for gestational age was the gold standard. A subsample of 122 women with neonatal weight measurements was taken up to seven days after estimated fetal weight measurements and symphisys-fundal classification was compared with Lubchenco growth reference curve as gold standard. Sensitivity, specificity, positive and negative predictive values were calculated. The McNemar χ2 test was used for comparing sensitivity of both symphisys-fundal curves studied. RESULTS: The sensitivity of the new curve for detecting small for gestational age fetuses was 51.6% while that of the Brazilian Ministry of Health reference curve was significantly lower (12.5%). In the subsample using neonatal weight as gold standard, the sensitivity of the new reference curve was 85.7% while that of the Brazilian Ministry of Health was 42.9% for detecting small for gestational age. CONCLUSIONS: The diagnostic performance of the new curve for detecting small for gestational age fetuses was significantly higher than that of the Brazilian Ministry of Health reference curve.
Resumo:
OBJECTIVE: Bacillus Calmette-Guérin (BCG) immunotherapy is the gold standard treatment for superficial bladder tumors with intermediate/high risk of recurrence or progression. However, approximately 30% of patients fail to respond to the treatment. Effective BCG therapy needs precise activation of the type 1 helper cells immune pathway. Tumor-associated macrophages (TAMs) often assume an immunoregulatory M2 phenotype and may directly interfere with the BCG-induced antitumor immune response. Thus, we aim to clarify the influence of TAMs, in particular of the M2 phenotype in stroma and tumor areas, in BCG treatment outcome. PATIENTS AND METHODS: The study included 99 patients with bladder cancer treated with BCG. Tumors resected before treatment were evaluated using immunohistochemistry for CD68 and CD163 antigens, which identify a lineage macrophage marker and a M2-polarized specific cell surface receptor, respectively. CD68+ and CD163+ macrophages were evaluated within the stroma and tumor areas, and high density of infiltrating cells spots were selected for counting. Hypoxia, an event known to modulate macrophage phenotype, was also assessed through hypoxia induced factor (HIF)-1α expression. RESULTS: Patients in whom BCG failed had high stroma-predominant CD163+ macrophage counts (high stroma but low tumor CD163+ macrophages counts) when compared with the ones with a successful treatment (71% vs. 47%, P = 0.017). Furthermore, patients presenting this phenotype showed decreased recurrence-free survival (log rank, P = 0.008) and a clear 2-fold increased risk of BCG treatment failure was observed in univariate analysis (hazard ratio = 2.343; 95% CI: 1.197-4.587; P = 0.013). Even when adjusted for potential confounders, such as age and therapeutic scheme, multivariate analysis revealed 2.6-fold increased risk of recurrence (hazard ratio = 2.627; 95% CI: 1.340-5.150; P = 0.005). High stroma-predominant CD163+ macrophage counts were also associated with low expression of HIF-1α in tumor areas, whereas high counts of CD163+ in the tumor presented high expression of HIF-1α in tumor nests. CONCLUSIONS: TAMs evaluation using CD163 is a good indicator of BCG treatment failure. Moreover, elevated infiltration of CD163+ macrophages, predominantly in stroma areas but not in the tumor, may be a useful indicator of BCG treatment outcome, possibly owing to its immunosuppressive phenotype.
Resumo:
Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.
Resumo:
OBJECTIVE To validate a screening instrument using self-reported assessment of frailty syndrome in older adults.METHODS This cross-sectional study used data from the Saúde, Bem-estar e Envelhecimento study conducted in Sao Paulo, SP, Southeastern Brazil. The sample consisted of 433 older adult individuals (≥ 75 years) assessed in 2009. The self-reported instrument can be applied to older adults or their proxy respondents and consists of dichotomous questions directly related to each component of the frailty phenotype, which is considered the gold standard model: unintentional weight loss, fatigue, low physical activity, decreased physical strength, and decreased walking speed. The same classification proposed in the phenotype was utilized: not frail (no component identified); pre-frail (presence of one or two components), and frail (presence of three or more components). Because this is a screening instrument, “process of frailty” was included as a category (pre-frail and frail). Cronbach’s α was used in psychometric analysis to evaluate the reliability and validity of the criterion, the sensitivity, the specificity, as well as positive and negative predictive values. Factor analysis was used to assess the suitability of the proposed number of components.RESULTS Decreased walking speed and decreased physical strength showed good internal consistency (α = 0.77 and 0.72, respectively); however, low physical activity was less satisfactory (α = 0.63). The sensitivity and specificity for identifying pre-frail individuals were 89.7% and 24.3%, respectively, while those for identifying frail individuals were 63.2% and 71.6%, respectively. In addition, 89.7% of the individuals from both the evaluations were identified in the “process of frailty” category.CONCLUSIONS The self-reported assessment of frailty can identify the syndrome among older adults and can be used as a screening tool. Its advantages include simplicity, rapidity, low cost, and ability to be used by different professionals.
Resumo:
A estereopsia é o 3º grau da visão binocular. Define-se pela perceção de profundidade e baseia-se na disparidade retiniana. Estereopsia global – estereograma de pontos aleatórios (perceção necessita de disparidade retiniana). Estereopsia local – estereogramas com contornos percebidos monocularmente (processo de fusão facilitado). Objectivos do estudo: 1) comparar valores de estereopsia obtidos em cada teste e analisar valores de estereopsia local e global; 2) estudar a correlação de valores de estereopsia nos testes (TNO goldstandard); 3) estudar a associação entre o resultado dos testes; 4) comparar exatidão entre FlyTeste StereoTAB; 5) estudar a sensibilidade e a especificidade do FlyTeste StereoTAB; 6) averiguar a aplicabilidade do SteroTABna prática clínica.
Resumo:
Background: Computed tomography (CT) is one of the most used modalities for diagnostics in paediatric populations, which is a concern as it also delivers a high patient dose. Research has focused on developing computer algorithms that provide better image quality at lower dose. The iterative reconstruction algorithm Sinogram-Affirmed Iterative Reconstruction (SAFIRE) was introduced as a new technique that reduces noise to increase image quality. Purpose: The aim of this study is to compare SAFIRE with the current gold standard, Filtered Back Projection (FBP), and assess whether SAFIRE alone permits a reduction in dose while maintaining image quality in paediatric head CT. Methods: Images were collected using a paediatric head phantom using a SIEMENS SOMATOM PERSPECTIVE 128 modulated acquisition. 54 images were reconstructed using FBP and 5 different strengths of SAFIRE. Objective measures of image quality were determined by measuring SNR and CNR. Visual measures of image quality were determined by 17 observers with different radiographic experiences. Images were randomized and displayed using 2AFC; observers scored the images answering 5 questions using a Likert scale. Results: At different dose levels, SAFIRE significantly increased SNR (up to 54%) in the acquired images compared to FBP at 80kVp (5.2-8.4), 110kVp (8.2-12.3), 130kVp (8.8-13.1). Visual image quality was higher with increasing SAFIRE strength. The highest image quality was scored with SAFIRE level 3 and higher. Conclusion: The SAFIRE algorithm is suitable for image noise reduction in paediatric head CT. Our data demonstrates that SAFIRE enhances SNR while reducing noise with a possible reduction of dose of 68%.