929 resultados para Ray-gama
Resumo:
The pentadentate chelating agent, 2,6-diacetylpyridinebis(S-benzyldithiocarbazate) (H2SNNNS) reacts with zinc(II) and cadmium(II) ions forming stable complexes of empirical formula, [M(SNNNS)] (M=Zn2+, Cd2+; SNNNS2 =doubly deprotonated anionic form of the Schiff base). These complexes have been characterized by a variety of physico-chemical techniques. IR and H-1 NMR spectral evidence indicate that the Schiff base coordinates to the zinc(II) and cadmium(II) ions via the pyridine nitrogen atoms, the azomethine nitrogen atoms and the mercaptide sulfur atoms. The crystal and molecular structure of the zinc(II) complex has been determined by X-ray diffraction. The complex is a dimer in which the pyridine nitrogen atom,the azomethine nitrogen atom and the thiolate sulfur atom from one ligand coordinate to one of the zinc(II) ions whereas the azomethine and thiolate sulfur atoms from another ligand complete pentacoordination around the zinc(II) ion, the ligands being coordinated in their deprotonated forms. The coordination geometry about each zinc(II) can be considered as intermediate between a square-pyramid and trigonal-bipyramid. The cadmium(II) complex is also assigned with a dimeric structure. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Regiospecific bromination of 2,4,4-trimethyl-cyclohex-2-enone was achieved and the X-ray crystal structure of 6-bromo-2,4,4-trimethyl-cyclohex-2-enone is presented.
Resumo:
9-Carboxyhexahydro-7-methoxy-4a,7-ethano-benzopyran-5-en-1-one (1) was prepared and examined by X-ray crystallography to probe its potential as a new peptide scaffold/template. The crystal structure of the anhydride precursor 7-(2-acetoxyethyl)-4-methoxy-3a,4,7,7a-tetrahydro-4,7-ethanoisobenzofuran-1,3-dione (6) is also reported.
Resumo:
A aplicação da radiação ionizante, com o propósito de garantir a segurança dos grãos, tem sido apresentada como alternativa eficaz e segura ao uso de defensivos agrícolas e prática promissora, a ser utilizada para estender a vida útil e reduzir as perdas das safras de grãos. Contudo, assim como outros tratamentos de conservação de alimentos, a irradiação pode alterar sua qualidade. Este trabalho foi realizado com o objetivo de avaliar a qualidade de cocção do arroz submetido a diferentes doses de irradiação gama Co60 (0,0 kGy, 6,5 kGy e 7,5 kGy). Observou-se que o arroz irradiado com 7,5 kGy apresentou um tempo de cozimento significativamente maior (18,21 min.) que o do arroz irradiado na dose 6,5 kGy (17,11 min) e 0,0 kGy (16,83 min.). Os valores médios de expansão do volume do arroz não irradiado foi de 365,65%; já, para o arroz irradiado, os valores foram menores, apresentando-se com 322,19%. Quanto à perda de sólidos solúveis, essa foi significativamente maior no arroz branco polido irradiado (17,0%), do que no arroz não irradiado (10,35%). Embora a irradiação gama tenha influenciado em alguns parâmetros de cocção do arroz, refletindo-se em maior tempo de cozimento, para a irradiação na dose 7,5 kGy, no menor coeficiente de expansão do volume e na maior perda de sólidos solúveis, os valores encontrados assemelham-se aos valores referenciados, na literatura, como desejáveis para a qualidade deste cereal.
Resumo:
Dental implant recognition in patients without available records is a time-consuming and not straightforward task. The traditional method is a complete user-dependent process, where the expert compares a 2D X-ray image of the dental implant with a generic database. Due to the high number of implants available and the similarity between them, automatic/semi-automatic frameworks to aide implant model detection are essential. In this study, a novel computer-aided framework for dental implant recognition is suggested. The proposed method relies on image processing concepts, namely: (i) a segmentation strategy for semi-automatic implant delineation; and (ii) a machine learning approach for implant model recognition. Although the segmentation technique is the main focus of the current study, preliminary details of the machine learning approach are also reported. Two different scenarios are used to validate the framework: (1) comparison of the semi-automatic contours against implant’s manual contours of 125 X-ray images; and (2) classification of 11 known implants using a large reference database of 601 implants. Regarding experiment 1, 0.97±0.01, 2.24±0.85 pixels and 11.12±6 pixels of dice metric, mean absolute distance and Hausdorff distance were obtained, respectively. In experiment 2, 91% of the implants were successfully recognized while reducing the reference database to 5% of its original size. Overall, the segmentation technique achieved accurate implant contours. Although the preliminary classification results prove the concept of the current work, more features and an extended database should be used in a future work.
Resumo:
A chegada de Vasco da Gama à Índia marcou o início de uma nova era na história da Índia e do mundo. Foi um encontro marcado por colaboração e resistências. Tanto os indianos como os portugueses faziam cedências por necessidade ou por conveniências. Não se pode ignorar neste processo o impacto dos renegados portugueses que se espalharam pela Asia toda. Era o resultado da "grande soltura" após a morte de Afonso de Albuquerque que acreditava numa economia comandada. O império da sombra, tão bem descrito por Fernão Mendes Pinto prevaleceu.
