967 resultados para Sensor array processing
Resumo:
Photovoltaic (PV) stations have been widely built in the world to utilize solar energy directly. In order to reduce the capital and operational costs, early fault diagnosis is playing an increasingly important role by enabling the long effective operation of PV arrays. This paper analyzes the terminal characteristics of faulty PV strings and arrays, and it develops a PV array fault diagnosis technique. The terminal current-voltage curve of a faulty PV array is divided into two sections, i.e., high-voltage and low-voltage fault diagnosis sections. The corresponding working points of healthy string modules and of healthy and faulty modules in an unhealthy string are then analyzed for each section. By probing into different working points, a faulty PV module can be located. The fault information is of critical importance for the maximum power point tracking and the array dynamical reconfiguration. Furthermore, the string current sensors can be eliminated, and the number of voltage sensors can be reduced by optimizing voltage sensor locations. Typical fault scenarios including monostring, multistring, and a partial shadow for a 1.6-kW 3 $times$ 3 PV array are presented and experimentally tested to confirm the effectiveness of the proposed fault diagnosis method.
Resumo:
PURPOSE:
To evaluate the combination of a pressure-indicating sensor film with hydrogel-forming microneedle arrays, as a method of feedback to confirm MN insertion in vivo.
METHODS:
Pilot in vitro insertion studies were conducted using a Texture Analyser to insert MN arrays, coupled with a pressure-indicating sensor film, at varying forces into excised neonatal porcine skin. In vivo studies involved twenty human volunteers, who self-applied two hydrogel-forming MN arrays, one with a pressure-indicating sensor film incorporated and one without. Optical coherence tomography was employed to measure the resulting penetration depth and colorimetric analysis to investigate the associated colour change of the pressure-indicating sensor film.
RESULTS:
Microneedle insertion was achieved in vitro at three different forces, demonstrating the colour change of the pressure-indicating sensor film upon application of increasing pressure. When self-applied in vivo, there was no significant difference in the microneedle penetration depth resulting from each type of array, with a mean depth of 237 μm recorded. When the pressure-indicating sensor film was present, a colour change occurred upon each application, providing evidence of insertion.
CONCLUSIONS:
For the first time, this study shows how the incorporation of a simple, low-cost pressure-indicating sensor film can indicate microneedle insertion in vitro and in vivo, providing visual feedback to assure the user of correct application. Such a strategy may enhance usability of a microneedle device and, hence, assist in the future translation of the technology to widespread clinical use.
Resumo:
This thesis presents the achievements and scientific work conducted using a previously designed and fabricated 64 x 64-pixel ion camera with the use of a 0.35 μm CMOS technology. We used an array of Ion Sensitive Field Effect Transistors (ISFETs) to monitor and measure chemical and biochemical reactions in real time. The area of our observation was a 4.2 x 4.3 mm silicon chip while the actual ISFET array covered an area of 715.8 x 715.8 μm consisting of 4096 ISFET pixels in total with a 1 μm separation space among them. The ion sensitive layer, the locus where all reactions took place was a silicon nitride layer, the final top layer of the austriamicrosystems 0.35 μm CMOS technology used. Our final measurements presented an average sensitivity of 30 mV/pH. With the addition of extra layers we were able to monitor a 65 mV voltage difference during our experiments with glucose and hexokinase, whereas a difference of 85 mV was detected for a similar glucose reaction mentioned in literature, and a 55 mV voltage difference while performing photosynthesis experiments with a biofilm made from cyanobacteria, whereas a voltage difference of 33.7 mV was detected as presented in literature for a similar cyanobacterial species using voltamemtric methods for detection. To monitor our experiments PXIe-6358 measurement cards were used and measurements were controlled by LabVIEW software. The chip was packaged and encapsulated using a PGA-100 chip carrier and a two-component commercial epoxy. Printed circuit board (PCB) has also been previously designed to provide interface between the chip and the measurement cards.
