1000 resultados para dengue diagnosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performance of a serum PCR assay was compared with that of a blood PCR assay for the diagnosis of canine brucellosis caused by Brucella canis in 72 dogs. The dogs were classified into three groups (infected, non-infected and suspected brucellosis) according to the results of blood culture and serological tests. The sensitivities of blood PCR and serum PCR were, respectively, 97.14 per cent and 25.71 per cent. The specificities of both were 100 per cent. In the group of dogs with suspected brucellosis, three were positive by blood PCR and none was positive by serum PCR. Serum PCR showed little value for the direct diagnosis of canine brucellosis as the assay had low diagnostic sensitivity and fewer positive dogs were detected by this test than by blood culture, blood PCR, rapid slide agglutination test (RSAT) and RSAT with 2-mercaptoethanol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: We carry out a systematic assessment on a suite of kernel-based learning machines while coping with the task of epilepsy diagnosis through automatic electroencephalogram (EEG) signal classification. Methods and materials: The kernel machines investigated include the standard support vector machine (SVM), the least squares SVM, the Lagrangian SVM, the smooth SVM, the proximal SVM, and the relevance vector machine. An extensive series of experiments was conducted on publicly available data, whose clinical EEG recordings were obtained from five normal subjects and five epileptic patients. The performance levels delivered by the different kernel machines are contrasted in terms of the criteria of predictive accuracy, sensitivity to the kernel function/parameter value, and sensitivity to the type of features extracted from the signal. For this purpose, 26 values for the kernel parameter (radius) of two well-known kernel functions (namely. Gaussian and exponential radial basis functions) were considered as well as 21 types of features extracted from the EEG signal, including statistical values derived from the discrete wavelet transform, Lyapunov exponents, and combinations thereof. Results: We first quantitatively assess the impact of the choice of the wavelet basis on the quality of the features extracted. Four wavelet basis functions were considered in this study. Then, we provide the average accuracy (i.e., cross-validation error) values delivered by 252 kernel machine configurations; in particular, 40%/35% of the best-calibrated models of the standard and least squares SVMs reached 100% accuracy rate for the two kernel functions considered. Moreover, we show the sensitivity profiles exhibited by a large sample of the configurations whereby one can visually inspect their levels of sensitiveness to the type of feature and to the kernel function/parameter value. Conclusions: Overall, the results evidence that all kernel machines are competitive in terms of accuracy, with the standard and least squares SVMs prevailing more consistently. Moreover, the choice of the kernel function and parameter value as well as the choice of the feature extractor are critical decisions to be taken, albeit the choice of the wavelet family seems not to be so relevant. Also, the statistical values calculated over the Lyapunov exponents were good sources of signal representation, but not as informative as their wavelet counterparts. Finally, a typical sensitivity profile has emerged among all types of machines, involving some regions of stability separated by zones of sharp variation, with some kernel parameter values clearly associated with better accuracy rates (zones of optimality). (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power distribution automation and control are import-ant tools in the current restructured electricity markets. Unfortunately, due to its stochastic nature, distribution systems faults are hardly avoidable. This paper proposes a novel fault diagnosis scheme for power distribution systems, composed by three different processes: fault detection and classification, fault location, and fault section determination. The fault detection and classification technique is wavelet based. The fault-location technique is impedance based and uses local voltage and current fundamental phasors. The fault section determination method is artificial neural network based and uses the local current and voltage signals to estimate the faulted section. The proposed hybrid scheme was validated through Alternate Transient Program/Electromagentic Transients Program simulations and was implemented as embedded software. It is currently used as a fault diagnosis tool in a Southern Brazilian power distribution company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A thermodynamic information system for diagnosis and prognosis of an existing power plant was developed. The system is based on an analytic approach that informs the current thermodynamic condition of all cycle components, as well as the improvement that can be obtained in the cycle performance by the elimination of the discovered anomalies. The effects induced by components anomalies and repairs in other components efficiency, which have proven to be one of the main drawbacks in the diagnosis and prognosis analyses, are taken into consideration owing to the use of performance curves and corrected performance curves together with the thermodynamic data collected from the distributed control system. The approach used to develop the system is explained, the system implementation in a real gas turbine cogeneration combined cycle is described and the results are discussed. