959 resultados para MEASURING METHODS


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Evidence-based practice (EBP) is embraced internationally as an ideal approach to improve patient outcomes and provide cost-effective care. However, despite the support for and apparent benefits of evidence-based practice, it has been shown to be complex and difficult to incorporate into the clinical setting. Research exploring implementation of evidence-based practice has highlighted many internal and external barriers including clinicians’ lack of knowledge and confidence to integrate EBP into their day-to-day work. Nurses in particular often feel ill-equipped with little confidence to find, appraise and implement evidence. Aims: The following study aimed to undertake preliminary testing of the psychometric properties of tools that measure nurses’ self-efficacy and outcome expectancy in regard to evidence-based practice. Methods: A survey design was utilised in which nurses who had either completed an EBP unit or were randomly selected from a major tertiary referral hospital in Brisbane, Australia were sent two newly developed tools: 1) Self-efficacy in Evidence-Based Practice (SE-EBP) scale and 2) Outcome Expectancy for Evidence-Based Practice (OE-EBP) scale. Results: Principal Axis Factoring found three factors with eigenvalues above one for the SE-EBP explaining 73% of the variance and one factor for the OE-EBP scale explaining 82% of the variance. Cronbach’s alpha for SE-EBP, three SE-EBP factors and OE-EBP were all >.91 suggesting some item redundancy. The SE-EBP was able to distinguish between those with no prior exposure to EBP and those who completed an introductory EBP unit. Conclusions: While further investigation of the validity of these tools is needed, preliminary testing indicates that the SE-EBP and OE-EBP scales are valid and reliable instruments for measuring health professionals’ confidence in the process and the outcomes of basing their practice on evidence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The overall aim of this project was to contribute to existing knowledge regarding methods for measuring characteristics of airborne nanoparticles and controlling occupational exposure to airborne nanoparticles, and to gather data on nanoparticle emission and transport in various workplaces. The scope of this study involved investigating the characteristics and behaviour of particles arising from the operation of six nanotechnology processes, subdivided into nine processes for measurement purposes. It did not include the toxicological evaluation of the aerosol and therefore, no direct conclusion was made regarding the health effects of exposure to these particles. Our research included real-time measurement of sub, and supermicrometre particle number and mass concentration, count median diameter, and alveolar deposited surface area using condensation particle counters, an optical particle counter, DustTrak photometer, scanning mobility particle sizer, and nanoparticle surface area monitor, respectively. Off-line particle analysis included scanning and transmission electron microscopy, energy-dispersive x-ray spectrometry, and thermal optical analysis of elemental carbon. Sources of fibrous and non-fibrous particles were included.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Understanding the impacts of traffic and climate change on water quality helps decision makers to develop better policy and plans for dealing with unsustainable urban and transport development. This chapter presents detailed methodologies developed for sample collection and testing for heavy metals and total petroleum hydrocarbons, as part of a research study to investigate the impacts of climate change and changes to urban traffic characteristics on pollutant build-up and wash-off from urban road surfaces. Cadmium, chromium, nickel, copper, lead, iron, aluminium, manganese and zinc were the target heavy metals, and selected gasoline and diesel range organics were the target total petroleum hydrocarbons for this study. The study sites were selected to encompass the urban traffic characteristics of the Gold Coast region, Australia. An improved sample collection method referred to as ‘the wet and dry vacuum system’ for the pollutant build-up, and an effective wash-off plan to incorporate predicted changes to rainfall characteristics due to climate change, were implemented. The novel approach to sample collection for pollutant build-up helped to maintain the integrity of collection efficiency. The wash-off plan helped to incorporate the predicted impacts of climate change in the Gold Coast region. The robust experimental methods developed will help in field sample collection and chemical testing of different stormwater pollutants in build-up and wash-off.