972 resultados para applicability
Resumo:
Adhesive tape is commonly used in crimes and is often the subject of forensic evaluation. DNA analysis of adhesive tape can provide DNA profiles of suspects. The object of this study was to evaluate the applicability of DNA analysis on adhesive tape samples in forensic casework. We retrospectively reviewed all cases involving adhesive tape or similar items received by our institute for DNA analysis during the past 11 years. From 100 forensic cases reviewed, 150 adhesive tape samples were examined. A total of 98 DNA profiles were obtained from these samples. Sixty-two of the profiles provided feasible case-relevant information. In conclusion, DNA profiling of adhesive tape samples can be useful in a variety of forensic cases.
Resumo:
PURPOSE: The aim of this study was to evaluate the feasibility of applying a previously described dose strategy based on (99m)Tc-pertechnetate thyroid uptake under thyrotropin suppression (TcTU(s)) to radioiodine therapy for unifocal thyroid autonomy. METHODS: A total of 425 consecutive patients (302 females, 123 males; age 63.1+/-10.3 years) with unifocal thyroid autonomy were treated at three different centres with (131)I, using Marinelli's formula for calculation of three different absorbed dose schedules: 100-300 Gy to the total thyroid volume according to the pre-treatment TcTU(s) (n=146), 300 Gy to the nodule volume (n=137) and 400 Gy to the nodule volume (n=142). RESULTS: Successful elimination of functional thyroid autonomy with either euthyroidism or hypothyroidism occurred at a mean of 12 months after radioiodine therapy in 94.5% of patients receiving 100-300 Gy to the thyroid volume, in 89.8% of patients receiving 300 Gy to the nodule volume and in 94.4% receiving 400 Gy to the nodule volume. Reduction in thyroid volume was highest for the 100-300 Gy per thyroid and 400 Gy per nodule strategies (36+/-19% and 38+/-20%, respectively) and significantly lower for the 300 Gy per nodule strategy (28+/-16%; p<0.01). CONCLUSION: A dose strategy based on the TcTU(s) can be used independently of the scintigraphic pattern of functional autonomous tissue in the thyroid.
Resumo:
BACKGROUND AND PURPOSE: Analyses of permanent brachytherapy seed implants of the prostate have demonstrated that the use of a preplan may lead to a considerable decrease of dosimetric implant quality. The authors aimed to determine whether the same drawbacks of preplanning also apply to high-dose-rate (HDR) brachytherapy. PATIENTS AND METHODS: 15 patients who underwent two separate HDR brachytherapy implants in addition to external-beam radiation therapy for advanced prostate cancer were analyzed. A pretherapeutic transrectal ultrasound was performed in all patients to generate a preplan for the first brachytherapy implant. For the second brachytherapy, a subset of patients were treated by preplans based on the ultrasound from the first brachytherapy implant. Preplans were compared with the respective postplans assessing the following parameters: coverage index, minimum target dose, homogeneity index, and dose exposure of organs at risk. The prostate geometries (volume, width, height, length) were compared as well. RESULTS: At the first brachytherapy, the matching between the preplan and actual implant geometry was sufficient in 47% of the patients, and the preplan could be applied. The dosimetric implant quality decreased considerably: the mean coverage differed by -0.11, the mean minimum target dose by -0.15, the mean homogeneity index by -0.09. The exposure of organs at risk was not substantially altered. At the second brachytherapy, all patients could be treated by the preplan; the differences between the implant quality parameters were less pronounced. The changes of prostate geometry between preplans and postplans were considerable, the differences in volume ranging from -8.0 to 13.8 cm(3) and in dimensions (width, height, length) from -1.1 to 1.0 cm. CONCLUSION: Preplanning in HDR brachytherapy of the prostate is associated with a substantial decrease of dosimetric implant quality, when the preplan is based on a pretherapeutic ultrasound. The implant quality is less impaired in subsequent implants of fractionated brachytherapy.
Resumo:
With a steady increase of regulatory requirements for business processes, automation support of compliance management is a field garnering increasing attention in Information Systems research. Several approaches have been developed to support compliance checking of process models. One major challenge for such approaches is their ability to handle different modeling techniques and compliance rules in order to enable widespread adoption and application. Applying a structured literature search strategy, we reflect and discuss compliance-checking approaches in order to provide an insight into their generalizability and evaluation. The results imply that current approaches mainly focus on special modeling techniques and/or a restricted set of types of compliance rules. Most approaches abstain from real-world evaluation which raises the question of their practical applicability. Referring to the search results, we propose a roadmap for further research in model-based business process compliance checking.
Resumo:
This article attempts to analyse and investigate the implications of the approach to the applicability of Article XX GATT adopted in the recent China – Raw Materials. Using the decision on the non-availability of Article XX defences for violations of China’s WTO-plus commitments on export duties as a backdrop, it scrutinizes the more general, ‘systemic’ approach to the applicability of Article XX exceptions developed by theWTO dispute settlement bodies, and sheds light on the implications of such approach with respect to the relationship between GATT 1994 andWTO obligations arising from different instruments of theWTOAgreement, such as new members’ accession protocols. It also suggests that an exception to this general approach could be envisaged when the fundamental environmental goals protected under Article XX b) and g) are at stake.
Resumo:
PURPOSE The goal of this study was to investigate whether different computed tomography (CT) energy levels could supply additional information for the differentiation of dental materials for forensic investigations. METHODS Nine different commonly used restorative dental materials were investigated in this study. A total of 75 human third molars were filled with the restorative dental materials and then scanned using the forensic reference phantom in singlesource mode. The mean Hounsfield unit values and standard deviations (SDs) of each material were calculated at 120, 80 and 140 kVp. RESULTS Most of the dental materials could be differentiated at 120 kVp. We found that greater X-ray density of a material resulted in higher SDs and that the material volume could influence the measurements. CONCLUSION Differentiation of dental materials in CT was possible in many cases using single-energy CT scans at 120 kVp. Because of the number of dental restorative materials available and scanner and scan parameter dependence, as well as the CT imaging artifacts, the identification (in contrast to differentiation) was problematic.
