990 resultados para Testing Procedure


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper concerns the development of drives that use electromechanical rotative motor systems. It is proposed an experimental drive test structure integrated to simulation softwares. The objective of this work is to show that an affordable model validation procedure can be obtained by combining a precision data acquisition with well tuned state-of-the-art simulation packages. This is required for fitting, in the best way, a drive to its load or, inversely, to adapt loads to given drive characteristics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Controversy exists regarding the diagnostic accuracy, optimal technique, and timing of exercise testing after percutaneous coronary intervention. The objectives of the present study were to analyze variables and the power of exercise testing to predict restenosis or a new lesion, 6 months after the procedure. Eight-four coronary multi-artery diseased patients with preserved ventricular function were studied (66 males, mean age of all patients: 59 ± 10 years). All underwent coronary angiography and exercise testing with the Bruce protocol, before and 6 months after percutaneous coronary intervention. The following parameters were measured: heart rate, blood pressure, rate-pressure product (heart rate x systolic blood pressure), presence of angina, maximal ST-segment depression, and exercise duration. On average, 2.33 lesions/patient were treated and restenosis or progression of disease occurred in 46 (55%) patients. Significant increases in systolic blood pressure (P = 0.022), rate-pressure product (P = 0.045) and exercise duration (P = 0.003) were detected after the procedure. Twenty-seven (32%) patients presented angina during the exercise test before the procedure and 16 (19%) after the procedure. The exercise test for the detection of restenosis or new lesion presented 61% sensitivity, 63% specificity, 62% accuracy, and 67 and 57% positive and negative predictive values, respectively. In patients without restenosis, the exercise duration after percutaneous coronary intervention was significantly longer (460 ± 154 vs 381 ± 145 s, P = 0.008). Only the exercise duration permitted us to identify patients with and without restenosis or a new lesion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the user experience and usability in software application are becoming a major design issue due to the adaptation of many processes using new technologies. Therefore, the study of the user experience and usability might be included in every software development project and, thus, they should be tested to get traceable results. As a result of different testing methods to evaluate the concepts, a non-expert on the topic might have doubts on which option he/she should opt for and how to interpret the outcomes of the process. This work aims to create a process to ease the whole testing methodology based on the process created by Seffah et al. and a supporting software tool to follow the procedure of these testing methods for the user experience and usability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The motivatitni for" the present work is from .a project sanctioned by TSRO. The work involved the development of a quick and reliable test procedure using microwaves, for tflue inspection of cured propellant samples and a method to monitor the curing conditions of propellant mix undergoing the curing process.Normal testing CHE the propellant samples involvecuttimg a piece from each carton and testing it for their tensile strength. The values are then compared with standard ones and based on this result the sample isaccepted or rejected. The tensile strength is a measure ofdegree of cure of the propellant mix. But this measurementis a destructive procedure as it involves cutting of the sample. Moreover, it does not guarantee against nonuniform curing due to power failure, hot air-line failure,operator error etc. This necessitated the need for the development of a quick and reliable non-destructive test procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional method for assessing acute oral toxicity (OECD Test Guideline 401) was designed to identify the median lethal dose (LD50), using the death of animals as an endpoint. Introduced as an alternative method (OECD Test Guideline 420), the Fixed Dose Procedure (FDP) relies on the observation of clear signs of toxicity, uses fewer animals and causes less suffering. More recently, the Acute Toxic Class method and the Up-and-Down Procedure have also been adopted as OECD test guidelines. Both of these methods also use fewer animals than the conventional method, although they still use death as an endpoint. Each of the three new methods incorporates a sequential dosing procedure, which results in increased efficiency. In 1999, with a view to replacing OECD Test Guideline 401, the OECD requested that the three new test guidelines be updated. This was to bring them in line with the regulatory needs of all OECD Member Countries, provide further reductions in the number of animals used, and introduce refinements to reduce the pain and distress experienced by the animals. This paper describes a statistical modelling approach for the evaluation of acute oral toxicity tests, by using the revised FDP