994 resultados para continuous integration
Resumo:
Algorithms for explicit integration of structural dynamics problems with multiple time steps (subcycling) are investigated. Only one such algorithm, due to Smolinski and Sleith has proved to be stable in a classical sense. A simplified version of this algorithm that retains its stability is presented. However, as with the original version, it can be shown to sacrifice accuracy to achieve stability. Another algorithm in use is shown to be only statistically stable, in that a probability of stability can be assigned if appropriate time step limits are observed. This probability improves rapidly with the number of degrees of freedom in a finite element model. The stability problems are shown to be a property of the central difference method itself, which is modified to give the subcycling algorithm. A related problem is shown to arise when a constraint equation in time is introduced into a time-continuous space-time finite element model. (C) 1998 Elsevier Science S.A.
Resumo:
Control of chaos in the single-mode optically pumped far-infrared (NH3)-N-15 laser is experimentally demonstrated using continuous time-delay control. Both the Lorenz spiral chaos and the detuned period-doubling chaos exhibited by the laser have been controlled. While the laser is in the Lorenz spiral chaos regime the chaos has been controlled both such that the laser output is cw, with corrections of only a fraction of a percent necessary to keep it there, and to period one. The laser has also been controlled while in the period-doubling chaos regime, to both the period-one and -two states.
Resumo:
We shall study continuous-time Markov chains on the nonnegative integers which are both irreducible and transient, and which exhibit discernible stationarity before drift to infinity sets in. We will show how this 'quasi' stationary behaviour can be modelled using a limiting conditional distribution: specifically, the limiting state probabilities conditional on not having left 0 for the last time. By way of a dual chain, obtained by killing the original process on last exit from 0, we invoke the theory of quasistationarity for absorbing Markov chains. We prove that the conditioned state probabilities of the original chain are equal to the state probabilities of its dual conditioned on non-absorption, thus allowing us to establish the simultaneous existence and then equivalence, of their limiting conditional distributions. Although a limiting conditional distribution for the dual chain is always a quasistationary distribution in the usual sense, a similar statement is not possible for the original chain.
Resumo:
This note considers continuous-time Markov chains whose state space consists of an irreducible class, C, and an absorbing state which is accessible from C. The purpose is to provide results on mu-invariant and mu-subinvariant measures where absorption occurs with probability less than one. In particular, the well-known premise that the mu-invariant measure, m, for the transition rates be finite is replaced by the more natural premise that m be finite with respect to the absorption probabilities. The relationship between mu-invariant measures and quasi-stationary distributions is discussed. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
This article deals with the efficiency of fractional integration parameter estimators. This study was based on Monte Carlo experiments involving simulated stochastic processes with integration orders in the range]-1,1[. The evaluated estimation methods were classified into two groups: heuristics and semiparametric/maximum likelihood (ML). The study revealed that the comparative efficiency of the estimators, measured by the lesser mean squared error, depends on the stationary/non-stationary and persistency/anti-persistency conditions of the series. The ML estimator was shown to be superior for stationary persistent processes; the wavelet spectrum-based estimators were better for non-stationary mean reversible and invertible anti-persistent processes; the weighted periodogram-based estimator was shown to be superior for non-invertible anti-persistent processes.
Resumo:
The population structure, reproductive period, and juvenile recruitment of Panopeus americanus were studied in order to enhance knowledge of its life cycle and reproductive strategy and promote the maintenance of its natural stocks in an impacted region. Specimens were collected in the remnant human-impacted mangrove at Araca, state of Sao Paulo, Brazil, at two-month intervals from January to November 2005, at low tide, with a capture effort by three people. The crabs were measured (carapace width, CW) and sexed. The total catch was 275 animals, including 132 males (48.0%); 127 females (46.2%), of which 39 were ovigerous (14.2% of total catch); and 16 individuals whose sex could not be identified (5.8%). No correlation was observed between water temperature and the number of collected individuals; however, there was a significant, positive correlation with salinity. Males were significantly larger than females. The size-frequency distribution was bimodal, reflecting the occurrende of more than one recruitment pulse and the differential abundance of adults during the period of study. The overall sex ratio was 1:0.97 favoring males, and was not significantly different from the expected value, i.e., this population fits the anomalous pattern of sex occurrence in size classes. Ovigerous females were captured in all sampled months, which explain the continuous recruitment observed. Expected low levels of individuals of different size classes in the population were not confirmed. All population aspects found here allowed us to infer that this population of P. americanus is well established in the impacted mangrove by virtue of its reproductive strategy.