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The prevalence of refractive errors in children has been extensively researched. Comparisons between studies can, however, be compromised because of differences between accommodation control methods and techniques used for measuring refractive error. The aim of this study was to compare spherical refractive error results obtained at baseline and using two different accommodation control methods – extended optical fogging and cycloplegia, for two measurement techniques – autorefraction and retinoscopy. Methods: Participants comprised twenty-five school children aged between 6 and 13 years (mean age: 9.52 ± 2.06 years). The refractive error of one eye was measured at baseline and again under two different accommodation control conditions: extended optical fogging (+2.00DS for 20 minutes) and cycloplegia (1% cyclopentolate). Autorefraction and retinoscopy were both used to measure most plus spherical power for each condition. Results: A significant interaction was demonstrated between measurement technique and accommodation control method (p = 0.036), with significant differences in spherical power evident between accommodation control methods for each of the measurement techniques (p < 0.005). For retinoscopy, refractive errors were significantly more positive for cycloplegia compared to optical fogging, which were in turn significantly more positive than baseline, while for autorefraction, there were significant differences between cycloplegia and extended optical fogging and between cycloplegia and baseline only. Conclusions: Determination of refractive error under cycloplegia elicits more plus than using extended optical fogging as a method to relax accommodation. These findings support the use of cycloplegic refraction compared with extended optical fogging as a means of controlling accommodation for population based refractive error studies in children.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nutrients balance such as nitrogen and phosphorus balance are increasingly used as an indicator of the environmental performance of agricultural sector in international and global context. However there still is a lack of harmony in the use of methods for estimating the nutrients balance among countries. This is because of the disagreement regarding the accuracy and uncertainty of different accounting methods. The lack of harmony in the methods used in different countries further increases the uncertainty in the context of the international comparisons. This paper provides a new framework for nutrients balance calculation using the farm-gate accounting method. The calculation under this new framework takes advantage of availability of data from FAO and other reliable national and international sources. Due to this, the proposed framework is highly adaptable in many countries, making the global comparison feasible. The paper also proposes three criteria including adaptability, accuracy and interpretability to assess the appropriateness of nutrients accounting method. Based on these criteria, the paper provides a comprehensive comparison of the farm-gate and soil-surface methods in accounting country-level nutrients balance of agricultural production. The paper identifies some shortcomings of the soil-surface balance and shows that the farm-gate method has a greater potential of providing a more accurate and meaningful estimation of national nutrients balance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The player experience is at the core of videogame play. Understanding the facets of player experience presents many research challenges, as the phenomenon sits at the intersection of psychology, design, human-computer interaction, sociology, and physiology. This workshop brings together an interdisciplinary group of researchers to systematically and rigorously analyse all aspects of the player experience. Methods and tools for conceptualising, operationalising and measuring the player experience form the core of this research. Our aim is to take a holistic approach to identifying, adapting and extending theories and models of the player experience, to understand how these theories and models interact, overlap and differ, and to construct a unified vision for future research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Understanding the mechanical properties of tendon is an important step to guiding the process of improving athletic performance, predicting injury and treating tendinopathies. The speed of sound in a medium is governed by the bulk modulus and density for fluids and isotropic materials. However, for tendon,which is a structural composite of fluid and collagen, there is some anisotropy requiring an adjustment for Poisson’s ratio. In this paper, these relationships are explored and modelled using data collected, in vivo, on human Achilles tendon. Estimates for elastic modulus and hysteresis based on speed of sound data are then compared against published values from in vitro mechanical tests. Methods: Measurements using clinical ultrasound imaging, inverse dynamics and acoustic transmission techniques were used to determine dimensions, loading conditions and longitudinal speed of sound for the Achilles tendon during a series of isometric plantar flexion exercises