996 resultados para SOLID SAMPLES
Resumo:
Valganciclovir (VGC) is an oral prodrug of ganciclovir (GCV) recently introduced for prophylaxis and treatment of cytomegalovirus infection. Optimal concentration exposure for effective and safe VGC therapy would require either reproducible VGC absorption and GCV disposition or dosage adjustment based on therapeutic drug monitoring (TDM). We examined GCV population pharmacokinetics in solid organ transplant recipients receiving oral VGC, including the influence of clinical factors, the magnitude of variability, and its impact on efficacy and tolerability. Nonlinear mixed effect model (NONMEM) analysis was performed on plasma samples from 65 transplant recipients under VGC prophylaxis or treatment. A two-compartment model with first-order absorption appropriately described the data. Systemic clearance was markedly influenced by the glomerular filtration rate (GFR), patient gender, and graft type (clearance/GFR = 1.7 in kidney, 0.9 in heart, and 1.2 in lung and liver recipients) with interpatient and interoccasion variabilities of 26 and 12%, respectively. Body weight and sex influenced central volume of distribution (V(1) = 0.34 liter/kg in males and 0.27 liter/kg in females [20% interpatient variability]). No significant drug interaction was detected. The good prophylactic efficacy and tolerability of VGC precluded the demonstration of any relationship with GCV concentrations. In conclusion, this analysis highlights the importance of thorough adjustment of VGC dosage to renal function and body weight. Considering the good predictability and reproducibility of the GCV profile after treatment with oral VGC, routine TDM does not appear to be clinically indicated in solid-organ transplant recipients. However, GCV plasma measurement may still be helpful in specific clinical situations.
Resumo:
A solid-phase enzyme immunoassay using both mouse monoclonal and goat polyclonal antibodies against carcinoembryonic antigen (CEA) was developed. The assay detects 0.6 to 1.2 ng of CEA per ml of serum and has 3 incubation steps which can be performed in 1 day. Polystyrene balls coated with polyclonal goat anti-CEA antibodies are first incubated with heat-extracted serum samples. Bound CEA is then detected by addition of mouse monoclonal antibodies, followed by goat IgG anti-mouse IgG1 coupled to alkaline phosphatase. Results with this enzyme immunoassay using monoclonal antibodies (M-EIA) have been compared with those obtained by the conventional inhibition radioimmunoassay (RIA) using goat antiserum. Three hundred and eighty serum samples from 167 patients with malignant or non-malignant diseases and from 134 normal individuals with or without heavy smoking habits were analyzed by the 2 assays. Excellent correlation between the results of the 2 assays was obtained, but the M-EIA, using monoclonal antibodies from a single hybridoma, did not discriminate better than the conventional RIA between CEA produced by different types of carcinoma and between CEA associated with malignant or non-malignant diseases. Follow-up studies of several patients by sequential CEA determinations with the 2 assays showed that the M-EIA was as accurate as the RIA for the detection of tumor recurrences.
Resumo:
Pneumocystis jirovecii pneumonia (PCP) is a common opportunistic infection. Microscopic diagnosis, including diagnosis using the Merifluor-Pneumocystis direct fluorescent antigen (MP-DFA) test, has limitations. Real-time PCR may assist in diagnosis, but no commercially validated real-time PCR assay has been available to date. MycAssay Pneumocystis is a commercial assay that targets the P. jirovecii mitochondrial large subunit (analytical detection limit, ≤3.5 copies/μl of sample). A multicenter trial recruited 110 subjects: 54 with transplants (40 with lung transplants), 32 with nonmalignant conditions, 13 with leukemia, and 11 with solid tumors; 9 were HIV positive. A total of 110 respiratory samples (92% of which were bronchoalveolar lavage [BAL] specimens) were analyzed by PCR. Performance was characterized relative to investigator-determined clinical diagnosis of PCP (including local diagnostic tests), and PCR results were compared with MP-DFA test results for 83 subjects. Thirteen of 14 subjects with PCP and 9/96 without PCP (including 5 undergoing BAL surveillance after lung transplantation) had positive PCR results; sensitivity, specificity, and positive and negative predictive values (PPV and NPV, respectively) were 93%, 91%, 59%, and 99%, respectively. Fourteen of 83 subjects for whom PCR and MP-DFA test results were available had PCP; PCR sensitivity, specificity, PPV, and NPV were 93%, 90%, 65%, and 98%, respectively, and MP-DFA test sensitivity, specificity, PPV, and NPV were 93%, 100%, 100%, and 98%. Of the 9 PCR-positive subjects without PCP, 1 later developed PCP. The PCR diagnostic assay compares well with clinical diagnosis using nonmolecular methods. Additional positive results compared with the MP-DFA test may reflect low-level infection or colonization.
