999 resultados para SINGLE-TOOTH IMPLANTS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate in situ changes in the alveolar crest bone height around immediate implant-supported crowns in comparison to tooth-supported crowns (control) with the cervical margins located at the bone crest level, without occlusal load. In Group I, after extraction of 12 mandibular premolars from 4 adult dogs, implants from Branemark System (MK III TiU RP 4.0 x 11.5 mm) were placed to retain complete acrylic crowns. In Group II, premolars were prepared to receive complete metal crowns. Sixteen weeks after placement of the crowns (38 weeks after tooth extraction), the height of the alveolar bone crest was measured with a digital caliper. Data were analyzed statistically by the Mann-Whitney test at 5% significance level. The in situ analysis showed no statistically significant difference (p=0.880) between the implant-supported and the tooth-supported groups (1.528 + 0.459 mm and 1.570 + 0.263 mm, respectively). Based on the findings of the present study, it may be concluded that initial peri-implant bone loss may result from the remodeling process necessary to establish the biological space, similar to which occurs with tooth-supported crowns.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluates the effect of zoledronic acid (ZOL) on the osseointegration of titanium implants in rabbits with glucocorticoid (GC)-induced bone loss, and our findings demonstrated that a single dose of ZOL is able to reverse the detrimental effects of GCs on the osseointegration of titanium implants. The purpose of this study is to evaluate the effect of ZOL on the osseointegration of titanium implants in rabbits with GC-induced bone loss. Three groups of six NZW rabbits were treated for 18 weeks with saline (SALINE), GC (methylprednisolone, 0.35 mg/kg three times a week), or GC + ZOL (methylprednisolone + single dose of ZOL, 0.1 mg/kg). The animals received a titanium implant in the left tibia after 6 weeks and were killed at the 18th week. Bone mineral density (BMD) was measured with dual-energy X-ray absorptiometry at baseline, eighth week (W8), and 18th week (W18) after treatment to determine the change upon treatment (a dagger BMD). Histomorphometric and serum bone alkaline phosphatase analysis (BAP) were also performed. At W8, GC group had a significant reduction in lumbar spine and tibia BMD compared with SALINE (p = 0.003 and p = 0.000), as also observed for GC + ZOL group (p = 0.014 and p = 0.003) just 2 weeks after ZOL treatment. In contrast, at W18, the GC + ZOL had an evident BMD rescue with similar lumbar spine and tibia a dagger BMD compared with SALINE (0.043 +/- 0.006 vs. 0.055 +/- 0.009 g/cm(2), p = 0.457 and 0.027 +/- 0.003 vs. 0.041 +/- 0.011 g/cm(2), p = 0.232) and a significantly higher a dagger BMD compared with the GC (p = 0.024 and p = 0.001). Histomorphometry revealed that osseointegration was significantly reduced in GC (tibia cortical thickness and diameter, bone-implant contact, total and peri-implant bone area) whereas GC + ZOL had these parameters similar to SALINE (p > 0.05). Likewise, ZOL reversed the BAP alteration induced by GC. Our findings demonstrated that a single dose of ZOL is able to reverse the detrimental effects of glucocorticoids on the osseointegration of titanium implants, suggesting that ZOL therapy may improve the outcome of bone implants in patients with glucocorticoid-induced osteoporosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim - To use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for (125)I prostate implants. Background - Dose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect. Materials and Methods - The computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose-volume histograms and EUD for the prostate and rectum. Results - The mean absorbed doses presented deviations of 3.3-4.0% for the prostate and of 2.3-4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D 90 was overestimated by 2.8-3.9% and the rectum D 0.1cc resulted in dose differences of 6-8%. The EUD resulted in an overestimation of 3.5-3.7% for the prostate and of 7.7-8.3% for the rectum. Conclusions - The deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

tabby and downless mutant mice have apparently identical defects in teeth, hair and sweat glands. Recently, genes responsible for these spontaneous mutations have been identified. downless (Dl) encodes Edar, a novel member of the tumour necrosis factor (TNF) receptor family, containing the characteristic extracellular cysteine rich fold, a single transmembrane region and a death homology domain close to the C terminus. tabby (Ta) encodes ectodysplasin-A (Eda) a type II membrane protein of the TNF ligand family containing an internal collagen-like domain. As predicted by the similarity in adult mutant phenotype and the structure of the proteins, we demonstrate that Eda and Edar specifically interact in vitro. We have compared the expression pattern of Dl and Ta in mouse development, taking the tooth as our model system, and find that they are not expressed in adjacent cells as would have been expected. Teeth develop by a well recorded series of epithelial-mesenchymal interactions, similar to those in hair follicle and sweat gland development, the structures found to be defective in tabby and downless mice. We have analysed the downless mutant teeth in detail, and have traced the defect in cusp morphology back to initial defects in the structure of the tooth enamel knot at E13. Significantly, the defect is distinct from that of the tabby mutant. In the tabby mutant, there is a recognisable but small enamel knot, whereas in the downless mutant the knot is absent, but enamel knot cells are organised into a different shape, the enamel rope, showing altered expression of signalling factors (Shh, Fgf4, Bmp4 and Wnt10b). By adding a soluble form of Edar to tooth germs, we were able to mimic the tabby enamel knot phenotype, demonstrating the involvement of endogenous Eda in tooth development. We could not, however, reproduce the downless phenotype, suggesting the existence of yet another ligand or receptor, or of ligand-independent activation mechanisms for Edar. Changes in the structure of the enamel knot signalling centre in downless tooth germs provide functional data directly linking the enamel knot with tooth cusp morphogenesis. We also show that the Lef1 pathway, thought to be involved in these mutants, functions independently in a parallel pathway.