973 resultados para Implantable Infusion pumps


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Barbiturate-induced coma can be used in patients to treat intractable intracranial hypertension when other therapies, such as osmotic therapy and sedation, have failed. Despite control of intracranial pressure, cerebral infarction may still occur in some patients, and the effect of barbiturates on outcome remains uncertain. In this study, we examined the relationship between barbiturate infusion and brain tissue oxygen (PbtO2). METHODS: Ten volume-resuscitated brain-injured patients who were treated with pentobarbital infusion for intracranial hypertension and underwent PbtO2 monitoring were studied in a neurosurgical intensive care unit at a university-based Level I trauma center. PbtO2, intracranial pressure (ICP), mean arterial pressure, cerebral perfusion pressure (CPP), and brain temperature were continuously monitored and compared in settings in which barbiturates were or were not administered. RESULTS: Data were available from 1595 hours of PbtO2 monitoring. When pentobarbital administration began, the mean ICP, CPP, and PbtO2 were 18 +/- 10, 72 +/- 18, and 28 +/- 12 mm Hg, respectively. During the 3 hours before barbiturate infusion, the maximum ICP was 24 +/- 13 mm Hg and the minimum CPP was 65 +/- 20 mm Hg. In the majority of patients (70%), we observed an increase in PbtO2 associated with pentobarbital infusion. Within this group, logistic regression analysis demonstrated that a higher likelihood of compromised brain oxygen (PbtO2 < 20 mm Hg) was associated with a decrease in pentobarbital dose after controlling for ICP and other physiological parameters (P < 0.001). In the remaining 3 patients, pentobarbital was associated with lower PbtO2 levels. These patients had higher ICP, lower CPP, and later initiation of barbiturates compared with patients whose PbtO2 increased. CONCLUSION: Our preliminary findings suggest that pentobarbital administered for intractable intracranial hypertension is associated with a significant and independent increase in PbtO2 in the majority of patients. However, in some patients with more compromised brain physiology, pentobarbital may have a negative effect on PbtO2, particularly if administered late. Larger studies are needed to examine the relationship between barbiturates and cerebral oxygenation in brain-injured patients with refractory intracranial hypertension and to determine whether PbtO2 responses can help guide therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of a synthetic atrial natriuretic peptide (h-ANP, 25 amino acids, Wy-47.663) on blood pressure, renal electrolyte excretion, plasma catecholamines, and plasma renin activity was studied in nine patients with cirrhosis of the liver and ascites. The peptide was infused intravenously at 24-h intervals for 2 h in groups of four patients each in two different doses (0.015 and 0.075 micrograms/kg/min or 0.06 and 0.3 micrograms/kg/min). A control experiment with the vehicle was performed in all patients. In three patients h-ANP (1 and 2 micrograms/kg i.v.) was administered as an intravenous bolus injection. Consistent falls in blood pressure were observed during h-ANP infusion only with the two higher doses. The two lower infused doses induced a consistent natriuresis; this renal response was abolished when the two larger doses were used. When given as a bolus, h-ANP had a natriuretic effect comparable to that of the two lower doses of infused h-ANP. Plasma catecholamines and plasma renin activity increased during infusion of the two higher doses of h-ANP. It thus appears that in patients with cirrhosis and ascites, the natriuretic effect of infused h-ANP decreases rather than increases when the doses are raised. Bolus administration of h-ANP may be less prone to trigger counterbalancing responses and side-effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Full signal intensity (1)H-[(13)C] NMR spectroscopy, combining a preceding (13)C-editing block based on an inversion BISEP (B(1)-insensitive spectral editing pulse) with a spin-echo coherence-based localization, was developed and implemented at 14.1 T. (13)C editing of the proposed scheme was achieved by turning on and off the (13)C adiabatic full passage in the (13)C-editing block to prepare inverted and noninverted (13)C-coupled (1)H coherences along the longitudinal axis prior to localization. The novel (1)H-[(13)C] NMR approach was applied in vivo under infusion of the glia-specific substrate [2-(13)C] acetate. Besides a approximately 50% improvement in sensitivity, spectral dispersion was enhanced at 14.1 T, especially for J-coupled metabolites such as glutamate and glutamine. A more distinct spectral structure at 1.9-2.2 