against body weight. Upper and lower bounds for speed of sound versus tensile stress in the tendon were then modelled and estimates derived for elastic modulus and hysteresis. Results: Axial speed of sound varied between 1850 to 2090 m.s−1 with a non-linear, asymptotic dependency on the level of tensile stress in the tendon 5–35 MPa. Estimates derived for the elastic modulus ranged between 1–2 GPa. Hysteresis derived from models of the stress-strain relationship, ranged from 3–11%. These values agree closely with those previously reported from direct measurements obtained via in vitro mechanical tensile tests on major weight bearing tendons. Discussion: There is sufficiently good agreement between these indirect (speed of sound derived) and direct (mechanical tensile test derived) measures of tendon mechanical properties to validate the use of this non-invasive acoustic transmission technique. This non-invasive method is suitable for monitoring changes in tendon properties as predictors of athletic performance, injury or therapeutic progression.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To estimate the burden of diseases in Shandong province by the means of DALY (Disability- adjusted life year) thus to investigate the key public health problems referencing for health policy making. Methods DALYs were calculated following the procedures developed for the Global Burden of Disease (GBD) study to ensure comparability. We measured YLLs using the mortality data of 19 Disease Surveillance Points (DSPs) in Shandong Province during 2000 and 2005. YLDs were estimated based on data for WPRO in the 2002 GBD study published by WHO. Results During this period, the average DALYs loss by all causes for the residents of DSPs in Shandong was 149.74 per thousand persons each year. Noncommunicable diseases accounted for 76.63% of the disability adjusted life years, communicable diseases and other disorders represented 14.13%, and injuries 9.24%. Nearly half of the DALYs (45%) happened among the elderly (60+). Malignant neoplasm was the number one cause of DALYs loss in the male, followed by neuropsychiatric disorder, injury, cerebrovascular disease, heart disease,etc. However, neuropsychiatric disorder possessed the largest single contributor to DALY in the female and followed by heart disease, malignant neoplasm, cerebrovascular disease and respiratory disease. Conclusion Non-communicable diseases such as circulatory diseases, neuropsychiatric disorders and malignant neoplasms were the main causes of disease burden in Shandong province. The importance of neuropsychiatric disorders was more striking and should be recognized properly. The lack of morbidity data is the main limitation of this study. Abstract in Chinese 目的 应用伤残调整寿命年测量山东省居民疾病负担,提出该地区主要卫生问题,为卫生决策提供科学依据. 方法 以山东省2000-2005年19个疾病监测点的死因监测资料为基础,利用世界卫生组织(WHO)提供的方法计算不同疾病在不同性别年龄人群所造成的伤残调整寿命年(DALYs),其中,YIJDs根据WHO公布的亚太区2002年疾病负担数据进行估算. 结果 2000-2005年山东省疾病监测系统居民因为早死和残疾年平均损失149.74个DALYs/千人,其中,76.6%的DALYs损失因慢性非传染性疾病所致,14.1%由传染性疾病等引起,9.2%因为意外伤害造成;接近1/2(45%)的DALYs损失发生在60岁以上人群;恶性肿瘤为造成男性居民DALYs损失的首位原因,其次为精神行为疾患、意外伤害、脑血管病和心脏病等,女性居民则以精神行为疾患为DALYs首位原因,其次为心脏病、恶性肿瘤、脑血管病和呼吸系统疾病. 结论 以循环系统疾病、精神行为疾惠和恶性肿瘤为首的慢性非传染性疾病为造成山东省疾病负担DALYs损失的主要原因.对于精神行为疾患的重要性的认识有待于进一步提高,研究的主要局限性在于发病率资料的缺乏.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Airport efficiency is important because it has a direct impact on customer safety and satisfaction and therefore the financial performance and sustainability of airports, airlines, and affiliated service providers. This is especially so in a world characterized by an increasing volume of both domestic and international air travel, price and other forms of competition between rival airports, airport hubs and airlines, and rapid and sometimes unexpected changes in airline routes and carriers. It also reflects expansion in the number of airports handling regional, national, and international traffic and the growth of complementary airport facilities including industrial, commercial, and retail premises. This has fostered a steadily increasing volume of research aimed at modeling and providing best-practice measures and estimates of airport efficiency using mathematical and econometric frontiers. The purpose of this chapter is to review these various methods as they apply to airports throughout the world. Apart from discussing the strengths and weaknesses of the different approaches and their key findings, the paper also examines the steps faced by researchers as they move through the modeling process in defining airport inputs and outputs and the purported efficiency drivers. Accordingly, the chapter provides guidance to those conducting empirical research on airport efficiency and serves as an aid for aviation regulators and airport operators among others interpreting airport efficiency research outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports a comparison of the practicality, acceptability and face validity of five dietary intake methods in two remote Australian Aboriginal communities: weighed dietary intake, 24‐hour