Resumo:
Femoro-patellar dysplasia is considered as a significant risk factor of patellar instability. Different studies suggest that the shape of the trochlea is already developed in early childhood. Therefore early identification of a dysplastic configuration might be relevant information for the treating physician. An easy applicable routine screening of the trochlea is yet not available. The purpose of this study was to establish and evaluate a screening method for femoro-patellar dysplasia using 3D ultrasound. From 2012 to 2013 we prospectively imaged 160 consecutive femoro-patellar joints in 80 newborns from the 36th to 61st gestational week that underwent a routine hip sonography (Graf). All ultrasounds were performed by a pediatric radiologist with only minimal additional time to the routine hip ultrasound. In 30° flexion of the knee, axial, coronal, and sagittal reformats were used to standardize a reconstructed axial plane through the femoral condyle and the mid-patella. The sulcus angle, the lateral-to-medial facet ratio of the trochlea and the shape of the patella (Wiberg Classification) were evaluated. In all examinations reconstruction of the standardized axial plane was achieved, the mean trochlea angle was 149.1° (SD 4.9°), the lateral-to-medial facet ratio of the trochlea ratio was 1.3 (SD 0.22), and a Wiberg type I patella was found in 95% of the newborn. No statistical difference was detected between boys and girls. Using standardized reconstructions of the axial plane allows measurements to be made with lower operator dependency and higher accuracy in a short time. Therefore 3D ultrasound is an easy applicable and powerful tool to identify trochlea dysplasia in newborns and might be used for screening for trochlea dysplasia.
Resumo:
According to the World Health Organization, 15 million people suffer stroke worldwide each year, of these, 5 million die and 5 million are permanently disabled. Stroke is therefore a major cause of mortality world-wide. The majority of strokes are caused by a blood clot that occludes an artery in the brain, and although thrombolytic agents such as Alteplase are used to dissolve clots that arise in the arteries of the brain, there are limitations on the use of these thrombolytic agents. However over the past decade, other methods of treatment have been developed which include Thrombectomy Devices e.g. the 'GP' Thrombus Aspiration Device ('GP' TAD). Such devices may be used as an alternative to thrombolytics or in conjunction with them to extract blood clots in arteries such as the middle cerebral artery of the midbrain brain, and the posterior inferior cerebellar artery (PICA) of the posterior aspect of the brain. In this paper, we mathematically model the removal of blood clots using the 'GP' TAD from selected arteries of the brain where blood clots may arise taking into account factors such as the resistances, compliances and inertances effects. Such mathematical modelling may have potential uses in predicting the pressures necessary to extract blood clots of given lengths, and masses from arteries in the Circle of Willis - posterior circulation of the brain
Resumo:
CEN standards have helped to harmonize analytical methods for substrate analysis.Though, for special substrates or constituents the applicability might be Iimited. In this paper a comparative study of implementation of CEN standards to samples of pine bark and vermiculite has been carried out. For composted pine bark, an elongation of the equilibrium period up to 72 instead of 48 hours might increase the accuracy of determinations physical parameters according to EN 13041. For vermiculite, we suggest pycnometry as a feasible technique for the determination of particle density (PD), as the determination of organic matter (OM) as requested by EN 13041 for the calculation of the PD seems not to be applicable for this kind of material.
Resumo:
In this paper, the applicability of the FRA technique is discussed as a method for detecting inter-turn faults in stator windings. Firstly, this method is tested in an individual medium-voltage stator coil with satisfactory results. Secondly, the tests are extended to a medium-voltage induction motor stator winding, in which inter-turn faults are performed in every coil end of one phase. Results of the frequency response in case of inter-turn faults are evaluated in both cases for different fault resistance values. The experimental setup is also described for each experiment. The results of the application of this technique to the detection of inter-turn faults justify further research in optimizing this technique for preventive maintenance.
Resumo:
We report high resolution solution 19F NMR spectra of fluorine-labeled rhodopsin mutants in detergent micelles. Single cysteine substitution mutants in the cytoplasmic face of rhodopsin were labeled by attachment of the trifluoroethylthio (TET), CF3-CH2-S, group through a disulfide linkage. TET-labeled cysteine mutants at amino acid positions 67, 140, 245, 248, 311, and 316 in rhodopsin were thus prepared. Purified mutant rhodopsins (6–10 mg), in dodecylmaltoside, were analyzed at 20°C by solution 19F NMR spectroscopy. The spectra recorded in the dark showed the following chemical shifts relative to trifluoroacetate: Cys-67, 9.8 ppm; Cys-140, 10.6 ppm; Cys-245, 9.9 ppm; Cys-248, 9.5 ppm; Cys-311, 9.9 ppm; and Cys-316, 10.0 ppm. Thus, all mutants showed chemical shifts downfield that of free TET (6.5 ppm). On illumination to form metarhodopsin II, upfield changes in chemical shift were observed for 19F labels at positions 67 (−0.2 ppm) and 140 (−0.4 ppm) and downfield changes for positions 248 (+0.1 ppm) and 316 (+0.1 ppm) whereas little or no change was observed at positions 311 and 245. On decay of metarhodopsin II, the chemical shifts reverted largely to those originally observed in the dark. The results demonstrate the applicability of solution 19F NMR spectroscopy to studies of the tertiary structures in the cytoplasmic face of intact rhodopsin in the dark and on light activation.