Resumo:
Os soros antitetânico, antidiftérico e antibotrópico-crotálico e, ainda, a vacina diftérica-pertussis-tetânica foram submetidos a diferentes intensidades de radiação gama, com os seguintes intuitos: verificação da resistência das atividades específicas destes produtos à ação dos raios gama; avaliação das possibilidades de utilização deste tipo de energia radiante para a esterilização de alguns soros hiperimunes heterólogos e vacinas, mais comumente utilizados em saúde pública. Os resultados obtidos, segundo os parâmetros empregados, mostraram a possibilidade de esterilização sem alterações das atividades específicas, de ordem biológica ou química, dos produtos experimentados.
Resumo:
This article reports on a-Si:H-based low-leakage blue-enhanced photodiodes for dual-screen x-ray imaging detectors. Doped nanocrystalline silicon was incorporated in both the n- and p-type regions to reduce absorption losses for light incoming from the top and bottom screens. The photodiode exhibits a dark current density of 900 pA/cm(2) and an external quantum efficiency up to 90% at a reverse bias of 5 V. In the case of illumination through the tailored p-layer, the quantum efficiency of 60% at a 400 nm wavelength is almost double that for the conventional a-Si:H n-i-p photodiode.
Resumo:
Introdução – A monitorização da exposição ocupacional a doses de radiação ionizante pode ser complementada por dosímetros eletrónicos individuais que permitem uma leitura direta da dose de radiação recebida. Dada a dependência energética e de débito de dose já reportada para estes dosímetros, este trabalho pretende determinar a linearidade da resposta de um dosímetro eletrónico individual e estudar o comportamento da sua resposta em função da energia de radiação e do débito de dose. Metodologia – Para estudar a dependência da energia da radiação do dosímetro eletrónico pessoal Vertec Bleeper Sv procedeu‑se à sua irradiação com um equivalente de dose individual, Hp(10), de 500 μSv de radiação gama do Cobalto – 60 (60C) e Césio – 137 (137Cs) e das qualidades de radiação X da série Narrow (N): N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. Para investigar a dependência da resposta em função do débito de dose aplicaram‑se à ampola de raios X as intensidades de corrente elétrica de 1 mA, 5 mA, 10 mA, 15 mA e 20 mA. Resultados – Não existe uma relação entre a resposta do detetor e a energia de radiação a que este é exposto. Ocorre uma subestimação superior a 50% na grandeza medida para energias inferiores a 33 keV, mas ostenta uma medida relativamente linear da grandeza Hp(10) para doses inferiores a 100 μSv. Também se constata que, à medida que o débito de dose aumenta, existe uma diminuição na resposta do dosímetro. O menor decréscimo na resposta deste dosímetro eletrónico individual dá‑se para as qualidades de radiação N‑30 (1,1%), N‑40 (4,1%) e N‑120 (20,0%). Conclusão – Verifica‑se que a resposta do dosímetro individual Vertec Bleeper Sv depende fortemente da energia da radiação e do débito de dose. ABSTRACT: Introduction – The measurement of occupational exposure to radiation doses can be completed with an electronic personal dosemeter that allows a direct reading and alarm function of the received radiation dose. Due to the energy and dose rate dependence already reported for this type of dosemeter, it is intended, with this work, to determine the response linearity of an Electronic Personal Dosemeter and to study its response behavior to the dose rate and radiation energy. Methodology – The electronic personal dosemeter Vertec Bleeper Sv energy dependency was evaluated by its irradiation with 500 μSv from the radionuclides Cobalt – 60 (60C) and Cesium – 137 (137Cs) as well as by the radiation qualities of the Narrow (N) series: N‑30, N‑40, N‑60, N‑80, N‑100 e N‑120. To investigate the dose rate dependency, the intensities of electric current of 1 mA, 5 mA, 10 mA, 15 mA and 20 mA were applied to the X‑ray tube. Results – There is no relationship between the response of the detector and the radiation energy. For energies below 33 keV there is an underestimation over 50% of the radiation dose measured but the detector presents a linear response for energies under 100 μSv. A dependency on the dose rate is perceived since as the dose rate increases, the response of the individual monitor decreases. There is a smaller decrease for the radiation qualities of N‑30 (1.1%), N‑40 (4.1%) and N‑120 (20.0%). Conclusion – It is concluded that there is a strong dependence of radiation energy and dose rate on the response of an electronic personal dosemeter.
