979 resultados para Thoracic computed tomography scan


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Surgical repair of pectus excavatum (PE) has become more popular due to improvements in the minimally invasive Nuss procedure. The pre-surgical assessment of PE patients requires Computerized Tomography (CT), as the malformation characteristics vary from patient to patient. Objective: This work aims to characterize soft tissue thickness (STT) external to the ribs among PE patients. It also presents a comparative analysis between the anterior chest wall surface before and after surgical correction. Methods: Through surrounding tissue segmentation in CT data, STT values were calculated at different lines along the thoracic wall, with a reference point in the intersection of coronal and median planes. The comparative analysis between the two 3D anterior chest surfaces sets a surgical correction influence area (SCIA) and a volume of interest (VOI) based on image processing algorithms, 3D surface algorithms, and registration methods. Results: There are always variations between left and right side STTs (2.54±2.05 mm and 2.95±2.97 mm for female and male patients, respectively). STTs are dependent on age, sex, and body mass index of each patient. On female patients, breast tissue induces additional errors in bar manual

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Surgical repair of pectus excavatum (PE) has become more popular due to improvements in the minimally invasive Nuss procedure. The pre-surgical assessment of PE patients requires Computerized Tomography (CT), as the malformation characteristics vary from patient to patient. Objective: This work aims to characterize soft tissue thickness (STT) external to the ribs among PE patients. It also presents a comparative analysis between the anterior chest wall surface before and after surgical correction. Methods: Through surrounding tissue segmentation in CT data, STT values were calculated at different lines along the thoracic wall, with a reference point in the intersection of coronal and median planes. The comparative analysis between the two 3D anterior chest surfaces sets a surgical correction influence area (SCIA) and a volume of interest (VOI) based on image processing algorithms, 3D surface algorithms, and registration methods. Results: There are always variations between left and right side STTs (2.54±2.05 mm and 2.95±2.97 mm for female and male patients, respectively). STTs are dependent on age, sex, and body mass index of each patient. On female patients, breast tissue induces additional errors in bar manual

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To estimate the budget impact from the incorporation of positron emission tomography (PET) in mediastinal and distant staging of non-small cell lung cancer.METHODS The estimates were calculated by the epidemiological method for years 2014 to 2018. Nation-wide data were used about the incidence; data on distribution of the disease´s prevalence and on the technologies’ accuracy were from the literature; data regarding involved costs were taken from a micro-costing study and from Brazilian Unified Health System (SUS) database. Two strategies for using PET were analyzed: the offer to all newly-diagnosed patients, and the restricted offer to the ones who had negative results in previous computed tomography (CT) exams. Univariate and extreme scenarios sensitivity analyses were conducted to evaluate the influence from sources of uncertainties in the parameters used.RESULTS The incorporation of PET-CT in SUS would imply the need for additional resources of 158.1 BRL (98.2 USD) million for the restricted offer and 202.7 BRL (125.9 USD) million for the inclusive offer in five years, with a difference of 44.6 BRL (27.7 USD) million between the two offer strategies within that period. In absolute terms, the total budget impact from its incorporation in SUS, in five years, would be 555 BRL (345 USD) and 600 BRL (372.8 USD) million, respectively. The costs from the PET-CT procedure were the most influential parameter in the results. In the most optimistic scenario, the additional budget impact would be reduced to 86.9 BRL (54 USD) and 103.8 BRL (64.5 USD) million, considering PET-CT for negative CT and PET-CT for all, respectively.CONCLUSIONS The incorporation of PET in the clinical staging of non-small cell lung cancer seems to be financially feasible considering the high budget of the Brazilian Ministry of Health. The potential reduction in the number of unnecessary surgeries may cause the available resources to be more efficiently allocated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Marked regional variations in myocardial activity that are not related to myocardial perfusion defects.Verify the influence of CT-AC inMPI results in patients with BMI between 30 and 35 and higher than 30 for male and female population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Intensive image surveillance after endovascular aneurysm repair is generally recommended due to continued risk of complications. However, patients at lower risk may not benefit from this strategy. We evaluated the predictive value of the first postoperative computed tomography angiography (CTA) characteristics for aneurysm-related adverse events as a means of patient selection for risk-adapted surveillance. METHODS: All patients treated with the Low-Permeability Excluder Endoprosthesis (W. L. Gore & Assoc, Flagstaff, Ariz) at a tertiary institution from 2004 to 2011 were included. First postoperative CTAs were analyzed for the presence of endoleaks, endograft kinking, distance from the lowermost