967 resultados para Spray nozzles
Resumo:
Turbulent free jets issuing from rectangular slots with various high aspect ratios (15-120) are characterized. The centerline mean and rms velocities are measured using hot-wire anemometry over a downstream distance of up to 160 slot heights at a slot-height-based Reynolds number of 10000. Experimental results suggest that a rectangular jet with sufficiently high aspect ratio (> 15) may be distinguished between three flow zones: an initial quasi-plane-jet zone, a transition zone, and a final quasi-axisymmetric-jet zone. In the quasi-plane-jet zone, the turbulent velocity field is statistically similar, but not identical, to those of a plane jet. (c) 2005 American Institute of Physics.
Resumo:
Objective To determine the efficacy of zeta-cypermethrin in controlling buffalo fly (Haematobia irritans exigua). Design Five field trials in northern and central Queensland. Procedure Zeta-cypermethrin pour-on at 2.5 mg/kg, spray at 62.5 ppm, deltamethrin pour-on and pour-on vehicle were applied to groups of 20 cattle. Buffalo fly counts were conducted three times before treatment and 3, 7, 14, 21, 28 and 35 days after treatment. Results In central Queensland where synthetic pyrethroid resistance in buffalo fly populations was rare, 2.5 mg/kg of zeta-cypermethrin pour-on gave good control of buffalo fly for 4 weeks and was better than a deltamethrin product. A zeta-cypermethrin spray used at 62.5 ppm gave 14 days control. In far-north Queensland where resistance to synthetic pyrethroids and heavy rain was common, the maximum period of efficacy of zeta-cypermethrin pour-on was reduced to 2 weeks. Conclusion In areas where there is low resistance to synthetic pyrethroids among buffalo flies, zeta-cypermethrin pour-on can be expected to give good control for 4 weeks.
Resumo:
The depletion of zeta-cypermethrin residues in bovine tissues and milk was studied. Beef cattle were treated three times at 3-week intervals with 1 ml 10 kg(-1) body weight of a 25 g litre(-1) or 50 g litre(-1) pour-on formulation (2.5 and 5.0 mg zeta-cypermethrin kg(-1) body weight) or 100 mg kg(-1) spray to simulate a likely worst-case treatment regime. Friesian and Jersey dairy cows were treated once with 2.5 mg zeta-cypermethrin kg(-1) in a pour-on formulation. Muscle, liver and kidney residue concentrations were generally less than the limit of detection (LOD = 0.01 mg kg(-1)). Residues in renal-fat and back-fat samples from animals treated with 2.5 mg kg(-1) all exceeded the limit of quantitation (LOQ = 0.05 mg kg(-1)), peaking at 10 days after treatment. Only two of five kidney fat samples were above the LOQ after 34 days, but none of the back-fat samples exceeded the LOQ at 28 days after treatment. Following spray treatments, fat residues were detectable in some animals but were below the LOQ at all sampling intervals. Zeta-cypermethrin was quantifiable (LOQ = 0.01 mg kg(-1)) in only one whole-milk sample from the Friesian cows (0.015 mg kg(-1), 2 days after treatment). In whole milk from Jersey cows, the mean concentration of zeta-cypermethrin peaked 1 day after treatment, at 0.015 mg kg(-1), and the highest individual sample concentration was 0.025 mg kg(-1) at 3 days after treatment. Residues in milk were not quantifiable beginning 4 days after treatment. The mean concentrations of zeta-cypermethrin in milk fat from Friesian and Jersey cows peaked two days after treatment at 0.197 mg kg(-1) and 0.377 mg kg(-1), respectively, and the highest individual sample concentrations were 2 days after treatment at 0.47 mg kg(-1) and 0.98 mg kg(-1), respectively. (C) 2001 Society of Chemical Industry.
Resumo:
The spray drying method was used to prepare luminescent microspheres. These microspheres were prepared by spraying an aqueous solution of dextrin and an europium(III) complex with subsequent drying in a hot medium. The spray dried powder was characterized by scanning electron microscopy (SEM) and photoluminescence spectroscopy (PL). Particle size distribution was estimated from SEM images. The ultrasonic spray drying technique was successfully applied to yield a microparticulated and red luminescent powder composed by the [Eu(dpa)(3)](3-) stop (dpa = dipicolinic acid) complex incorporated in dextrin microspheres.
Resumo:
Stickiness is a major reason that limits the spray drying of various sugar-rich food products. Higher hygroscopicity of amorphous powder, increase in solubility of sugars with temperature, and lower melting point and glass transition temperature, contribute to the stickiness problem. So far, the glass transition temperature has been widely accepted as a best indicator for stickiness. There are various manoeuvres that have been applied to spray dry such products. Some of them are the addition of drying aids, modification of drier design and use of mild drying temperature conditions. This review paper highlights the major research works that deal with the stickiness property of sugar-rich foods.
Resumo:
A semi-empirical linear equation has been developed to optimise the amount of maltodextrin additive (DE 6) required to successfully spray dry a sugar-rich product on the basis of its composition. Based on spray drying experiments, drying index values for individual sugars (sucrose, glucose, frutose) and citric acid were determined, and us;ng these index values an equation for model mixtures of these components was established. This equation has been tested with two sugar-rich natural products, pineapple juice and honey. The relationship was found to be valid for these products.
Resumo:
Surgeries performed with high-intensity laser devices may be improved with accurate protocols, including the air-water spray regulation. Thus, this study sought to investigate the healing process of wounds made on the dorsum of rat tongues using an Er,Cr:YSGG laser device with different air-water spray regulations. The incisions were made on the dorsum of Wistar rat tongues using an Er,Cr:YSGG laser with three different air-water spray regulations (100/0%, 50/50%, 11/7%). Scalpel incisions functioned as controls. The sacrifices occurred between 0 and 14 days after surgery. Morphological, histological, and immunohistochemical (fibronectin and type III collagen) analysis of the wounds were performed. The air-water spray regulation influenced wound healing and the inflammatory response, especially in the earlier stages. Incisions performed using the 100/0% air/water spray regulation had the worst results, expressing a greater amount of fibronectin and type III collagen. The 50/50% air/water spray regulation brought in a non-clear surgical field and poor laser interaction with the tissue. The 11/7% air/water spray regulation showed the best clinical results and less pronounced histological events. According to the results encountered, the air-water spray should be regulated to improve surgery.
Resumo:
This study investigates binder distribution in wet granulation and focuses on the nucleation zone, which is the area where the liquid binder and powder surface come into contact and form the initial nuclei. An equipment independent parameter, dimensionless spray flux Psi (a), is defined to characterise the most important process parameters in the nucleation process: solution flowrate, powder flux, and binder drop size. Ex-granulator experiments are used to study the relationship between dimensionless spray flux, process variables and the coverage of binder fluid on the powder surface. Lactose monohydrate powder on a variable speed riffler passed under a flat spray once only. Water and 7% HPC solution at two spray pressures were used as binders. Experiments with red dye and image analysis demonstrate that changes in dimensionless spray flux correlate with a measurable difference in powder surface coverage. Nucleation experiments show that spray flux controls the size and shape of the nuclei size distribution. At low Psi (a), the system operates in the drop controlled regime, where one drop forms one nucleus and the nuclei size distribution is narrow. At higher Psi (a), the powder surface cakes creating a broader size distribution. For controlled nucleation with the narrowest possible size distribution, it is recommended that the dimensionless spray flux be less than 0.1 to be in the drop-controlled regime. (C) 2001 Elsevier Science S.A. All rights reserved.