recall, ‘store‐turnover’, diet history and food frequency methods. The methods used to measure individual dietary intake were poorly accepted by the communities. Quantitative data were obtained only from the first three methods. The 24‐hour recall method tended to produce higher nutrient intakes than the weighed intake method and certain foods appeared to be selectively recalled according to perceived nutritional desirability. The ‘store‐turnover’ method was most acceptable to the communities and had less potential for bias than the other methods. It was also relatively objective, non‐intrusive, rapid, easy and inexpensive. However, food distribution patterns within the communities could not be assessed by this method. Nevertheless, other similarly isolated communities may benefit by use of the ‘store‐turnover’ method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Self-selection-whether individuals inclined to walk more seek to live in walkable environments-must be accounted for when studying built environment influences on walking. The way neighborhoods are marketed to future residents has the potential to sway residential location choice, and may consequently affect measures of self-selection related to location preferences. We assessed how walking opportunities are promoted to potential buyers, by examining walkability attributes in marketing materials for housing developments. Methods: A content analysis of marketing materials for 32 new housing developments in Perth, Australia was undertaken, to assess how walking was promoted in the text and pictures. Housing developments designed to be pedestrian-friendly (LDs) were compared with conventional developments (CDs). Results: Compared with CDs, LD marketing materials had significantly more references to 'public transport,' small home sites,' walkable parks/open space,' ease of cycling,' safe environment,' and 'boardwalks.' Other walkability attributes approached significance. Conclusion: Findings suggest the way neighborhoods are marketed may contribute to self-reported reasons for choosing particular neighborhoods, especially when attributes are not present at the time of purchase. The marketing of housing developments may be an important factor to consider when measuring self-selection, and its influence on the built environment and walking relationship.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Rapid developments in technology have encouraged the use of smartphones in physical activity research, although little is known regarding their effectiveness as measurement and intervention tools. Objective This study systematically reviewed evidence on smartphones and their viability for measuring and influencing physical activity. Data Sources Research articles were identified in September 2013 by literature searches in Web of Knowledge, PubMed, PsycINFO, EBSCO, and ScienceDirect. Study Selection The search was restricted using the terms (physical activity OR exercise OR fitness) AND (smartphone* OR mobile phone* OR cell phone*) AND (measurement OR intervention). Reviewed articles were required to be published in international academic peer-reviewed journals, or in full text from international scientific conferences, and focused on measuring physical activity through smartphone processing data and influencing people to be more active through smartphone applications. Study Appraisal and Synthesis Methods Two reviewers independently performed the selection of articles and examined titles and abstracts to exclude those out of scope. Data on study characteristics, technologies used to objectively measure physical activity, strategies applied to influence activity; and the main study findings were extracted and reported. Results A total of 26 articles (with the first published in 2007) met inclusion criteria. All studies were conducted in highly economically advantaged countries; 12 articles focused on special populations (e.g. obese patients). Studies measured physical activity using native mobile features, and/or an external device linked to an application. Measurement accuracy ranged from 52 to 100 % (n = 10 studies). A total of 17 articles implemented and evaluated an intervention. Smartphone strategies to influence physical activity tended to be ad hoc, rather than theory-based approaches; physical activity profiles, goal setting, real-time feedback, social support networking, and online expert consultation were identified as the most useful strategies to encourage physical activity change. Only five studies assessed physical activity intervention effects; all used step counts as the outcome measure. Four studies (three pre–post and one comparative) reported physical activity increases (12–42 participants, 800–1,104 steps/day, 2 weeks–6 months), and one case-control study reported physical activity maintenance (n = 200 participants; >10,000 steps/day) over 3 months. Limitations Smartphone use is a relatively new field of study in physical activity research, and consequently the evidence base is emerging. Conclusions Few studies identified