959 resultados para XAD7 IMPREGNATED RESINS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ion-exchange chromatography has emerged as a practical and rapid method of separation and analysis. A review of literature on chelating resins reveals that eventhough investigations on highly selective resins are intensively pursued from early 1940s, such resins are still insufficiently used in analytical chemistry and process technology. This is mainly due to the complexity of their synthesis and high cost. In this context, it is worthwhile to develop novel chelating resins which are specific or at least selective towards a group of metal ions. Synthesis, characterization and analytical applications of two such resins are presented in this thesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modifications of DGEBA Using Epoxidised Resins

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dins dels processos de recuperació de metalls de dissolucions diluïdes s'ha realitzat un estudi del procés d'extracció d'or i de zinc mitjançant resines amberlite XAD-2 impregnades amb sulfur de triisobutil fosfina (TIBPS) i àcid di-(2-etilhexil) fosfòric (DEHPA) respectivament. S'ha realitzat un estudi de l'equilibri de l'adsorció d'espècies metàl·liques d'aquests metalls amb les resines indicades anteriorment. Amb la metodologia emprada per a la determinació dels punts d'equilibri dels experiments en batch i en columna, s'ha vist que una única isoterma no podia descriure el fenomen global d'equilibri i que en funció de la metodologia emprada s'obtenien isotermes diferents. Es va introduir una nova variable per poder explicar el fenomen observat, i per tant, amb aquesta nova variable l'equació de la isoterma es converteix amb l'equació d'una supèrfície que s'ha definit com a Superfície d'Equilibri. S'han determinat les equacions de les Suprfícies d'Equilibri dels sistemes d'adsorció estudiats (Au(III) TIBPS/XAD-2 i Zn(II) DEHPA/XAD-2) observan una bona coincidència de tots els punts d'equilibri obtinguts sobre la superfície, així com, un bon ajust de totes les isotermes obtingudes en funció de les diferents metodologies emprades sobre les respectives superfícies d'equilibri. Aquest nou concepte generalitza el concepte d'isoterma d'un procés d'adsorció. Fimalment, s'ha plantejat un model matemàtic d'adsorció per a determinar el coeficient efectiu de difusió (De) i el coeficient de transferància de matèria (kf) per ambdós sistemes d'adsorció estudiats mitjançant l'aplicació del model de difusió de sòlid homogeni (HSDM), utilitzant com a condició de contorn en el model la isoterma de Langmuir obtinguda mitjançant els experiments en columna de llit fix i emprant també l'equació obtinguda mitjançant el nou concepte de Superfície d'Equilibri. Els resultats obtinguts són molt satisfactoris, per tant, es pot concloure que la Superfície d'Equilibri és una bona eina per a descriure l'equilibri en els processos d'adsorció d'or i zinc amb les resines amberlite XAD-2 impregnades amb TIBPS i DEHPA respectivament.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lactoperoxidase (LP) was isolated from whey protein by cation-exchange using Carboxymethyl resin (CM-25C) and Sulphopropyl Toyopearl resin (SP-650C). Both batch and column procedures were employed and the adsorption capacities and extraction efficiencies were compared. The resin bed volume to whey volume ratios were 0.96:1.0 for CM-25C and ≤ 0.64:1.0 for SP-650 indicating higher adsorption capacity of SP-650 compared to CM-25C. The effluent LP activity depended on both the enzyme activity in the whey and the amount of whey loaded on the column within the saturation limits of the resin. The percentage recovery was high below the saturation point and fell off rapidly with over-saturation. While effective recovery was achieved with column extraction procedures, the recovery was poor in batch procedures. The whey-resin contact time had little impact on the enzyme adsorption. SDS PAGE and HPLC analyses were also carried out, the purity was examined and the proteins characterised in terms of molecular weights. Reversed phase HPLC provided clear distinction of the LP and lactoferrin (LF) peaks. The enzyme purity was higher in column effluents compared to batch effluents, judged on the basis of the clarity of the gel bands and the resolved peaks in HPLC chromatograms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We previously found that dried live bacteria of a vaccine strain can be temporarily sensitive to bile acids and suggested that Bile Adsorbing Resins (BAR) can be used in oral vaccine tablets to protect dried bacteria from intestinal bile. Here, we report a quantitative analysis of the ability of BAR to exclude the dye bromophenol blue from penetrating into matrix tablets and also sections of hard capsule shells. Based on this quantitative analysis, we made a fully optimised formulation, comprising 25% w/w of cholestyramine in Vcaps™ HPMC capsules. This gave effectively 100% protection of viability from 4% bile, with 4200-fold more live bacteria recovered from this formulation compared to unprotected dry bacteria. From the image analysis, we found that the filler material or compaction force used had no measurable effect on dye exclusion but did affect the rate of tablet hydration. Increasing the mass fraction of BAR gave more exclusion