ppm(parts per million) was observed, e.g., glutamate C3 showed a doublet pattern in both simulated (1)H spectrum and in vivo (13)C-edited (1)H NMR spectra. Besides (13)C time courses of glutamate C4 and glutamine C4, the time courses of glutamate C3 and glutamine C3 obtained by (1)H-[(13)C] NMR spectroscopy were reported for the first time. Such capability should greatly improve the ability to study neuron-glial metabolism using (1)H-observed (13)C-edited NMR spectroscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The alpha1-adrenergic receptors (alpha1-ARs) play a key role in cardiovascular homeostasis. However, the functional role of alpha1-AR subtypes in vivo is still unclear. The aim of this study was to evaluate the cardiovascular influences of alpha1b-AR. METHODS AND RESULTS: In transgenic mice lacking alpha1-AR (KO) and their wild-type controls (WT), we evaluated blood pressure profile and cardiovascular remodeling induced by the chronic administration (18 days via osmotic pumps) of norepinephrine, angiotensin II, and subpressor doses of phenylephrine. Our results indicate that norepinephrine induced an increase in blood pressure levels only in WT mice. In contrast, the hypertensive state induced by angiotensin II was comparable between WT and KO mice. Phenylephrine did not modify blood pressure levels in either WT or KO mice. The cardiac hypertrophy and eutrophic vascular remodeling evoked by norepinephrine was observed only in WT mice, and this effect was independent of the hypertensive state because it was similar to that observed during subpressor phenylephrine infusion. Finally, the cardiac hypertrophy induced by thoracic aortic constriction was comparable between WT and KO mice. CONCLUSIONS: Our data demonstrate that the lack of alpha1b-AR protects from the chronic increase of arterial blood pressure induced by norepinephrine and concomitantly prevents cardiovascular remodeling evoked by adrenergic activation independently of blood pressure levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the role of the murine hepatoportal glucose sensor in the control of whole-body glucose metabolism, we infused glucose at a rate corresponding to the endogenous glucose production rate through the portal vein of conscious mice (Po-mice) that were fasted for 6 h. Mice infused with glucose at the same rate through the femoral vein (Fe-mice) and mice infused with a saline solution (Sal-mice) were used as controls. In Po-mice, hypoglycemia progressively developed until glucose levels dropped to a nadir of 2.3 +/- 0.1 mmol/l, whereas in Fe-mice, glycemia rapidly and transiently developed, and glucose levels increased to 7.7 +/- 0.6 mmol/l before progressively returning to fasting glycemic levels. Plasma insulin levels were similar in both Po- and Fe-mice during and at the end of the infusion periods (21.2 +/- 2.2 vs. 25.7 +/- 0.9 microU/ml, respectively, at 180 min of infusion). The whole-body glucose turnover rate was significantly higher in Po-mice than in Fe-mice (45.9 +/- 3.8 vs. 37.7 +/- 2.0 mg x kg(-1) x min)-1), respectively) and in Sal-mice (24.4 +/- 1.8 mg x kg(-1) x min(-1)). Somatostatin co-infusion with glucose in Po-mice prevented hypoglycemia without modifying the plasma insulin profile. Finally, tissue glucose clearance, which was determined after injecting 14C-2-deoxyglucose, increased to a higher level in Po-mice versus Fe-mice in the heart, brown adipose tissue, and the soleus muscle. Our data show that stimulation of the hepatoportal glucose sensor induced hypoglycemia and increased glucose utilization by a combination of insulin-dependent and insulin-independent or -sensitizing mechanisms. Furthermore, activation of the glucose sensor and/or transmission of its signal to target tissues can be blocked by somatostatin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction:  Targeted intrathecal drug infusion to treat moderate to severe chronic pain has become a standard part of treatment algorithms when more conservative options fail. This therapy is well established in the literature, has shown efficacy, and is an important tool for the treatment of both cancer and noncancer pain; however, it has become clear in recent years that intrathecal drug delivery is associated with risks for serious morbidity and mortality. Methods:  The Polyanalgesic Consensus Conference is a meeting of experienced implanting physicians who strive to improve care in those receiving implantable devices. Employing data generated through an extensive literature search combined with clinical experience, this work group formulated recommendations regarding awareness, education, and mitigation of the morbidity and mortality associated with intrathecal therapy to establish best practices