1000 resultados para Schaeffer function


Relevância:

20.00% 20.00%

Publicador:

Resumo:

New substation technology, such as non-conventional instrument transformers,and a need to reduce design and construction costs, are driving the adoption of Ethernet based digital process bus networks for high voltage substations. Protection and control applications can share a process bus, making more efficient use of the network infrastructure. This paper classifies and defines performance requirements for the protocols used in a process bus on the basis of application. These include GOOSE, SNMP and IEC 61850-9-2 sampled values. A method, based on the Multiple Spanning Tree Protocol (MSTP) and virtual local area networks, is presented that separates management and monitoring traffic from the rest of the process bus. A quantitative investigation of the interaction between various protocols used in a process bus is described. These tests also validate the effectiveness of the MSTP based traffic segregation method. While this paper focusses on a substation automation network, the results are applicable to other real-time industrial networks that implement multiple protocols. High volume sampled value data and time-critical circuit breaker tripping commands do not interact on a full duplex switched Ethernet network, even under very high network load conditions. This enables an efficient digital network to replace a large number of conventional analog connections between control rooms and high voltage switchyards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This chapter presents a pilot study examining the interactive contributions of executive function development/impairment and psychosocial stress to young adults’ (17-30 years old) driving behaviour in a simulator city scenario.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we investigate the distribution of the product of Rayleigh distributed random variables. Considering the Mellin-Barnes inversion formula and using the saddle point approach we obtain an upper bound for the product distribution. The accuracy of this tail-approximation increases as the number of random variables in the product increase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold water immersion (CWI) is a popular recovery modality, but actual physiological responses to CWI after exercise in the heat have not been well documented. The purpose of this study was to examine effects of 20-min CWI (14 degrees C) on neuromuscular function, rectal (T(re)) and skin temperature (T(sk)), and femoral venous diameter after exercise in the heat. Ten well-trained male cyclists completed two bouts of exercise consisting of 90-min cycling at a constant power output (216+/-12W) followed by a 16.1km time trial (TT) in the heat (32 degrees C). Twenty-five minutes post-TT, participants were assigned to either CWI or control (CON) recovery conditions in a counterbalanced order. T(re) and T(sk) were recorded continuously, and maximal voluntary isometric contraction torque of the knee extensors (MVIC), MVIC with superimposed electrical stimulation (SMVIC), and femoral venous diameters were measured prior to exercise, 0, 45, and 90min post-TT. T(re) was significantly lower in CWI beginning 50min post-TT compared with CON, and T(sk) was significantly lower in CWI beginning 25min post-TT compared with CON. Decreases in MVIC, and SMVIC torque after the TT were significantly greater for CWI compared with CON; differences persisted 90min post-TT. Femoral vein diameter was approximately 9% smaller for CWI compared with CON at 45min post-TT. These results suggest that CWI decreases T(re), but has a negative effect on neuromuscular function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smartphones become very critical part of our lives as they offer advanced capabilities with PC-like functionalities. They are getting widely deployed while not only being used for classical voice-centric communication. New smartphone malwares keep emerging where most of them still target Symbian OS. In the case of Symbian OS, application signing seemed to be an appropriate measure for slowing down malware appearance. Unfortunately, latest examples showed that signing can be bypassed resulting in new malware outbreak. In this paper, we present a novel approach to static malware detection in resource-limited mobile environments. This approach can be used to extend currently used third-party application signing mechanisms for increasing malware detection capabilities. In our work, we extract function calls from binaries in order to apply our clustering mechanism, called centroid. This method is capable of detecting unknown malwares. Our results are promising where the employed mechanism might find application at distribution channels, like online application stores. Additionally, it seems suitable for directly being used on smartphones for (pre-)checking installed applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose In this study we examine neuroretinal function in five amblyopes, who had been shown in previous functional MRI (fMRI) studies to have compromised function of the lateral geniculate nucleus (LGN), to determine if the fMRI deficit in amblyopia may have its origin at the retinal level. Methods We used slow flash multifocal ERG (mfERG) and compared averaged five ring responses of the amblyopic and fellow eyes across a 35 deg field. Central responses were also assessed over a field which was about 6.3 deg in diameter. We measured central retinal thickness using optical coherence