988 resultados para Radial Diffuser


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a centrifugal compressor the flow around the diffuser is collected and led to the pipe system by a spiral-shaped volute. In this study a single-stage centrifugal compressor with three different volutes is investigated. The compressorwas first equipped with the original volute, the cross-section of which was a combination of a rectangle and semi-circle. Next a new volute with a fully circular cross-section was designed and manufactured. Finally, the circular volute wasmodified by rounding the tongue and smoothing the tongue area. The overall performance of the compressor as well as the static pressure distribution after the impeller and on the volute surface were measured. The flow entering the volute was measured using a three-hole Cobra-probe, and flow visualisations were carriedout in the exit cone of the volute. In addition, the radial force acting on theimpeller was measured using magnetic bearings. The complete compressor with thecircular volute (inlet pipe, full impeller, diffuser, volute and outlet pipe) was also modelled using computational fluid dynamics (CFD). A fully 3-D viscous flow was solved using a Navier-Stokes solver, Finflo, developed at Helsinki University of Technology. Chien's k-e model was used to take account of the turbulence. The differences observed in the performance of the different volutes were quite small. The biggest differences were at low speeds and high volume flows,i.e. when the flow entered the volute most radially. In this operating regime the efficiency of the compressor with the modified circular volute was about two percentage points higher than with the other volutes. Also, according to the Cobra-probe measurements and flow visualisations, the modified circular volute performed better than the other volutes in this operating area. The circumferential static pressure distribution in the volute showed increases at low flow, constant distribution at the design flow and decrease at high flow. The non-uniform static pressure distribution of the volute was transmitted backwards across the vaneless diffuser and observed at the impeller exit. At low volume flow a strong two-wave pattern developed into the static pressure distribution at the impeller exit due to the response of the impeller to the non-uniformity of pressure. The radial force of the impeller was the greatest at the choke limit, the smallest atthe design flow, and moderate at low flow. At low flow the force increase was quite mild, whereas the increase at high flow was rapid. Thus, the non-uniformityof pressure and the force related to it are strong especially at high flow. Theforce caused by the modified circular volute was weaker at choke and more symmetric as a function of the volume flow than the force caused by the other volutes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Se ha estudiado un rodal adulto (edad media = 139 años) de Pinus nigra ssp. salzmannii var. pyrenaica en el W de la comarca del Solsonès (Lérida). Se han medido y extraído testigos de madera de 97 árboles adultos, a partir de los cuales se han medido e interdatado 13.340 anillos anuales, construyendo una cronología de crecimientos que abarca desde 1818 a 1996. Se han analizado las relaciones entre diversos parámetros dendrométricos medidos y los crecimientos observados, encontrándose en general muy bajas correlaciones. Se han construido tres series medias de crecimiento (cronología media, estandarizada, y en función de la edad) a partir de las cuales se ha analizado la evolución del rodal. Se ha observado un prolongado período de ralentización y estancamiento del crecimiento que se mantiene cerca de ochenta años, seguido de una fuerte corta a la que la masa reacciona con un notable incremento del crecimiento radial en un momento en que la edad media era ya de 101 años.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tässä työssä selostetaan kuumalanka-anemometrin käyttö virtausmittauksissa. Kuumalanka-anemometrilla saadaan mitattua virtausnopeuden ja -suunnan lisäksi nopeusheilahteluja. Mittaustaajuus on tyypillisesti useita kymmeniä tuhansia mittauksia sekunnissa ja signaali on jatkuva. Nykytekniikalla pystytään helposti tallentamaan mittauslaitteistolta saatu viesti tietokoneelle ja muuntamaan se nopeudeksi. Hetkellisten nopeuksien avulla voidaan laskea turbulenttisen virtauksen ominaisuuksia, kuten turbulenssin intensiteetti ja spektri. Kuumalanka-anemometrissa lämmitetään sähköisesti ohutta lankaa, joka on mitattavassa virtauksessa. Langan sähköteho on suunnilleen yhtäsuuri kuin langasta konvektiolla siirtyvä lämpöteho. Tällöin on teoreettisesti mahdollista laskea virtausnopeus lämpötehosta lämmönsiirtokorrelaatioilla. Käytännössä laitteisto joudutaan kuitenkin erikseen kalibroimaan, mutta sähkötehon teoreettista riippuvuutta konvektiosta käytetään hyväksi. Kuumalangan lämmitettävä osuus on tyypillisesti halkaisijaltaan 5 µm ja pituudeltaan noin 1 mm. Sitä käytetään pääasiassa kaasuvirtausten mittaamiseen ja valtaosassa mittauksissa virtausaineena on ilma. Kuumalanka voi