Resumo:
Background: The objective of this study was to compare bleeding patterns of women using a contraceptive combination of 30 mcg ethinylestradiol (EE) and 3 mg drospirenone (DRSP) continuously or cyclically. Menstrual-related symptoms were also evaluated. Study Design: This open, prospective, randomized study evaluated 78 women using the EE/DRSP combination continuously for 168 days or for six 28-day cycles, each followed by a 7-day hormone-free interval. A diary with pre-established scales was used to assess the frequency and intensity of bleeding and menstrual-related symptoms. Results: Amenorrhea increased with continuous use; 62.2% of women with continuous use were amenorrheic at the end of treatment (95% CI: 46.6-77.8%). Dysmenorrhea, headache, acne, nausea, edema and increased appetite improved significantly in the continuous-use group, and mastalgia and edema in the cyclic-use group (p<.05). Six subjects in the continuous-use group (15.4%) and three in the cyclic-use group (7.7%) discontinued due to adverse events. Conclusions: Continuous use was associated with amenorrhea and fewer menstrual-related symptoms compared to cyclic use. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background: The objective of this study was to evaluate the effects of a contraceptive pill containing ethinylestradiol (30 mcg) and drospirenone (3 mg) in a continuous regimen on lipid, carbohydrate and coagulation parameters. Study Design: This open, prospective, randomized study included 78 participants (mean age 27.8 years) who were randomized into two groups to use the pill continuously for 168 days or for six 28-day cycles with a 7-day hormone-free interval between cycles. Markers of lipid, carbohydrate and coagulation profiles were measured prior to initiation and after the 6 months of pill use. Results: No statistically significant differences were found between the two contraceptive regimens with respect to carbohydrate or lipid profiles or in the parameters related to coagulation. Conclusions: The contraceptive combination of ethinylestradiol and drospirenone used in a continuous regimen was associated with metabolic alterations similar to those found during the traditional cyclic regimen of oral contraceptive use. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background: Obesity and obstructive sleep apnea (OSA) are both associated with the prevalence of major cardiovascular illnesses and certain common factors they are considered responsible for, such as stress oxidative increase, sympathetic tonus and resistance to insulin. Objective: The aim of the present study was to compare the effect of continuous positive airway pressure (CPAP) on oxidative stress and adiponectin levels in obese patients with and without OSA. Methods: Twenty-nine obese patients were categorized into 3 groups: group 1: 10 individuals without OSA (apnea-hypopnea index, AHI <= 5) who did not have OSA diagnosed at polysomnography; group 2: 10 patients with moderate to severe OSA (AHI >= 20) who did not use CPAP; group 3: 9 patients with moderate to severe OSA (AHI >= 20) who used CPAP. Results: Group 3 showed significant differences before and after the use of CPAP, in the variables of diminished production of superoxide, and increased nitrite and nitrate synthesis and adiponectin levels. Positive correlations were seen between the AHI and the superoxide production, between the nitrite and nitrate levels and the adiponectin levels, between superoxide production and the HOMA-IR, and between AHI and the HOMA-IR. Negative correlations were found between AHI and the nitrite and nitrate levels, between the superoxide production and that of nitric oxide, between the superoxide production and the adiponectin levels, between AHI and the adiponectin levels, and between the nitrite and nitrate levels and the HOMA-IR. Conclusions: This study demonstrates that the use of CPAP can reverse the increased superoxide production, the diminished serum nitrite, nitrate and plasma adiponectin levels, and the metabolic changes existing in obese patients with OSA. Copyright (C) 2009 S. Karger AG, Basel
Resumo:
Objectives: To describe current practice for the discontinuation of continuous renal replacement therapy in a multinational setting and to identify variables associated with successful discontinuation. The approach to discontinue continuous renal replacement therapy may affect patient outcomes. However, there is lack of information on how and under what conditions continuous renal replacement therapy is discontinued. Design: Post hoc analysis of a prospective observational study. Setting. Fifty-four intensive care units in 23 countries. Patients: Five hundred twenty-nine patients (52.6%) who survived initial therapy among 1006 patients treated with continuous renal replacement therapy. Interventions: None. Measurements and Main Results., Three hundred thirteen patients were removed successfully from continuous renal replacement therapy and did not require any renal replacement therapy for at least 7 days and were classified as the ""success"" group and the rest (216 patients) were classified as the ""repeat-RRT"" (renal replacement therapy) group. Patients in the ""success"" group had lower hospital mortality (28.5% vs. 42.7%, p < .0001) compared with patients in the ""repeat-RRT"" group. They also had lower creatinine and urea concentrations and a higher urine output at the time of stopping continuous renal replacement