Smart Alerts: Development of Software to Optimize Data Monitoring


Autoria(s): DHERTE, Patrick Marcel; NEGRAO, Mariana Pires Gentil; MORI NETO, Silvio; HOLZHACKER, Rafael; SHIMADA, Vanessa; TABERNER, Paula; CARMONA, Maria Jose Carvalho
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2011

Resumo

Dherte PM, Negrao MPG, Mori Neto S, Holzhacker R, Shimada V, Taberner P, Carmona MJC - Smart Alerts: Development of a Software to Optimize Data Monitoring. Background and objectives: Monitoring is useful for vital follow-ups and prevention, diagnosis, and treatment of several events in anesthesia. Although alarms can be useful in monitoring they can cause dangerous user`s desensitization. The objective of this study was to describe the development of specific software to integrate intraoperative monitoring parameters generating ""smart alerts"" that can help decision making, besides indicating possible diagnosis and treatment. Methods: A system that allowed flexibility in the definition of alerts, combining individual alarms of the parameters monitored to generate a more elaborated alert system was designed. After investigating a set of smart alerts, considered relevant in the surgical environment, a prototype was designed and evaluated, and additional suggestions were implemented in the final product. To verify the occurrence of smart alerts, the system underwent testing with data previously obtained during intraoperative monitoring of 64 patients. The system allows continuous analysis of monitored parameters, verifying the occurrence of smart alerts defined in the user interface. Results: With this system a potential 92% reduction in alarms was observed. We observed that in most situations that did not generate alerts individual alarms did not represent risk to the patient. Conclusions: Implementation of software can allow integration of the data monitored and generate information, such as possible diagnosis or interventions. An expressive potential reduction in the amount of alarms during surgery was observed. Information displayed by the system can be oftentimes more useful than analysis of isolated parameters.

Identificador

REVISTA BRASILEIRA DE ANESTESIOLOGIA, v.61, n.1, p.72-80, 2011

0034-7094

http://producao.usp.br/handle/BDPI/21492

http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000287825800008&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord

Idioma(s)

eng

Publicador

ELSEVIER SCIENCE INC

Relação

Revista Brasileira de Anestesiologia

Direitos

closedAccess

Copyright ELSEVIER SCIENCE INC

Palavras-Chave #Monitoring #Intraoperative #Clinical Alarms #Anesthesia #Software #Decision Support Systems #Clinical #ALARMS
Tipo

article

original article

publishedVersion