994 resultados para Implant surface


Relevância:

60.00% 60.00%

Publicador:

Resumo:

In modern implant dentistry there are several clinical indications for laser surgery. Different laser systems have a considerable spectrum of application in soft and hard peri-implant tissues. The literature was searched for clinical application of different laser wavelengths in peri-implant tissues: second-stage surgery of submerged implants, treatment of infrabony defects, removal of peri-implant hyperplastic overgrowths, and, possibly, the preparation of bone cavities for implant placement. This report describes the state-of-the-art application of different laser systems in modern implant dentistry for the treatment of peri-implant lesions and decontamination of implant surfaces. Our study evaluated in vitro examinations, clinical experience and long-term clinical studies. The exact selection of the appropriate laser system and wavelength was dependent on the scientific evaluation of recent literature and the level of changes in implant and tissue temperatures during laser application. The significant reduction in bacteria on the implant surface and the peri-implant tissues during irradiation and the cutting effects associated with the coagulation properties of the lasers are the main reasons for laser application in the treatment of peri-implant lesions and the successful long-term prognosis of failing oral implants. The various applications of lasers in implant dentistry are dependent on the wavelength and laser-tissue interactions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Zirconia (ZrO2 ) has received interest as a dental material; however, little information is available on the impact of surface modifications on the osseointegration of zirconia implants. PURPOSE: The aim of the present study was to determine the effect of acid or alkaline etching of sandblasted ZrO2 implants on bone apposition in vivo. METHODS: Cylindrical ZrO2 implants with two circumferential grooves were placed in the maxilla of 12 miniature pigs. Biopsies were harvested after 1, 2, 4, and 8 weeks of healing. Undecalcified toluidine blue-stained ground sections were produced. The bone-to-implant contact, the bone area, and the presence of multinucleated giant cells were determined by histomorphometry. An uncorrected explorative statistical analysis was performed. RESULTS: Acid etching but not alkaline etching of sandblasted ZrO2 implants caused more bone-to-implant contact than sandblasted ZrO2 implants. The bone area was unaffected by the surface modifications. Acid and alkaline etching both increased the formation of multinucleated giant cells at the implant surface. CONCLUSIONS: This study provides a scientific basis to further investigate the impact of acid etching of sandblasted ZrO2 implants on osseointegration and the role of multinucleated giant cells in this process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of the present review was to summarize the evidence available on the temporal sequence of hard and soft tissue healing around titanium dental implants in animal models and in humans. A search was undertaken to find animal and human studies reporting on the temporal dynamics of hard and soft tissue integration of titanium dental implants. Moreover, the influence of implant surface roughness and chemistry on the molecular mechanisms associated with osseointegration was also investigated. The findings indicated that the integration of titanium dental implants into hard and soft tissue represents the result of a complex cascade of biological events initiated by the surgical intervention. Implant placement into alveolar bone induces a cascade of healing events starting with clot formation and continuing with the maturation of bone in contact with the implant surface. From a genetic point of view, osseointegration is associated with a decrease in inflammation and an increase in osteogenesis-, angiogenesis- and neurogenesis-associated gene expression during the early stages of wound healing. The attachment and maturation of the soft tissue complex (i.e. epithelium and connective tissue) to implants becomes established 6-8 weeks following surgery. Based on the findings of the present review it can be concluded that improved understanding of the mechanisms associated with osseointegration will provide leads and targets for strategies aimed at enhancing the clinical performance of titanium dental implants.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the role of the periosteum in preserving the buccal bone after ridge splitting and expansion with simultaneous implant placement. MATERIAL AND METHODS In 12 miniature pigs, the mandibular premolars and first molars were removed together with the interdental bone septa and the buccal bone. Three months later, ridge splitting and expansion of the buccal plate was performed with simultaneous placement of two titanium implants per quadrant. Access by a mucosal flap (MF) was prepared on test sides, while a mucoperiosteal flap (MPF) with complete denudation of the buccal bone was increased on control sides. After healing periods of six and 12 weeks, the animals were sacrificed for histologic and histometric evaluation. RESULTS In the MF group, all 16 implants were osseointegrated, while in the MPF group, four of 16 implants were lost. Noticeable differences of bone levels on the implant surface and of the bone crest (BC) were found between the MF and the MPF group. Buccally after 6 weeks, the median distance between the implant shoulder (IS) and