998 resultados para OPTIC RADIATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Personal ultraviolet dosimeters have been used in epidemiological studies to understand the risks and benefits of individuals' exposure to solar ultraviolet radiation (UVR). We investigated the types and determinants of non-compliance associated with a protocol for use of polysulphone UVR dosimeters. In the AusD Study, 1,002 Australian adults (aged 18-75 years) were asked to wear a new dosimeter on their wrist each day for 10 consecutive days to quantify their daily exposure to solar UVR. Of the 10,020 dosimeters distributed, 296 (3%) were not returned or used (Type I non-compliance) and other usage errors were reported for 763 (8%) returned dosimeters (Type II non-compliance). Type I errors were more common in participants with predominantly outdoor occupations. Type II errors were reported more frequently on the first day of measurement; weekend days or rainy days; and among females; younger people; more educated participants or those with outdoor occupations. Half (50%) the participants reported a non-compliance error on at least one day during the 10-day period. However, 92% of participants had at least 7 days of usable data without any apparent non-compliance issues. The factors identified should be considered when designing future UVR dosimetry studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Quantitative Assessment of Solar UV [ultraviolet] Exposure for Vitamin D Synthesis in Australian Adults (AusD) Study aimed to better define the relationship between sun exposure and serum 25-hydroxyvitamin D (25(OH)D) concentration. Cross-sectional data were collected between May 2009 and December 2010 from 1,002 participants aged 18-75 years in 4 Australian sites spanning 24° of latitude. Participants completed the following: 1) questionnaires on sun exposure, dietary vitamin D intake, and vitamin D supplementation; 2) 10 days of personal ultraviolet radiation dosimetry; 3) a sun exposure and physical activity diary; and 4) clinical measurements and blood collection for 25(OH)D determination. Our multiple regression model described 40% of the variance in 25(OH)D concentration; modifiable behavioral factors contributed 52% of the explained variance, and environmental and demographic or constitutional variables contributed 38% and 10%, respectively. The amount of skin exposed was the single strongest contributor to the explained variance (27%), followed by location (20%), season (17%), personal ultraviolet radiation exposure (8%), vitamin D supplementation (7%), body mass index (weight (kg)/height (m)2) (4%), and physical activity (4%). Modifiable behavioral factors strongly influence serum 25(OH)D concentrations in Australian adults. In addition, latitude was a strong determinant of the relative contribution of different behavioral factors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes a Matlab toolbox for parametric identification of fluid-memory models associated with the radiation forces ships and offshore structures. Radiation forces are a key component of force-to-motion models used in simulators, motion control designs, and also for initial performance evaluation of wave-energy converters. The software described provides tools for preparing non-parmatric data and for identification with automatic model-order detection. The identification problem is considered in the frequency domain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This contribution outlines Synchrotron-based X-ray micro-tomography and its potential use in structural geology and rock mechanics. The paper complements several recent reviews of X-ray microtomography. We summarize the general approach to data acquisition, post-processing as well as analysis and thereby aim to provide an entry point for the interested reader. The paper includes tables listing relevant beamlines, a list of all available imaging techniques, and available free and commercial software packages for data visualization and quantification. We highlight potential applications in a review of relevant literature including time-resolved experiments and digital rock physics. The paper concludes with a report on ongoing developments and upgrades at synchrotron facilities to frame the future possibilities for imaging sub-second processes in centimetre-sized samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamics describing the motion response of a marine structure in waves can be represented within a linear framework by the Cummins Equation. This equation contains a convolution term that represents the component of the radiation forces associated with fluid memory effects. Several methods have been proposed in the literature for the identification of parametric models to approximate and replace this convolution term. This replacement can facilitate the model implementation in simulators and the analysis of motion control designs. Some of the reported identification methods consider the problem in the time domain while other methods consider the problem in the frequency domain. This paper compares the application of these identification methods. The