992 resultados para Professor Neil W. Archbold


Relevância:

100.00% 100.00%

Publicador:

Resumo:

 An exploration of the chemiluminescence from reactions of a large number of benzyl and phenylpiperazine analytes with tris(2,2’-bipyridyl)ruthenium(III) was carried out providing information towards the emission intensity of this chemiluminescent reagent and the structure of analytes it interacts with.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to discover phytochemicals that are potentially bioactive against Phytophthora cinnamomi, (a soil-borne plant pathogen) a metabolite profiling protocol for investigation of metabolic changes in Lupinus angustifolius L. plant roots in response to pathogen challenge has been established. Analysis of the metabolic profiles from healthy and P. cinnamomi-inoculated root tissue with high resolution mass spectrometry and nuclear magnetic resonance spectroscopy confirmed that although susceptible, L. angustifolius upregulated a defence associated genistein and 2′-hydroxygenistein-based isoflavonoid and a soyasapogenol saponin at 12h post inoculation which increased in concentration at 72h post inoculation. In contrast to the typical susceptible interaction, the application of a phosphorous-based treatment to L. angustifolius foliage 48h before P. cinnamomi challenge negated the ability of the pathogen to colonise the root tissue and cause disease. Importantly, although the root profiles of water-treated and phosphite-treated plants post pathogen inoculation contained the same secondary metabolites, concentration variations were observed. Accumulation of secondary metabolites within the P. cinnamomi-inoculated plants confirms that pathogen ingress of the root interstitially occurs in phosphite-treated plants, confirming a direct mode of action against the pathogen upon breaching the root cells.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Twomultidimensional HPLC separations of an Australian red wine are presented, >70% of the available separation space was used. A porous graphitic carbon (PGC) stationary phase was used as the first dimension in both separations with both RP core–shell and hydrophilic interaction chromatography fully porous columns used separately in the second dimension. To overcome peak analysis problems caused by signal noise and low detection limits, the data were pre-processed with penalised least-squares smoothing. The PGC × RP combination separated 85 peaks with a spreading angle of 71 and the PGC × hydrophilic interaction chromatography separated 207 peaks with a spreading angle of 80. Both 2D-HPLC steps were completed in 76 min using a comprehensive stop-and-go approach. A smoothing step was added to peak-picking processes and was able to greatly reduce the number of false peaks present due to noise in the chromatograms. The required thresholds were not able to ignore the noise because of the small magnitude of the peaks; 1874 peaks were located in the non-smoothed PGC × RP separation that reduced to 227 peaks after smoothing was included.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To achieve the greatest peak capacity in two-dimensional high performance liquid chromatography (2D-HPLC) a gradient should be operated in both separation dimensions. However, it is known that when an injection solvent that is stronger than the initial mobile phase composition is deleterious to peak performance, thus causing problems when cutting a portion from one gradient into another. This was overcome when coupling hydrophilic interaction with reversed phase chromatography by introducing a counter gradient that changed the solvent strength of the second dimension injection. It was found that an injection solvent composition of 20% acetonitrile in water gave acceptable results in one-dimensional simulations with an initial composition of 5% acetonitrile. When this was transferred to a 2D-HPLC separation of standards it was found that a marked improvement in peak shape was gained for the moderately retained analytes (phenol and dimethyl phthalate), some improvement for the weakly retained caffeine and very little change for the strongly retained n-propylbenzene and anthracene which already displayed good chromatographic profiles. This effect was transferred when applied to a 2D-HPLC separation of a coffee extract where the indecipherable retention profile was transformed to a successful application multidimensional chromatography with peaks occupying 71% of the separation space according to the geometric approach to factor analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High-performance liquid chromatography with chemiluminescence detection based on the reaction with acidic potassium permanganate and formaldehyde was explored for the determination of neurotransmitters and their metabolites. The neurotransmitters norepinephrine and dopamine were quantified in the left and right hemispheres of rat hippocampus, nucleus accumbens and prefrontal cortex, and the metabolites vanillylmandelic acid, 3,4-dihydrophenylacetic acid, 5-hydroxyindole-3-acetic acid and homovanillic acid were identified in human urine. Under optimised chemiluminescence reagent conditions, the limits of detection for these analytes ranged from 2.5 × 10−8 to 2.5 × 10−7 M. For the determination of neurotransmitter metabolites in urine, a two-dimensional high-performance liquid chromatography (2D-HPLC) separation operated in heart-cutting mode was developed to overcome the peak capacity limitations of the one-dimensional separation. This approach provided the greater separation power of 2D-HPLC with analysis times comparable to conventional one-dimensional separations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthesis and chromatographic behavior of an analytical size mixed-mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed-mode column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnesium alloy ZE41 (Mg-Zn-RE-Zr), which is used extensively in the aerospace industry, possesses excellent mechanical properties albeit poor corrosion resistance. This work investigates the mechanism of corrosion, and the interaction between the grain boundary intermetallic phases, the zirconium (Zr)-rich regions within the grains and the bulk Mg rich matrix in both the as-cast and heat-treated conditions. The results of optical and scanning electron microscopy (SEM) show the importance of the microstructure in the initiation and propagation of corrosion in an aqueous environment. The Zr-rich regions play a distinct role in the early stages of corrosion with this