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We standardized serodiagnosis of dogs infected with Trypanosoma cruzi using TESA (trypomastigote excreted-secreted antigen)-blot developed for human Chagas disease. TESA-blot showed 100% sensitivity and specificity. In contrast, ELISA using TESA (TESA-ELISA) or epimastigotes (epi-ELISA) as antigen yielded 100% sensitivity but specificity of 94.1% and 49.4%, respectively. When used in field studies in an endemic region for Chagas disease, visceral leishmaniasis and Trypanosoma evansi (Mato Grosso do Sul state, Central Brazil), positivities were 9.3% for TESA-blot, 10.7% for TESA-ELISA and 32% for epi-ELISA. Dogs from a non-endemic region for these infections (Rondonia state, western Amazonia) where T cruzi is enzootic showed positivity of 4.5% for TESA-blot and epi-ELISA and 6.8% for TESA-ELISA. Sera from urban dogs from Santos, Sao Paulo, where these diseases are absent, yielded negative results. TESA-blot was the only method that distinguished dogs infected with T cruzi from those infected with Leishmania chagasi and/or Trypanosoma evansi. (C) 2009 Published by Elsevier B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rare HFE variants have been shown to be associated with hereditary hemochromatosis (HH), an iron overload disease. The low frequency of the HFE p.C282Y mutation in HH-affected Brazilian patients may suggest that other HFE-related mutations may also be implicated in the pathogenesis of HH in this population. The main aim was to screen for new HFE mutations in Brazilian individuals with primary iron overload and to investigate their relationship with HH. Fifty Brazilian patients with primary iron overload (transferrin saturation >50% in females and 60% in males) were selected. Subsequent bidirectional sequencing for each HFE exon was performed. The effect of HFE mutations on protein structure were analyzed by molecular dynamics simulation and free binding energy calculations. p.C282Y in homozygosis or in heterozygosis with p.H63D were the most frequent genotypic combinations associated with HH in our sample population (present in 17 individuals, 34%). Thirty-six (72.0%) out of the 50 individuals presented at least one HFE mutation. The most frequent genotype associated with HH was the homozygous p.C282Y mutation (n = 11, 22.0%). One novel mutation (p.V256I) was indentified in heterozygosis with the p.H63D mutation. In silico modeling analysis of protein behavior indicated that the p.V256I mutation does not reduce the binding affinity between HFE and beta 2-microglobulin ((beta 2M) in the same way the p.C282Y mutation does compared with the native HFE protein. In conclusion, screening of HFE through direct sequencing, as compared to p.C282Y/p.H63D genotyping, was not able to increase the molecular diagnosis yield of HH. The novel p.V256I mutation could not be implicated in the molecular basis of the HH phenotype, although its role cannot be completely excluded in HH-phenotype development. Our molecular modeling analysis can help in the analysis of novel, previously undescribed, HFE mutations. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, 20 Brazilian public schools have been assessed regarding good manufacturing practices and standard sanitation operating procedures implementation. We used a checklist comprised of 10 parts ( facilities and installations, water supply, equipments and tools, pest control, waste management, personal hygiene, sanitation, storage, documentation, and training), making a total of 69 questions. The implementing modification cost to the found nonconformities was also determined so that it could work with technical data as a based decision-making prioritization. The average nonconformity percentage at schools concerning to prerequisite program was 36%, from which 66% of them own inadequate installations, 65% waste management, 44% regarding documentation, and 35% water supply and sanitation. The initial estimated cost for changing has been U.S.$24,438 and monthly investments of 1.55% on the currently needed invested values. This would result in U.S.$0.015 increase on each served meal cost over the investment replacement within a year. Thus, we have concluded that such modifications are economically feasible and will be considered on technical requirements when prerequisite program implementation priorities are established.