945 resultados para Redispatch of active power


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Design of a series-connected photovoltaic generator (SPVG) capable of enhancing power quality is investigated. Analysis of the SPVG operations under disturbance conditions shows explicitly how achievable network voltage quality is affected by the SPVG injected power and its apparent power rating, and that voltage quality can be significantly improved even with a modest level of energy storage capacity incorporated in the SPVG. A control system for the SPVG is also proposed. Both simulation and laboratory tests confirm the efficacy of the distributed generator system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electrification of vehicular systems has gained increased momentum in recent years with particular attention to constant power loads (CPLs). Since a CPL potentially threatens system stability, stability analysis of hybrid electric vehicle with CPLs becomes necessary. A new power buffer configuration with battery is introduced to mitigate the effect of instability caused by CPLs. Model predictive control (MPC) is applied to regulate the power buffer to decouple source and load dynamics. Moreover, MPC provides an optimal tradeoff between modification of load impedance, variation of dc-link voltage and battery current ripples. This is particularly important during transients or starting of system faults, since battery response is not very fast. Optimal tradeoff becomes even more significant when considering low-cost power buffer without battery. This paper analyzes system models for both voltage swell and voltage dip faults. Furthermore, a dual mode MPC algorithm is implemented in real time offering improved stability. A comprehensive set of experimental results is included to verify the efficacy of the proposed power buffer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The focus of this research is the creation of a stage-directing training manual on the researcher's site at the National Institute of Dramatic Art. The directing procedures build on the work of Stanislavski's Active Analysis and findings from present-day visual cognition studies. Action research methodology and evidence-based data collection are employed to improve the efficacy of both the directing procedures and the pedagogical manual. The manual serves as a supplement to director training and a toolkit for the more experienced practitioner. The manual and research findings provide a unique and innovative contribution to the field of theatre directing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been shown that active control of locomotion increases accuracy and precision of nonvisual space perception, but psychological mechanisms of this enhancement are poorly understood. The present study explored a hypothesis that active control of locomotion enhances space perception by facilitating crossmodal interaction between visual and nonvisual spatial information. In an experiment, blindfolded participants walked along a linear path under one of the following two conditions: (1) They walked by themselves following a guide rope; and (2) they were led by an experimenter. Subsequently, they indicated the walked distance by tossing a beanbag to the origin of locomotion. The former condition gave participants greater control of their locomotion, and thus represented a more active walking condition. In addition, before each trial, half the participants viewed the room in which they performed the distance perception task. The other half remained blindfolded throughout the experiment. Results showed that although the room was devoid of any particular cues for walked distances, visual knowledge of the surroundings improved the precision of nonvisual distance perception. Importantly, however, the benefit of preview was observed only when participants walked more actively. This indicates that active control of locomotion allowed participants to better utilize their visual memory of the environment for perceiving nonvisually encoded distance, suggesting that active control of locomotion served as a catalyst for integrating visual and nonvisual information to derive spatial representations of higher quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the application low-temperature plasmas for roughening Si surfaces which is becoming increasingly important for a number of applications ranging from Si quantum dots to cell and protein attachment for devices such as "laboratory on a chip" and sensors. It is a requirement that Si surface roughening is scalable and is a single-step process. It is shown that the removal of naturally forming SiO2 can be used to assist in the roughening of the surface using a low-temperature plasma-based etching approach, similar to the commonly used in semiconductor micromanufacturing. It is demonstrated that the selectivity of SiO2 /Si etching can be easily controlled by tuning the plasma power, working gas pressure, and other discharge parameters. The achieved selectivity ranges from 0.4 to 25.2 thus providing an effective means for the control of surface roughness of Si during the oxide layer removal, which is required for many advance applications in bio- and nanotechnology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A challenge for regulators and the courts has been establishing the boundary between behaviour is exclusionary and should be condemned under s 46 of the then Trade Practices Act 1974 (Cth) (TPA), now s 46 of