alloy. The second part of this work investigates the interaction of two different ionic liquids (ILs) with the surface of the ZE41 alloy. ILs based on trihexyltetradecylphosphonium (P 6,6,6,14) coupled with either diphenylphosphate (DPP) or bis(trifluoromethanesulfonyl) amide (Tf 2N) have been shown to react with Mg alloy surfaces, leading to the formation of a surface film that can improve the corrosion resistance of the alloy. The interaction of the ILs with the ZE41 surface has been investigated by optical microscopy and SEM. Surface characterization has been performed using Time of Flight-Secondary Ion Mass Spectrometry (ToF-SIMS) and X-ray Photoelectron Spectroscopy (XPS). The surface characterization and microscopy revealed the preferential interaction with the grain boundaries and grain boundary phases. Thus the morphology and microstructure of the Mg surface seems critical in determining the nature of the interaction with the IL. The corrosion protection of the IL films formed on the ZE41 surface was investigated by SEM and potentiodynamic polarisation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The chemiluminescence from four cyclometalated iridium(III) complexes containing an ancillary bathophenanthroline-disulfonate ligand exhibited a wide range of emission colours (green to red), and in some cases intensities that are far greater than the commonly employed benchmark reagent, [Ru(bpy)3](2+). A similar complex incorporating a sulfonated triazolylpyridine-based ligand enabled the emission to be shifted into the blue region of the spectrum, but the responses with this complex were relatively poor. DFT calculations of electronic structure and emission spectra support the experimental findings.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acidic potassium permanganate chemiluminescence enables direct post-column detection of glutathione, but its application to assess the redox state of a wider range of biological fluids and tissues is limited by its sensitivity. Herein we show that the simple on-line addition of an aqueous formaldehyde solution not only enhances the sensitivity of the procedure by two orders of magnitude, but also provides a remarkable improvement in the selectivity of the reagent towards thiols such as glutathione (compared to phenols and amino acids that do not possess a thiol group). This enhanced mode of detection was applied to the determination of glutathione and its corresponding disulfide species in homogenised striatum samples taken from both wild type mice and the R6/1 transgenic mouse model of Huntington's disease, at both 8 and 12 weeks of age. No significant difference was observed between the GSH/GSSG ratios of wild type mice and R6/1 mice at either age group, suggesting that the early disease progression had not significantly altered the intracellular redox environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The selection of two high performance liquid chromatography (HPLC) columns with vastly different retention mechanisms is vital for performing effective two-dimensional (2D-) HPLC. This paper reports on a systematic method to select a pair of HPLC columns that provide the most different separations for a given sample. This was completed with the aid of a HPLC simulator that predicted retention profiles on the basis of real experimental data, which is difficult when the contents of sample matrices are largely-or completely-unknown. Peaks from the same compounds must first be matched between chromatograms to compare the retention profiles and optimised 2D-HPLC column selection. In this work, two methods of matching peaks between chromatograms were explored and an optimal pair of chromatography columns was selected for 2D-HPLC. First, a series of 17 antioxidants were selected as an analogue for a coffee extract. The predicted orthogonality of the standards was 39%, according to the fractional surface coverage 'bins' method, which was close to the actual space utilisation of the standard mixture, 44%. Moreover, the orthogonality for the 2D-HPLC of coffee matched the predicted value of 38%. The second method employed a complex sample matrix of urine to optimise the column selections. Seven peaks were confidently matched between chromatograms by comparing relative peak areas of two detection strategies: UV absorbance and potassium permanganate chemiluminescence. It was found that the optimal combinations had an orthogonality of 35% while the actual value was closer to 30%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Widely known for its recreational use, the cannabis plant also has the potential to act as an antibacterial agent in the medicinal field. The analysis of cannabis plants/products in both pharmacological and forensic studies often requires the separation of compounds of interest and/or accurate identification of the whole cannabinoid profile. In order to provide a complete separation and detection of cannabinoids, a new two-dimensional liquid chromatography method has been developed using acidic potassium permanganate chemiluminescence detection, which has been shown to be selective for cannabinoids. This was carried out using a Luna 100 Å CN column and a Poroshell 120 EC-C18 column in the first and second dimensions, respectively. The method has utilized a large amount of the available separation space with a spreading angle of 48.4° and a correlation of 0.66 allowing the determination of more than 120 constituents and mass spectral identification of ten cannabinoids in a single analytical run. The method has the potential to improve research involved in the characterization of sensitive, complex matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper describes a non-destructive "peak parking" protocol in order to assess the axial heterogeneity of an in situ modified monolithic column for high performance liquid chromatography; a "gradient stationary phase" was designed whereby the ligand density decreases along the length of the rod in the "forward flow" configuration. The results of multi-location peak parking demonstrated a consistent increase in peak variance from the 1 cm position of the column to the 9 cm location. This increase in band broadening supported the theory of a decreasing ligand density along the length of this gradient column. This is consistent with efficiency measurements performed in both the forward and reverse flow directions, with an improved efficiency (15% increase in N m-1) in the reverse direction. These results are consistent with theoretical investigations into stationary phase gradients.