for illustration. Opportunities for further design improvements are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional method for the assessment of acute dermal toxicity (OECD Test Guideline 402, 1987) uses death of animals as an endpoint to identify the median lethal dose (LD50). A new OECD Testing Guideline called the dermal fixed dose procedure (dermal FDP) is being prepared to provide an alternative to Test Guideline 402. In contrast to Test Guideline 402, the dermal FDP does not provide a point estimate of the LD50, but aims to identify that dose of the substance under investigation that causes clear signs of nonlethal toxicity. This is then used to assign classification according to the new Globally Harmonised System of Classification and Labelling scheme (GHS). The dermal FDP has been validated using statistical modelling rather than by in vivo testing. The statistical modelling approach enables calculation of the probability of each GHS classification and the expected numbers of deaths and animals used in the test for imaginary substances with a range of LD50 values and dose-response curve slopes. This paper describes the dermal FDP and reports the results from the statistical evaluation. It is shown that the procedure will be completed with considerably less death and suffering than guideline 402, and will classify substances either in the same or a more stringent GHS class than that assigned on the basis of the LD50 value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The conventional method for the assessment of acute inhalation toxicity (OECD Test Guideline 403, 1981) uses death of animals as an endpoint to identify the median lethal concentration (LC50). A new OECD Testing Guideline called the Fixed Concentration Procedure (FCP) is being prepared to provide an alternative to Test Guideline 403. Unlike Test Guideline 403, the FCP does not provide a point estimate of the LC50, but aims to identify an airborne exposure level that causes clear signs of nonlethal toxicity. This is then used to assign classification according to the new Globally Harmonized System of Classification and Labelling scheme (GHS). The FCP has been validated using statistical simulation rather than byin vivo testing. The statistical simulation approach predicts the GHS classification outcome and the numbers of deaths and animals used in the test for imaginary substances with a range of LC50 values and dose response curve slopes. This paper describes the FCP and reports the results from the statistical simulation study assessing its properties. It is shown that the procedure will be completed with considerably less death and suffering than Test Guideline 403, and will classify substances either in the same or a more stringent GHS class than that assigned on the basis of the LC50 value.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to apply and compare two time-domain analysis procedures in the determination of oxygen uptake (VO2) kinetics in response to a pseudorandom binary sequence (PRBS) exercise test. PRBS exercise tests have typically been analysed in the frequency domain. However, the complex interpretation of frequency responses may have limited the application of this procedure in both sporting and clinical contexts, where a single time measurement would facilitate subject comparison. The relative potential of both a mean response time (MRT) and a peak cross-correlation time (PCCT) was investigated. This study was divided into two parts: a test-retest reliability study (part A), in which 10 healthy male subjects completed two identical PRBS exercise tests, and a comparison of the VO2 kinetics of 12 elite endurance runners (ER) and 12 elite sprinters (SR; part B). In part A, 95% limits of agreement were calculated for comparison between MRT and PCCT. The results of part A showed no significant difference between test and retest as assessed by MRT [mean (SD) 42.2 (4.2) s and 43.8 (6.9) s] or by PCCT [21.8 (3.7) s and 22.7 (4.5) s]. Measurement error (%) was lower for MRT in comparison with PCCT (16% and 25%, respectively). In part B of the study, the VO2 kinetics of ER were significantly faster than those of SR, as assessed by MRT [33.4 (3.4) s and 39.9 (7.1) s, respectively; P<0.01] and PCCT [20.9 (3.8) s and 24.8 (4.5) s; P < 0.05]. It is possible that either analysis procedure could provide a single test measurement Of VO2 kinetics; however, the greater reliability of the MRT data suggests that this method has more potential for development in the assessment Of VO2 kinetics by PRBS exercise testing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study explores how the typographic layout of information influences readers' impressions of magazine contents pages. Thirteen descriptors were used in a paired comparison procedure that assessed whether participants' rhetorical impressions of a set of six controlled documents change in relation to variations in layout. The combinations of layout attributes tested were derived from the structural attributes associated with three patterns of typographic differentiation (high, moderate, and low) described in a previous study (see Moys, 2014). The content and the range of stylistic attributes applied to the test material were controlled in order to focus on layout attributes. Triangulation of the quantitative and qualitative