877 resultados para Spinal flexibility
Resumo:
The structure and conformation of a second crystalline modification of 19-nortestosterone has been determined by X-ray methods. M r = 274, monoclinic P2 l, a=9.755(2), b= 11.467(3), c= 14.196(3)/L fl=101.07(2) ° , V=1558.4 (8) A 3, Z=4, Ox= I. 168 g cm -3, Mo Ka, 2 = 0.7107 ,/k, ~ = 0.80 cm -l, F(000) = 600, T= 300 K. R = 0.060 for 2158 observed reflections. The two molecules in the asymmetric unit show significant differences in the A-ring conformation from that of the previously reported form of the title compound [Precigoux, Busetta, Courseille & Hospital (1975). Acta Cryst. B31, 1527-1532]. The l a,2fl-half-chair conformation of the A ring increases its conformational freedom compared with testosterone.
Resumo:
It is shown that left-handed duplexes are possible for A, B, and D forms of DNA. These duplexes are stereochemically satisfactory and are consistent with the observed x-ray intensity data. On scrutiny the refined right-handed models of B and D DNA by Arnott and coworkers are found to be stereochemically unacceptable. It was possible to formulate a stereochemical guideline for molecular model building based on theory and analysis of single-crystal structure data of dinucleoside monophosphate and higher oligomers. This led to both right- and left-handed DNA duplexes. The right-handed B and D DNA duplexes so obtained are stereochemically superior to earlier models and agree well with the observed x-ray intensity data. The observation that DNA can exist in either handedness for all the polymorphous forms of DNA at once explained A in equilibrium B and B in equilibrium D transitions. Hence it is confirmed that polymorphism of DNA is a reflection on the conformational flexibility inherent in DNA, the same cause that ultimately allows DNA in either handedness. The possibility of various types of right- and left-handed duplexes generated by using dinucleoside monophosphate and trinucleoside diphosphate as repeating units resulted in a variety of models, called RL models. All these models have alternating right and left helical segments and inverted stacking at the bend region as suggested by us earlier. It turns out that the B-Z DNA model of Wang et al. is only an example of RL models.
Resumo:
Background Segmental biomechanics of the scoliotic spine are important since the overall spinal deformity is comprised of the cumulative coronal and axial rotations of individual joints. This study investigates the coronal plane segmental biomechanics for adolescent idiopathic scoliosis patients in response to physiologically relevant axial compression. Methods Individual spinal joint compliance in the coronal plane was measured for a series of 15 idiopathic scoliosis patients using axially loaded magnetic resonance imaging. Each patient was first imaged in the supine position with no axial load, and then again following application of an axial compressive load. Coronal plane disc wedge angles in the unloaded and loaded configurations were measured. Joint moments exerted by the axial compressive load were used to derive estimates of individual joint compliance. Findings The mean standing major Cobb angle for this patient series was 46°. Mean intra-observer measurement error for endplate inclination was 1.6°. Following loading, initially highly wedged discs demonstrated a smaller change in wedge angle, than less wedged discs for certain spinal levels (+ 2,+1,− 2 relative to the apex, (p < 0.05)). Highly wedged discs were observed near the apex of the curve, which corresponded to lower joint compliance in the apical region. Interpretation While individual patients exhibit substantial variability in disc wedge angles and joint compliance, overall there is a pattern of increased disc wedging near the curve apex, and reduced joint compliance in this region. Approaches such as this can provide valuable biomechanical data on in vivo spinal biomechanics of the scoliotic spine, for analysis of deformity progression and surgical planning.