in this review considered the validity of phone-based assessment of physical activity. Those that did report on measurement properties found average-to-excellent levels of accuracy for different behaviors. The range of novel and engaging intervention strategies used by smartphones, and user perceptions on their usefulness and viability, highlights the potential such technology has for physical activity promotion. However, intervention effects reported in the extant literature are modest at best, and future studies need to utilize randomized controlled trial research designs, larger sample sizes, and longer study periods to better explore the physical activity measurement and intervention capabilities of smartphones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background There are few theoretically derived questionnaires of physical activity determinants among youth, and the existing questionnaires have not been subjected to tests of factorial validity and invariance, The present study employed confirmatory factor analysis (CFA) to test the factorial validity and invariance of questionnaires designed to be unidimensional measures of attitudes, subjective norms, perceived behavioral control, and self-efficacy about physical activity. Methods Adolescent girls in eighth grade from two cohorts (N = 955 and 1,797) completed the questionnaires at baseline; participants from cohort 1 (N = 845) also completed the questionnaires in ninth grade (i.e., 1-year follow-up). Factorial validity and invariance were tested using CFA with full-information maximum likelihood estimation in AMOS 4.0, Initially, baseline data from cohort 1 were employed to test the fit and, when necessary, to modify the unidimensional models. The models were cross-validated using a multigroup analysis of factorial invariance on baseline data from cohorts 1 and 2, The models then were subjected to a longitudinal analysis of factorial invariance using baseline and follow-up data from cohort i, Results The CFAs supported the fit of unidimensional models to the four questionnaires, and the models were cross-validated, as indicated by evidence of multigroup factorial invariance, The models also possessed evidence of longitudinal factorial invariance. Conclusions Evidence was provided for the factorial validity and the invariance of the questionnaires designed to be unidimensional measures of attitudes, subjective norms, perceived behavioral control, and self-efficacy about physical activity among adolescent girls, (C) 2000 American Health Foundation and academic Press.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and; 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry. METHODS Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b^{2} portable indirect calorimeter during two measurement sessions in which they performed the six minute walk test (6MWT) at three self-selected speeds (comfortable/slow, brisk, fast). Oxygen consumption (VO2) and accelerometer step and activity count data were recorded. RESULTS Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96-0.99, CI_{95}: 0.81-0.99). Reproducibility of the protocol was good/excellent (ICC=0.75-0.95, CI_{95}: 0.75-0.98). Concurrent validity of accelerometer count data and VO2 was fair/good (rho=0.67, p< 0.001). The correlation between step count and VO2 was not significant (rho=0.29, p=0.2). CONCLUSION This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Skin temperature assessment has historically been undertaken with conductive devices affixed to the skin. With the development of technology, infrared devices are increasingly utilised in the measurement of skin temperature. Therefore, our purpose was to evaluate the agreement between four skin temperature devices at rest, during exercise in the heat, and recovery. Methods: Mean skin temperature (T̅sk) was assessed in thirty healthy males during 30 min rest (24.0± 1.2°C, 56 ± 8%), 30 min cycle in the heat (38.0 ± 0.5°C, 41 ± 2%), and 45 min recovery(24.0 ± 1.3°C, 56 ± 9%). T̅sk was assessed at four sites using two conductive devices(thermistors, iButtons) and two infrared devices (infrared thermometer, infrared camera). Results: Bland–Altman plots demonstrated mean bias ± limits of agreement between the thermistors and iButtons as follows (rest, exercise, recovery): -0.01 ± 0.04, 0.26 ± 0.85, -0.37 ± 0.98°C; thermistors and infrared thermometer: 0.34 ± 0.44, -0.44 ± 1.23, -1.04 ± 1.75°C; thermistors and infrared camera (rest, recovery): 0.83 ± 0.77, 1.88 ± 1.87°C. Pairwise comparisons of T̅sk found significant differences (p < 0.05) between thermistors and both infrared devices during resting conditions, and significant differences between the thermistors and all other devices tested during exercise in the heat and recovery. Conclusions: These results indicate poor agreement between conductive and infrared devices at rest, during exercise in the heat, and subsequent recovery. Infrared devices may not be suitable for monitoring T̅sk in the presence of, or following, metabolic and environmental induced heat stress.