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background & Aims: An elevated transferrin saturation is the earliest phenotypic abnormality in hereditary hemochromatosis. Determination of transferrin saturation remains the most useful noninvasive screening test for affected individuals, but there is debate as to the appropriate screening level. The aims of this study were to estimate the mean transferrin saturation in hemochromatosis heterozygotes and normal individuals and to evaluate potential transferrin saturation screening levels. Methods: Statistical mixture modeling was applied to data from a survey of asymptomatic Australians to estimate the mean transferrin saturation in hemochromatosis heterozygotes and normal individuals. To evaluate potential transferrin saturation screening levels, modeling results were compared with data from identified hemochromatosis heterozygotes and homozygotes. Results: After removal of hemochromatosis homozygotes, two populations of transferrin saturation were identified in asymptomatic Australians (P < 0.01). In men, 88.2% of the truncated sample had a lower mean transferrin saturation of 24.1%, whereas 11.8% had an increased mean transferrin saturation of 37.3%. Similar results were found in women, A transferrin saturation threshold of 45% identified 98% of homozygotes without misidentifying any normal individuals. Conclusions: The results confirm that hemochromatosis heterozygotes form a distinct transferrin saturation subpopulation and support the use of transferrin saturation as an inexpensive screening test for hemochromatosis. In practice, a fasting transferrin saturation of greater than or equal to 45% identifies virtually all affected homozygous subjects without necessitating further investigation of unaffected normal individuals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PCR-based cancer diagnosis requires detection of rare mutations in k-ras, p53 or other genes. The assumption has been that mutant and wild-type sequences amplify with near equal efficiency, so that they are eventually present in proportions representative of the starting material. Work factor IX suggests that this assumption is invalid for one case of near-sequence identity To test the generality of this phenomenon and its relevance to cancer diagnosis, primers distant from point mutations in p53 and k-ras were used to amplify, wild-type and mutant sequences from these genes. A substantial bias against PCR amplification of mutants was observed for two regions of the p53 gene and one region of k-ras. For kras and p53, bias was observed when the wild-type and mutant sequences were amplified separately or when mixed in equal proportions before PCR. Bias was present with proofreading and non-proofreading polymerases. Mutant and wild-type segments of the factor V cystic fibrosis transmembrane conductance regulator and prothrombin genes were amplified and did not exhibit PCR bias. Therefore, the assumption of equal PCR efficiency for point mutant and wild-type sequences is invalid in several systems. Quantitative or diagnostic PCR will require validation for each locus, and enrichment strategies may be needed to optimize detection of mutants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A series of surveys of mental health literacy have been undertaken in Australia, involving members of the general public as well as general practitioners and mental health professionals, whereby respondents consider vignettes of depression and of schizophrenia, offer a diagnosis and rate a series of possible interventions for their judged helpfulness. A similar survey was undertaken in Singapore and is reported in this paper. Methods: The survey was undertaken at a large state psychiatric hospital with staff (psychiatrists, allied health professionals, psychiatrically and generally trained nursing staff) rating a vignette of mania, in addition to the vignettes derived in Australia for depression and schizophrenia, and with the Australian intervention options extended somewhat to respect Singapore facilities. Results: Responses of those in the four professional groups were compared. The psychiatrists were highly accurate in generating diagnoses, other staff somewhat less so for diagnosing depression (with a percentage instead choosing a diagnosis of stress) and mania (with a percentage instead diagnosing a schizophrenic condition). Reported helpfulness ratings identified those interventions judged consensually as likely to be helpful or harmful, as well as establishing some differences across the four professional groups. Conclusions: The consensus decisions of helpful treatments for depression and schizophrenia revealed very similar findings to judgements made by Australian professionals. The treated outcome of schizophrenia was judged as somewhat worse than that for mania and depression. While non-medical staff differed from psychiatrists in judging the comparative utility of some drug interventions and lifestyle issues, there was clear evidence of a relatively dominant 'medical model' to recommended treatments, while traditional healing practices and services were rated as distinctly unhelpful.