948 resultados para Scale validation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Despite the focus on facial photoaging ratings, there are few classifications developed for forearm skin aging assessment.Objective: To develop and validate a clinical scale for the evaluation of forearm skin aging.Methods: Three clinical dermatology faculty members selected, discussed, and appraised the main signs of forearm photoaging. The validation of the resulting scale was performed by 5 assessors who were previously trained to classify 102 photographs of forearms with different degrees of aging. Retests were performed in 15 days.Results: There was significant correlation between the selected variables and the subjective global aging scale. The developed scale showed high internal consistency (Cronbach's alpha = 0.87) and high correlation with the global photoaging scale (rho = 0.92). Inter- and intraobserver final scores showed high agreement.Conclusion: A validated clinical photoaging scale for forearms with internal consistency, reliability, and validity was developed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: The objective of this study was to evaluate the consistency, coherence, and interobserver reliability of the Portuguese version of the Scandinavian Stroke Scale (SSS) in a multicultural population of stroke. Methods: The SSS was translated, culturally adapted, and applied by two independent investigators. This was a randomized transverse study involving two groups: group 1 included 20 patients in the acute phase and group 2 included 20 patients in the subacute phase after stroke was confirmed by computed tomography with a pre-stroke modified Rankin Scale score of 0. Each patient also underwent National Institutes of Health Stroke Scale (NIHSS) evaluation at hospital entry and at the time of the SSS evaluation for correlation with our current standard hospital practice. Consistency and coherence were analyzed by Cronbach’s α and interobserver reliability by ĸ. Results: Forty patients were evaluated with 0.88 consistency and coherence in both stroke phases. Mean interobserver ĸ was 0.76, with reliability considered excellent and good for most scale items, and moderate for only the facial palsy item. Conclusion: The SSS is adequate and validated to study post-stroke patients in a multicultural Brazilian population and in the Portuguese language.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the present work, a multi physics simulation of an innovative safety system for light water nuclear reactor is performed, with the aim to increase the reliability of its main decay heat removal system. The system studied, denoted by the acronym PERSEO (in Pool Energy Removal System for Emergency Operation) is able to remove the decay power from the primary side of the light water nuclear reactor through a heat suppression pool. The experimental facility, located at SIET laboratories (PIACENZA), is an evolution of the Thermal Valve concept where the triggering valve is installed liquid side, on a line connecting two pools at the bottom. During the normal operation, the valve is closed, while in emergency conditions it opens, the heat exchanger is flooded with consequent heat transfer from the primary side to the pool side. In order to verify the correct system behavior during long term accidental transient, two main experimental PERSEO tests are analyzed. For this purpose, a coupling between the mono dimensional system code CATHARE, which reproduces the system scale behavior, with a three-dimensional CFD code NEPTUNE CFD, allowing a full investigation of the pools and the injector, is implemented. The coupling between the two codes is realized through the boundary conditions. In a first analysis, the facility is simulated by the system code CATHARE V2.5 to validate the results with the experimental data. The comparison of the numerical results obtained shows a different void distribution during the boiling conditions inside the heat suppression pool for the two cases of single nodalization and three volume nodalization scheme of the pool. Finaly, to improve the investigation capability of the void distribution inside the pool and the temperature stratification phenomena below the injector, a two and three dimensional CFD models with a simplified geometry of the system are adopted.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: The Conners Adult ADHD Rating Scales (CAARS) assess symptoms specific to adults that are frequently used and have been translated into German. The current study tests the factor structure of the CAARS in a large sample of German adults with ADHD and compares the means of the CAARS subscales with those of healthy German controls. Method: CAARS were completed by 466 participants with ADHD and 851 healthy control participants. Confirmatory factor analysis was used to establish model fit with the American original. Comparisons between participants with ADHD and healthy controls and influences of gender, age, and degree of education were analyzed. Results: Confirmatory factor analysis showed a very good fit with the model for the American original. Differences between ADHD participants and healthy controls on all Conners Adult ADHD Rating Scales-Self-Report (CAARS-S) subscales were substantial and significant. Conclusion: The factor structure of the original American model was successfully replicated in this sample of adult German ADHD participants. (J. of Att. Dis. 2012; XX(X) 1-XX).