olla toteutettu kuumakalvotekniikalla, jossa halkaisijaltaan noin 50 - 70 µm paksuinen kuitu on päällystetty ohuella sähköä johtavalla kalvolla. Kuumakalvoanturin ei tarvitse olla muodoltaan sylinterimäinen, se voi olla mm. kartiomainen tai kiilamainen. Erikoispäällystetyllä kuumakalvoanturilla on mahdollista mitata myös nestevirtauksia. Mitattaessa kaasuvirtauksia kuumakalvon etuna on selvästi parempi kestävyys verrattuna kuumalankaan. Nimitystä kuumalanka-anemometri käytetään yleisesti molemmista anturityypeistä Tämän työn alussa käsitellään sylinterin yli tapahtuvaan virtaukseen liittyvää virtausmekaniikkaa ja lämmönsiirtoa. Anemometrin sähköinen osa, laitteisto ja sen kalibrointi käydään läpi. Langan suuntariippuvuuden laskentaan esitetään tarvittavat yhtälöt. Työssä esitellään kolme laitteistolla tehtyä perusmittausta: anturin kohtauskulman muuttaminen, pyörähdyssymmerisen suihkun nopeuskenttä ja tuulitunnelin rajakerros. Lisäksi esitellään yksi käytännöllinen ja vaativampi mittaus, jossa on mitattu nopeusprofiili radiaalikompressorin diffuusorin loppuosassa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To understand how tree growth has responded to recent climate warming, an understanding of the tree-climate-site complex is necessary. To achieve this, radial growth variability among 204 trees established before 1850 was studied in relation to both climatic and site factors. Seventeen forest stands were sampled in the Spanish Central Pyrenees. Three species were studied: Pinus uncinata, Abies alba, and Pinus sylvestris. For each tree, a ring-width residual chronology was built. All trees cross-dated well, indicating a common influence of the regional climate. For the 1952-1993 period, the radial growth of all species, especially P. uncinata, was positively correlated with warm Novembers during the year before ring formation and warm Mays of the year the annual ring formed. Differences in species-stand elevation modulated the growth-climate associations. Radial growth in P. uncinata at high elevation sites was reduced when May temperatures were colder and May precipitation more abundant. In the 20th century, two contrasting periods in radial growth were observed: one (1900-1949) with low frequency of narrow and wide rings, low mean annual sensitivity, and low common growth variation; and another (1950-1994) with the reverse characteristics. The increased variability in radial growth since the 1950s was observed for all species and sites, which suggests a climatic cause. The low shared variance among tree chronologies during the first half of the 20th century may result from a"relaxation" of the elevation gradient, allowing local site conditions to dominate macroclimatic influence. These temporal trends may be related to the recently reported increase of climatic variability and warmer conditions. This study emphasizes the need to carefully assess the relationships between radial growth and site conditions along ecological gradients to improve dendroclimatic reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Radial maze tasks have been used to assess optimal foraging and spatial abilities in rodents. The spatial performance was based on a capacity to rely on a configuration of local and distant cues. We adapted maze procedures assessing the relative weight of local cues and distant landmarks for arm choice in humans. NEW METHOD: The procedure allowed testing memory of places in four experimental setups: a fingertip texture-groove maze, a tactile screen maze, a virtual radial maze and a walking size maze. During training, the four reinforced positions remained fixed relative to local and distal cues. During subsequent conflict trials, these frameworks were made conflictive in the prediction of reward locations. RESULTS: Three experiments showed that the relative weight of local and distal relational cues is affected by different factors such as cues' nature, visual access to the environment, real vs. virtual environment, and gender. A fourth experiment illustrated how a walking maze can be used with people suffering intellectual disability. COMPARISON WITH EXISTING METHODS: In our procedure, long-term (reference) and short-term (working) memory can be assessed. It is the first radial task adapted to human that enables dissociating local and distal cues, to provides an indication as to their relative salience. Our mazes are moveable and easily used in limited spaces. Tasks are performed with realistic and spontaneous though controlled exploratory movements. CONCLUSION: Our tasks enabled highlighting the use of different strategies. In a clinical perspective, considering the use of compensatory strategies should orient towards adapted behavioural rehabilitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several guidelines recommend computed tomography scans for populations with high-risk for lung cancer. The number of individuals evaluated for peripheral pulmonary lesions (PPL) will probably increase, and with it non-surgical biopsies. Associating a guidance method with a target confirmation technique has been shown to achieve the