renal artery to the start of the endograft, and for proximal and distal sealing length using center lumen line reconstructions. The primary end point was freedom from aneurysm-related adverse events. Multivariable Cox regression was used to test postoperative CTA characteristics as independent risk factors, which were subsequently used as selection criteria for low-risk and high-risk groups. Estimates for freedom from adverse events were obtained using Kaplan-Meier survival curves. RESULTS: Included were 131 patients. The median follow-up was 4.1 years (interquartile range, 2.1-6.1). During this period, 30 patients (23%) sustained aneurysm-related adverse events. Seal length <10 mm and presence of endoleak were significant risk factors for this end point. Patients were subsequently categorized as low-risk (proximal and distal seal length ≥10 mm and no endoleak, n = 62) or high-risk (seal length <10 mm or presence of endoleak, or both; n = 69). During follow-up, four low-risk patients (3%) and 26 high-risk patients (19%) sustained events (P < .001). Four secondary interventions were required in three low-risk patients, and 31 secondary interventions in 23 high-risk patients. Sac growth was observed in two low-risk patients and in 15 high-risk patients. The 5-year estimates for freedom from aneurysm-related adverse events were 98% for the low-risk group and 52% for the high-risk group. For each diagnosis, 81.7 image examinations were necessary in the low-risk group and 8.2 in the high-risk group. CONCLUSIONS: Our results suggest that the first postoperative CTA provides important information for risk stratification after endovascular aneurysm repair when the Excluder endoprosthesis is used. In patients with adequate seal and no endoleaks, the risk of aneurysm-related adverse events was significantly reduced, resulting in a large number of unnecessary image examinations. Adjusting the imaging protocol beyond 30 days and up to 5 years, based on individual patients' risk, may result in a more efficient and rational postoperative surveillance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMO:Os recentes progressos na imagiologia médica possibilitaram um papel de destaque para a Tomografia Axial Computorizada Multicorte no estadiamento do carcinoma do estômago (GA). Foi objetivo deste estudo avaliar a acuidade desta técnica no estadiamento T (invasão mural) e N (ganglionar) e avaliar fatores de prognóstico como fatores de representação/substituição para melhorar a referida acuidade. Sessenta e nove pacientes operados a carcinoma gástrico (GA) entre Janeiro de 2010 e Julho de 2012 e avaliados por Tomografia Computorizada, a maioria recorrendo a técnica de multicorte com distensão gástrica, foram estadiados retrospetivamente por três imagiologistas. Utilizaram-se critérios de avaliação referidos na literatura especializada e fatores de substituição/representação nos estadios menos eficazes. O estadiamento T revelou acuidade de 66,7% e sensibilidade de 92% e a acuidade, sensibilidade e especificidade obtidas para o estadiamento N foram respetivamente 49%, 40,9% e 64%. Usando um fator de substituição de estadiamento diagnóstico T4/N2 para mudar o estadiamento N2 obtido por MDCT para estadiamento N3A aumentaria a acuidade do estadiamento N para 59% e a sensibilidade para 58,1% e baixaria a especificidade para 61,5%, embora essa mudança não fosse estatisticamente significativa (Teste exato de Fisher 0,159). Em conclusão a acuidade de uma técnica simples de MDCT com distensão gástrica no estadiamento T e N do GA está dentro dos valores citados na literatura e fatores de substituição/representação como o estadiamento T4 e o tipo Difuso da classificação de Lauren podem melhorar a acuidade do estadiamento N.-------------- ABSTRACT: Recent innovations in medical sectional imaging have allowed a major role of multi-detector computed tomography (MDCT) in staging of gastric adenocarcinoma (GA). The purpose of this study was to evaluate the accuracy of this technique in depth of mural invasion (T) and nodal (N) staging of GA and to evaluate prognostic factors as surrogate factors to improve such accuracy. Sixty nine patients operated to GA between January 2010 and July 2012 that underwent Computed Tomography, the majority through Multidetector Computed Tomography (MDCT) with gastric distention, were staged retrospectively by three imagiologists with state-of-the-art criteria and surrogate prognostic factors were analyzed for less accurate stages. MDCT T-staging was 66,7 % accurate with a sensibility of 92 % and there was a 49 % accuracy, 40,9 % sensibility and 64 % specificity for N Staging. Using a surrogate factor of T4/N2 diagnostic staging to change diagnostic MDCT N2 disease to N3A disease would increase accuracy of N staging to 59% and sensibility to 58,1% and would decrease specificity to 61,5 %, although that change was not statistically significant (Fisher´s Exact Test 0,159)In conclusion the accuracy of a simple hydro-MDCT technique in T and N staging of GA is in the range of values cited in the literature and surrogate factors as diagnostic T4 disease and diffuse type of Lauren´s Classification may improve the accuracy of N staging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To report the experience of a radiology department in the use of computed tomography guided biopsies of mediastinal lesions with fine and cutting needles, describing the differences between them. The results of adequacy of the sample and histologic diagnoses are presented according to the type of needle used. METHODS: We present a retrospective study of mediastinal biopsies guided by computed tomography