997 resultados para LP simples
Resumo:
Elevated plasma levels of lipoprotein-associated phospholipase A(2) (Lp-PLA2) activity have been shown to be associated with increased risk of coronary heart disease and an inhibitor of this enzyme is under development for the treatment of that condition. A Val279Phe null allele in this gene, that may influence patient eligibility for treatment, is relatively common in East Asians but has not been observed in Europeans. We investigated the existence and functional effects of low frequency alleles in a Western European population by re-sequencing the exons of PLA2G7 in 2000 samples. In all, 19 non-synonymous single-nucleotide polymorphisms (nsSNPs) were found, 14 in fewer than four subjects (minor allele frequency <0.1%). Lp-PLA2 activity was significantly lower in rare nsSNP carriers compared with non-carriers (167.8±63.2 vs 204.6±41.8, P=0.01) and seven variants had enzyme activities consistent with a null allele. The cumulative frequency of these null alleles was 0.25%, so <1 in 10,000 Europeans would be expected to be homozygous, and thus not potentially benefit from treatment with an Lp-PLA2 inhibitor.
Resumo:
Objetivando avaliar o efeito de diferentes doses de superfosfato simples e vermicomposto no crescimento de mudas de gravioleira (Anonna muricata L.), conduziu-se um experimento no Setor de Fruticultura da Universidade Federal de Lavras. Foram testadas, num Latossolo, quatro doses de superfosfato simples (0,0; 2,5; 5,0 e 10,0 kg) e quatro doses de vermicomposto (0; 10; 20 e 40%) m-3 de substrato. O delineamento experimental utilizado foi blocos ao acaso em esquema fatorial 4 x 4, com 4 repetições. Foram realizadas as seguintes determinações: altura de plantas (cm), diâmetro do caule (cm), número de folha/planta, área foliar (cm².planta-1), matéria seca de folha, do caule e de raiz (g.planta-1). Os resultados demonstraram que a aplicação de superfosfato simples na dose de 5 kg e 40% de vermicomposto por m³ de substrato proporcionaram a obtenção de mudas de gravioleira mais vigorosas.
Resumo:
O autor relata um achado de cisto simples no testículo de um paciente adulto durante estudo ultra-sonográfico. Faz uma revisão da literatura, sugere acompanhamento e conduta conservadora.
Resumo:
OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM) com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla). MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba injetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA) em 21 pacientes e dose simples (0,1 mmol/kg) em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p < 0,05) no grau de visualização das diversas estruturas analisadas entre os grupos dose simples e dose dupla, com uma exceção isolada: na avaliação da artéria hepática direita (p = 0,008), o grupo dose simples apresentou maior freqüência de visualização grau 2, com valor significante. CONCLUSÃO: O grau de visualização dos segmentos vasculares hepatomesentéricos pela angio-RM com contraste é elevado, sendo maior nos segmentos proximais e de maior calibre. A comparação entre os grupos que utilizaram dose simples e dupla de contraste demonstrou resultados semelhantes.
Resumo:
OBJETIVO: Estabelecer o valor das seqüências ponderadas em T2 para diferenciar cistos simples de hemangiomas hepáticos. MATERIAIS E MÉTODOS: Estudo prospectivo, observacional, transversal e duplo-cego em 52 pacientes com 91 lesões hepáticas (34 cistos simples e 57 hemangiomas) submetidos a ressonância magnética de abdome. A análise conjunta de todas as seqüências realizadas foi considerada o padrão-ouro. Dois observadores independentes avaliaram, subjetivamente, as seqüências TSE com TE longo e B-FFE, procurando diferenciar cistos de hemangiomas. Foram calculadas a eficácia das seqüências e a concordância interobservador e intra-observador por meio do teste kappa (κ) (p < 0,05*). RESULTADOS: As dimensões dos cistos variaram entre 0,5 e 6,5 cm (média de 1,89 cm) e as dos hemangiomas, entre 0,8 e 11 cm (média de 2,62 cm). A concordância entre a avaliação da seqüência com TE longo e o padrão-ouro foi insignificante (κ: 0,00-0,10). A concordância entre a avaliação da seqüência B-FFE e o padrão-ouro variou de substancial (κ: 0,62-0,71) a quase perfeita (κ: 0,86) para ambos os examinadores. A concordância interobservador e intra-observador para a seqüência B-FFE variou entre substancial (κ: 0,62-0,70) e quase perfeita (κ: 0,85-0,91). CONCLUSÃO: A técnica B-FFE apresenta eficácia e reprodutibilidade elevadas na diferenciação de cistos e hemangiomas.
Resumo:
OBJETIVO: Apresentar uma ferramenta de análise de dados que pode ser utilizada para proteção de pacientes e trabalhadores em áreas de uso de equipamentos móveis. MATERIAIS E MÉTODOS: Foi desenvolvida uma ferramenta, em planilha ativa Excel®, que utiliza medidas de exposição para gerar um banco de dados de fatores de forma e calcular o kerma no ar ao entorno de um leito. O banco de dados inicial foi coletado com três equipamentos móveis. Um espalhador não antropomórfico foi utilizado, sendo realizadas medidas de exposição em uma malha de (4,2 × 4,2) m², ao passo de 0,3 m. RESULTADOS: A ferramenta calcula o kerma no ar (associado à exposição de pacientes expostos e ao equivalente de dose ambiente) à radiação secundária. Para distâncias inferiores a 60,0 cm, valores acima do limite máximo de equivalente de dose ambiente definido para área livre (0,5 mSv/ano) foram verificados. Os dados coletados a 2,1 m foram sempre inferiores a 12% do referido limite. CONCLUSÃO: A ferramenta é capaz de auxiliar na proteção radiológica de pacientes e trabalhadores, quando associada à coleta de dados adequada, pois possibilita a determinação de áreas livres ao entorno de leitos em áreas onde equipamentos móveis geradores de radiação X são utilizados.
Resumo:
A simple laboratory technique is described for the synthesis of cyclopentadienylthallium and methylcyclopentadienylthallium and their use in the preparation of air sensitive metallocenes in solution. It does not use manifold, drybox or any other special glassware and was applied to the synthesis of cobaltocene, nickelocene and their methyl substituted analogs.
Uma célula simples para adaptação de eletrodos seletivos comerciais em sistemas de análises em fluxo
Resumo:
A simple flow cell for potentiometric detection is described. It was assembled by making use of two perspex pieces fixed together by means of four screws, and allow the connection of plane membrane conventional electrodes to flow system. Details about its construction are presented. The device performance was evaluated by making use of a cyanide ion-selective electrode. The relative standard deviation was about 0.5% with a detection limit of 8.0 x 10-6 mol CN- dm-3. Under experimental conditions, the linear range was 10-5 to10-2 mol dm-3.
Resumo:
Some aspects of electrochromism phenomena are presented in this review paper. A deep literature revision about the subject dealing with materials and device configurations developed in the last years, is presented. Great efforts of the scientific community have been done in this field. On the other hand, new electrochomic devices based on reversible deposition of metals are specially emphasized here. These devices present many advantages such as simple operation and construction and they have also shown high cycling rates. These factors make them suitable for application in display industry. In this way, many concepts used in the developement of electrodeposition baths are very useful for the improvement of these new devices; specially, all knowledge about the use of additives for modifying films microstructure and morfology.