tomography. Central fields were measured using the MP1-Microperimeter which also assesses ocular fixation during perimetry. MfERG data were compared with fMRI results from a previous study. Results Amblyopic eyes had reduced response density amplitudes (first major negative to first positive (N1-P1) responses) for the central and paracentral retina (up to 18 deg diameter) but not for the mid-periphery (from 18 to 35 deg). Retinal thickness was within normal limits for all eyes, and not different between amblyopic and fellow eyes. Fixation was maintained within the central 4° more than 80% of the time by four of the five participants; fixation assessed using bivariate contour ellipse areas (BCEA) gave rankings similar to those of the MP-1 system. There was no significant relationship between BCEA and mfERG response for either amblyopic or fellow eye. There was no significant relationship between the central mfERG eye response difference and the selective blood oxygen level dependent (BOLD) LGN eye response difference previously seen in these participants. Conclusions Retinal responses in amblyopes can be reduced within the central field without an obvious anatomical basis. Additionally, this retinal deficit may not be the reason why the LGN BOLD (blood oxygen level dependent) responses are reduced for amblyopic eye stimulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether neuroretinal function differs in healthy persons with and without common risk gene variants for age- related macular degeneration (AMD) and no ophthalmoscopic signs of AMD, and to compare those findings in persons with manifest early AMD. Methods and Participants: Neuroretinal function was assessed with the multifocal electroretinogram (mfERG) (VERIS, Redwood City, CA,) in 32 participants (22 healthy persons with no clinical signs of AMD and 10 early AMD patients). The 22 healthy participants with no AMD were risk genotypes for either the CFH (rs380390) and/or ARMS2 (rs10490920). We used a slow flash mfERG paradigm (3 inserted frames) and a 103 hexagon stimulus array. Recordings were made with DTL electrodes; fixation and eye movements were monitored online. Trough N1 to peak P1 (N1P1) response densities and P1-implicit times (IT) were analysed in 5 concentric rings. Results: N1P1 response densities (mean ± SD) for concentric rings 1-3 were on average significantly higher in at-risk genotypes (ring 1: 17.97 nV/deg2 ± 1.9, ring 2: 11.7 nV/deg2 ±1.3, ring 3: 8.7 nV/deg2 ± 0.7) compared to those without risk (ring 1: 13.7 nV/deg2 ± 1.9, ring 2: 9.2 nV/deg2 ±0.8, ring 3: 7.3 nV/deg2 ± 1.1) and compared to persons with early AMD (ring 1: 15.3 nV/deg2 ± 4.8, ring 2: 9.1 nV/deg2 ±2.3, ring 3 nV/deg2: 7.3± 1.3) (p<0.5). The group implicit times, P1-ITs for ring 1 were on average delayed in the early AMD patients (36.4 ms ± 1.0) compared to healthy participants with (35.1 ms ± 1.1) or without risk genotypes (34.8 ms ±1.3), although these differences were not significant. Conclusion: Neuroretinal function in persons with normal fundi can be differentiated into subgroups based on their genetics. Increased neuroretinal activity in persons who carry AMD risk genotypes may be due to genetically determined subclinical inflammatory and/or histological changes in the retina. Assessment of neuroretinal function in healthy persons genetically susceptible to AMD may be a useful early biomarker before there is clinical manifestation of AMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We applied small-angle neutron scattering (SANS) and ultra small-angle neutron scattering (USANS) to monitor evolution of the CO2 adsorption in porous silica as a function of CO2 pressure and temperature in pores of different sizes. The range of pressures (0 < P < 345 bar) and temperatures (T=18 OC, 35 OC and 60 OC) corresponded to subcritical, near critical and supercritical conditions of bulk fluid. We observed that the adsorption behavior of CO2 is fundamentally different in large and small pores with the sizes D > 100 Å and D < 30 Å, respectively. Scattering data from large pores indicate formation of a dense adsorbed film of CO2 on pore walls with the liquid-like density (ρCO2)ads≈0.8 g/cm3. The adsorbed film coexists with unadsorbed fluid in the inner pore volume. The density of unadsorbed fluid in large pores is temperature and pressure dependent: it is initially lower than (ρCO2)ads and gradually approaches it with pressure. In small pores compressed CO2 gas completely fills the pore volume. At the lowest pressures of the order of 10 bar and T=18 OC, the fluid density in smallest pores available in the matrix with D ~ 10 Å exceeds bulk fluid density by a factor of ~ 8. As pressure increases, progressively larger pores become filled with the condensed CO2. Fluid densification is only observed in pores with sizes less than ~ 25 – 30 Å. As the density of the invading fluid reaches (ρCO2)bulk~ 0.8 g/cm3, pores of all sizes become uniformly filled with CO2 and the confinement effects disappear. At higher densities the fluid in small pores appears to follow the equation of state of bulk CO2 although there is an indication that the fluid density in the inner volume of large pores may exceed the density of the adsorbed layer. The equivalent internal pressure (Pint) in the smallest pores exceeds the external pressure (Pext) by a factor of ~ 5 for both sub- and supercritical CO2. Pint gradually approaches Pext as D → 25 – 30 Å and is independent of temperature in the studied range of 18 OC ≤ T ≤ 60 OC. The obtained results demonstrate certain similarity as