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We validate, extend, and empirically and theoretically criticize the cultural dimension of humane orientation of the project GLOBE (Global Leadership and Organizational Behavior Effectiveness Research Program). Theoretically, humane orientation is not just a one-dimensionally positive concept about being caring, altruistic, and kind to others as discussed by Kabasakal and Bodur (2004), but there is also a certain ambivalence to this concept. We suggest differentiating humane orientation toward in-group members from humane orientation toward out-group members. A multicountry construct validation study used student samples from 25 countries that were either high or low in humane orientation (N = 876) and studied their relation to the traditional GLOBE scale and other cultural-level measures (agreeableness, religiosity, authoritarianism, and welfare state score). Findings revealed a strong correlation between humane orientation and agreeableness, welfare state score, and religiosity. Out-group humane orientation proved to be the more relevant subfacet of the original humane orientation construct, suggesting that future research on humane orientation should make use of this measure instead of the vague original scale. The ambivalent character of out-group humane orientation is displayed in its positive correlation to high authoritarianism. Patriotism was used as a control variable for noncritical acceptance of one’s society but did not change the correlations. Our findings are discussed as an example of how rigid expectations and a lack of tolerance for diversity may help explain the ambivalent nature of humane orientation

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Careers today increasingly require engagement in proactive career behaviors; however, there is a lack of validated measures assessing the general degree to which somebody is engaged in such career behaviors. We describe the results of six studies with six independent samples of German university students (total N = 2,854), working professionals (total N = 561), and university graduates (N = 141) that report the development and validation of the Career Engagement Scale - a measure of the degree of which somebody is proactively developing her or his career as expressed by diverse career behaviors. The studies provide supprt for measurement invariance across gender and time. In support of convergent and discriminant validity, we find that career engagement is more prevalent among working professionals than among university students and that this scale has incremental validity above several specific career behaviors regarding its relation to vocational identity clarity and career self-efficacy beliefs among students and to job and career satisfaction among employees. In support of incremental predictive validity, beyond the effects of several more specific careeer behaviors, career engagement while at university predicts higher job and career satisfaction several months later after beginning work.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The "Ardouin Scale of Behavior in Parkinson's Disease" is a new instrument specifically designed for assessing mood and behavior with a view to quantifying changes related to Parkinson's disease, to dopaminergic medication, and to non-motor fluctuations. This study was aimed at analyzing the psychometric attributes of this scale in patients with Parkinson's disease without dementia. In addition to this scale, the following measures were applied: the Unified Parkinson's Disease Rating Scale, the Montgomery and Asberg Depression Rating Scale, the Lille Apathy Rating Scale, the Bech and Rafaelsen Mania Scale, the Positive and Negative Syndrome Scale, the MacElroy Criteria, the Patrick Carnes criteria, the Hospital Anxiety and Depression Scale, and the Mini-International Neuropsychiatric Interview. Patients (n = 260) were recruited at 13 centers across four countries (France, Spain, United Kingdom, and United States). Cronbach's alpha coefficient for domains ranged from 0.69 to 0.78. Regarding test-retest reliability, the kappa coefficient for items was higher than 0.4. For inter-rater reliability, the kappa values were 0.29 to 0.81. Furthermore, most of the items from the Ardouin Scale of Behavior in Parkinson's Disease correlated with the corresponding items of the other scales, depressed mood with the Montgomery and Asberg Depression Rating Scale (ρ = 0.82); anxiety with the Hospital Anxiety and Depression Scale-anxiety (ρ = 0.56); apathy with the Lille Apathy Rating Scale (ρ = 0.60). The Ardouin Scale of Behavior in Parkinson's disease is an acceptable, reproducible, valid, and precise assessment for evaluating changes in behavior in patients with Parkinson's disease without dementia. © 2015 International Parkinson and Movement Disorder Society.