Resumo:
The intervertebral disc withstands large compressive loads (up to nine times bodyweight in humans) while providing flexibility to the spinal column. At a microstructural level, the outer sheath of the disc (the annulus fibrosus) comprises 12–20 annular layers of alternately crisscrossed collagen fibres embedded in a soft ground matrix. The centre of the disc (the nucleus pulposus) consists of a hydrated gel rich in proteoglycans. The disc is the largest avascular structure in the body and is of much interest biomechanically due to the high societal burden of disc degeneration and back pain. Although the disc has been well characterized at the whole joint scale, it is not clear how the disc tissue microstructure confers its overall mechanical properties. In particular, there have been conflicting reports regarding the level of attachment between adjacent lamellae in the annulus, and the importance of these interfaces to the overall integrity of the disc is unknown. We used a polarized light micrograph of the bovine tail disc in transverse cross-section to develop an image-based finite element model incorporating sliding and separation between layers of the annulus, and subjected the model to axial compressive loading. Validation experiments were also performed on four bovine caudal discs. Interlamellar shear resistance had a strong effect on disc compressive stiffness, with a 40% drop in stiffness when the interface shear resistance was changed from fully bonded to freely sliding. By contrast, interlamellar cohesion had no appreciable effect on overall disc mechanics. We conclude that shear resistance between lamellae confers disc mechanical resistance to compression, and degradation of the interlamellar interface structure may be a precursor to macroscopic disc degeneration.
Resumo:
This thesis studied a new minimally invasive implant for scoliosis correction that aims to correct the deformity without fusing the spine, thereby allowing movement and growth in the spine following surgery. The effect of two different vertebral body implant (staple) designs on the stiffness of the spine, using calf spines as an in vitro model, was studied. The results showed that the implants decreased spinal stiffness, with associated potential damage to the growth plates due to the staple tips. There were no significant differences in stiffness between the two staple designs tested.
Resumo:
Possible conformations of penicillin G; d and l isomers of ampicillin; α-amino-α-methyl-benzyl penicillins and 3- pyridyl methyl penicillin have been studied by an energy minimization procedure using empirical potential functions. The preferred conformations of these antibiotics have been correlated with their biological activity. The conformational requirement of the antibiotic to be active against Gram-positive and Gram-negative (β-lactamase-negative) bacterial strains seems to be the same. The reduced activity of penicillin G against Gram-negative bacteria has been attributed to its lower ability to permeate the outer membrane. The flexibility of the sidechains of these antibiotics is also shown to be important for the desired biological activity.
Resumo:
Crystal structures of six isopropylidene nucleoside derivatives are described. The results show that, under external cyclic constraints, the ribose assumes a variety of unusual conformations. In those compounds which possess a base-to-sugar cyclization through the C(4′) atom, the furanose pucker is predominantly C(4′)-endo, O(4′)-exo. The possible relevance of the sulphur geometry in two of the compounds to certain structural aspects of the action of the enzyme thymidylate synthetase is also pointed out.
Resumo:
A compilation of crystal structure data on deoxyribo- and ribonucleosides and their higher derivatives is presented. The aim of this paper is to highlight the flexibility of deoxyribose and ribose rings. So far, the conformational parameters of nucleic acids constituents of ribose and deoxyribose have not been analysed separately. This paper aims to correlate the conformational parameters with the nature and puckering of the sugar. Deoxyribose puckering occurs in the C2′ endo region while ribose puckering is observed both in the C3′ endo and C2′ endo regions. A few endocyclic and exocyclic bond angles depend on the puckering and the nature of the sugar. The majority of structures have an anti conformation about the glycosyl bond. There appears to be a puckering dependence on the torsion angle about the C4′---C5′ bonds. Such stereochemical information is useful in model building studies of polynucleotides and nucleic acids.
Resumo:
Left handed duplexes are shown to be in agreement with the X-ray intensity data of A-, B- and D-forms of DNA. The structures are stereochemically satisfactory because they were obtained following a stereochemical guideline derived from theory and single crystal structure data of nucleic acid components. The same stereochemical guideline also led to right handed duplexes for B- and D-forms of DNA which have stereochemically preferred conformation and hence are superior to those given by Arnott and coworkers.
Resumo:
Background: Forward head posture (FHP) is a commonly reported deviation from a neutral neck posture, usually implying a protracted head position in the sagittal plane. Habitual FHP has been associated with a higher incidence of painful neck disorders, changes in joint mobility and muscle behaviour within the cervicothoracic regions. One factor that has received attention in the literature with regards to FHP is flexibility of the neck. A number of previous studies have previously investigated the relationship between neck flexibility and neck posture under different conditions, but at present this relationship is unclear.