highest diagnostic yield, but the utility of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance without a guide sheath has not been reported. METHODS: We conducted a retrospective analysis of bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy procedures for the investigation of PPL performed by experienced bronchoscopists with no specific previous training in this particular technique. Operator learning curves and radiological predictors were assessed for all consecutive patients examined during the first year of application of the technique. RESULTS: Fifty-one PPL were investigated. Diagnostic yield and visualization yield were 72.5 and 82.3% respectively. The diagnostic yield was 64.0% for PPL ≤20mm, and 80.8% for PPL>20mm. No false-positive results were recorded. The learning curve of all diagnostic tools showed a DY of 72.7% for the first sub-group of patients, 81.8% for the second, 72.7% for the third, and 81.8% for the last. CONCLUSION: Bronchoscopy with radial probe endobronchial ultrasound using fluoroscopy as guidance is safe and simple to perform, even without specific prior training, and diagnostic yield is high for PPL>and ≤20mm. Based on these findings, this method could be introduced as a first-line procedure for the investigation of PPL, particularly in centers with limited resources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Estudar, retrospectivamente, as várias formas de apresentação da cicatriz radial/lesão esclerosante complexa (CR/LEC) na mamografia, correlacionando-as com o exame clínico e os achados ultra-sonográficos. Os achados histopatológicos e a associação da CR/LEC com hiperplasia atípica e carcinoma são discutidos. MATERIAIS E MÉTODOS: Foi realizado estudo retrospectivo de 926 lesões impalpáveis em 901 pacientes submetidas a biópsia excisional após localização pré-cirúrgica, do arquivo do Centro de Diagnóstico por Imagem e do Hospital Santa Rita, Vitória, ES, no período de outubro de 1993 a dezembro de 2001, nas quais 57 pacientes tiveram diagnóstico histopatológico de CR/LEC. RESULTADOS: A idade variou de 31 a 84 anos (média de 49 anos). As lesões foram palpáveis em dez casos. Na mamografia, 48 casos se apresentaram como distorção arquitetural, e com a mesma freqüência o nódulo espiculado e a densidade assimétrica, quatro casos cada. As microcalcificações foram detectadas na mamografia em 14 casos e em 20 quando o espécime cirúrgico foi avaliado. A ultra-sonografia foi realizada em 51 casos, tendo expressão em 17 como área hipoecóica irregular com atenuação acústica posterior. Houve 42 casos de CR/LEC sem ou com proliferação típica, nove casos com proliferação epitelial atípica e seis casos com carcinoma infiltrativo associado. CONCLUSÃO: Não é possível fazer diagnóstico diferencial de CR/LEC com câncer pelos métodos de imagem e a biópsia excisional deve ser realizada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The aims of the study are to compare the outcome with and without major bleeding and to identify the independent correlates of major bleeding complications and mortality in patients described in the ATOLL study. METHODS: The ATOLL study included 910 patients randomly assigned to either 0.5 mg/kg intravenous enoxaparin or unfractionated heparin before primary percutaneous coronary intervention. Incidence of major bleeding and ischemic end points was assessed at 1 month, and mortality, at 1 and 6 months. Patients with and without major bleeding complication were compared. A multivariate model of bleeding complications at 1 month and mortality at 6 months was realized. Intention-to-treat and per-protocol analyses were performed. RESULTS: The most frequent bleeding site appears to be the gastrointestinal tract. Age >75 years, cardiac arrest, and the use of insulin or >1 heparin emerged as independent correlates of major bleeding at 1 month. Patients presenting with major bleeding had significantly higher rates of adverse ischemic complications. Mortality at 6 months was higher in bleeders. Major bleeding was found to be one of the independent correlates of 6-month mortality. The addition or mixing of several anticoagulant drugs was an independent factor of major bleeding despite the predominant use of radial access. CONCLUSIONS: This study shows that major bleeding is independently associated with poor outcome, increasing ischemic events, and mortality in primary percutaneous coronary intervention performed mostly with radial access.