the Competition and Consumer Act 2010 (Cth) (CCA), and behaviour that is not exclusionary and might even be pro-competitive. This boundary can be especially difficult to draw in the case of entry deterring strategies. Section 46(1) prohibits corporations with a substantial degree of market power from taking advantage of that market power for one of the statutorily proscribed purposes which include preventing the entry of a person into that or any other market. Section 45(2) separately prohibits corporations from making and giving effect to contracts arrangements and understandings that have the purpose, effect or likely effect of substantially lessening competition in a market. The latest case in which the ACCC has failed to satisfy the s 46 criteria is the decision of Greenwood J in ACCC v Cement Australia Pty Ltd [2013] FCA 909 (Cement Australia case). Final orders were published in a separate judgment, in ACCC v Cement Australia Pty Ltd [2014] FCA 148 (28 February 2014). The case concerned an entry deterring strategy, namely the pre-emptive buying of input factors in an upstream market to protect an incumbent with substantial market power in a downstream market and to prevent new entry in the downstream market. Greenwood J found that while Cement Australia Pty Ltd, formerly known as Queensland Cement Ltd (QCL), had substantial market power, its conduct in entering into the pre-emptive contracts was not a contravention of s 46, because Cement Australia had not “taken advantage” of its market power. However, since Cement Australia’s purpose in entering into the pre-emptive contracts was anti-competitive, they were held to contravene s 45(2) of the TPA. The purpose of this Note is to consider only the reasons for judgment in the Cement Australia case in relation to the “taking advantage” element. The judgment was handed down on 10 September 2013. The final hearing date was 15 July 2011, so it was long-awaited. At 714 pages, it is carefully drafted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: We examine the interaction between trait resilience and control in predicting coping and performance. Drawing on a person–environment fit perspective, we hypothesized resilient individuals would cope and perform better in demanding work situations when control was high. In contrast, those low in resilience would cope and perform better when control was low. Recognizing the relationship between trait resilience and performance also could be indirect, adaptive coping was examined as a mediating mechanism through which high control enables resilient individuals to demonstrate better performance. Methodology: In Study 1 (N = 78) and Study 2 (N = 94), participants completed a demanding inbox task in which trait resilience was measured and high and low control was manipulated. Study 3 involved surveying 368 employees on their trait resilience, control, and demand at work (at Time 1), and coping and performance 1 month later at Time 2. Findings: For more resilient individuals, high control facilitated problem-focused coping (Study 1, 2, and 3), which was indirectly associated with higher subjective performance (Study 1), mastery (Study 2), adaptive, and proficient performance (Study 3). For more resilient individuals, high control also facilitated positive reappraisal (Study 2 and 3), which was indirectly associated with higher adaptive and proficient performance (Study 3). Implications: Individuals higher in resilience benefit from high control because it enables adaptive coping. Originality/value: This research makes two contributions: (1) an experimental investigation into the interaction of trait resilience and control, and (2) investigation of coping as the mechanism explaining better performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Australian subacute inpatient rehabilitation facilities face significant challenges from the ageing population and the increasing burden of chronic disease. Foot disease complications are a negative consequence of many chronic diseases. With the rapid expansion of subacute rehabilitation inpatient services, it seems imperative to investigate the prevalence of foot disease and foot disease risk factors in this population. The primary aim of this cross-sectional study was to determine the prevalence of active foot disease and foot disease risk factors in a subacute inpatient rehabilitation facility. Methods Eligible participants were all adults admitted at least overnight into a large Australian subacute inpatient rehabilitation facility over two different four week periods. Consenting participants underwent a short non-invasive foot examination by a podiatrist utilising the validated Queensland Health High Risk Foot Form to collect data on age, sex, medical co-morbidity history, foot disease risk factor history and clinically diagnosed foot disease complications and foot disease risk factors. Descriptive statistics were used to determine the prevalence of clinically diagnosed foot disease complications, foot disease risk factors and groups of foot disease risk factors. Logistic regression analyses were used to investigate any associations between defined explanatory variables and appropriate foot disease outcome variables. Results Overall, 85 (88%) of 97 people admitted to the facility during the study periods consented; mean age 80 (±9) years and 71% were female. The prevalence (95% confidence interval) of participants with active foot disease was 11.8% (6.3 – 20.5), 32.9% (23.9 – 43.5) had multiple foot disease risk factors, and overall, 56.5% (45.9 – 66.5) had at least one foot disease risk factor. A self-reported history of peripheral neuropathy diagnosis was independently associated with having multiple foot disease risk factors (OR 13.504, p = 0.001). Conclusion This study highlights the potential significance of the burden of foot disease in subacute inpatient rehabilitation facilities. One in eight subacute inpatients were admitted with active foot disease and one in two with at least one foot disease risk factor in this study. It is recommended that further multi-site studies and management guidelines are required to address the foot disease burden in subacute inpatient rehabilitation facilities. Keywords: Subacute; Inpatient; Foot; Complication; Prevalence