Resumo:
The current research proposed a conceptual design framework for airports to obtain flexible departure layouts based on passenger activity analysis obtained from Business Process Models (BPM). BPMs available for airport terminals were used as a design tool in the current research to uncover the relationships existing between spatial layout and corresponding passenger activities. An algorithm has been developed that demonstrates the applicability of the proposed design framework by obtaining relative spatial layouts based on passenger activity analysis. The generated relative spatial layout assists architects in achieving suitable alternative layouts to meet the changing needs of an airport terminal.
Resumo:
Flexible working arrangements have attracted growing attention in workplaces across Australia and in many other countries in recent years. This contribution utilises the results of two large Australian employee surveys to analyse who asks for flexibility, why, and with what effects on work-life interference. This analysis is set in the context of Australia’s ‘Right to Request’ (RTR) provisions which, at the time of the study, gave parents of preschool children and those with a disabled child aged up to 18 the RTR flexibility. The analysis also draws on a set of qualitative interviews of those we term ‘discontented non-requesters’ (that is, those who are not content with current arrangements but who do not ask for flexibility) to probe beneath the survey results to consider explanations about why some people do not ask for flexibility despite desiring different working arrangements. We conclude with the implications for policy and regulation.
Resumo:
Continuous epidural analgesia (CEA) and continuous spinal postoperative analgesia (CSPA) provided by a mixture of local anaesthetic and opioid are widely used for postoperative pain relief. E.g., with the introduction of so-called microcatheters, CSPA found its way particularly in orthopaedic surgery. These techniques, however, may be associated with dose-dependent side-effects as hypotension, weakness in the legs, and nausea and vomiting. At times, they may fail to offer sufficient analgesia, e.g., because of a misplaced catheter. The correct position of an epidural catheter might be confirmed by the supposedly easy and reliable epidural stimulation test (EST). The aims of this thesis were to determine a) whether the efficacy, tolerability, and reliability of CEA might be improved by adding the α2-adrenergic agonists adrenaline and clonidine to CEA, and by the repeated use of EST during CEA; and, b) the feasibility of CSPA given through a microcatheter after vascular surgery. Studies I IV were double-blinded, randomized, and controlled trials; Study V was of a diagnostic, prospective nature. Patients underwent arterial bypass surgery of the legs (I, n=50; IV, n=46), total knee arthroplasty (II, n=70; III, n=72), and abdominal surgery or thoracotomy (V, n=30). Postoperative lumbar CEA consisted of regular mixtures of ropivacaine and fentanyl either without or with adrenaline (2 µg/ml (I) and 4 µg/ml (II)) and clonidine (2 µg/ml (III)). CSPA (IV) was given through a microcatheter (28G) and contained either ropivacaine (max. 2 mg/h) or a mixture of ropivacaine (max. 1 mg/h) and morphine (max. 8 µg/h). Epidural catheter tip position (V) was evaluated both by EST at the moment of catheter placement and several times during CEA, and by epidurography as reference diagnostic test. CEA and CSPA were administered for 24 or 48 h. Study parameters included pain scores assessed with a visual analogue scale, requirements of rescue pain medication, vital signs, and side-effects. Adrenaline (I and II) had no beneficial influence as regards the efficacy or tolerability of CEA. The total amounts of epidurally-infused drugs were even increased in the adrenaline group in Study II (p=0.02, RM ANOVA). Clonidine (III) augmented pain relief with lowered amounts of epidurally infused drugs (p=0.01, RM ANOVA) and reduced need for rescue oxycodone given i.m. (p=0.027, MW-U; median difference 3 mg (95% CI 0 7 mg)). Clonidine did not contribute to sedation and its influence on haemodynamics was minimal. CSPA (IV) provided satisfactory pain relief with only limited blockade of the legs (no inter-group differences). EST (V) was often related to technical problems and difficulties of interpretation, e.g., it failed to identify the four patients whose catheters were outside the spinal canal already at the time of catheter placement. As adjuvants to lumbar CEA, clonidine only slightly improved pain relief, while adrenaline did not provide any benefit. The role of EST applied at the time of epidural catheter placement or repeatedly during CEA remains open. The microcatheter CSPA technique appeared effective and reliable, but needs to be compared to routine CEA after peripheral arterial bypass surgery.