for targeted intrathecal drug delivery systems. Results:  Best practices for improved patient care and outcomes with targeted intrathecal infusion are recommended to minimize the risk of morbidity and mortality. Areas of focus include respiratory depression, infection, granuloma, device-related complications, endocrinopathies, and human error. Specific guidance is given with each of these issues and the general use of the therapy. Conclusions:  Targeted intrathecal drug delivery systems are associated with risks for morbidity and mortality that can be devastating. The panel has given guidance to treating physicians and healthcare providers to reduce the incidence of these problems and to improve outcomes when problems occur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Direct-infusion ESI-MS/MS is a powerful approach for the identification of substances in complex mixtures. The aim of this work was to investigate its applicability to the toxicological screening of blood samples. A simple protein precipitation was used, followed by a 15 min infusion of the extract in the mass spectrometer. RESULTS: The application of the procedure to commercial quality controls and authentic post-mortem blood samples demonstrated that the direct-infusion ESI-MS/MS approach enables the simultaneous identification of substances that require different chromatographic conditions. However, poor sensitivity was observed for benzodiazepine, amphetamines and opiate compounds. CONCLUSION: Considering the facile implementation and positive performance of direct-infusion ESI-MS/MS, this approach may to be a valuable complementary technique for systematic toxicological analysis procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of combined long-chain triglyceride infusion (Intralipid 20%) with graded doses of insulin/glucose on energy expenditure was examined in 17 healthy young male volunteers by using the euglycemic insulin clamp technique in combination with indirect calorimetry. Intralipid was infused for 90 min at a constant rate of 0.23 g/min; plasma free fatty acids increased from base-line values of 380 +/- 8 mumol/l to steady state levels of 650 +/- 12 mumol/l. After 90 min the Intralipid was continued and insulin was infused at three rates (0.5, 2, and 4 mU/kg . min) to achieve steady state hyperinsulinemic plateaus of 63 +/- 4, 167 +/- 10, and 410 +/- 15 microU/ml. Plasma glucose concentration was maintained constant at basal euglycemic levels (insulin clamp technique) by infusing glucose at 0.24, 0.48, and 0.59 g/min, respectively. Glucose storage during the insulin clamp (ie, glucose uptake minus glucose oxidation) was 0.13, 0.33, and 0.40 g/min for each group and exogenous lipid storage was 0.17, 0.18, and 0.19 g/min, respectively. The net increment in energy expenditure was 0.15, 0.24, and 0.26 kcal/min, respectively, which represents 8.5% of the energy content of the total amount of glucose and lipid stored. The experimentally determined value (approximately 9%) for the cost of storing both glucose and lipid was found to be significantly greater than predicted by stoichiometric calculations. However, the experimental value for the combined infusion was less than that observed for glucose storage alone (12%). This finding provides support for the use of combined glucose/fat infusions in parenteral nutrition as it is used more economically than when glucose is infused alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Major burns are characterized by an initial capillary leak, which requires fluid resuscitation for hemodynamic stabilization. While under resuscitation was the major cause of death until the 1980s, over resuscitation has become an important source of complications, including abdominal compartment syndrome, escharosis, impaired gas exchange with prolonged mechanical ventilation and hospital stay. Fluid over infusion started in the 1990s with an increasing proportion of the fluid delivered within the first 24 h being well above the 4 ml/kg/% burn surface area (BSA) according to the Parkland formula. The first alerts were published in the form of case reports of increased mortality due to abdominal compartment syndrome and respiratory failure. This paper analyses the causes of this fluid over infusion and the ways to prevent it, which include rationing prehospital fluid delivery, avoiding early administration of colloids and prevention by permissive hypovolemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic atrial fibrillation affects millions of people worldwide. Its surgical treatment often fails to restore the transport function of the atrium. This study first introduces the concept of an atrial assist device (AAD) to restore the pump function of the atrium. The AAD