Resumo:
Two concentration methods for fast and routine determination of caffeine (using HPLC-UV detection) in surface, and wastewater are evaluated. Both methods are based on solid-phase extraction (SPE) concentration with octadecyl silica sorbents. A common “offline” SPE procedure shows that quantitative recovery of caffeine is obtained with 2 mL of an elution mixture solvent methanol-water containing at least 60% methanol. The method detection limit is 0.1 μg L−1 when percolating 1 L samples through the cartridge. The development of an “online” SPE method based on a mini-SPE column, containing 100 mg of the same sorbent, directly connected to the HPLC system allows the method detection limit to be decreased to 10 ng L−1 with a sample volume of 100 mL. The “offline” SPE method is applied to the analysis of caffeine in wastewater samples, whereas the “on-line” method is used for analysis in natural waters from streams receiving significant water intakes from local wastewater treatment plants
Resumo:
X-ray diffraction analyses of the pure components n-tricosane and n-pentacosane and of their binary mixed samples have enabled us to characterize the crystalline phases observed at low temperature. On the contrary to what was announced in literature on the structural behavior of mixed samples in odd-odd binary systems with D n = 2, the three domains are not all orthorhombic. This work has enabled us to show that two of the domains are, in fact, monoclinic, (Aa, Z = 4) and the other one is orthorhombic (Pca21, Z = 4). The conclusions drawn in this work can be easily transposed to other binary systems of n-alkanes.
Resumo:
Phosphogysum (PG) or agricultural gypsum, a solid waste from the phosphate fertilizer industry, is used as soil amendment, especially on soils in the Cerrado region, in Brazil. This material may however contain natural radionuclides and metals which can be transferred to soils, plants and water sources. This paper presents and discusses the results of physical and chemical analyses that characterized samples of PG and compares them to the results found in two typical soils of the Cerrado, a clayey and sandy one. These analyses included: solid waste classification, evaluation of organic matter content and of P, K, Ca, Mg, and Al concentrations and of the mineralogical composition. Natural radionuclides and metal concentrations in PG and soil samples were also measured. Phosphogypsum was classified as Class II A - Not Dangerous, Not Inert, Not Corrosive and Not Reactive. The organic matter content in the soil samples was low and potential acidity high. In the mean, the specific 226Ra activity in the phosphogypsum samples (252 Bq kg-1) was below the maximum level recommended by USEPA, which is 370 Bq kg-1 for agricultural use. In addition, this study verified that natural radionuclides and metals concentrations in PG were lower than in the clayey Oxisol of Sete Lagoas, Minas Gerais, Brazil. These results indicated that the application of phosphogypsum as soil amendment in agriculture would not cause a significant impact on the environment.
Resumo:
An exhaustive classification of matrix effects occurring when a sample preparation is performed prior to liquid-chromatography coupled to mass spectrometry (LC-MS) analyses was proposed. A total of eight different situations were identified allowing the recognition of the matrix effect typology via the calculation of four recovery values. A set of 198 compounds was used to evaluate matrix effects after solid phase extraction (SPE) from plasma or urine samples prior to LC-ESI-MS analysis. Matrix effect identification was achieved for all compounds and classified through an organization chart. Only 17% of the tested compounds did not present significant matrix effects.
Resumo:
Solid phase microextraction (SPME) has been widely used for many years in various applications, such as environmental and water samples, food and fragrance analysis, or biological fluids. The aim of this study was to suggest the SPME method as an alternative to conventional techniques used in the evaluation of worker exposure to benzene, toluene, ethylbenzene, and xylene (BTEX). Polymethylsiloxane-carboxen (PDMS/CAR) showed as the most effective stationary phase material for sorbing BTEX among other materials (polyacrylate, PDMS, PDMS/divinylbenzene, Carbowax/divinylbenzene). Various experimental conditions were studied to apply SPME to BTEX quantitation in field situations. The uptake rate of the selected fiber (75 μm PDMS/CAR) was determined for each analyte at various concentrations, relative humidities, and airflow velocities from static (calm air) to dynamic (>200 cm/s) conditions. The SPME method also was compared with the National Institute of Occupational Safety and Health method 1501. Unlike the latter, the SPME approach fulfills the new requirement for the threshold limit value-short term exposure limit (TLV-STEL) of 2.5 ppm for benzene (8 mg/m3).