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravascular brachytherapy with beta sources has become a useful technique to prevent restenosis after cardiovascular intervention. In particular, the Beta-Cath high-dose-rate system, manufactured by Novoste Corporation, is a commercially available 90Sr 90Y source for intravascular brachytherapy that is achieving widespread use. Its dosimetric characterization has attracted considerable attention in recent years. Unfortunately, the short ranges of the emitted beta particles and the associated large dose gradients make experimental measurements particularly difficult. This circumstance has motivated the appearance of a number of papers addressing the characterization of this source by means of Monte Carlo simulation techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a massless fluid (density = 0), the steady flow along a duct is governed exclusively by viscous losses. In this paper, we show that the velocity profile obtained in this limit can be used to calculate the pressure drop up to the first order in density. This method has been applied to the particular case of a duct, defined by two plane-parallel discs. For this case, the first-order approximation results in a simple analytical solution which has been favorably checked against numerical simulations. Finally, an experiment has been carried out with water flowing between the discs. The experimental results show good agreement with the approximate solution

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The radial displacement of a fluid annulus in a rotating circular HeleShaw cell has been investigated experimentally. It has been found that the flow depends sensitively on the wetting conditions at the outer interface. Displacements in a prewet cell are well described by Darcy"s law in a wide range of experimental parameters, with little influence of capillary effects. In a dry cell, however, a more careful analysis of the interfacemotion is required; the interplay between a gradual loss of fluid at the inner interface, and the dependence of capillary forces at the outer interface on interfacial velocity and dynamic contact angle, result in a constant velocity for the interfaces. The experimental results in this case correlate in the form of an empirical scaling relation between the capillary number Ca and a dimensionless group, related to the ratio of centrifugal to capillary forces, which spans about three orders of magnitude in both quantities. Finally, the relative thickness of the coating film left by the inner interface is obtained as a function of Ca.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Centrifugal compressors are widely used for example in refrigeration processes, the oil and gas industry, superchargers, and waste water treatment. In this work, five different vaneless diffusers and six different vaned diffusers are investigated numerically. The vaneless diffusers vary only by their diffuser width, so that four of the geometries have pinch implemented to them. Pinch means a decrease in the diffuser width. Four of the vaned diffusers have the same vane turning angle and a different number of vanes, and two have different vane turning angles. The flow solver used to solve the flow fields is Finflo, which is a Navier-Stokes solver. All the cases are modeled with the Chien's k – έ- turbulence model, and selected cases are modeled also with the k – ώ-SST turbulence model. All five vaneless diffusers and three vaned diffusers are investigated also experimentally. For each construction, the compressor operating map is measured according to relevant standards. In addition to this, the flow fields before and after the diffuser are measured with static and total pressure, flow angle and total temperature measurements. When comparing the computational results to the measured results, it is evident that the k – ώ-SST turbulence model predicts the flow fields better. The simulation results indicate that it is possible to improve the efficiency with the pinch, and according to the numerical results, the two best geometries are the ones with most pinch at the shroud. These geometries have approximately 4 percentage points higher efficiency than the unpinched vaneless diffusers. The hub pinch does not seem to have any major benefits. In general, the pinches make the flow fields before and after the diffuser more uniform. The pinch also seems to improve the impeller efficiency. This is down to two reasons. The major reason is that the pinch decreases the size of slow flow and possible backflow region located near the shroud after the impeller. Secondly, the pinches decrease the flow velocity in the tip clearance, leading to a smaller tip leakage flow and therefore slightly better impeller efficiency. Also some of the vaned diffusers improve the efficiency, the increment being 1...3 percentage points, when compared to the vaneless unpinched geometry. The measurement results confirm that the pinch is beneficial to the performance of the compressor. The flow fields are more uniform with the pinched cases, and the slow flow regions are smaller. The peak efficiency is approximately 2 percentage points and the design point efficiency approximately 4 percentage points higher with the pinched geometries than with the un- pinched geometry. According to the measurements, the two best geometries are the ones with the most pinch at the shroud, the case with the pinch only at the shroud being slightly better of the two. The vaned diffusers also have better efficiency than the vaneless unpinched geometries. However, the pinched cases have even better efficiencies. The vaned diffusers narrow the operating range considerably, whilst the pinch has no significant effect on the operating range.