of dye up to 25% w/w, after which a plateau was reached and no further dye exclusion was seen. More effective dye exclusion was seen with smaller particle sizes (i.e. cholestyramine) and when the BAR was thoroughly dried and disaggregated. Similar results were found when imaging dye penetration into capsule sections or tablets. The predictions of the dye penetration study were tested using capsules filled with dried attenuated Salmonella vaccine plus different BAR types, and the expected protection from bile was found, validating the imaging study. Surprisingly, depending on the capsule shell material, some protection was given by the capsule alone without adding BAR, with Vcaps™ HPMC capsules providing up to 174-fold protection against 1% bile; faster releasing Vcaps Plus™ HPMC capsules and Coni Snap™ gelatin capsules gave less protection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We previously demonstrated that a dry, room temperature stable formulation of a live bacterial vaccine was highly susceptible to bile, and suggested that this will lead to significant loss of viability of any live bacterial formulation released into the intestine using an enteric coating or capsule. We found that bile and acid tolerance is very rapidly recovered after rehydration with buffer or water, raising the possibility that rehydration in the absence of bile prior to release into the intestine might solve the problem of bile toxicity to dried cells. We describe here a novel formulation that combines extensively studied bile acid adsorbent resins with the dried bacteria, to temporarily adsorb bile acids and allow rehydration and recovery of bile resistance of bacteria in the intestine before release. Tablets containing the bile acid adsorbent cholestyramine release 250-fold more live bacteria when dissolved in a bile solution, compared to control tablets without cholestyramine or with a control resin that does not bind bile acids. We propose that a simple enteric coated oral dosage form containing bile acid adsorbent resins will allow improved live bacterial delivery to the intestine via the oral route, a major step towards room temperature stable, easily administered and distributed vaccine pills and other bacterial therapeutics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Near-perfect vector phase conjugation was achieved at 488 nm in a methyl red dye impregnated polymethylmethacrylate film by employing a temperature tuning technique. Using a degenerate four-wave mixing geometry with vertically polarized counterpropagating pump beams, intensity and polarization gratings were written in the dye/polymer system using a vertically or horizontally polarized weak probe beam. Over a limited temperature range, as the sample was heated, the probe reflectivity from the polarization grating dropped but the reflectivity from the intensity grating rose sharply. At a sample temperature of approximately 50°C, the reflectivities of the gratings were measured to be equal and we confirmed that, at this temperature, the measured vector phase conjugate fidelity was very close to unity. We discuss a possible explanation of this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enteric coated oral tablets or capsules can deliver dried live cells directly into the intestine. Previously, we found that a live attenuated bacterial vaccine acquired sensitivity to intestinal bile when dried, raising the possibility that although gastric acid can be bypassed, significant loss of viability might occur on release from an enteric coated oral formulations. Here we demonstrate that some food-grade lyophilised preparations of Lactobacillus casei and Lactobacillus salivarius also show temporary bile sensitivity that can be rapidly reversed by rehydration. To protect dried bacterial cells from temporary bile sensitivity, we propose using bile acid adsorbing resins, such as cholestyramine, which are bile acid binding agents, historically used to lower cholesterol levels. Vcaps™ HPMC capsules alone provided up to 830-fold protection from bile. The inclusion of 50% w/w cholestyramine in Vcaps™ HPMC capsules resulted in release of up to 1700-fold more live Lactobacillus casei into simulated intestinal fluid containing 1% bile, when compared to dried cells added directly to bile. We conclude that delivery of dried live probiotic organisms to the intestine may be improved by providing protection from bile by addition of bile adsorbing resins and the use of HPMC capsules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this in vitro study was to evaluate the antimicrobial activity of acrylic resins containing different percentages of silver and zinc zeolite, and to assess whether the addition of zeolite alters the flexural and impact strength of the resins. Background: The characteristics of acrylic resins support microorganism development that can threaten the health of the dentures user. Material and methods: A microwave-polymerised (Onda-Cryl) and two heat-polymerised (QC20 and Lucitone 550) acrylic resins were used. The materials were handled according to the manufacturers` instructions. Fifty rectangular-shaped specimens (8 x 10 x 4mm) were fabricated from each resin and assigned to 5 groups (n = 10) according to their percentage of Irgaguard B5000 silver-zinc zeolite (0%- control, 2.5%, 5.0%, 7.5% and 