Resumo:
NlmCategory="UNASSIGNED">Metabolic syndrome after transplantation is a major concern following solid organ transplantation (SOT). The CREB-regulated transcription co-activator 2 (CRTC2) regulates glucose metabolism. The effect of CRTC2 polymorphisms on new-onset diabetes after transplantation (NODAT) was investigated in a discovery sample of SOT recipients (n1=197). Positive results were tested for replication in two samples from the Swiss Transplant Cohort Study (STCS, n2=1294 and n3=759). Obesity and other metabolic traits were also tested. Associations with metabolic traits in population-based samples (n4=46'186, n5=123'865, n6>100,000) were finally analyzed. In the discovery sample, CRTC2 rs8450-AA genotype was associated with NODAT, fasting blood glucose and body mass index (Pcorrected<0.05). CRTC2 rs8450-AA genotype was associated with NODAT in the second STCS replication sample (odd ratio (OR)=2.01, P=0.04). In the combined STCS replication samples, the effect of rs8450-AA genotype on NODAT was observed in patients having received SOT from a deceased donor and treated with tacrolimus (n=395, OR=2.08, P=0.02) and in non-kidney transplant recipients (OR=2.09, P=0.02). Moreover, rs8450-AA genotype was associated with overweight or obesity (n=1215, OR=1.56, P=0.02), new-onset hyperlipidemia (n=1007, OR=1.76, P=0.007), and lower high-density lipoprotein-cholesterol (n=1214, β=-0.08, P=0.001). In the population-based samples, a proxy of rs8450G>A was significantly associated with several metabolic abnormalities. CRTC2 rs8450G>A appears to have an important role in the high prevalence of metabolic traits observed in patients with SOT. A weak association with metabolic traits was also observed in the population-based samples.The Pharmacogenomics Journal advance online publication, 8 December 2015; doi:10.1038/tpj.2015.82.
Resumo:
The technique of solid phase microextraction (SPME) was used for the extraction of halogenated contaminants of water samples from three cities of the State of São Paulo and the extracts were submitted to gas chromatographic analysis with electron capture detection (GC-ECD). In the samples of water collected at the city of São Paulo the detected level of trihalomethanes (THM) expressed as the sum of chloroform, dibromochloromethane and dichlorobromomethane, were higher than the permissible limit established by the Brazilian regulation. In the samples collected at the two other cities the level of any of the three THM remained below the sensitivity of the ECD.
Resumo:
This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).
Resumo:
Ultra-trace amounts of Cu(II) were separated and preconcentrated by solid phase extraction on octadecyl-bonded silica membrane disks modified with a new Schiff,s base (Bis- (2-Hydroxyacetophenone) -2,2-dimethyl-1,3-propanediimine) (SBTD) followed by elution and inductively coupled plasma atomic emission spectrometric detection. The method was applied as a separation and detection method for copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The concentration factor and detection limit of the proposed method are 500 and 12.5 pg mL-1, respectively.
Resumo:
A solid phase extraction procedure using Amberlite XAD-1180/Pyrocatechol violet (PV) chelating resin for the determination of iron and lead ions in various environmental samples was established. The procedure is based on the sorption of lead(II) and iron(III) ions onto the resin at pH 9, followed by elution with 1 mol/L HNO3 and determination by flame atomic absorption spectrometry. The influence of alkaline, earth alkaline and some transition metals, as interferents, are discussed. The recoveries for the spiked analytes were greater than 95%. The detection limits for lead and iron by FAAS were 0.37 µg/L and 0.20 µg/L, respectively. Validation of the method described here was performed by using three certified reference materials (SRM 1515 Apple Leaves, SRM 2711 Montana Soil and NRCC-SLRS-4 Riverine Water). The procedure was successfully applied to natural waters and human hair.
Resumo:
A sensitive preconcentration procedure for spectrophotometeric determination of aluminum was developed. Aluminum as aluminon complex is adsorbed on microcrystalline naphthalene. The naphthalene containing the complex is dissolved in 3 mL of acetone and its absorbance is measured at 544 nm. The effect of various factors on the preconcentration of aluminum was investigated. The calibration graph was linear in the range of 1-60 mg L-1. The limit of detection was 0.52 mg L-1 and relative standard deviation for the determination of 5 mg L-1 was 2.65%. The proposed solid phase extraction procedure was applied to determination of aluminum in food samples.
Resumo:
Nitrate is quantitatively retained with 2,6-bis(4-methoxyphenyl)-4-phenyl pyrylium perchlorate (PPP) on microcrystalline naphthalene in the pH range of 6.5-9.0 from a large volume of aqueous solutions of various samples. The method was based on the complexation between PPP and nitrate and then, extraction of the resulted complex from aqueous solution by microcrystalline naphthalene. The solid mass consisting of the nitrate complex and naphthalene was then dissolved in dimethyl formamide (DMF) and absorption of the resulted solution was obtained at 328 nm. The linear calibration range for the determination of nitrate was 15-135 μg L-1 with the detection limit of 10 μg L-1.