SPT-T: test procedure and applications


Autoria(s): Peixoto, A. S. P.; de Carvalho, D.; Giacheti, H. L.; VianaDaFonsea, A.; Mayne, P. W.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/01/2004

Resumo

Ranzini (1988) proposed the Standard Penetration Test with torque measurement (SPT-T) and some geotechnical engineers in Brazil have been using it since 1991. This paper presents the state of the art on SPT-T testing, emphasizing what is already established as common knowledge in Brazilian engineering practice, besides a suggestion for test procedure, including equipment and practical aspects. In addition, the study of the shape of the torque versus rotation-degree angle curve obtained by an electric torquemeter used in several SPT-T tests carried out on six experimental research sites in the southeast region of Brazil is discussed here. Four different methods to predict pile capacity based on SPT-T test results are briefly presented and a comparison with load tests carried out on different types of piles, on those six experimental research sites, is presented.

Formato

359-366

Identificador

Geotechnical and Geophysical Site Characterization Vols 1 and 2. Rotterdam: Millpress Science Publishers, p. 359-366, 2004.

http://hdl.handle.net/11449/35144

WOS:000239478800026

Idioma(s)

eng

Publicador

Millpress Science Publishers

Relação

Geotechnical and Geophysical Site Characterization Vols 1 and 2

Direitos

closedAccess

Palavras-Chave #Standard Penetration Test #torque measurements #soil classification #lateral skin friction of piles
Tipo

info:eu-repo/semantics/conferencePaper