10%). Flexural strength and Izod impact strength were evaluated. The antimicrobial activity against two strains of Candida albicans and two strains of Streptococcus mutans was assessed by agar diffusion method. Data were analysed statistically by one-way ANOVA and Tukey`s test at 5% significance level. Results: The addition of 2.5% of Irgaguard B5000 to the materials resulted in antimicrobial activity against all strains. Flexural strength decreased significantly with the addition of 2.5% (QC20 and Lucitone 550) and 5.0% (Onda-Cryl) of Irgaguard B5000. The impact strength decreased significantly with the addition of 2.5% (Lucitone 550) and 5.0% (QC20 and Onda-Cryl) of zeolite. Conclusion: The addition of silver-zinc zeolite to acrylic resins yields antimicrobial activity, but may affect negatively the mechanical properties, depending on the percentage of zeolite.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The method of porosity analysis by water absorption has been carried out by the storage of the specimens in pure water, but it does not exclude the potential plasticising effect of the water generating unreal values of porosity. Objective: The present study evaluated the reliability of this method of porosity analysis in polymethylmethacrylate denture base resins by the determination of the most satisfactory solution for storage (S), where the plasticising effect was excluded. Materials and methods: Two specimen shapes (rectangular and maxillary denture base) and two denture base resins, water bath-polymerised (Classico) and microwave-polymerised (Acron MC) were used. Saturated anhydrous calcium chloride solutions (25%, 50%, 75%) and distilled water were used for specimen storage. Sorption isotherms were used to determine S. Porosity factor (PF) and diffusion coefficient (D) were calculated within S and for the groups stored in distilled water. anova and Tukey tests were performed to identify significant differences in PF results and Kruskal-Wallis test and Dunn multiple comparison post hoc test, for D results (alpha = 0.05). Results: For Acron MC denture base shape, FP results were 0.24% (S 50%) and 1.37% (distilled water); for rectangular shape FP was 0.35% (S 75%) and 0.19% (distilled water). For Classico denture base shape, FP results were 0.54% (S 75%) and 1.21% (distilled water); for rectangular shape FP was 0.7% (S 50%) and 1.32% (distilled water). FP results were similar in S and distilled water only for Acron MC rectangular shape (p > 0.05). D results in distilled water were statistically higher than S for all groups. Conclusions: The results of the study suggest that an adequate solution for storing specimens must be used to measure porosity by water absorption, based on excluding the plasticising effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Physical and bioceramic incorporation surface treatments at the nanometer scale showed higher means of bone-to-implant contact (BIC) and torque values compared with surface topography at the micrometer scale; however, the literature concerning the effect of nanometer scale parameters is sparse. Purpose: The aim of this study was to evaluate the influence of two different implant surfaces on the percentage bone-to-implant contact (BIC%) and bone osteocyte density in the human posterior maxilla after 2 months of unloaded healing. Materials and Methods: The implants utilized presented dual acid-etched (DAE) surface and a bioceramic molecular impregnated treatment (Ossean(R), Intra-Lock International, Boca Raton, FL, USA) serving as control and test, respectively. Ten subjects (59 1 9 years of age) received two implants (one of each surface) during conventional implant surgery in the posterior maxilla. After the non-loaded period of 2 months, the implants and the surrounding tissue were removed by means of a trephine and were non-decalcified processed for ground sectioning and analysis of BIC%, bone density in threaded area (BA%), and osteocyte index (Oi). Results: Two DAE implants were found to be clinically unstable at time of retrieval. Histometric evaluation showed significantly higher BIC% and Oi for the test compared to the control surface (p < .05), and that BA% was not significantly different between groups. Wilcoxon matched pairs test was used to compare the differences of histomorphometric variables between implant surfaces. The significance test was conducted at a 5% level of significance. Conclusion: The histological data suggest that the bioceramic molecular impregnated surface-treated implants positively modulated bone healing at early implantation times compared to the DAE surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated the thermal and structural properties of different commercial dental resins: Filtek(TM) Z-350, Grandio(A (R)), Tetric Ceram(A (R)), and TPH Spectrum(A (R)). The purpose of the present study was to evaluate quantitatively the photo-polymerization behavior and the effect of filler contents on the kinetic cures of the dental resins by using Differential Scanning Calorimetry (DSC) and Fourier Transform Infrared Spectroscopy (FT-IR) techniques. We have successfully obtained the low and high glass transition T (g) values of the dental composite resins from DSC curves. It was also observed a good agreement between the both T (g) values, activation energies from thermal degradation, and the degree of conversion obtained for all samples. The results have shown that Tetric Ceram(A (R)) dental resin presented the higher T (g) values, activation energy of 215 +/- A 6 KJ mol(-1), and the higher degree of conversion (63%) when compared to the other resins studied herein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural and thermal properties of three different dental composite resins, Filtek (TM) Supreme XT, Filtek (TM) Z-250 and TPHA (R)(3) were investigated in this study. The internal structures of uncured and cured resins with blue light-emitting diodes (LEDs) were examined by Micro-Raman spectroscopy. Thermal analysis techniques as DSC, TG and DTG methods were used to investigate the temperature characteristics, as glass transition (T (g) ), degradation, and the thermal stability of the resins. The results showed that the TPHA (R)(3) and Filtek (TM) Supreme XT presented very similar T (g) values, 48 and 50A degrees C, respectively, while the Filtek (TM) Z-250 composite resin presented a higher one, 58A degrees C. AFM microscope was utilized in order to analyze the sample morphologies, which possess different fillers. The composed resin Filtek (TM) Z-250 has a well interconnected more homogeneous morphology, suggesting a better degree of conversion correlated to the glass phase transition temperature. The modes of vibration of interest in the resin were investigated using Raman spectroscopy. It was possible to observe the bands representative for the C=C (1630 cm(-1)) and C=O(1700 cm(-1)) vibrations were studied with respect to their compositions and polymerization. It was observed that the Filtek (TM) Z -250 resin presents the best result related to the thermal properties and polymerization after light curing among the other resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal properties and degree of conversion (DC%) of two composite resins (microhybrid and nanocomposite) and two photo-activation methods (continuous and gradual) displayed by the light-emitting diode (LED) light-curing units (LCUs) were investigated in this study. Differential scanning calorimetry (DSC) thermal analysis technique was used to investigate the glass transition temperature (T(g)) and degradation temperature. The DC% was determined by Fourier transform infrared spectroscopy (FT-IR). The results showed that the microhybrid composite resin presented the highest T(g) and degradation temperature values, i.e., the best thermal stability. Gradual photo-activation methods showed higher or similar T(g) and degradation temperature values when compared to continuous method. The Elipar Freelight 2 (TM) LCU showed the lowest T(g) values. With respect to the DC%, the photo-activation method did not influence the final conversion of composite resins. However, Elipar Freelight 2 (TM) LCU and microhybrid resin showed the lowest DC% values. Thus, the presented results suggest that gradual method photo-activation with LED LCUs provides adequate degree of conversion without promoting changes in the polymer chain of composite resins. However, the thermal properties and final conversion of composite resins can be influenced by the kind of composite resin and LCU.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dental composite resins possess good esthetic properties, and are currently among the most popular dental restorative materials. Both organic and inorganic phases might influence the material behavior, the filler particle features and rate are the most important factors related to improvement of the mechanical properties of resin composites. Thus, the objective of this study was to evaluate the effect of three different composite resins on the polymerization process by Vickers hardness test. The samples were prepared using three different composite resins, as follow: group I-P-60 (3M/ESPE); group II-Herculite XRV (Kerr), and group III-Durafill (Heraeus-Kulzer). The samples were made in a polytetrafluoroethylene mould, with a rectangular cavity measuring 7 mm in length, 4 mm in width, and 3 mm in thickness. The samples were photo-activated by one light-curing unit based on blue LEDs (Ultrablue III-DMC/Brazil) for 20 and 40 s of irradiation times. The Vickers hardness test was performed 24 h after the photo-activation until the standardized depth of 3 mm. The Vickers hardness mean values varied from 158.9 (+/- 0.81) to 81.4 (+/- 1.94) for P-60, from 138.7 (+/- 0.37) to 61.7 (+/- 0.24) for Herculite XRV, and from 107. 5 (+/- 0.81) to 44.5 (+/- 1.36) for Durafill composite resins photo-activated during 20 s for the 1st and 2nd mm, respectively. During 40 s of photo-activation, the Vickers hardness mean values were: from 181.0 (+/- 0.70) to 15.6 (+/- 0.29) for P-60, and from 161.8 (+/- 0.41) to 11.2 (+/- 0.17) for Herculite XRV composite resins, for the 1st and 3th mm, respectively. For Durafill composite resin the mean values varied from 120.1 (+/- 0.66) to 61.7 (+/- 0.20), for the 1st and 2nd mm, respectively. The variation coefficient (CV) was in the most of the groups lower than 1%, then the descriptive statistic analysis was used. The Vickers hardness mean values for Durafill were lower than P-60 and Herculite XRV composite resins for 20 and 40 s of irradiation time. The polymerization process was greatly affected by the composition of the composite resins.