comparison is based not only on the quality of the estimated models, but also on the ease of implementation, ease of use, and the flexibility of the identification method to incorporate prior information related to the model being identified. To illustrate the main points arising from the comparison, a particular example based on the coupled vertical motion of a modern containership vessel is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Combining facets of health physics with medicine, An Introduction to Radiation Protection in Medicine covers the background of the subject and the medical situations where radiation is the tool to diagnose or treat human disease. Encouraging newcomers to the field to properly and efficiently function in a versatile and evolving work setting, it familiarizes them with the particular problems faced during the application of ionizing radiation in medicine. The text builds a fundamental knowledge base before providing practical descriptions of radiation safety in medicine. It covers basic issues related to radiation protection, including the physical science behind radiation protection and the radiobiological basis of radiation protection. The text also presents operational and managerial tools for organizing radiation safety in a medical workplace. Subsequent chapters form the core of the book, focusing on the practice of radiation protection in different medical disciplines. They explore a range of individual uses of ionizing radiation in various branches of medicine, including radiology, nuclear medicine, external beam radiotherapy, and brachytherapy. With contributions from experienced practicing physicists, this book provides essential information about dealing with radiation safety in the rapidly shifting and diverse environment of medicine."--publisher website

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of radiation on natural convection of Newtonian fluid contained in an open cavity is investigated in this study. The governing partial differential equations are solved numerically using the Alternate Direct Implicit method together with the Successive Over Relaxation method. The study is focused on studying the flow pattern and the convective and radiative heat transfer rates are studied for different values of radiation parameters namely, the optical thickness of the fluid, scattering albedo, and the Planck number. It was found that in the optically thin limit, an increase in the optical thickness of the fluid raises the temperature and radiation heat transfer of the fluid. However, a further increase in the optical thickness decreases the radiative heat transfer rate due to increase in the energy level of the fluid, which ultimately reduces the total heat transfer rate within the fluid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate the effects of a natural oil-based emulsion containing allantoin versus aqueous cream for preventing and managing radiation induced skin reactions (RISR). Methods and Materials A total of 174 patients were randomised and participated in the study. Patients either received Cream 1 (the natural oil-based emulsion containing allantoin) or Cream 2 (aqueous cream). Skin toxicity, pain, itching and skin-related quality of life scores were collected for up to four weeks after radiation treatment. Results Patients who received Cream 1 had a significantly lower average level of Common Toxicity Criteria at week 3 (p<0.05), but had statistically higher average levels of skin toxicity at weeks 7, 8 and 9 (all p<0.001). Similar results were observed when skin toxicity was analysed by grades. With regards to pain, patients in the Cream 2 group had a significantly higher average level of worst pain (p<0.05) and itching (p=0.046) compared to the Cream 1 group at week 3, however these differences were not observed at other weeks. In addition, there was a strong trend for Cream 2 to reduce the incidence of grade 2 or more skin toxicity in comparison to Cream 1 (p=0.056). Overall, more participants in the Cream 1 group were required to use another topical treatment at weeks 8 (p=0.049) and 9 (p=0.01). Conclusion The natural oil-based emulsion containing allantoin appears to have similar effects for managing skin toxicity compared to aqueous cream up to week 5, however, it becomes significantly less effective at later weeks into the radiation treatment and beyond treatment completion (week 6 and beyond). There were no major differences in pain, itching and skin-related quality of life. In light of these results, clinicians and patients can base their decision on costs and preferences. Overall, aqueous cream appears to be a more preferred option.