898 resultados para RIGHT TO DRINKING WATER


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwater represents the most important raw material. Germany struggles to maintain the best water quality possible by providing advanced monitoring systems and legal measures to prevent further pollution. In areas involved in the intensive growing of plantations, one of the major contamination factors derives from nitrate. The aim of this master thesis is the characterisation of the Water Protection Area of Bremen (Germany). Denitrification is a natural process, representing the best means of natural reduction of the hazardous nitrate ion, which is dangerous both for human health and for the development of eutrophication. The study has been possible thanks to the collaboration with the University of Bremen, the Geological Service of Bremen (GDfB) and Peter Spiedt (Water Supply Company of Bremen). It will be defined whether nitrate amounts in the groundwater still overcome the threshold legally imposed, and state if the denitrification process takes place, thanks to new samples collected in 2015 and their integration with historical data. Gas samples have been gathered to test them with the “N2/Ar method”, which is able to estimate the denitrification rate quantitatively. Analyses stated the effective occurrence of the reaction, nevertheless showing that it only affects the chemical of the deep aquifers and not shallow ones. Temporal trends concentrations of nitrate have shown that no real improvement took place in the past years. It will be commented that despite the denitrification being responsible for an efficacious lowering in the nitrate ion, it needs reactive materials to take place. Since the latter are finite elements, it is not an endless process. It is thus believed that is clearly necessary to adopt a better attitude in order to maintain the best chemical qualities possible in such an important area, providing drinking water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ensuring water is safe at source and point-of-use is important in areas of the world where drinking water is collected from communal supplies. This report describes a study in rural Mali to determine the appropriateness of assumptions common among development organizations that drinking water will remain safe at point-of-use if collected from a safe (improved) source. Water was collected from ten sources (borehole wells with hand pumps, and hand-dug wells) and forty-five households using water from each source type. Water quality was evaluated seasonally (quarterly) for levels of total coliform, E.coli, and turbidity. Microbial testing was done using the 3M Petrifilm™ method. Turbidity testing was done using a turbidity tube. Microbial testing results were analyzed using statistical tests including Kruskal-Wallis, Mann Whitney, and analysis of variance. Results show that water from hand pumps did not contain total coliform or E.coli and had turbidity under 5 NTUs, whereas water from dug wells had high levels of bacteria and turbidity. However water at point-of-use (household) from hand pumps showed microbial contamination - at times being indistinguishable from households using dug wells - indicating a decline in water quality from source to point-of-use. Chemical treatment at point-of-use is suggested as an appropriate solution to eliminating any post-source contamination. Additionally, it is recommended that future work be done to modify existing water development strategies to consider water quality at point-of-use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two of the indicators of the UN Millennium Development Goals ensuring environmental sustainability are energy use and per capita carbon dioxide emissions. The increasing urbanization and increasing world population may require increased energy use in order to transport enough safe drinking water to communities. In addition, the increase in water use would result in increased energy consumption, thereby resulting in increased green-house gas emissions that promote global climate change. The study of multiple Municipal Drinking Water Distribution Systems (MDWDSs) that relates various MDWDS aspects--system components and properties--to energy use is strongly desirable. The understanding of the relationship between system aspects and energy use aids in energy-efficient design. In this study, components of a MDWDS, and/or the characteristics associated with the component are termed as MDWDS aspects (hereafter--system aspects). There are many aspects of MDWDSs that affect the energy usage. Three system aspects (1) system-wide water demand, (2) storage tank parameters, and (3) pumping stations were analyzed in this study. The study involved seven MDWDSs to understand the relationship between the above-mentioned system aspects in relation with energy use. A MDWDSs model, EPANET 2.0, was utilized to analyze the seven systems. Six of the systems were real and one was a hypothetical system. The study presented here is unique in its statistical approach using seven municipal water distribution systems. The first system aspect studied was system-wide water demand. The analysis involved analyzing seven systems for the variation of water demand and its impact on energy use. To quantify the effects of water use reduction on energy use in a municipal water distribution system, the seven systems were modeled and the energy usage quantified for various amounts of water conservation. It was found that the effect of water conservation on energy use was linear for all seven systems and that all the average values of all the systems' energy use plotted on the same line with a high R 2 value. From this relationship, it can be ascertained that a 20% reduction in water demand results in approximately a 13% savings in energy use for all seven systems analyzed. This figure might hold true for many similar systems that are dominated by pumping and not gravity driven. The second system aspect analyzed was storage tank(s) parameters. Various tank parameters: (1) tank maximum water levels, (2) tank elevation, and (3) tank diameter were considered in this part of the study. MDWDSs use a significant amount of electrical energy for the pumping of water from low elevations (usually a source) to higher ones (usually storage tanks). The use of electrical energy has an effect on pollution emissions and, therefore, potential global climate change as well. Various values of these tank parameters were modeled on seven MDWDSs of various sizes using a network solver and the energy usage recorded. It was found that when averaged over all seven analyzed systems (1) the reduction of maximum tank water level by 50% results in a 2% energy reduction, (2) energy use for a change in tank elevation is system specific, and (2) a reduction of tank diameter of 50% results in approximately a 7% energy savings. The third system aspect analyzed in this study was pumping station parameters. A pumping station consists of one or more pumps. The seven systems were analyzed to understand the effect of the variation of pump horsepower and the number of booster stations on energy use. It was found that adding booster stations could save energy depending upon the system characteristics. For systems with flat topography, a single main pumping station was found to use less energy. In systems with a higher-elevation neighborhood, however, one or more booster pumps with a reduced main pumping station capacity used less energy. The energy savings for the seven systems was dependent on the number of boosters and ranged from 5% to 66% for the analyzed five systems with higher elevation neighborhoods (S3, S4, S5, S6, and S7). No energy savings was realized for the remaining two flat topography systems, S1, and S2. The present study analyzed and established the relationship between various system aspects and energy use in seven MDWDSs. This aids in estimating the amount of energy savings in MDWDSs. This energy savings would ultimately help reduce Greenhouse gases (GHGs) emissions including per capita CO 2 emissions thereby potentially lowering the global climate change effect. This will in turn contribute to meeting the MDG of ensuring environmental sustainability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As continued global funding and coordination are allocated toward the improvement of access to safe sources of drinking water, alternative solutions may be necessary to expand implementation to remote communities. This report evaluates two technologies used in a small water distribution system in a mountainous region of Panama; solar powered pumping and flow-reducing discs. The two parts of the system function independently, but were both chosen for their ability to mitigate unique issues in the community. The design program NeatWork and flow-reducing discs were evaluated because they are tools taught to Peace Corps Volunteers in Panama. Even when ample water is available, mountainous terrains affect the pressure available throughout a water distribution system. Since the static head in the system only varies with the height of water in the tank, frictional losses from pipes and fittings must be exploited to balance out the inequalities caused by the uneven terrain. Reducing the maximum allowable flow to connections through the installation of flow-reducing discs can help to retain enough residual pressure in the main distribution lines to provide reliable service to all connections. NeatWork was calibrated to measured flow rates by changing the orifice coefficient (θ), resulting in a value of 0.68, which is 10-15% higher than typical values for manufactured flow-reducing discs. NeatWork was used to model various system configurations to determine if a single-sized flow-reducing disc could provide equitable flow rates throughout an entire system. There is a strong correlation between the optimum single-sized flow- reducing disc and the average elevation change throughout a water distribution system; the larger the elevation change across the system, the smaller the recommended uniform orifice size. Renewable energy can jump the infrastructure gap and provide basic services at a fraction of the cost and time required to install transmission lines. Methods for the assessment of solar powered pumping systems as a means for rural water supply are presented and assessed. It was determined that manufacturer provided product specifications can be used to appropriately design a solar pumping system, but care must be taken to ensure that sufficient water can be provided to the system despite variations in solar intensity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Membrane filtration has become an accepted technology for the removal of pathogens from drinking water. Viruses, known to contaminate water supplies, are too small to be removed by a size-exclusion mechanism without a large energy penalty. Thus, functionalized electrospun membranes that can adsorb viruses have drawn our interest. We chose a quaternized chitosan derivative (HTCC) which carries a positively-charged quaternary amine, known to bind negatively-charged virus particles, as a functionalized membrane material. The technique of electrospinning was utilized to produce nanofiber mats with large pore diameters to increase water flux and decrease membrane fouling. In this study, stable, functionalized, electrospun HTCC-PVA nanofibers that can remove 3.6 logs (99.97%) of a model virus, porcine parvovirus (PPV), from water by adsorption and filtration have been successfully produced. This technology has the potential to purify drinking water in undeveloped countries and reduce the number of deaths due to lack of sanitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwater age is a key aspect of production well vulnerability. Public drinking water supply wells typically have long screens and are expected to produce a mixture of groundwater ages. The groundwater age distributions of seven production wells of the Holten well field (Netherlands) were estimated from tritium-helium (3H/3He), krypton-85 (85Kr), and argon-39 (39Ar), using a new application of a discrete age distribution model and existing mathematical models, by minimizing the uncertainty-weighted squared differences of modeled and measured tracer concentrations. The observed tracer concentrations fitted well to a 4-bin discrete age distribution model or a dispersion model with a fraction of old groundwater. Our results show that more than 75 of the water pumped by four shallow production wells has a groundwater age of less than 20 years and these wells are very vulnerable to recent surface contamination. More than 50 of the water pumped by three deep production wells is older than 60 years. 3H/3He samples from short screened monitoring wells surrounding the well field constrained the age stratification in the aquifer. The discrepancy between the age stratification with depth and the groundwater age distribution of the production wells showed that the well field preferentially pumps from the shallow part of the aquifer. The discrete groundwater age distribution model appears to be a suitable approach in settings where the shape of the age distribution cannot be assumed to follow a simple mathematical model, such as a production well field where wells compete for capture area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A cross-sectional study on the use of three pesticides and their presence in drinking water sources was conducted in Githunguri/Kiaria community between January 1994-March 1995. The main objective of the study was to determine the extent to which some of the pesticides used by the Githunguri/Kiaria agricultural community were polluting their drinking water sources. Due to monetary and physical limitations, only DDT, its isomers and metabolites, carbofuran and carbaryl pesticides were identified and used as surrogates of pollution for the other pesticides.^ The study area was divided into high and low lying geographic surface areas. Thirty-four and 38 water sampling sites were randomly selected respectively. During wet and dry seasons, a total of 144 water samples were collected and analyzed at the Kenya Bureau of Standards Laboratory in Nairobi. Gas chromatography was used to analyze samples for possible presence of DDT, its isomers and metabolites, while high pressure liquid chromatography was used to analyze samples for carbofuran and carbaryl pesticides.^ Six sites testing positively for DDT, its isomers and metabolites represented 19.4% of the total sampled sites, with a mean concentration of 0.00310 ppb in the dry season and 0.0130 ppb in the wet season. All the six sites testing positively for the same pesticide exceeded the European maximum contaminant limit (MCL) in the wet season, and only one site exceeded the European MCL in the dry season.^ Those sites testing positively for carbofuran and carbaryl represented 5.6% of the total sampled sites. The mean concentration for the carbofuran at the sites was 2.500 ppb and 1.590 ppb in the dry and wet seasons respectively. Similarly, the mean concentration for carbaryl at the sites was 0.281 ppb in the dry season and 0.326 ppb in the wet season.^ One site testing positively for carbofuran exceeded the European MCL and WHO set limit in the wet season, while one site testing positively for the same pesticide exceeded the USA, Canada, European and WHO MCLs in the dry season. Similarly, one site which tested positively for carbaryl pesticide exceeded the European MCL in both seasons.^ Out of the 2,587 community members in the study area, 333 (13%) were exposed through their drinking water sources to the three pesticides investigated by this study. As a public health measure, integrated pest management approaches (IPM), protection of the wells and education of the community is necessary to minimize the pollution of the environment and safeguard the drinking water sources from pollution by the pesticides. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new technique for the detection of microbiological fecal pollution in drinking and in raw surface water has been modified and tested against the standard multiple-tube fermentation technique (most-probable-number, MPN). The performance of the new test in detecting fecal pollution in drinking water has been tested at different incubation temperatures. The basis for the new test was the detection of hydrogen sulfide produced by the hydrogen sulfide producing bacteria which are usually associated with the coliform group. The positive results are indicated by the appearance of a brown to black color in the contents of the fermentation tube within 18 to 24 hours of incubation at 35 (+OR-) .5(DEGREES)C. For this study 158 water samples of different sources have been used. The results were analyzed statistically with the paired t-test and the one-way analysis of variance. No statistically significant difference was noticed between the two methods, when tested 35 (+OR-) .5(DEGREES)C, in detecting fecal pollution in drinking water. The new test showed more positive results with raw surface water, which could be due to the presence of hydrogen sulfide producing bacteria of non-fecal origin like Desulfovibrio and Desulfomaculum. The survival of the hydrogen sulfide producing bacteria and the coliforms was also tested over a 7-day period, and the results showed no significant difference. The two methods showed no significant difference when used to detect fecal pollution at a very low coliform density. The results showed that the new test is mostly effective, in detecting fecal pollution in drinking water, when used at 35 (+OR-) .5(DEGREES)C. The new test is effective, simple, and less expensive when used to detect fecal pollution in drinking water and raw surface water at 35 (+OR-) .5(DEGREES)C. The method can be used for qualitative and/or quantitative analysis of water in the field and in the laboratory. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Drinking water-related exposures within populations living in the United States-Mexico border region, particularly among Hispanics, is an area that is largely unknown. Specifically, perceptions that may affect water source selection is an issue that has not been fully addressed. This study evaluates drinking water quality perceptions in a mostly Hispanic community living along the United States-Mexico border, a community also facing water scarcity issues. Using a survey that was administered during two seasons (winter and summer), data were collected from a total of 608 participants, of which 303 were living in the United States and 305 in Mexico. A (random) convenience sampling technique was used to select households and those interviewed were over 18 years of age. Statistically significant differences were observed involving country of residence (p=0.002). Specifically, those living in Mexico reported a higher use of bottled water than those living in the United States. Perception factors, especially taste, were cited as main reasons for not selecting unfiltered tap water as a primary drinking water source. Understanding what influences drinking water source preference can aid in the development of risk communication strategies regarding water quality. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Houston, Texas, once obtained all its drinking water from underground sources. However, in 1853, the city began supplementing its water from the surface source Lake Houston. This created differences in the exposure to disinfection byproducts (DBPs) in different parts of Houston. Trihalomethanes (THMs) are the most common DBP and are useful indicators of DBPs in treated drinking water. This study examines the relationship between THMs in chlorinated drinking water and the incidence of bladder cancer in Houston. ^ Methods. Individual bladder cancer deaths, from 1975 to 2004, were assigned to four surface water exposure areas in Houston utilizing census tracts—area A used groundwater the longest, area B used treated lake water the longest, area C used treated lake water the second longest, and area D used a combination of groundwater and treated lake water. Within each surface water exposure area mortality rates were calculated in 5 year intervals by four race-gender categories. Linear regression models were fitted to the bladder cancer mortality rates over the entire period of available data (1990–2004). ^ Results. A decrease in bladder cancer mortality was observed amongst white males in area B (p = 0.030), white females in area A (p = 0.008), non-white males in area D (p = 0.003), and non-white females in areas A and B (p = 0.002 & 0.001). Bladder cancer mortality differed by race-gender and time (p ≤ 0.001 & p ≤ 0.001), but not by surface water exposure area (p = 0.876). ^ Conclusion. The relationship between bladder cancer mortality and the four surface water exposure areas (signifying THM exposure) was insignificant. This result could be attributable to Houston controlling for THMs starting in the early 1980’s by using chloramine as a secondary disinfectant in the drinking water purification process.^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trihalomethanes are organic compounds formed in drinking water distribution systems as a result of disinfection. This capstone project researched and evaluated the statistical correlation of trihalomethanes in finished drinking water and total organic carbon in source water using data generated by Denver area utilities. Results of the study conclude that some drinking water supply systems show a slight correlation between source water total organic carbon levels and trihalomethane levels in finished water. Results of the study also verify the assertion that changes to treatment for the reduction of trihalomethanes, for the protection of human health under the Safe Drinking Water Act should be determined by each utility, using information from gathered data, seasonal trends, and small scale batch testing.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Six Denver metro water reservoirs were sampled to see what types of algae were found, and what impact the algae would have on drinking water reservoirs in the event of a bloom caused by warming water temperatures. Each sample contained algae. Toxic cyanobacteria, filamentous green algae, and different species of diatoms were found in the samples. Current climate change models show the temperature along the Front Range is rising and will continue to rise. With an increase in climate change and an increase in population, humans and animals will be at a greater risk of ingesting or coming into contact with toxic algae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Water quantity and quality issues worldwide are causing nations to consider alternate sources for drinking water. Desalination and other membrane processes for treatment of seawater and brackish inland waters have been in use for the past quarter century and are growing in use worldwide. These treatment processes create a highly concentrated waste stream in which the principal constituents are dissolved solids. This report provides an overview of desalination methods and the methods available to dispose of this waste stream. Innovative technologies being studied for possible future use are also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Grant No. R804292010."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Grant number R803986."