980 resultados para SPECT-CT
Resumo:
Objective - Evaluate preventable exposure dose in routine chest CT examinations beyond prescribed anatomical landmarks and estimate extra dose delivered to the patient. Background/rationale - Recent technical advances have greatly increased the clinical applications of CT; developments in multidetector-row CT (MDCT) technology have occurred; the major disadvantage with the increased use of MDCT is associated radiation exposure.
Resumo:
Individualmente nenhuma modalidade imagiológica oferece em simultâneo uma elevada resolução espacial e temporal, aliado a uma boa resolução de contraste e sensibilidade. No entanto, combinações de diferentes modalidades podem aproximar-se deste ideal, permitindo a integração de diferentes sistemas num sistema de imagem única. Um dos marcos históricos da medicina nuclear ocorreu com o aparecimento dos sistemas de Tomografia por Emissão de Positrões/Tomografia Computorizada (PET/CT) que permitem obter, em simultâneo, informações funcionais e anatómicas sobre as alterações metabólicas e estruturais que ocorrem em situações de doença.
Resumo:
Semiquantificação (SQ) nos exames de O DaTScanTM pode apresentar vantagens no diagnóstico de Síndromes Parkinsonianos (SP), especialmente quando os valores utilizados para referência da SQ são adaptados ao serviço em causa. Objetivo do estudo - Criação e validação de bases de dados e valores de referência (VR) adaptados na SQ para diagnóstico de SP recorrendo ao de DaTScanTM, adaptados para o Hospital Infanta Cristina em Badajoz.
Resumo:
Introduction: Anxiety is a common problem in primary care and specialty medical settings. Treating an anxious patient takes more time and adds stress to staff. Unrecognised anxiety may lead to exam repetition, image artifacts and hinder the scan performance. Reducing patient anxiety at the onset is probably the most useful means of minimizing artifactual FDG uptake, both fat brown and skeletal muscle uptake, as well patient movement and claustrophobia. The aim of the study was to examine the effects of information giving on the anxiety levels of patients who are to undergo a PET/CT and whether the patient experience is enhanced with the creation of a guideline. Methodology: Two hundred and thirty two patients were given two questionnaires before and after the procedure to determine their prior knowledge, concerns, expectations and experiences about the study. Verbal information was given by one of the technologists after the completion of the first questionnaire. Results: Our results show that the main causes of anxiety in patients who are having a PET/CT is the fear of the procedure itself, and fear of the results. The patients who suffered from greater anxiety were those who were scanned during the initial stage of a disease. No significant differences were found between the anxiety levels pre procedural and post procedural. Findings with regard to satisfaction show us that the amount of information given before the procedure does not change the anxiety levels and therefore, does not influence patient satisfaction. Conclusions: The performance of a PET/CT scan is an important and statistically generator of anxiety. PET/CT patients are often poorly informed and present with a range of anxieties that may ultimately affect examination quality. The creation of a guideline may reduce the stress of not knowing what will happen, the anxiety created and may increase their satisfaction in the experience of having a PET/CT scan.
Resumo:
Os métodos utilizados pela Medicina moderna no âmbito da Imagem Molecular e na sua capacidade de diagnosticar a partir da “Função do Orgão” em vez da “Morfologia do Orgão”, vieram trazer á componente fundamental desta modalidade da Imagiologia Médica – A Medicina Nuclear – uma importância acrescida, que se tem traduzido num aumento significativo no recurso á sua utilização nas diferentes formas das suas aplicações clínicas. Para além dos aspectos meramente clínicos, que só por si seriam suficientes para ocupar várias dissertações como a presente; a própria natureza desta técnica de imagem, com a sua inerente baixa resolução e tempos longos de aquisição, vieram trazer preocupações acrescidas quanto ás questões relacionadas com a produtividade (nº de estudos a realizar por unidade de tempo); com a qualidade (aumento da resolução da imagem obtida) e, com os níveis de actividade radioactiva injectada nos pacientes (dose de radiação efectiva sobre as populações). Conhecidas que são então as limitações tecnológicas associadas ao desenho dos equipamentos destinados á aquisição de dados em Medicina Nuclear, que apesar dos avanços introduzidos, mantêm mais ou menos inalteráveis os conceitos base de funcionamento de uma Câmara Gama, imaginou-se a alteração significativa dos parâmetros de aquisição (tempo, resolução, actividade), actuando não ao nível das condições técnico-mecânicas dessa aquisição, mas essencialmente ao nível do pós-processamento dos dados adquiridos segundo os métodos tradicionais e que ainda constituem o estado da arte desta modalidade. Este trabalho tem então como objectivo explicar por um lado, com algum pormenor, as bases tecnológicas que desde sempre têm suportado o funcionamento dos sistemas destinados á realização de exames de Medicina Nuclear, mas sobretudo, apresentar as diferenças com os inovadores métodos, que aplicando essencialmente conhecimento (software), permitiram responder ás questões acima levantadas.