performed from January 1993 to December 1999. Eighty-six patients underwent mediastinal biopsy in this period, 37 with cutting needles, 38 with fine needles, and 11 with both types (total of 97 biopsies). RESULTS: In most cases, it was possible to obtain an adequate sample (82.5%) and specific diagnosis (67.0%). Cutting-needle biopsy produced a higher percentage of adequate samples (89.6% versus 75.5%, P = 0.068) and of specific diagnosis (81.3% versus 53.1%, P = 0.003) than fine-needle biopsy. There were no complications that required intervention in either group. CONCLUSION: Because they are practical, safe, and can provide accurate diagnoses, image-guided biopsies should be considered the procedure of choice in the initial exploration of patients with mediastinal masses. In our experience, cutting needles gave higher quality samples and diagnostic rates. We recommend the use of cutting needles as the preferred procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the relation between coronary artery disease and the calcification index on helical computed tomography. METHOD: We studied 22 patients (ages ranging from 40 to 70 years) who underwent coronary angiography because of chest pain suggestive of angina pectoris. Findings on coronary angiography were classified as follows: significant obstructive disease (stenosis > or = 50%), nonobstructive disease (stenosis <50%), and no disease. With no previous knowledge of the results of the coronary angiography and within 7 days, helical computed tomography of the chest was performed. Then, data of the coronary angiography were correlated with the calcification index obtained by helical computed tomography. RESULTS: The sensitivity of helical computed tomography to the presence of significant obstructive lesions on coronary angiography was 87.5%, specificity was 100%, and negative and positive predictive values were 75% and 100%, respectively. The mean calcification index was greater in patients with severe coronary lesions, mainly when involvement of 2 or 3 vessels occurred, than that in patients with no coronary artery disease or with nonobstructive coronary artery lesions (p<0.05). CONCLUSION: Helical computed tomography is an effective method for detecting and quantifying coronary artery calcification, and it has proved to be sensitive to and specific for the noninvasive diagnosis of coronary artery stenosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Systemic Arterial Hypertension (SAH) is one of the main risk factors for Coronary Artery Disease (CAD), in addition to male gender. Differences in coronary artery lesions between hypertensive and normotensive individuals of both genders at the Coronary Computed Tomography Angiography (CCTA) have not been clearly determined. Objective: To Investigate the calcium score (CS), CAD extent and characteristics of coronary plaques at CCTA in men and women with and without SAH. Methods: Prospective cross-sectional study of 509 patients undergoing CCTA for CAD diagnosis and risk stratification, from November 2011 to December 2012, at Instituto de Cardiologia Dante Pazzanese. Individuals were stratified according to gender and subdivided according to the presence (HT +) or absence (HT-) of SAH. Results: HT+ women were older (62.3 ± 10.2 vs 57.8 ± 12.8, p = 0.01). As for the assessment of CAD extent, the HT+ individuals of both genders had significant CAD, although multivessel disease is more frequent in HT + men. The regression analysis for significant CAD showed that age and male gender were the determinant factors of multivessel disease and CS ≥ 100. Plaque type analysis showed that SAH was a predictive risk factor for partially calcified plaques (OR = 3.9). Conclusion: Hypertensive men had multivessel disease more often than women. Male gender was a determinant factor of significant CAD, multivessel disease, CS ≥ 100 and calcified and partially calcified plaques, whereas SAH was predictive of partially calcified plaques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background: Functional tests have limited accuracy for identifying myocardial ischemia in patients with left bundle branch block (LBBB). Objective: To assess the diagnostic accuracy of dipyridamole-stress myocardial computed tomography perfusion (CTP) by 320-detector CT in patients with LBBB using invasive quantitative coronary angiography (QCA) (stenosis ≥ 70%) as reference; to investigate the advantage of adding CTP to coronary computed tomography angiography (CTA) and compare the results with those of single photon emission computed tomography (SPECT) myocardial perfusion scintigraphy. Methods: Thirty patients with LBBB who had undergone SPECT for the investigation of coronary artery disease were referred for stress tomography. Independent examiners performed per-patient and per-coronary territory assessments. All patients gave written informed consent to participate in the study that was approved by the institution’s ethics committee. Results: The patients’ mean age was 62 ± 10 years. The mean dose of radiation for the tomography protocol was 9.3 ± 4.6 mSv. With regard to CTP, the per-patient values for sensitivity, specificity, positive and negative predictive values, and accuracy were 86%, 81%, 80%, 87%, and 83%, respectively (p = 0.001). The per-territory values were 63%, 86%, 65%, 84%, and 79%, respectively (p < 0.001). In both analyses, the addition of CTP to CTA achieved higher diagnostic accuracy for detecting myocardial ischemia than SPECT (p < 0.001). Conclusion: The use of the stress tomography protocol is feasible and has good diagnostic accuracy for assessing myocardial ischemia in patients with LBBB.