the coronal-most bone on the implant (cBIC) was for the MF group -1.42 ± 0.42 mm and for the MPF group -4.80 ± 2.72 mm (P = 0.15). The median distance between the IS and the buccal BC was -1.24 ± 0.51 mm and -2.78 ± 1.98 mm (P = 0.12) for the MF and MPF group, respectively. After 12 weeks, median IS-cBIC was -2.12 ± 0.84 mm for MF and -7.19 mm for MPF, while IS-BC was -2.08 ± 0.79 mm for MF and -5.96 mm for MPF. After 6 weeks, the median buccal bone thickness for MF and MPF was 0.01 and 0 mm (P < 0.001) at IS, 1.48 ± 0.97 mm and 0 ± 0.77 mm (P = 0.07) at 2 mm apical to IS, and 2.12 ± 1.19 mm and 1.72 ± 01.50 mm (P = 0.86) at 4 mm apical to IS, respectively. After 12 weeks, buccal bone thickness in the MF group was 0 mm at IS, 0.21 mm at 2 mm apical to IS, and 2.56 mm at 4 mm apical to IS, whereas complete loss of buccal bone was measured from IS to 4 mm apical to IS for the MPF group. CONCLUSIONS In this ridge expansion model in miniature pigs, buccal bone volume was significantly better preserved when the periosteum remained attached to the bone.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study examined the impact of implant surface modifications on osseointegration in an osteoporotic rodent model. Sandblasted, acid-etched titanium implants were either used directly (control) or were further modified by surface conditioning with NaOH or by coating with one of the following active agents: collagen/chondroitin sulphate, simvastatin, or zoledronic acid. Control and modified implants were inserted into the proximal tibia of aged ovariectomised (OVX) osteoporotic rats (n = 32/group). In addition, aged oestrogen competent animals received either control or NaOH conditioned implants. Animals were sacrificed 2 and 4 weeks post-implantation. The excised tibiae were utilised for biomechanical and morphometric readouts (n = 8/group/readout). Biomechanical testing revealed at both time points dramatically reduced osseointegration in the tibia of oestrogen deprived osteoporotic animals compared to intact controls irrespective of NaOH exposure. Consistently, histomorphometric and microCT analyses demonstrated diminished bone-implant contact (BIC), peri-implant bone area (BA), bone volume/tissue volume (BV/TV) and bone-mineral density (BMD) in OVX animals. Surface coating with collagen/chondroitin sulphate had no detectable impact on osseointegration. Interestingly, statin coating resulted in a transient increase in BIC 2 weeks post-implantation; which, however, did not correspond to improvement of biomechanical readouts. Local exposure to zoledronic acid increased BIC, BA, BV/TV and BMD at 4 weeks. Yet this translated only into a non-significant improvement of biomechanical properties. In conclusion, this study presents a rodent model mimicking severely osteoporotic bone. Contrary to the other bioactive agents, locally released zoledronic acid had a positive impact on osseointegration albeit to a lesser extent than reported in less challenging models.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hydroxyapatite (HA) has received wide attention in orthopedics, due to its biocompatibility and osseointegration ability. Despite these advantages, the brittle nature and low fracture toughness of HA often results in rapid wear and premature fracture of implant. Hence, there is a need to improve the fracture toughness and wear resistance of HA without compromising its biocompatibility. ^ The aim of the current research is to explore the potential of nanotubes as reinforcement to HA for orthopedic implants. HA- 4 wt.% carbon nanotube (CNT) composites and coatings are synthesized by spark plasma sintering and plasma spraying respectively, and investigated for their mechanical, tribological and biological behavior. CNT reinforcement improves the fracture toughness (>90%) and wear resistance (>66%) of HA for coating and free standing composites. CNTs have demonstrated a positive influence on the proliferation, differentiation and matrix mineralization activities of osteoblasts, during in-vitro biocompatibility studies. In-vivo exposure of HA-CNT coated titanium implant in animal model (rat) shows excellent histocompatibility and neobone integration on the implant surface. The improved osseointegration due to presence of CNTs in HA is quantified by the adhesion strength measurement of single osteoblast using nano-scratch technique. ^ Considering the ongoing debate about cytotoxicity of CNTs in the literature, the present study also suggests boron nitride nanotube (BNNT) as an alternative reinforcement. BNNT with the similar elastic modulus and strength as CNT, were added to HA. The resulting composite having 4 wt.% BNNTs improved the fracture toughness (∼85%) and wear resistance (∼75%) of HA in the similar range as HA-CNT composites. BNNTs were found to be non-cytotoxic for osteoblasts and macrophages. In-vitro evaluation shows positive role of BNNT in osteoblast proliferation and viability. Apatite formability of BNNT surface in ∼4 days establishes its osseointegration ability.