is developed to be totally implantable in the human body with a transcutaneous energy transfer system to recharge the implanted battery. The ADD consists of a motorless pump based on artificial muscle technology, positioned on the external surface of the atrium to compress it and restore its muscular activity. A bench model reproduces the function of a fibrillating atrium to assess the circulatory support that this pump can provide. Atripump (Nanopowers SA, Switzerland) is a dome-shaped silicone-coated nitinol actuator 5 mm high, sutured on the external surface of the atrium. A pacemaker-like control unit drives the actuator that compresses the atrium, providing the mechanical support to the blood circulation. Electrical characteristics: the system is composed of one actuator that needs a minimal tension of 15 V and has a maximum current of 1.5 A with a 50% duty cycle. The implantable rechargeable battery is made of a cell having the following specifications: nominal tension of a cell: 4.1 V, tension after 90% of discharge: 3.5 V, nominal capacity of a cell: 163 mA h. The bench model consists of an open circuit made of latex bladder 60 mm in diameter filled with water. The bladder is connected to a vertically positioned tube that is filled to different levels, reproducing changes in cardiac preload. The Atripump is placed on the outer surface of the bladder. Pressure, volume and temperature changes were recorded. The contraction rate was 1 Hz with a power supply of 12 V, 400 mA for 200 ms. Preload ranged from 15 to 21 cm H(2)O. Maximal silicone membrane temperature was 55 degrees C and maximal temperature of the liquid environment was 35 degrees C. The pump produced a maximal work of 16 x 10(-3) J. Maximal volume pumped was 492 ml min(-1). This artificial muscle pump is compact, follows the Starling law and reproduces the hemodynamic performances of a normal atrium. It could represent a new tool to restore the atrial kick in persistent atrial fibrillation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mise au point sur le hotter implantable (Reveal®). Connaissances actuelles et implications thérapeutiques. La syncope est un problème fréquent touchant environ un tiers des adultes durant leur vie. C'est un motif de consultation habituel aux urgences et ses causes sont souvent multiples et rendent son diagnostic difficile. Malgré des investigations extensives et coûteuses la cause syncopale reste dans environ 30% des cas d'étiologie indéterminée. Les progrès récents dans le monitoring cardiaque à long terme ont permis d'inclure dans le choix des tests diagnostiques un outil très intéressant dans l'investigation de la syncope d'étiologie indéterminée (SOI). Il s'agit du moniteur ECG implantable (MEI) ou Reveal®. Il y a un peu plus de 10 ans un prototype de MEI a été implanté dans un petit collectif de patients souffrants de SOI récidivantes et a permis d'établir un diagnostic chez la plupart d'entre eux. Dès lors le système s'est modernisé avec une diminution importante de la taille et du poids permettant actuellement d'enregistrer le rythme cardiaque sur une durée de 18 à 24 mois. Le système peut stocker dans sa mémoire un tracé ECG soit à l'aide d'un activateur externe déclenché par le patient, soit de façon spontanée en présence d'un rythme cardiaque lent ou rapide. Son implantation se fait en anesthésie locale, en position sous-cutanée pectorale gauche. Les complications et les problèmes infectieux sont rares. Plusieurs études récentes se sont intéressées à l'apport diagnostique du MEI dans la prise en charge de la SOI. La plus grande porte sur un collectif de 206 patients. L'apport diagnostique des différentes études varie de 40% à 64%. Cependant la plupart de ces études ne comportaient pas de prise en charge standardisée ou avaient des critères d'inclusion précis. Nous nous sommes intéressés aux résultats de notre prise en charge de la syncope au cours de ces 6 dernières années. Une consultation spécialisée de la syncope a été mise en place en 1999. La consultation offre l'accès à tout le plateau technique propre à l'investigation de syncopes à savoir un tilt-test avec mesure continue non invasive de la pression artérielle, examens échocardiographiques et test d'effort. Si nécessaire, le bilan peut être complété par une étude électrophysiologique (EEP) et/ou une coronarographie: Tous les patients bénéficient d'une anamnèse ciblée suivi d'un examen clinique et d'un électrocardiogramme. Une échocardiographie n'est effectuée qu'en cas de suspicion de cardiopathie sous-jacente. Un holter ou R-test ne sont réalisés qu'en présence de syncopes ou palpitations fréquentes. Les investigations se poursuivent par un tilt test suivi d'un massage du sinus carotidien en position debout et couchée. Un