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A centralized robust position control for an electrical driven tooth belt drive is designed in this doctoral thesis. Both a cascaded control structure and a PID based position controller are discussed. The performance and the limitations of the system are analyzed and design principles for the mechanical structure and the control design are given. These design principles are also suitable for most of the motion control applications, where mechanical resonance frequencies and control loop delays are present. One of the major challenges in the design of a controller for machinery applications is that the values of the parameters in the system model (parameter uncertainty) or the system model it self (non-parametric uncertainty) are seldom known accurately in advance. In this thesis a systematic analysis of the parameter uncertainty of the linear tooth beltdrive model is presented and the effect of the variation of a single parameter on the performance of the total system is shown. The total variation of the model parameters is taken into account in the control design phase using a Quantitative Feedback Theory (QFT). The thesis also introduces a new method to analyze reference feedforward controllers applying the QFT. The performance of the designed controllers is verified by experimentalmeasurements. The measurements confirm the control design principles that are given in this thesis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hopeless retained primary teeth without permanent successors represent a restorative challenge for clinicians, along with esthetic and functional problems for patients. While various treatment approaches for congenitally missing teeth have been proposed, the replacement of a missing tooth with a dental implant offers specific advantages, such as preservation of the alveolar crest and elimination of the need to restore the adjacent teeth, over other options for tooth replacement. The aim of this article was to illustrate the surgical and prosthetic treatment with implants of a patient with primary teeth without permanent successors. INT J ORAL MAXILLOFAC IMPLANTS 2009;24:151-154

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To evaluate the influence of resorbable membranes on hard tissue alterations and osseointegration at implants placed into extraction sockets in a dog model. Material and methods In the mandibular premolar region, implants were installed immediately into the extraction sockets of six Labrador dogs. Collagen-resorbable membranes were placed at the test sites, while the control sites were left uncovered. Implants were intended to heal in a submerged mode. After 4 months of healing, the animals were sacrificed, and ground sections were obtained for histomorphometric evaluation. Results After 4 months of healing, a control implant was not integrated (n=5). Both at the test and at the control sites, bone resorption occurred. While the most coronal bone-to-implant contact was similar between the test and the control sites, the alveolar bone crest outline was maintained to a higher degree at the buccal aspect of the test sites (loss: 1.7 mm) compared with the control sites (loss: 2.2 mm). Conclusions The use of collagen-resorbable membranes at implants immediately placed into extraction sockets contributed to a partial (23%) preservation of the buccal outline of the alveolar process. To cite this article:Caneva M, Botticelli D, Salata LA, Souza SLS, Carvalho Cardoso L, Lang NP. Collagen membranes at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 21, 2010; 891-897.doi: 10.1111/j.1600-0501.2010.01946.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To evaluate the influence of magnesium-enriched hydroxyapatite (MHA) (SintLife (R)) on bone contour preservation and osseointegration at implants placed immediately into extraction sockets. Material and methods In the mandibular pre-molar region, implants were installed immediately into extraction sockets of six Labrador dogs. MHA was placed at test sites, while the control sites did not receive augmentation materials. Implants were intended to heal in a submerged mode. After 4 months of healing, the animals were sacrificed, and ground sections were obtained for histomorphometric evaluation. Results After 4 months of healing, one control implant was not integrated leaving n=5 test and control implants for evaluation. Both at the test and the control sites, bone resorption occurred. While the most coronal bone-to-implant contact was similar between test and control sites, the alveolar bony crest outline was maintained to a higher degree at the buccal aspect of the test sites (loss: 0.7 mm) compared with the control sites (loss: 1.2 mm), even though this difference did not reach statistical significance. Conclusions The use of MHA to fill the defect around implants placed into the alveolus immediately after tooth extraction did not contribute significantly to the maintenance of the contours of the buccal alveolar bone crest. To cite this article:Caneva M, Botticelli D, Stellini E, Souza SLS, Salata LA, Lang NP. Magnesium-enriched hydroxyapatite at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 22, 2011; 512-517doi: 10.1111/j.1600-0501.2010.02040.