Resumo:
A obesidade e a diabetes mellitus tipo 2 (DM2) são considerados dois grandes problemas de saúde pública. A má alimentação e a falta de atividade física encontram-se entre os principais desencadeadores de um crescente número de indivíduos obesos, diabéticos e com sensibilidade à insulina diminuída. Este aumento tem motivado a comunidade científica a investigar cada vez mais para o elevado contributo da herança genética associada aos fatores sociais e nutricionais. O gene dos recetores ativados por proliferadores do peroxissoma gama 2 (PPARγ2) desempenha um papel importante no metabolismo lipídico. Uma vez que o PPARγ2 é maioritariamente expresso no tecido adiposo, uma redução moderada da sua atividade tem influência na sensibilidade à insulina, diabetes, e outros parâmetros metabólicos. Vários estudos sugerem que tanto fatores genéticos como fatores ambientais (tais como a dieta), poderão estar envolvidos na formação de padrões associados ao polimorfismo Pro12Ala com a composição corporal em diferentes populações humanas. Os diversos estudos genéticos envolvendo o estudo do polimorfismo Pro12Ala do PPARγ2 na suscetibilidade de possuir risco de diabetes e obesidade em várias populações têm proposto conclusões diversas. Em alguns parece haver mais associações do que outros e, às vezes, não demonstram sequer associação. Desta forma, o presente trabalho teve como objectivo contribuir para a elucidação do impacto do polimorfismo Pro12Ala do PPARγ2 na resistência à insulina associada à DM2 e na obesidade, mediante estudo sistematizado da literatura existente até à data, através de meta análise. Do total de uma pesquisa de 63 publicações, foram incluídos 32 artigos no presente estudo, sendo que destes 25 foram incluídos na síntese qualitativa e 11 incluídos na sintese quantitativa. No presente trabalho pode-se concluir que existe evidência estatística que suporta a hipótese de que o polimorfismo Pro12Ala do PPARγ2 pode ser considerado um fator protetor para a DM2 [p <0,05 e OR (odds ratio) 0,702, com IC (intervalos de confiança) com valores que nunca incluem o 1]. No entanto, e mediante os mesmos pressupostos, o mesmo polimorfismo pode ser considerado um fator de risco ao desenvolvimento de obesidade, pela evidência estatística [p <0,05 e OR de 1,196, com IC com valores que nunca incluem o 1].
Resumo:
Novel [Ru(L)(Tpms)]Cl and [Ru(L)(Tpms(Ph))]Cl complexes (L = p-cymene, benzene, or hexamethylbenzene, Tpms = tris(pyrazolyl)-methanesulfonate, Tpms(Ph) = tris(3-phenylpyrazoly)methanesulfonate) have been prepared by reaction of [Ru(L)(mu-Cl)(2)](2) with Li[Tpms] and Li[Tpms(Ph)], respectively. [Ru(p-cymene)(Tpms)]BF4 has been synthesized through a metathetic reaction of [Ru(p-cymene)(Tpms)]Cl with AgBF4. [RuCl(cod)(Tpms)] (cod = 1,5-cyclooctadiene) and [RuCl(cod)(Tpms(Ph))] are also reported, being obtained by reaction of [RuCl2(cod)(MeCN)(2)] with Li[Tpms] and Li[Tpms(Ph)], respectively. The structures of the complexes and the coordination modes of the ligands have been established by IR, NMR, and single-crystal X-ray diffraction (for [RuL(Tpms)]X (L = p-cymene or HMB, X = Cl; L = p-cymene, X = BF4)) studies. Electrochemical studies showed that each complex undergoes a single-electron R-II -> R-III oxidation at a potential measured by cyclic voltammetry, allowing to compare the electron-donor characters of the tris(pyrazolyl)methanesulfonate and arene ligands, and to estimate, for the first time, the values of the Lever E-L ligand parameter for Tmps(Ph), HMB, and cod.
Resumo:
A institucionalização do direito à saúde, na constituição de 1976, como direito social e humano não parece ter conseguido, na prática dos profissionais de saúde, abalar a relação paternalista que coloca o doente numa situação de submissão face à dominância do poder/saber médico central ou periférico que o doente, nos termos de Parsons, deve acatar humildemente como “um bom doente”. É este papel de passividade e submissão do doente que nos propomos problematizar nos meandros dos direitos humanos/direitos sociais de cidadania como campo de construção social assente em práticas norteadas por direitos e deveres que, nos termos de Foucault, submetem os cidadãos a constrangimentos inerentes às relações de poder.
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Terapia com Radiações
Resumo:
X-ray fluoroscopy is essential in both diagnosis and medical intervention, although it may contribute to significant radiation doses to patients that have to be optimised and justified. Therefore, it is crucial to the patient to be exposed to the lowest achievable dose without compromising the image quality. The purpose of this study was to perform an analysis of the quality control measurements, particularly dose rates, contrast and spatial resolution of Portuguese fluoroscopy equipment and also to provide a contribution to the establishment of reference levels for the equipment performance parameters. Measurements carried out between 2007 and 2013 on 143 fluoroscopy equipment distributed by 34 nationwide health units were analysed. The measurements suggest that image quality and dose rates of Portuguese equipment are congruent with other studies, and in general, they are as per the Portuguese law. However, there is still a possibility of improvements intending optimisation at a national level.