data indicates that, even within the experimental confines of limited stylistic differentiation, the layout attributes associated with patterns of high, moderate, and low typographic differentiation do influence readers' rhetorical judgments. In addition, the findings emphasize the importance of considering inter-relationships between clusters of typographic attributes rather than testing isolated variables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of inter-laboratory test comparisons to determine the performance of individual laboratories for specific tests (or for calibration) [ISO/IEC Guide 43-1, 1997. Proficiency testing by interlaboratory comparisons - Part 1: Development and operation of proficiency testing schemes] is called Proficiency Testing (PT). In this paper we propose the use of the generalized likelihood ratio test to compare the performance of the group of laboratories for specific tests relative to the assigned value and illustrate the procedure considering an actual data from the PT program in the area of volume. The proposed test extends the test criteria in use allowing to test for the consistency of the group of laboratories. Moreover, the class of elliptical distributions are considered for the obtained measurements. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper studies a special class of vector smooth-transition autoregressive (VSTAR) models that contains common nonlinear features (CNFs), for which we proposed a triangular representation and developed a procedure of testing CNFs in a VSTAR model. We first test a unit root against a stable STAR process for each individual time series and then examine whether CNFs exist in the system by Lagrange Multiplier (LM) test if unit root is rejected in the first step. The LM test has standard Chi-squared asymptotic distribution. The critical values of our unit root tests and small-sample properties of the F form of our LM test are studied by Monte Carlo simulations. We illustrate how to test and model CNFs using the monthly growth of consumption and income data of United States (1985:1 to 2011:11).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A system built in terms of autonomous agents may require even greater correctness assurance than one which is merely reacting to the immediate control of its users. Agents make substantial decisions for themselves, so thorough testing is an important consideration. However, autonomy also makes testing harder; by their nature, autonomous agents may react in different ways to the same inputs over time, because, for instance they have changeable goals and knowledge. For this reason, we argue that testing of autonomous agents requires a procedure that caters for a wide range of test case contexts, and that can search for the most demanding of these test cases, even when they are not apparent to the agents’ developers. In this paper, we address this problem, introducing and evaluating an approach to testing autonomous agents that uses evolutionary optimization to generate demanding test cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: As opposed to the cementation metal posts, the cementation of fiber posts has several details that can significantly influence the success of post retention. This study evaluated the effect of the relining procedure, the cement type, and the luted length of the post on fiber posts retention. Methods: One hundred eighty bovine incisors were selected to assess post retention; after endodontic treatment, the canals were flared with diamonds burs. Post holes were prepared in lengths of 5, 7.5, and 10 mm; the fiber posts were relined with composite resin and luted with RelyX ARC, RelyX Unicem, or RelyX Luting 2. All cements are manufactured by 3M ESPE (St. Paul, MN). Samples were subjected to a pull-out bond strength test in a universal testing machine; the results (N) were submitted to a three-way analysis of variance and the Tukey post hoc test (alpha = 0.05). Results: The improvement of post retention occurred with the increase of the post length luted into the root canal; the relining procedure improved the pull-out bond strength. RelyX Unicem and RelyX ARC showed similar values of retention, both showing higher values than RelyX Luting 2. Conclusion: Post length, the reining procedure, and the cement type are all important factors for improving the retention of fiber posts. (J Endod 2010;36:1543-1546)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ranzini (1988) proposed the Standard Penetration Test with torque measurement (SPT-T) and some geotechnical engineers in Brazil have been using it since 1991. This paper presents the state of the art on SPT-T testing, emphasizing what is already established as common knowledge in Brazilian engineering practice, besides a suggestion for test procedure, including equipment and practical aspects. In addition, the study of the shape of the torque versus rotation-degree angle curve obtained by an electric torquemeter used in several SPT-T tests carried out on six experimental research sites in the southeast region of Brazil is discussed here. Four different methods to predict pile capacity based on SPT-T test results are briefly presented and a comparison with load tests carried out on different types of piles, on those six experimental research sites, is presented.