Resumo:
Cranial CT scans of eleven immunocompetent children with central nervous system (CNS) infection due to Cryptococcus neoformans var. gattii were retrospectively reviewed. These children had an average age of 8.8 years and positive culture for C. n. var. gattii in cerebrospinal fluid. The most common signs and symptoms were headache, fever, nuchal rigidity, nausea and vomiting. No normal cranial CT was detected in any patient. Hypodense nodules were observed in all patients . The remaining scan abnormalities were as follows: nine had diffuse atrophy, six had hydrocephalus, and five had hydrocephalus coexistent with diffuse atrophy.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
The purpose of our study was to evaluate the accuracy of dynamic incremental bolus-enhanced conventional CT (DICT) with intravenous contrast administration, early phase, in the diagnosis of malignancy of focal liver lesions. A total of 122 lesions were selected in 74 patients considering the following criteria: lesion diameter 10 mm or more, number of lesions less than six per study, except in multiple angiomatosis and the existence of a valid criteria of definitive diagnosis. Lesions were categorized into seven levels of diagnostic confidence of malignancy compared with the definitive diagnosis for acquisition of a receiver-operator-characteristic (ROC) curve analysis and to determine the sensitivity and specificity of the technique. Forty-six and 70 lesions were correctly diagnosed as malignant and benign, respectively; there were 2 false-positive and 4 false-negative diagnoses of malignancy and the sensitivity and specificity obtained were 92 and 97%. The DICT early phase was confirmed as a highly accurate method in the characterization and diagnosis of malignancy of focal liver lesions, requiring an optimal technical performance and judicious analysis of existing semiological data.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
PhD Thesis in Sciences Specialization in Chemistry
Resumo:
OBJECTIVE: To make individual assessments using automated quantification methodology in order to screen for perfusion abnormalities in cerebral SPECT examinations among a sample of subjects with OCD. METHODS: Statistical parametric mapping (SPM) was used to compare 26 brain SPECT images from patients with OCD individually with an image bank of 32 normal subjects, using the statistical threshold of p < 0.05 (corrected for multiple comparisons at the level of individual voxels or clusters). The maps were analyzed, and regions presenting voxels that remained above this threshold were sought. RESULTS: Six patients from a sample of 26 OCD images showed abnormalities at cluster or voxel level, considering the criteria described above, which represented 23.07%. However, seven images from the normal group of 32 were also indicated as cases of perfusional abnormality, representing 21.8% of the sample. CONCLUSION: The automated quantification method was not considered to be a useful tool for clinical practice, for analyses complementary to visual inspection.
Resumo:
Projeto de mestrado em Gestão de Unidades de Saúde
Resumo:
OBJETIVO: Analisar as diferenças relacionadas ao sexo nas medidas obtidas pelos programas Segami e Quantitative Gated SPECT (QGS). MÉTODOS: Cento e oitenta e um indivíduos assintomáticos sem evidência de cardiopatia foram submetidos a estudos de perfusão miocárdica. O volume diastólico final (VDF), volume sistólico final (VSF) e a fração de ejeção do ventrículo esquerdo (FEVE) foram quantificados pelos programas QGS and Segami para avaliar a influência do sexo, idade, peso, altura, freqüência cardíaca, pressão arterial sistólica, pressão arterial diastólica, índice de massa corporal e área de superfície corporal. RESULTADOS: As médias obtidas com o método QGS foram VDF (mulheres = 68 ml; homens = 95 ml; p < 0,001) e FEVE (mulheres = 66,24%; homens = 58,7%), e com o Segami, VDF (mulheres = 137 ml; homens = 174 ml) e FEVE (mulheres = 62,67%; homens = 58,52%). Foram observadas diferenças significantes entre homens e mulheres no VDF (p < 0,001) e VSF (p < 0,001), que persistiram após o ajuste em relação à área de superfície corporal. CONCLUSÃO: Os volumes ventriculares foram significantemente menores e a FEVE foi significantemente maior em mulheres, de acordo com os programas QGS e Segami.
Resumo:
FUNDAMENTO: A doença cardiovascular é a principal causa de morte em diabéticos, tornando-se primordial a identificação dos indivíduos sob maior risco de eventos cardiovasculares. OBJETIVO: Avaliar o valor prognóstico da cintilografia miocárdica de perfusão com " gated SPECT" em pacientes com diabete melito (DM) e suspeita clínica de doença arterial coronariana. MÉTODOS: Estudo retrospectivo envolvendo 232 pacientes diabéticos submetidos à cintilografia miocárdica com " gated SPECT" . Foram avaliados os parâmetros da cintilografia de perfusão (escores e número de segmentos alterados) e da função ventricular (fração de ejeção, volumes e contratilidade do ventrículo esquerdo). Foram considerados eventos cardiovasculares futuros ocorrência de óbito cardíaco, síndrome coronariana isquêmica aguda, procedimentos de revascularização ou acidente vascular encefálico. Foi realizada a análise uni e multivariada pelo modelo de regressão logística múltipla (p < 0,05). RESULTADOS: Estiveram associados com desfechos futuros na análise univariada: idade (p=0,02); angina de peito (p=0,01); tratamento com insulina (p=0,02); anormalidades na perfusão miocárdica (p<0,0001); número de segmentos envolvidos (p=0,0001); escores de perfusão (p=0,0001); fração de ejeção (p=0,004); volume sistólico final (p=0,03) e achado de alteração segmentar na contratilidade do VE (p<0,0001). Na análise multivariada, o sexo masculino (p=0,007), a idade (p=0,03), a angina (p=0,001), o uso de insulina (p=0,007) e o SDS > 3 (p=0,0001) e o número de segmentos alterados > 3 (p=0,0001) foram preditores de eventos. CONCLUSÃO: A cintilografia miocárdica com " gated SPECT" adiciona informações independentes para a estratificação do risco de eventos cardiovasculares futuros em pacientes com diabete melito e suspeita de doença arterial coronariana.