899 resultados para Return of results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Five test runs were performed to assess possible bias when performing the loss on ignition (LOI) method to estimate organic matter and carbonate content of lake sediments. An accurate and stable weight loss was achieved after 2 h of burning pure CaCO3 at 950 °C, whereas LOI of pure graphite at 530 °C showed a direct relation to sample size and exposure time, with only 40-70% of the possible weight loss reached after 2 h of exposure and smaller samples losing weight faster than larger ones. Experiments with a standardised lake sediment revealed a strong initial weight loss at 550 °C, but samples continued to lose weight at a slow rate at exposure of up to 64 h, which was likely the effect of loss of volatile salts, structural water of clay minerals or metal oxides, or of inorganic carbon after the initial burning of organic matter. A further test-run revealed that at 550 °C samples in the centre of the furnace lost more weight than marginal samples. At 950 °C this pattern was still apparent but the differences became negligible. Again, LOI was dependent on sample size. An analytical LOI quality control experiment including ten different laboratories was carried out using each laboratory's own LOI procedure as well as a standardised LOI procedure to analyse three different sediments. The range of LOI values between laboratories measured at 550 °C was generally larger when each laboratory used its own method than when using the standard method. This was similar for 950 °C, although the range of values tended to be smaller. The within-laboratory range of LOI measurements for a given sediment was generally small. Comparisons of the results of the individual and the standardised method suggest that there is a laboratory-specific pattern in the results, probably due to differences in laboratory equipment and/or handling that could not be eliminated by standardising the LOI procedure. Factors such as sample size, exposure time, position of samples in the furnace and the laboratory measuring affected LOI results, with LOI at 550 °C being more susceptible to these factors than LOI at 950 °C. We, therefore, recommend analysts to be consistent in the LOI method used in relation to the ignition temperatures, exposure times, and the sample size and to include information on these three parameters when referring to the method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anitta Müller-Cohen

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is an overview of the results from a questionnaire survey and subsequent supplementary interviews of Iran's large apparel firms conducted by the author in 2009-2011. Most of the large apparel firms in Iran are based in Tehran and have been in business for some twenty years. They have a solid business with regular customers, but in general have hesitated to expand the size of their firms. Following the relaxation of restrictions on the procurement of raw materials that existed in the 1990s, the results of survey and interviews show that the firms have developed new channels of procurement although they depend to a considerable degree on imported raw materials and machinery. They have managed to maintain their level of output even with the rapid increase in imports since 2000, although the number of firms has decreased. Low-priced Chinese products have basically not been their rivals; instead, the inflow of foreign name-brand products have hit them heavily.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simplified CFD wake model based on the actuator disk concept is used to simulate the wind turbine, represented by a disk upon which a distribution of forces, defined as axial momentum sources, are applied on the incoming non-uniform flow. The rotor is supposed to be uniformly loaded, with the exerted forces function of the incident wind speed, the thrust coefficient and the rotor diameter. The model is tested under different parameterizations of turbulence models and validated through experimental measurements downwind of a wind turbine in terms of wind speed deficit and turbulence intensity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work aims at a deeper understanding of the energy loss phenomenon in polysilicon production reactors by the so-called Siemens process. Contributions to the energy consumption of the polysilicon deposition step are studied in this paper, focusing on the radiation heat loss phenomenon. A theoretical model for radiation heat loss calculations is experimentally validated with the help of a laboratory CVD prototype. Following the results of the model, relevant parameters that directly affect the amount of radiation heat losses are put forward. Numerical results of the model applied to a state-of-the-art industrial reactor show the influence of these parameters on energy consumption due to radiation per kilogram of silicon produced; the radiation heat loss can be reduced by 3.8% when the reactor inner wall radius is reduced from 0.78 to 0.70 m, by 25% when the wall emissivity is reduced from 0.5 to 0.3, and by 12% when the final rod diameter is increased from 12 to 15 cm.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To assess the net 5 year effects of intervention of a community based demonstration project, the Heartbeat Wales programme, on modifiable behavioural risks for prevention of cardiovascular disease.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Document concerns how certain lands around Casco Bay, York Co., Maine, were partitioned in accordance with an order of a writ.