^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Desde 1965 em que se colocaram as primeiras próteses osteointegradas sob os princípios de Brånemark, a implantologia sofreu uma constante e notória evolução e consiste, hoje, na primeira linha de tratamento em reabilitação oral. Os mecanismos que induzem a adesão óssea ou a união entre o implante e o osso, ainda não são perfeitamente conhecidos. As conclusões que se obtiveram das pesquisas, demostraram que a taxa de osteointegração dos impantes e o índice de sucesso relacionam-se com a composição química e com a rugosidade da superfície. Os implantes com rugosidades superficiais possuem maior estabilidade primária e modificam os mecanismos de interação das células com a superfície, quando comparados com os de superfície lisa. Quanto à composição química das superfícies dos implantes, as enriquecidas com cálcio e hidroxiapatite, favorecem e promovem o processo de cicatrização e de deposição óssea. Os estudos comparativos entre as superfícies modificadas por métodos de tratamento físicos e/ou químicos, quando comparados com as superfícies maquinadas, demonstram a superioridade das superfícies rugosas em muitos aspectos biomecânicos, sendo hoje um consenso entre a comunidade científica, a superioridade das superfícies modificadas. Independentemente das evidências científicas apontarem para maiores taxas de sucesso associadas ás superfícies tratadas, ainda há um longo caminho a percorrer para colmatar todas as falhas existentes na atualidade. O objetivo deste trabalho foi a realização de uma revisão bibliográfica, através da pesquisa de artigos da Pubmed, B-On, Science Direct, Scielo de forma a aprofundar conhecimentos das vantagens e desvantagens da rugosidade presente na superfície implantar, assim como alertar os médicos dentistas para a importância a ter com a rugosidade em excesso e tentar perceber qual a rugosidade dita ideal. Não se limitou o tempo de pesquisa mas deu-se relevância a referências científicas dos últimos 20 anos, publicados em língua portuguesa e inglesa.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Orthopaedic infections can be polymicrobial existing as a microbiome. Infections often incorporate staphylococcal species, including Staphylococcus aureus. Such infections can lead to life threatening illness and implant failure. Furthermore, biofilm formation on the implant surface can occur, increasing pathogenicity, exacerbating antibiotic resistance and altering antimicrobial mechanism of action. Bacteria change dramatically during the transition to a biofilm growth state: phenotypically; transcriptionally; and metabolically, highlighting the need for research into molecular mechanisms involved in biofilm formation. Metabolomics can provide a tool to analyse metabolic changes which are directly related to the expressed phenotype. Here, we aimed to provide greater understanding of orthopaedic infection caused by S. aureus and biofilm formation on the implant surface. Through metagenome analysis by employing: implant material extraction; DNA extraction; microbial enrichment; and whole genome sequencing, we present a microbiome study of the infected prosthesis to resolve the causative species of orthopaedic hip infection. Results highlight the presence of S. aureus as a primary cause of orthopaedic infection along with Enterococcus faecium and the presence of secondary pathogen Clostridium difficile. Although results were hindered by the presence of host contaminating DNA even after microbial enrichment, conclusions could be made over the potential increased pathogenicity caused by the presence of a secondary pathogen and highlight method and sample preparation considerations when undertaking such a study. Following this finding, studies were focused on an orthopaedic clinical isolate of S. aureus and a metabolome extraction method for staphylococcal biofilms was developed using cell lysis through bead beating and solvent metabolome extraction. The method was found to be reproducible when coupled with liquid chromatography-mass spectrometry (LC-MS) and bioinformatics, allowing for the detection of significant changes in metabolism between planktonic and biofilm cultures to be identified and drug mechanism of actions (MOA) to be studied. Metabolomics results highlight significant changes in a number of metabolic pathways including arginine biosynthesis and purine metabolism between the two cell populations, evidence of S. aureus responding to their changing environment, including oxygen availability and a decrease in pH. Focused investigations on purine metabolism looking for biofilm modulation effects were carried out. Modulation of the S. aureus biofilm phenotype was observed through the addition of exogenous metabolites. Inosine increased biofilm biomass while formycin B, an inosine analogue, showed a dispersal effect and a potential synergistic effect in biofilm dispersal when coupled with gentamycin. Changes in metabolism between planktonic cells and biofilms highlight the requirement for antimicrobial testing to be carried out against planktonic cells and biofilms. Untargeted metabolomics was used to study the MOA of triclosan in S. aureus. The triclosan target and MOA in bacteria has already been characterised, however, questions remain over its effects in bacteria. Although the use of triclosan has come under increasing speculation, its full effects are still largely unknown. Results show that triclosan can induce a cascade of detrimental events in the cell metabolism including significant changes in amino acid metabolism, affecting planktonic cells and biofilms. Results and conclusions provide greater understanding of orthopaedic infections and specifically focus on the S. aureus biofilm, confirming S. aureus as a primary cause of orthopaedic infection and using metabolomic analysis to look at the changing state of metabolism between the different growth states. Metabolomics is a valuable tool for biofilm and drug MOA studies, helping understand orthopaedic infection and implant failure, providing crucial insight into the biochemistry of bacteria for the potential for inferences to be gained, such as the MOA of antimicrobials and the identification of novel metabolic drug targets.