Resumo:
A medição precisa da força é necessária para muitas aplicações, nomeadamente, para a determinação da resistência mecânica dos materiais, controlo de qualidade durante a produção, pesagem e segurança de pessoas. Dada a grande necessidade de medição de forças, têm-se desenvolvido, ao longo do tempo, várias técnicas e instrumentos para esse fim. Entre os vários instrumentos utilizados, destacam-se os sensores de força, também designadas por células de carga, pela sua simplicidade, precisão e versatilidade. O exemplo mais comum é baseado em extensómetros elétricos do tipo resistivo, que aliados a uma estrutura formam uma célula de carga. Este tipo de sensores possui sensibilidades baixas e em repouso, presença de offset diferente de zero, o que torna complexo o seu condicionamento de sinal. Este trabalho apresenta uma solução para o condicionamento e aquisição de dados para células de carga que, tanto quanto foi investigado, é inovador. Este dispositivo permite efetuar o condicionamento de sinal, digitalização e comunicação numa estrutura atómica. A ideia vai de encontro ao paradigma dos sensores inteligentes onde um único dispositivo eletrónico, associado a uma célula de carga, executa um conjunto de operações de processamento de sinal e transmissão de dados. Em particular permite a criação de uma rede ad-hoc utilizando o protocolo de comunicação IIC. O sistema é destinado a ser introduzido numa plataforma de carga, desenvolvida na Escola Superior de Tecnologia e Gestão de Bragança, local destinado à sua implementação. Devido à sua estratégia de conceção para a leitura de forças em três eixos, contém quatro células de carga, com duas saídas cada, totalizando oito saídas. O hardware para condicionamento de sinal já existente é analógico, e necessita de uma placa de dimensões consideráveis por cada saída. Do ponto de vista funcional, apresenta vários problemas, nomeadamente o ajuste de ganho e offset ser feito manualmente, tornando-se essencial um circuito com melhor desempenho no que respeita a lidar com um array de sensores deste tipo.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
Real-time viscosity measurement remains a necessity for highly automated industry. To resolve this problem, many studies have been carried out using an ultrasonic shear wave reflectance method. This method is based on the determination of the complex reflection coefficient`s magnitude and phase at the solid-liquid interface. Although magnitude is a stable quantity and its measurement is relatively simple and precise, phase measurement is a difficult task because of strong temperature dependence. A simplified method that uses only the magnitude of the reflection coefficient and that is valid under the Newtonian regimen has been proposed by some authors, but the obtained viscosity values do not match conventional viscometry measurements. In this work, a mode conversion measurement cell was used to measure glycerin viscosity as a function of temperature (15 to 25 degrees C) and corn syrup-water mixtures as a function of concentration (70 to 100 wt% of corn syrup). Tests were carried out at 1 MHz. A novel signal processing technique that calculates the reflection coefficient magnitude in a frequency band, instead of a single frequency, was studied. The effects of the bandwidth on magnitude and viscosity were analyzed and the results were compared with the values predicted by the Newtonian liquid model. The frequency band technique improved the magnitude results. The obtained viscosity values came close to those measured by the rotational viscometer with percentage errors up to 14%, whereas errors up to 96% were found for the single frequency method.
Resumo:
We present a novel array RLS algorithm with forgetting factor that circumvents the problem of fading regularization, inherent to the standard exponentially-weighted RLS, by allowing for time-varying regularization matrices with generic structure. Simulations in finite precision show the algorithm`s superiority as compared to alternative algorithms in the context of adaptive beamforming.
Resumo:
The compound eyes of mantis shrimps, a group of tropical marine crustaceans, incorporate principles of serial and parallel processing of visual information that may be applicable to artificial imaging systems. Their eyes include numerous specializations for analysis of the spectral and polarizational properties of light, and include more photoreceptor classes for analysis of ultraviolet light, color, and polarization than occur in any other known visual system. This is possible because receptors in different regions of the eye are anatomically diverse and incorporate unusual structural features, such as spectral filters, not seen in other compound eyes. Unlike eyes of most other animals, eyes of mantis shrimps must move to acquire some types of visual information and to integrate color and polarization with spatial vision. Information leaving the retina appears to be processed into numerous parallel data streams leading into the central nervous system, greatly reducing the analytical requirements at higher levels. Many of these unusual features of mantis shrimp vision may inspire new sensor designs for machine vision
Resumo:
This paper reports on the design and development of a dividing/phasing network for a compact switched-beam array antenna for Land-vehicle mobile satellite communications, The device is formed by a switched radial divider/combiner and 1-bit phase shifters and generates a sufficient number of beams for the proper satellite tracking.
Resumo:
The exponential increase of home-bound persons who live alone and are in need of continuous monitoring requires new solutions to current problems. Most of these cases present illnesses such as motor or psychological disabilities that deprive of a normal living. Common events such as forgetfulness or falls are quite common and have to be prevented or dealt with. This paper introduces a platform to guide and assist these persons (mostly elderly people) by providing multisensory monitoring and intelligent assistance. The platform operates at three levels. The lower level, denominated ‘‘Data acquisition and processing’’performs the usual tasks of a monitoring system, collecting and processing data from the sensors for the purpose of detecting and tracking humans. The aim is to identify their activities in an intermediate level called ‘‘activity detection’’. The upper level, ‘‘Scheduling and decision-making’’, consists of a scheduler which provides warnings, schedules events in an intelligent manner and serves as an interface to the rest of the platform. The idea is to use mobile and static sensors performing constant monitoring of the user and his/her environment, providing a safe environment and an immediate response to severe problems. A case study on elderly fall detection in a nursery home bedroom demonstrates the usefulness of the proposal.
Resumo:
Esta tese tem como principal objectivo a investigação teórica e experimental do desempenho de um sensor polarimétrico baseado num cristal líquido para medição da concentração de glicose. Recentemente uma série de sensores polarimétricos baseados em cristais líquidos foram propostos na literatura e receberam considerável interesse devido as suas características únicas. De facto, em comparação com outros moduladores electro-ópticos, o cristal líquido funciona com tensões mais baixas, tem baixo consumo de energia e maior ângulo de rotação. Além disso, este tipo de polarímetro pode ter pequenas dimensões que é uma característica interessante para dispositivos portáteis e compactos. Existem por outro lado algumas desvantagens, nomeadamente o facto do desempenho do polarímetro ser fortemente dependente do tipo de cristal líquido e da tensão a ele aplicada o que coloca desafios na escolha dos parâmetros óptimos de operação. Esta tese descreve o desenvolvimento do sensor polarimétrico, incluindo a integração dos componentes de óptica e electrónica, os algoritmos de processamento de sinal e um interface gráfico que facilita a programação de diversos parâmetros de operação e a calibração do sensor. Após a optimização dos parâmetros de operação verificou-se que o dispositivo mede a concentração da glicose em amostras com uma concentração de 8 mg/ml, com uma percentagem de erro inferior a 6% e um desvio padrão de 0,008o. Os resultados foram obtidos para uma amostra com percurso óptico de apenas 1 cm.
Resumo:
A visible/near-infrared optical sensor based on an ITO/SiOx/n-Si structure with internal gain is presented. This surface-barrier structure was fabricated by a low-temperature processing technique. The interface properties and carder transport were investigated from dark current-voltage and capacitance-voltage characteristics. Examination of the multiplication properties was performed under different light excitation and reverse bias conditions. The spectral and pulse response characteristics are analysed. The current amplification mechanism is interpreted by the control of electron current by the space charge of photogenerated holes near the SiOx/Si interface. The optical sensor output characteristics and some possible device applications are presented.
Resumo:
A presente dissertação descreve o desenvolvimento e a caracterização de sensores ópticos com base em membranas de poli(cloreto de vinilo), PVC, para determinação de Norfloxacina em amostras do sector da aquacultura. Estes sensores basearam-se na reacção colorimétrica entre um metal imobilizado em PVC e a Norfloxacina. O metal foi escolhido com base em ensaios prévios de reacção colorimétrica entre a Norfloxacina e várias espécies metálicas, nomeadamente, Fe(III), Al(III), Pb(II), Aluminon, Mo(II), Mn(II), Ni(II), Cu(II), Co(II), Sn(II) e V(V). A reacção mais intensa foi obtida com o Fe(III). Neste sentido, numa primeira fase foram desenvolvidos sensores baseados em Fe(III). O efeito de alguns parâmetros experimentais na resposta desses sensores foi avaliado de modo univariado. Incluem-se aqui o efeito do pH, avaliado entre 2,00 e 6,00, e o da concentração de Fe(III), variada entre cerca de 1,00x10-5 M e 2,00x10-4 M. Os melhores valores foram obtidos a pH 3, para o qual se verificou um comportamento linear entre cerca de 1,00x10-5 M e 1,70x10-4 M de Fe(III). Utilizando as condições seleccionadas anteriormente, procedeu-se à caracterização do complexo sob ponto de vista químico. Os valores obtidos apontaram para a necessidade de um excesso de Fe(III) de, pelo menos, 10 vezes, no sentido de garantir a máxima extensão de complexação. O complexo referido apresentou, nestas condições, um comportamento linear ao longo do intervalo de concentrações de cerca de 7,00x10-5 M a 7,00x10-4 M em NOR. O complexo formado foi estável ao longo de 90 minutos. As condições óptimas para análise desse complexo numa superfície sólida foram obtidas após avaliação do efeito da quantidade de Fe(III) e do tipo e quantidade de solvente mediador (o-nitrofenil octil éter, di-n-octilftalato, dibutilftalato, bis(etilhexil)sebacato, bis(etilhexil)ftalato). O bis(etilhexil)sebacato foi o solvente mediador escolhido e a relação de quantidade entre o PVC e o solvente mediador foi igual a 1:2. O procedimento de preparação do sensor sólido e subsequente optimização foi aplicado a outras espécies metálicas, para além do Fe(III), tais como, Cu(II), Mn(II) e aluminon. A conjugação de todos estes metais permitiu desenvolver um array de sensores para despistagem de Norfloxacina em águas de aquacultura. Algumas membranas sensoras foram aplicadas com sucesso no controlo de Norfloxacina em amostras de águas ambientais dopadas. Os resultados obtidos com membranas de Fe(III) e Cu(II) foram exactos, tendo-se registado valores de concentração próximos dos reais. O método proposto permitiu, por isso, a despistagem rápida e eficaz da presença de um antibiótico em águas ambientais, permitindo ainda o seu doseamento a um baixo custo. Numa perspectiva de rotina, e tendo em vista a despistagem deste antibiótico, este método revelou-se mais rápido e mais barato do que os demais métodos descritos na literatura para este efeito.
Resumo:
Relatório do Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
Trabalho de Projeto para obtenção do grau de Mestre em Engenharia de Eletrónica e Telecomunicações