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The purpose of this study was to compare and evaluate bone and soft tissue levels between immediately placed, immediately restored implants positioned in the esthetic anterior region with different interimplant distances (IID). Methods: Forty-nine patients requiring multiple implant restorations in the anterior regions received 152 implants, which were restored immediately. Periapical radiographs and digital images of 99 interimplant sites were taken at the regular follow-up examinations at 0, 6, 12, and 24 months after surgery. They were digitally recorded and analyzed. The presence of the interproximal papilla was assessed and compared to the distances between the bone crest and the contact point between the natural teeth and the restoration crowns. Results: Implants with an IID <2 mm seemed to lose less bone laterally. When the IID was <2 mm, vertical crestal bone loss was significantly greater than in the group with IID >4 mm. The percentage of the interproximal papilla presence decreased when the distance between the bone crest and the contact point between the two restoration crowns was >6 mm and when two implants were placed at a distance >= 4 mm. Conclusions: To guarantee a better esthetic result in immediately placed, immediately restored implants, the contact point between the two prosthetic crowns should be placed at 3 to 4 mm, and never >6 mm, from the bone peak. Two adjacent implants should be placed at a distance >2 and <4 mm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To compare the remodeling of the alveolar process at implants installed immediately into extraction sockets by applying a flap or a ""flapless"" surgical approach in a dog model. Material and methods Implants were installed immediately into the distal alveoli of the second mandibular premolars of six Labrador dogs. In one side of the mandible, a full-thickness mucoperiosteal flap was elevated (control site), while contra-laterally, the mucosa was gently dislocated, but not elevated (test site) to disclose the alveolar crest. After 4 months of healing, the animals were sacrificed, ground sections were obtained and a histomorphometric analysis was performed. Results After 4 months of healing, all implants were integrated (n=6). Both at the test and at the control sites, bone resorption occurred with similar outcomes. The buccal bony crest resorption was 1.7 and 1.5 mm at the control and the test sites, respectively. Conclusions ""Flapless"" implant placement into extraction sockets did not result in the prevention of alveolar bone resorption and did not affect the dimensional changes of the alveolar process following tooth extraction when compared with the usual placement of implants raising mucoperiosteal flaps. To cite this article:Caneva M, Botticelli D, Salata LA, Souza SLS, Bressan E, Lang NP. Flap vs. ""flapless"" surgical approach at immediate implants: a histomorphometric study in dogs.Clin. Oral Impl. Res. 21, 2010; 1314-1319.doi: 10.1111/j.1600-0501.2009.01959.x.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The chemical and dimensional stability associated with suitable fracture toughness and propitious tribological characteristics make silicon nitride-based ceramics potential candidates for biomedical applications, mainly as orthopedic implants. Considering this combination of properties, silicon nitride components were investigated in relation to their biocompatibility. For this study, two cylindrical implants were installed in each tibia of five rabbits and were kept in the animals for 8 weeks. During the healing time, tissue tracers were administrated in the animals so as to evaluate the bone growth around the implants. Eight weeks after the surgery, the animals were euthanized and histological analyses were performed. No adverse reactions were observed close to the implant. The osteogenesis process occurred during the entire period defined by the tracers. However, this process occurred more intensely 4 weeks after the surgery. In addition, the histological analyses showed that bone growth occurred preferentially in the cortical areas. Different kinds of tissue were identified on the implant surface, characterized by lamellar bone tissue containing osteocytes and osteons, by a noncalcified matrix containing osteoblasts, or by the presence of collagen III, which may change to collagen I or remain as a fibrous tissue. The results demonstrated that silicon nitride obtained according to the procedure proposed in this research is a biocompatible material. (c) 2007 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions.Materials and Methods: the materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C.Results: None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used.Conclusion: the results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and Methods:Two models were made of photoelastic resin PL-2, with an internal hexagon implant of 4.00 x 13 mm and another with an external hexagon implant of 4.00 x 13 mm. Three denture designs were fabricated for each implant model, incorporating one type of connection in each one to connect implants and teeth: 1) welded rigid connection; 2) semirigid connection; and 3) rigid connection with occlusal screw. The models were placed in the polariscope, and 100-N axial forces were applied on fixed points on the occlusal surface of the dentures.Results:There was a trend toward less intensity in the stresses on the semirigid connection and solid rigid connection in the model with the external hexagon; among the three types of connections in the model with the internal hexagon implant, the semirigid connection was the most unfavorable one; in the tooth-implant association, it is preferable to use the external hexagon implant.Conclusions:The internal hexagon implant establishes a greater depth of hexagon retention and an increase in the level of denture stability in comparison with the implant with the external hexagon. However, this greater stability of the internal hexagon generated greater stresses in the abutment structures. Therefore, when this association is necessary, it is preferable to use the external hexagon implant.