well as differences between adsorption of subcritical and supercritical CO2 in disordered porous silica. High pressure small angle scattering experiments open new opportunities for in situ studies of the fluid adsorption in porous media of interest to CO2 sequestration, energy storage, and heterogeneous catalysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper examines the impact of the introduction of no-fault divorce legislation in Australia. The approach used is rather novel, a hazard model of the divorce rate is estimated with the role of legislation captured via a time-varying covariate. The paper concludes that contrary to US empirical evidence, no-fault divorce legislation appears to have had a positive impact upon the divorce rate in Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the growing importance of IS for organizations and the continuous stream of new IT developments, the IS function in organizations becomes more critical but is also more challenged. For example, how should the IS function deal with the consumerization of IT or what is the added value of the IS function when it comes to SaaS and the Cloud? In this paper we argue that IS research is in need of a dynamic perspective on the IS function. The IS function has to become more focused on building and adapting IS capabilities in a changing environment. We discuss that there has been an overreliance on the Resource Based View so far for understanding the IS function and capabilities and introduce Dynamic Capabilities Theory as an additional theoretical perspective, which has only been limitedly addressed in IS literature yet. We present a first conceptualization of the dynamic IS function and discuss IS capabilities frameworks and individual IS capabilities from a dynamic perspective. These initial insights demonstrate the contribution of a dynamic perspective on the IS function itself.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated relationships between SRL and EF in a sample of 254 school-aged adolescent males. Two hypotheses were tested: that self-reported measures of SRL and EF are closely related and that as different aspects of EF mature during adolescence, the corresponding components of SRL should also improve, leading to an age-related increase in the correlation between EF and SRL. Two self-report instruments were used: the strategies for self-regulated learning survey (SSRLS) and the behavioural rating instrument of executive function (BRIEF). Strong correlations between the measures of EF and SRL were found, especially in areas associated with metacognitive processes. Correlations between EF and SRL were found, with weaker correlations between behavioural regulation and SRL were found to be weaker for the younger participants in the sample while the relationship between EF and SRL appears to grow stronger during the initial years of high school even though self-reported levels of EF along with motivation for SRL and important components of SRL such as goal setting and planning were found to decrease with age. Decreasing levels of motivation for learning during adolescence are speculated to moderate the deployment of SRL and EF in a school context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the validity of the Trendelenburg test (TT) using an ultrasound-guided nerve block (UNB) of the superior gluteal nerve and determine whether the reduction in hip abductor muscle (HABD) strength would result in the theorized mechanical compensatory strategies measured during the TT. Design: Quasi-experimental. Setting: Hospital. Participants: Convenience sample of 9 healthy men. Only participants with no current or previous injury to the lumbar spine, pelvis, or lower extremities, and no previous surgeries were included. Interventions: Ultrasound-guided nerve block. Main Outcome Measures: Hip abductor muscle strength (percent body weight [%BW]), contralateral pelvic drop (cPD), change in contralateral pelvic drop (Delta cPD), ipsilateral hip adduction, and ipsilateral trunk sway (TRUNK) measured in degrees. Results: The median age and weight of the participants were 31 years (interquartile range [IQR], 22-32 years) and 73 kg (IQR, 67-81 kg), respectively. An average 52% reduction of HABD strength (z = 2.36, P = 0.02) resulted after the UNB. No differences were found in cPD or Delta cPD (z = 0.01, P = 0.99, z = 20.67, P = 0.49, respectively). Individual changes in biomechanics showed no consistency between participants and nonsystematic changes across the group. One participant demonstrated the mechanical compensations described by Trendelenburg. Conclusions: The TT should not be used as a screening measure for HABD strength in populations demonstrating strength greater than 30% BW but should be reserved for use with populations with marked HABD weakness. Clinical Relevance: This study presents data regarding a critical level of HABD strength required to support the pelvis during the TT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The Trendelenburg Test (TT) is used to assess the functional strength of the hip abductor muscles (HABD), their ability to control frontal plane motion of the pelvis, and the ability of the lumbopelvic complex to transfer load into single leg stance. Rationale: Although a standard method to perform the test has been described for use within clinical populations, no study has directly investigated Trendelenburg’s hypotheses. Purpose: To investigate the validity of the TT using an ultrasound guided nerve block (UNB) of the superior gluteal nerve and determine whether the reduction in HABD strength would result in the theorized mechanical compensatory strategies measured during the TT. Methods: Quasi-experimental design using a convenience sample of nine healthy males. Only subjects with no current or previous injury to the lumbar spine, pelvis, or lower extremities, and no previous surgeries were included. Force dynamometry was used to evaluation HABD strength (%BW). 