therapy. Multivariate logistic regression analysis for successful discontinuation of continuous renal replacement therapy identified urine output (during the 24 hrs before stopping continuous renal replacement therapy: odds ratio, 1.078 per 100 mL/day increase) and creatinine (odds ratio, 0.996 per mu mol/L increase) as significant predictors of successful cessation. The area under the receiver operating characteristic curve to predict successful discontinuation of continuous renal replacement therapy was 0.808 for urine output and 0.635 for creatinine. The predictive ability of urine output was negatively affected by the use of diuretics (area under the receiver operating characteristic curve, 0.671 with diuretics and 0.845 without diuretics). Conclusions. We report on the current practice of discontinuing continuous renal replacement therapy in a multinational setting. Urine output at the time of initial cessation (if continuous renal replacement therapy was the most important predictor of successful discontinuation, especially if occurring without the administration of diuretics. (Crit Care Med 2009; 37:2576-2582)
Resumo:
This study aimed to elucidate electrophysiological and cortical mechanisms involved in anticipatory actions when 23 healthy right-handed subjects had to catch a free falling object by qEEG gamma-band (30-100 Hz). It is involved in cognitive processes, memory, spatial/temporal and proprioceptive factors. Our hypothesis is that an increase in gamma coherence in frontal areas will be observed during moment preceding ball drop, due to their involvement in attention, planning, selection of movements, preparation and voluntary control of action and in central areas during moment after ball drop, due to their involvement in motor preparation, perception and execution of movement. However, through a paired t-test, we found an increase in gamma coherence for F3-F4 electrode pair during moment preceding ball drop and confirmed our hypothesis for C3-C4 electrode pair. We conclude that gamma plays an important role in reflecting binding of several brain areas in a complex motor task as observed in our results. Moreover, for selection of movements, preparation and voluntary control of action, motor preparation, perception and execution of movement, the integration of somatosensory and visual information is mandatory. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Dherte PM, Negrao MPG, Mori Neto S, Holzhacker R, Shimada V, Taberner P, Carmona MJC - Smart Alerts: Development of a Software to Optimize Data Monitoring. Background and objectives: Monitoring is useful for vital follow-ups and prevention, diagnosis, and treatment of several events in anesthesia. Although alarms can be useful in monitoring they can cause dangerous user`s desensitization. The objective of this study was to describe the development of specific software to integrate intraoperative monitoring parameters generating ""smart alerts"" that can help decision making, besides indicating possible diagnosis and treatment. Methods: A system that allowed flexibility in the definition of alerts, combining individual alarms of the parameters monitored to generate a more elaborated alert system was designed. After investigating a set of smart alerts, considered relevant in the surgical environment, a prototype was designed and evaluated, and additional suggestions were implemented in the final product. To verify the occurrence of smart alerts, the system underwent testing with data previously obtained during intraoperative monitoring of 64 patients. The system allows continuous analysis of monitored parameters, verifying the occurrence of smart alerts defined in the user interface. Results: With this system a potential 92% reduction in alarms was observed. We observed that in most situations that did not generate alerts individual alarms did not represent risk to the patient. Conclusions: Implementation of software can allow integration of the data monitored and generate information, such as possible diagnosis or interventions. An expressive potential reduction in the amount of alarms during surgery was observed. Information displayed by the system can be oftentimes more useful than analysis of isolated parameters.
Resumo:
The dynamic response of dry masonry columns can be approximated with finite-difference equations. Continuum models follow by replacing the difference quotients of the discrete model by corresponding differential expressions. The mathematically simplest of these models is a one-dimensional Cosserat theory. Within the presented homogenization context, the Cosserat theory is obtained by making ad hoc assumptions regarding the relative importance of certain terms in the differential expansions. The quality of approximation of the various theories is tested by comparison of the dispersion relations for bending waves with the dispersion relation of the discrete theory. All theories coincide with differences of less than 1% for wave-length-block-height (L/h) ratios bigger than 2 pi. The theory based on systematic differential approximation remains accurate up to L/h = 3 and then diverges rapidly. The Cosserat model becomes increasingly inaccurate for L/h < 2 pi. However, in contrast to the systematic approximation, the wave speed remains finite. In conclusion, considering its relative simplicity, the Cosserat model appears to be the natural starting point for the development of continuum models for blocky structures.