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Conventionally, endosseous dental implants have required 3 to 6 months of uninterrupted healing based on observations for dental implants that were characterized by a relatively smooth machined surface. Many studies have since demonstrated that implants with a roughened surface resulted in greater bone apposition, earlier bone contact, and a stronger bond between the implant and the bone, suggesting that implants with roughened surfaces could be loaded earlier than 3 to 6 months. Formal clinical studies confirmed that implants with rough surfaces can have abutments placed and be loaded occlusally as early as 6 weeks postplacement. The purpose of this prospective, human clinical investigation was to evaluate a large number of implants with a specific rough surface (sand-blasted acid-etched [SLA]) placed in everyday practice under routine private-practice conditions. METHODS: A prospective, multicenter, human clinical observational study was initiated with the goal of recruiting a minimum of 500 patients and 800 implants. The implants were to be placed and restored in predominantly private-practice settings around the world. Ninety-two practitioners in 16 countries agreed to participate, and 86 followed the study design. Patients had to be in good health, have sufficient bone to encase the implant, and agree to return for recall appointments. Exclusion criteria included heavy smoking (>10 cigarettes a day) and bone augmentation procedures at the implant site. All implants were two-piece (an abutment was to be placed after 6 weeks of healing) and were characterized by the presence of a transmucosal polished collar. Each implant had an SLA surface. All implants were positioned using a non-submerged (single-stage) surgical technique. Survival and success rates were calculated by life-table analyses. RESULTS: A total of 706 patients were enrolled and 1,406 implants were placed. In the final analyses, 590 patients with 990 implants (70.4% of those enrolled) met all inclusion criteria, including placement of an abutment and provisional restoration within 63 days of surgical placement. The majority of implants were 10 and 12 mm long (78.7%) and were placed in type II and III bone (87%). Seventy-three percent of the implants were placed in the mandible, and 27% were placed in the maxilla. The cumulative survival rate was 99.56% at 3 years and 99.26% at 5 years. The overall success rate was 99.12% at 3 years and 97.38% after 5 years. CONCLUSIONS: Under private-practice conditions, implants with an SLA surface could be placed and restored predictably within 6 to 8 weeks. Data from this prospective, multicenter, human observational study reinforced the results of more formal clinical studies and demonstrated that implants with the SLA surface can be restored in patients in approximately half of the time of conventional healing periods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Topographically and chemically modified titanium implants are recognized to have improved osteogenic properties; however, the molecular regulation of this process remains unknown. This study aimed to determine the microRNA profile and the potential regulation of osteogenic differentiation following early exposure of osteoprogenitor cells to sand-blasted, large-grit acid-etched (SLA) and hydrophilic SLA (modSLA) surfaces. Firstly, the osteogenic characteristics of the primary osteoprogenitor cells were confirmed using ALP activity and Alizarin Red S staining. The effect of smooth (SMO), SLA and modSLA surfaces on the TGF-β/BMP (BMP2, BMP6, ACVR1) and non-canonical WNT/Ca2+ (WNT5A, FZD6) pathways, as well as the integrins ITGB1 and ITGA2, was determined. It was revealed that the modified titanium surfaces could induce the activation of TGF-β/BMP and non-canonical WNT/Ca2+ signaling genes. The expression pattern of microRNAs (miRNAs) related to cell differentiation was evaluated. Statistical analysis of the differentially regulated miRNAs indicated that 35 and 32 miRNAs were down-regulated on the modSLA and SLA surfaces respectively, when compared with the smooth surface (SMO). Thirty-one miRNAs that were down-regulated were common to both modSLA and SLA. There were 10 miRNAs up-regulated on modSLA and nine on SLA surfaces, amongst which eight were the same as observed on modSLA. TargetScan predictions for the down-regulated miRNAs revealed genes of the TGF-β/BMP and non-canonical Ca2+ pathways as targets. This study demonstrated that modified titanium implant surfaces induce differential regulation of miRNAs, which potentially regulate the TGF-β/BMP and WNT/Ca2+ pathways during osteogenic differentiation on modified titanium implant surfaces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was a measure forward in cultivating the scientific basis for an approach to examine clinical procedure in Flapless dental implant surgery. The thesis is based on: the systematic review, retrospective study of flapless implants, and in vivo study on the osseo-integration in osteoporotic rats. Dr Doan investigated "clinical procedures used in dental implant treatment in posterior maxilla using flapless technique". The work has yielded significant contributions to the area of implant flapless surgery and its effects on osteoporotic patients having implants in the posterior maxilla.