2D mechanics were used to evaluate contralateral pelvic drop (cMPD), change in contralateral pelvic drop (∆cMPD), ipsilateral hip adduction (iHADD) and ipsilateral trunk sway (TRUNK) measured in degrees (°). All measures were collected prior to and following a UNB on the superior gluteal nerve performed by an interventional radiologist. Results: Subjects’ age was median 31yrs (IQR:22-32yrs); and weight was median 73kg (IQR:67-81kg). An average 52% reduction of HABD strength (z=2.36,p=0.02) resulted following the UNB. No differences were found in cMPD or ∆cMPD (z=0.01,p= 0.99, z=-0.67,p=0.49). Individual changes in biomechanics show no consistency between subjects and non-systematic changes across the group. One subject demonstrated the mechanical compensations described by Trendelenburg. Discussion: The TT should not be used as screening measure for HABD strength in populations demonstrating strength greater than 30%BW but reserved for use with populations with marked HABD weakness. Importance: This study presents data regarding a critical level of HABD strength required to support the pelvis during the TT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – This paper adds to growing research of psychiatric intensive care units (PICU) by recounting descriptions of psychiatric intensive care settings and discusses the perceptions held by nurses of the organisational interfaces, arrangements and provisions of care in these settings. Design/methodology/approach – Data gathered from focus groups held with nurses from two PICUs was used to establish terminology, defining attributes, related concepts, antecedents, values, processes and concepts related to current practices. A literature search was conducted to permit a review of the conceptual arrangements and contemporary understanding of intensive care for people experiencing acute psychiatric illness based on the perspectives held by the nurses from the focus groups. Findings – Dissonance between service needs and the needs and management of individual patients overshadow strategies to implement comprehensive recovery-oriented approaches. Three factors are reported in this paper that influence standards and procedural practice in PICU; organisational structures; physical structures; and subtype nomenclature. Practical implications – Acute inpatient care is an important part of a comprehensive approach to mental health services. Commonly intensive acute care is delivered in specialised wards or units co-located with acute mental health inpatient units mostly known as PICU. Evidence of the most effective treatment and approaches in intensive care settings that support comprehensive recovery for improved outcomes is nascent. Originality/value – Current descriptions from nurses substantiate wide variations in the provisions, design and classifications of psychiatric intensive care. Idiosyncratic and localised conceptions of psychiatric intensive care are not adequately entailing effective treatment and methods in support of recovery principles for improved and comprehensive outcomes. The authors suggest that more concrete descriptions, guidelines, training and policies for provision of intensive psychiatric health care encompassing the perspective of nursing professionals, would reinforce conceptual construction and thus optimum treatments within a comprehensive, recovery-oriented approach to mental health services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Side effects of the medications used for procedural sedation and analgesia in the cardiac catheterisation laboratory are known to cause impaired respiratory function. Impaired respiratory function poses considerable risk to patient safety as it can lead to inadequate oxygenation. Having knowledge about the conditions that predict impaired respiratory function prior to the procedure would enable nurses to identify at-risk patients and selectively implement intensive respiratory monitoring. This would reduce the possibility of inadequate oxygenation occurring. Aim: To identify pre-procedure risk factors for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Design: Retrospective matched case–control. Methods: 21 cases of impaired respiratory function were identified and matched to 113 controls from a consecutive cohort of patients over 18 years of age. Conditional logistic regression was used to identify risk factors for impaired respiratory function. Results: With each additional indicator of acute illness, case patients were nearly two times more likely than their controls to experience impaired respiratory function (OR 1.78; 95% CI 1.19–2.67; p = 0.005). Indicators of acute illness included emergency admission, being transferred from a critical care unit for the procedure or requiring respiratory or haemodynamic support in the lead up to the procedure. Conclusion: Several factors that predict the likelihood of impaired respiratory function were identified. The results from this study could be used to inform prospective studies investigating the effectiveness of interventions for impaired respiratory function during nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory.