916 resultados para electrical conductivity of poly(p-phenylene sulfide)
Resumo:
In order to assess the influence of the colostrum period on pH and, electrical conductivity, we collected 418 milk samples from 127 Jersey cows. The samples were collected from healthy udders that did not present any bacterial growth in the microbiological examination. They were divided into eight groups as follows < 1/2 day; 1/2 and 1 degrees day; 2 degrees day; 3 degrees day; 4 degrees and 5 degrees day; 6 degrees and 7 degrees day; 8 degrees to 15 degrees day; 16 degrees to 30 degrees days of lactation. The samples were collected before milking and the following analyses were conducted: pH, electrical conductivity. In the first 24 hours of lactation, there was an reduction in electrical conductivity value, associated with an increase in pH value. We observed that transition of secretion from colostrum to milk, occurs during the first week of lactation; from 6(rd) day of lactation for pH value and 3(th) day for electrical conductivity value. We recommend the use the following figures as normal ranges for the first 24 hours of lactation (colostrum period): pH <= 6,51 and electrical conductivity <= 6,33 mS/cm; while for the interval between 2(nd) and 7(th) days of lactation (transition from colostrum to milk) we suggest the use of the values as normal ranges: pH <= 6,66 and electrical conductivity <= 5,93 mS/cm.
Resumo:
We study the effect of thermal disorder on the electronic structure of one-dimensional poly-para-phenylene (PPP). In a real chain the torsion angles between rings are bound to be distributed over a range of values, which depend on temperature, and thus the chain is intrinsically disordered. In this study we simulated this kind of thermally induced off-diagonal disorder through the simple Huckel method. We base our Hamiltonian on ab initio results for the effect of temperature on torsion angles, and the effect of torsion angles on the energy gap. We analyze the electronic structure of 200-monomer-long chains focusing on the density of states, and the associated localization character (measured by the inverse participation ratio). Our results contrast with the usually assumed Gaussian-shaped density of localized states for disordered systems. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Blend films (free-standing) containing 20% in volume of polyaniline (PANI) in 80% of natural rubber (NR) were fabricated by casting in three different ways: (1) adding PANI-EB (emeraldine base) dissolved in N-methyl-2-pyrrolidone (NMP) to the latex (NRL), (2) adding PANI-EB dissolved in in-cresol to NR dissolved in xylol (NRD), (3) overlaying the surface of a pure NR cast film with a PANI layer grown by in situ polymerization (NRO). All the films were immersed into HCl solution to achieve the primary doping (protonation) of PANI before the characterization. The main goal here was to investigate the elastomeric and electrical conductivity properties for each blend, which may be applied as pressure and deformation sensors in the future. The characterization was carried out by optical microscopy, dc conductivity, vibrational spectroscopy (infrared absorption and Raman scattering), thermogravimetry analysis (TGA), differential scanning calorimetry (DSC), dynamic mechanical thermal analysis (DMTA), and tensile stress-strain curves. The results suggest that the NRL blend is the most suitable in terms of mechanical and electrical properties required for applications in pressure and deformation sensors: a gain of conductivity without losing the elastomeric property of the rubber. (c) 2005 Wiley Periodicals, Inc.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Gigahertz conductivity of pressed pellets of ClO4--doped poly( 3-methylthiophene) can be readily obtained from the asymmetry ratio (A / B) of the electron spin resonance line using Dyson's theory. The measurements were performed in three different frequencies, 1.3, 9.4, and 35 GHz. The temperature dependence of the gigahertz conductivity is sensitive to the heating rate, probably due to the ordering of the randomly assembled anions. (C) 1994 Academic Press, Inc.
Resumo:
Seeds from six soybean cultivars (Cristalina, IAC 31-Foscarin, IAC-15, UFV-10, IAC-14 and IAS-5) and from five soybean cultivars (IAC 31-Foscarin, IAC-15, IAC-14, IAS-5 and Iguacu) were evaluated in 1993 and 1994, respectively, in terms of physiological seed quality by the mechanical damage (MD), standard germination (SG), accelerated aging (AA), electrical conductivity (EC), and seedling field emergence (FE) tests. Significant correlations were detected between SG, AA and EC and FE. However, in terms of the cultivar or the year, the degree of association among these parameters can change based on the environmental conditions of each year.
Resumo:
The local order around K for K(CF3SO3) doped Siloxane-Poly(propyleneoxide) hybrids at different doping concentration was investigated by x-ray absorption spectroscopy (EXAFS and XANES) at the potassium K-edge. The results indicate that the use of HCl as hydrolytic catalyst for gelation induces the precipitation of KCl. The ionic conductivity is strongly related to the presence of oxygen atoms as first neighbours around potassium and to the amount of KCl precipitate. © Physica Scripta 2005.
Alterations in levels of NPK, electrical conductivity and pH of substrate, in cultivation of peppers
Resumo:
The objective of this work was to evaluate the chemical alterations of the substrate in the cultivation of pepper in coconut husk fiber, in a protected environment. Initially, 160 pepper plants ('Eppo') were divided into four blocks, where two pots per block were analyzed every 21 days after transplanting. The cultivation of pepper was carried out in plastic pots of 13 L, containing coconut husk fiber, and placed in double rows with a spacing of 0.5×0.8 m between single rows and 1.10 m between double rows. After removal of the plants from the pots, individual samples of substrate (approximately 1 L) were collected from each pot and dried at ambient temperature. Electrical conductivity (EC), pH, and levels of NH4 +-N, NO3 -, P and K were determined for all periods of the cultivation. These analyses were performed using the method of extraction 1:1.5 v/v. For the conditions which the experiment was conducted, there was an increase in substrate EC, as well as in the levels of nitrogen, phosphorus and potassium.
Resumo:
Rapid tests to assess the nutritional status of plants gerbera can make easier the decision of any adjustments in the fertilization of the substrate. The study was conducted to evaluate nutritionally fertigated gerbera plants with increasing levels of electrical conductivity (EC), using portable meters nitrate and potassium, and chlorophyll. For this, two experiments were conducted. A randomized block design with five levels of EC (0.5, 2.0, 3.5, 5.0 and 6.5 dS m-1) and four replications was used. Cherry cultivar was used in the first experiment. In the second experiment, two cultivars (Cherry and Salmon Rose) were used. In the first experiment, the sap of the leaves was subjected to rapid testing of N-NO3- (equipment Cardy Horiba C -141). N-NO3- and K+ (C-131) were determined in the substrate solution. The intensity of the green leaf, in the second experiment was evaluated with portable Chlorophyll Meter. The N content in the indicator leaf in the first and N and K contents in the plant in the second experiment were determined. Rapid tests are presented as good indicators of the level of N-NO3- and K+ in plant tissue, with the advantages of convenience and speed of determination, facilitating monitoring of fertilization of the substrate by producers and technicians.
Resumo:
A very simple method based on electrical conductivity and pH measurements was proposed for assessing reactivity of pozzolans. Calcium hydroxide: pozzolan water suspensions were monitored by means of measurements of electrical conductivity and pH values. In these suspensions, Ca(OH)(2) in solid state was initially present, being them, thus, saturated in this reagent. Three testing temperatures were selected (40, 50 and 60 degrees C). In the experiments carried out, calcium hydroxide was suspended in deionized water for yielding a lime saturated suspension. The addition of siliceous pozzolan (two types of rice husk ash RHA and two types of densified silica fume DSF were tested) to the saturated lime suspension can produce the unsaturation of the system, depending on the testing time, testing temperature and reactivity of pozzolan. When unsaturation was reached, the loss of electrical conductivity was higher than 30% and the variation of pH was higher than 0.15 units. These threshold values were selected for characterizing the reactivity of pozzolans by means of a proposed template, classifying the pozzolan in three different reactivity levels.
Resumo:
Pós-graduação em Engenharia Mecânica - FEG