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiosensitizing Effect of Electrochemotherapy in a Fractionated Radiation Regimen in Radiosensitive Murine Sarcoma and Radioresistant Adenocarcinoma Tumor Model. Electrochemotherapy can potentiate the radiosensitizing effect of bleomycin, as shown in our previous studies. To bring this treatment closer to use in clinical practice, we evaluated the interaction between electrochemotherapy with bleomycin and single-dose or fractionated radiation in two murine tumor models with different histology and radiosensitivity. Radiosensitive sarcoma SA-1 and radioresistant adenocarcinoma CaNT subcutaneous tumors grown in A/J and CBA mice, respectively, were used. The anti-tumor effect and skin damage around the treated tumors were evaluated after electrochemotherapy with bleomycin alone or combined with single-dose radiation or a fractionated radiation regimen. The anti-tumor effectiveness of electrochemotherapy was more pronounced in SA-1 than CaNT tumors. In both tumor models, the tumor response to radiation was not significantly influenced by bleomycin alone or by electroporation alone. However, electrochemotherapy before the first tumor irradiation potentiated the response to a single-dose or fractionated radiation regimen in both tumors. For the fractionated radiation regimen, normal skin around the treated tumors was damaged fourfold less than for the single-dose regimen. Electrochemotherapy prior to single-dose irradiation induced more damage to the skin around the treated tumors and greater loss of body weight compared to other irradiated groups, whereas electrochemotherapy combined with the fractionated radiation regimen did not. Electrochemotherapy with low doses of bleomycin can also be used safely for radiosensitization of different types of tumors in a fractionated radiation regimen, resulting in a good anti-tumor effect and no major potentiating effect on radiation-induced skin damage. © 2009 by Radiation Research Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The present study aimed to evaluate the antitumor effectiveness of systemic interleukin (IL)-12 gene therapy in murine sarcoma models, and to evaluate its interaction with the irradiation of tumors and metastases. To avoid toxic side-effects of IL-12 gene therapy, the objective was to achieve the controlled release of IL-12 after intramuscular gene electrotransfer. Methods: Gene electrotransfer of the plasmid pORF-mIL12 was performed into the tibialis cranialis in A/J and C57BL/6 mice. Systemic release of the IL-12 was monitored in the serum of mice after carrying out two sets of intramuscular IL-12 gene electrotransfer of two different doses of plasmid DNA. The antitumor effectiveness of IL-12 gene electrotransfer alone or in combination with local tumor or lung irradiation with X-rays, was evaluated on subcutaneous SA-1 and LPB tumors, as well as on lung metastases. Results: A synergistic antitumor effect of intramuscular gene electrotransfer combined with local tumor irradiation was observed as a result of the systemic distribution of IL-12. The gene electrotransfer resulted in up to 28% of complete responses of tumors. In combination with local tumor irradiation, the curability was increased by up to 100%. The same effect was observed for lung metastases, where a potentiating factor of 1.3-fold was determined. The amount of circulating IL-12 was controlled by the number of repeats of gene electrotransfer and by the amount of the injected plasmid. Conclusions: The present study demonstrates the feasibility of treatment by IL-12 gene electrotransfer combined with local tumor or lung metastases irradiation on sarcoma tumors for translation into the clinical setting. Copyright © 2009 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM) and the soft tissue prostate (CBCTST). Methods Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland–Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST. Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM. Results CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of −4.9 to 2.6, −1.6 to 2.5 and −4.7 to 1.9 mm in the superior–inferior, left–right and anterior–posterior planes, respectively. Conclusions Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose An emerging developmental tool to help radiation therapists achieve better outcomes is 'peer review'. This review of the current literature summarises the challenges and benefits of peer review in both individual and departmental practice. Discussion There is compelling evidence supporting peer review implementation at both individual and department level in many professions. Implementing peer review requires that radiation therapists and other radiation oncology professionals embrace a culture that supports safety. Peer review can identify trends and barriers associated with quality radiotherapy and share best practice or recommend changes accordingly. Support for peer review must come from pre-registration educational systems as well as clinical managers. Continuing professional development in the workplace is nurtured by peer review of radiotherapy practice and an aptitude for this should be viewed as important to the profession as technical and clinical skills. Conclusion It is clear that peer review has the potential to facilitate reflective practice, improve staff motivation and help foster a culture of quality and safety in radiation oncology. To drive the issues of quality and safety a step further radiation therapists need to accept the challenge of adopting peer review methods in day-to-day practice.

Relevância:

20.00% 20.00%

Publicador: