136 resultados para KGF
Resumo:
The six-minute walking test can be affected by several variables, among them, the respiratory and peripheral muscle strength. The objective of this study was to correlate the respiratory muscle strength (maximum inspiratory pressure – MIP; and maximum expiratory pressure – MEP) and the hand grip test (HGT)with the six minute walking test distance in institutionalized elderly. It was included in this study 9 institutionalized elderly with age over 70 years old, both gender, evaluated by means of manometer, dynamometry and six minute walking test. The data were correlated by using the Pearson’s correlation test and the Spearman correlation test. From the evaluated elderly, it was four men and five women, with mean age: 78.8±7.3 years old, MIP: 75.7±33.6 cmH2O, MEP: 62.4±25.0 cmH2O, HGT: 20.4±6.2 kgf (right member) and 20.7±6.8 kgf (left member) and the distance on six minute walking test: 238.5±99.0 meters. There was correlation between expiratory strength and hand grip of both members with the distance on the six minute walking test. It is possible to conclude that there are correlation between expiratory muscle strength with the hand grip test and the functional capacity in institucionalized elderly.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Pós-graduação em Ciência e Tecnologia Animal - FEIS
Resumo:
Objective. To determine the effects of different aging methods on the degradation and flexural strength of yttria-stabilized tetragonal zirconia (Y-TZP)Methods. Sixty disc-shaped specimens (0, 12 mm; thickness, 1.6 mm) of zirconia (Vita InCeram 2000 YZ Cubes, VITA Zahnfabrik) were prepared (ISO 6872) and randomly divided into five groups, according to the aging procedures (n=10): (C) control; (M) mechanical cycling (15,000,000 cycles/3.8 Hz/200N); (T) thermal cycling (6,000 cycles/5-55 degrees C/30 s); (TM) thermomechanical cycling (1,200,000 cycles/3.8 Hz/200N with temperature range from 5 C to 55 C for 60s each); (AUT) 12h in autoclave at 134 degrees C/2 bars; and (STO) storage in distilled water (37 degrees C/400 days). After the aging procedures, the monoclinic phase percentages were evaluated by X-ray diffraction (XRD), and topographic surface analysis was performed by 3D profilometry. The specimens were then subjected to biaxial flexure testing (1 mm/min, load 100 kgf, in water). The biaxial flexural strength data (MPa) were analyzed by 1-way ANOVA and Tukey's test (alpha = 0.05). The data for monoclinic phase percentage and profilometry (Ra) were analyzed by Kruskal-Wallis and Dunn's tests.Results. ANOVA revealed that flexural strength was affected by the aging procedures (p = 0.002). The M (781.6 MPa) and TM (771.3 MPa) groups presented lower values of flexural strength than did C (955 MPa), AUT (955.8 MPa), T (960.8 MPa) and STO (910.4 MPa). The monoclinic phase percentage was significantly higher only for STO (12.22%) and AUT (29.97%) when compared with that of the control group (Kruskal-Wallis test, p = 0.004). In addition, the surface roughnesses were similar among the groups (p = 0.165).Signcance. Water storage for 400 days and autoclave aging procedures induced higher phase transformation from tetragonal to monoclinic; however, they did not affect the flexural strength of Y-TZP ceramic, which decreased only after mechanical and thermomechanical cycling. (C) 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
The objective of this study was to compare the efficiency of washing and trimming broiler carcasses to reduce bacterial contamination. At the poste-visceration site, 100 broiler carcasses were collected during 4 visits to a slaughterhouse in Santa Catarina State, Brazil. Birds were from the same flock, age, and approximately 2.4 kg of weight. Groups were as follows: group 1, with fecal contamination; group 2, without fecal contamination; group 3, with fecal contamination and trimmed; group 4, with fecal contamination and washed; group 5, with fecal contamination, and washed and trimmed. Carcass washings were performed with at least 1.5 L/bird of potable water (0.5 to 1 mg/kg of residual chlorine) at room temperature (20-25 degrees C) using spray cabinets with 44 spray nozzles distributed into 2 chambers (pressure of 2 kgf/cm(2) and 4 kgf/cm(2)). Washed carcasses (trimmed or not) showed significantly (P < 0.05) lower counts of aerobic mesophiles (plate count agar) on the third evaluation, and even lower (P < 0.01) counts for total coliforms (CT) and fecal coliforms (Escherichia coli). Trimmed carcasses showed significantly lower counts (P < 0.05) for plate count agar; however, we observed higher counts for E. coli (P < 0.05). The association of both treatments (washing and trimming) showed significantly higher (P < 0.05) counts for coliforms (CT and E. coli). We can conclude that the washing method is overall more efficient than the trimming method to decontaminate chicken carcasses at the postevisceration site. Hopefully, our findings can help poultry companies to minimize production costs by applying the washing method for carcass decontamination.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The research aimed to produce sheets of particles with waste processing of Eucalyptus sp bonded with urea-formaldehyde and evaluate the effect of pressure variation in the quality of the boards produced. To do so, the Boards made were divided into two treatments depending on the pressing pressure of 30 to 40 kgf / cm². Once pressings, climatized, the particleboards have been sectioned in test samples, and underwent physical-mechanical tests for determining density, swelling and water absorption, modulus of rupture and elasticity in static bending and internal linking. The particleboards pressed at 40 kgf / cm ² showed the best results
Resumo:
The purpose of this study was to investigate the validity of critical force test from maximal lactate steady state (MLSS) during resistance test using straight bench press. Five healthy male volunteers aged (22.6 ± 2.88 years), weight (76.3 ± 11.49 kg) e height (182.6 ± 7.54cm), trained in resistance exercise, and performed four diferent test to determine: one maximal effort (1RM), critical force using the critical power model (force vs 1/time limit - 20, 25 and 30% 1RM). The CF was the linear coefficient and the anaerobic impulse capacity (CIA) was the angular. MLSS was determined using loads of 80, 90, 100 and 110% of critical force. Blood lactate samples were abtained at each 300sec between each stage of total 1200sec. Maximal 30s test (M30) was accomplished with load of 25% of body weight in SBP. The results showed that the 1 RM was 79.4 Kgf (± 16.98), CF 10.1N (± 2.25), CIA 1756.82 N.s (± 546.96) and the R² 0.984 (± 0,02). The MLSS occurs at 100% CF load. The lactate concentration at the MLSS was 2.2 mmol/L (± 0.77). Significant correlation was observed between MLSS and CF on SBP (r = 0.88 p = 0.05). In M30 the minimum, mean and peak power were (25.0 ± 4.9, 28.0 ± 4.9, and 30.0 ± 4.6 kgf.rps, respectively). The fatigue index was 18.0% (± 6,8). The M30 was significantly correlated with Ppeak and Pmean (r = 0.98 for both, p = 0.003). The CF means has been validated to predict the resistance training and the CIA show to be a representative anaerobic parameter in straight bench press.
Resumo:
This work presents a study that aims to validate the fatigue analyses developed on finite element commercial software, ANSYS Workbench. It was based on mechanical tests development of traction and hardness, to verify the mechanical properties of material that the shaft was manufactured (ABNT 1045 steel), it was developed bend test, with purpose to prove the confiability degree of computational analyses, obtaining the maximum stress in a work condition determined with 40 [kgf] of load applied, and at the end, was developed the fatigue test to obtain the number of cycles that the transmission shaft can support in a work condition with 8 [kgf] of load applied. The results obtained during the work present, have to be quite satisfactory with the theoretically expected
Resumo:
This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.
Resumo:
In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT
Resumo:
Pós-graduação em Odontologia Restauradora - ICT