test d'hyperventilation n'est pratiqué que chez les patients avec traits phobiques, dépressifs ou troubles de type panique. L'EEP n'est pratiquée que chez les patients dont la syncope reste d'étiologie indéterminée après investigations initiales et chez ceux souffrant d'une cardiopathie sous jacente documentée ; elle est aussi indiquée chez ceux dont le coeur est normal mais chez qui la syncope est associée à des traumatismes ou à l'origine d'un accident de voiture. Le MEI est proposé lorsque toutes les investigations initiales restent négatives, généralement chez les sujets ayant souffert de plus d'une syncope ou de complications sérieuses. Notre expérience pratique d'une consultation de la syncope ouverte au tout venant nous montre qu'une prise en charge standardisée non invasive permet d'identifier une cause syncopale chez plus de 60% des patients. Chez les patients souffrant de syncopes récidivantes ou traumatiques d'étiologie indéterminée après investigations conventionnelles, l'apport diagnostique du MEI est élevé (64%) durant un suivi moyen de 9 mois, ce qui permet d'identifier certaines causes syncopales écartées précédemment par des tests ciblés. Parmi ces dernières, retenons plus particulièrement les tachycardies nodales et crises d'épilepsie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal diseases are nowadays the most common causes of vision threatening in developed countries. Therapeutic advances in this field are hindered by the difficulty to deliver drugs to the posterior segment of the eye. Due to anatomical barriers, the ocular biodisponibility of systemically administered drugs remains poor, and topical instillation is not adequate to achieve therapeutic concentrations of drugs in the back of the eye. Ocular drug delivery has thus become one of the main challenges of modern ophthalmology. A multidisciplinary research is being conducted worldwide including pharmacology, biomaterials, ophthalmology, pharmaceutics, and biology. New promising fields have been developed such as implantable or injectable slow release intravitreal devices and degradable polymers, dispersed polymeric systems for intraocular drug delivery, and transscleral delivery devices such as iontophoresis, osmotic pumps or intra-scleraly implantable materials. The first clinical applications emerging from this research are now taking place, opening new avenues for the treatment of retinal diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An implantable cardiac defibrillator (ICD) is a cardiac implantable electronic device that is capable of identifying and treating ventricular arrhythmias. Consideration about the type of ICD to select for a given patient include whether the patient has bradycardia requiring pacing support, has associated atrial tachyarrhythmias, or would benefit from cardiac resynchronization therapy. The ICD functions by continuously monitoring the patient's cardiac rate and delivering therapies (anti-tachycardia pacing, shocks) when the rate exceeds the programmed rate "cutoff". Secondary prevention trials have demonstrated that ICDs reduce the incidence of arrhythmic death and total mortality in patients presenting with a cardiac arrest. ICDs are also indicated for primary prevention of sudden cardiac death in specific high-risk subgroups of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyclonal intravenous immunoglobulin (IVIg) treatment reduces crossmatch positivity and increases rates of transplantation in highly sensitised patients (HS). We quantified the panel reactive antibody (PRA) by microlymphocytotoxicity (MLCC), and we analysed anti-HLA class I and class II IgG specific antibody repertoire by Luminex before and after IVIg infusion alone in HS patients awaiting kidney transplantation. Five patients received three monthly infusions of 1 g/kg of IVIg. Serum samples collected pre and post IVIg treatment were submitted for PRA analysis by MLCC. Anti-class I and anti-class II antibody specificities were then tested by Luminex. We focused on the anti-HLA class I and class II antibodies directed against HLA expressed by a previous graft. We also analysed the anti-HLA antibody repertoire in three patients who had not received IVIg infusion. The PRA level determined by MLCC decreased significantly in one of the five patients, dropping from 40% to 17%. The Luminex assay showed fluctuations of the anti-HLA antibody levels over time, but no significant longterm modifications of the anti-HLA antibody repertoire were observed, even in the patient with a strong and prolonged reduction of the PRA determined by MLCC. Our results show that IVIg at 1 g/kg is not sufficient to reduce PRA and does not modify the repertoire of specific anti-HLA antibody determined by Luminex.