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This book focuses on how evolutionary computing techniques benefit engineering research and development tasks by converting practical problems of growing complexities into simple formulations, thus largely reducing development efforts. This book begins with an overview of the optimization theory and modern evolutionary computing techniques, and goes on to cover specific applications of evolutionary computing to power system optimization and control problems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

为研究风电并网对互联系统低频振荡的影响,基于完整的双馈风电机组模型,定性分析了两区域互联系统在风电机组并网前后阻尼特性的变化情况.从双馈风电机组并网输送距离、并网容量、互联系统联络线传送功率、是否加装电力系统稳定器等多个方面,多角度分析了风电场并网对互联系统小干扰稳定及低频振荡特性的影响.之后,以两个包括两个区域的电力系统为例,进行了系统的计算分析和比较.结果表明,有双馈风电机组接入的互联电力系统,在不同运行模式下,双馈风电机组的并网输送距离、出力水平、联络线传送功率对低频振荡模式的影响在趋势和程度上均有显著差异,这样在对风电场进行入网规划、设计和运行时就需要综合考虑这些因素的影响.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of multilevel control strategies for load-frequency control of interconnected power systems is assuming importance. A large multiarea power system may be viewed as an interconnection of several lower-order subsystems, with possible change of interconnection pattern during operation. The solution of the control problem involves the design of a set of local optimal controllers for the individual areas, in a completely decentralised environment, plus a global controller to provide the corrective signal to account for interconnection effects. A global controller, based on the least-square-error principle suggested by Siljak and Sundareshan, has been applied for the LFC problem. A more recent work utilises certain possible beneficial aspects of interconnection to permit more desirable system performances. The paper reports the application of the latter strategy to LFC of a two-area power system. The power-system model studied includes the effects of excitation system and governor controls. A comparison of the two strategies is also made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents three methodologies for determining optimum locations and magnitudes of reactive power compensation in power distribution systems. Method I and Method II are suitable for complex distribution systems with a combination of both radial and ring-main feeders and having different voltage levels. Method III is suitable for low-tension single voltage level radial feeders. Method I is based on an iterative scheme with successive powerflow analyses, with formulation and solution of the optimization problem using linear programming. Method II and Method III are essentially based on the steady state performance of distribution systems. These methods are simple to implement and yield satisfactory results comparable with the results of Method I. The proposed methods have been applied to a few distribution systems, and results obtained for two typical systems are presented for illustration purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The theory of transient mode locking for an active modulator in an intracavity frequency-doubled laser is presented. The theory is applied to mode-locked and intracavity frequency-doubled Nd:YAG laser and the mode-locked pulse width is plotted as a function of number of round trips inside the cavity. It is found that the pulse compression is faster and the system takes a very short time to approach the steady state in the presence of a second harmonic generating crystal inside the laser cavity. The effect of modulation depth and the second harmonic conversion efficiency on the temporal behavior of the pulse width is discussed. Journal of Applied Physics is copyrighted by The American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of multilevel control strategies for load-frequency control of interconnected power systems is assuming importance. A large multiarea power system may be viewed as an interconnection of several lower-order subsystems, with possible change of interconnection pattern during operation. The solution of the control problem involves the design of a set of local optimal controllers for the individual areas, in a completely decentralised environment, plus a global controller to provide the corrective signal to account for interconnection effects. A global controller, based on the least-square-error principle suggested by Siljak and Sundareshan, has been applied for the LFC problem. A more recent work utilises certain possible beneficial aspects of interconnection to permit more desirable system performances. The paper reports the application of the latter strategy to LFC of a two-area power system. The power-system model studied includes the effects of excitation system and governor controls. A comparison of the two strategies is also made.