184 resultados para IMMUNOASSAYS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The increased awareness and evolved consumer habits have set more demanding standards for the quality and safety control of food products. The production of foodstuffs which fulfill these standards can be hampered by different low-molecular weight contaminants. Such compounds can consist of, for example residues of antibiotics in animal use or mycotoxins. The extremely small size of the compounds has hindered the development of analytical methods suitable for routine use, and the methods currently in use require expensive instrumentation and qualified personnel to operate them. There is a need for new, cost-efficient and simple assay concepts which can be used for field testing and are capable of processing large sample quantities rapidly. Immunoassays have been considered as the golden standard for such rapid on-site screening methods. The introduction of directed antibody engineering and in vitro display technologies has facilitated the development of novel antibody based methods for the detection of low-molecular weight food contaminants. The primary aim of this study was to generate and engineer antibodies against low-molecular weight compounds found in various foodstuffs. The three antigen groups selected as targets of antibody development cause food safety and quality defects in wide range of products: 1) fluoroquinolones: a family of synthetic broad-spectrum antibacterial drugs used to treat wide range of human and animal infections, 2) deoxynivalenol: type B trichothecene mycotoxin, a widely recognized problem for crops and animal feeds globally, and 3) skatole, or 3-methyindole is one of the two compounds responsible for boar taint, found in the meat of monogastric animals. This study describes the generation and engineering of antibodies with versatile binding properties against low-molecular weight food contaminants, and the consecutive development of immunoassays for the detection of the respective compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Epstein-Barr-virus (EBV) aiheuttaa mononukleoosia eli pusutautia, joka ilmenee yleensä murrosiällä tai nuorella aikuisiällä. Mononukleoosissa on tyypilliset nielutulehduksen oireet, minkä takia sitä on vaikea erottaa muiden taudinaiheuttajien aiheuttamista nielutulehduksista. Erotusdiagnostiikan käyttö nielutulehduksessa on oleellista, koska vain Streptokokki-bakteerien aiheuttamat nielutulehdukset vaativat antibioottihoitoa. Akuutin EBV-infektion pikadiagnostiikka perustuu nykyisellään infektion seurauksena muodostuvien heterofiilisten vasta-aineiden mittaamiseen verestä. Niiden mittaamisessa on useita ongelmia, koska useilla lapsilla niitä ei muodostu lainkaan ja vanhemmillakin niitä muodostuu yleensä vasta viikon päästä mononukleoosin oireiden alkamisesta. Mittaamalla EBV:n antigeeneja saataisiin positiivinen testitulos vasta-ainetestiä nopeammin. EBV:lle ei ole kuitenkaan kehitetty antigeeniosoitustestiä todennäköisesti siksi, että EBV:n erittymisen terveiden viruksen kantajien limakalvoille uskotaan olevan ongelma antigeenitestauksessa. Diplomityön tavoitteena oli kehittää akuutin EBV-infektion pikadiagnostiikkaan soveltuva limakalvonäytteestä tehtävä immunometrinen antigeeniosoitustesti. Työssä kehitettiin uusia polyklonaalisia vasta-aineita sekä testattiin kaupallisia vasta-aineita. Vasta-aineiden toimintaa tutkittiin immunomäärityksissä kokonaista EBV:ta ja puhdistettuja proteiiniantigeeneja vastaan. Monoklonaalisten vasta-aineiden kehitys lopetettiin ennen varsinaista tuottoa, koska ensin kehitetyt polyklonaaliset vasta-aineet eivät tunnistaneet natiivia virusta vaan pelkästään immunisointeihin käytetyt rekombinanttiset kohdeproteiinit. Kaupallisista vasta-aineista yhdellä onnistuttiin kehittämään tiettävästi maailman ensimmäinen immunometrinen EBV-antigeeniosoitustesti, jossa saatiin tunnistus sekä natiivilla EBV:lla että puhdistetulla proteiiniantigeenilla. Testin herkkyys proteiiniantigeenilla oli hyvä (4 pM) ja puhdistetulla EBV-virusvalmisteellakin todennäköisesti riittävä (6,2×106 viruspartikkelia/ml) kliiniseen diagnostiikkaan. Testillä ei kuitenkaan saatu suppeasta mononukleoosipotilaiden nielunäyteaineistosta yhtään EBV-positiivista tulosta. Referenssiksi tilatut PCR-testit osoittivat näytteiden EBV-pitoisuuksien olevan liian alhaisia osoitettavaksi kehitetyllä EBV-antigeeniosoitustestillä. PCR-testauksessa mononukleoosipotilaiden nielunäytteistä osoitettujen alhaisten EBV-määrien perusteella spekuloitiin, että olisiko edustavin näytteenottopaikka akuutissa EBV-infektiossa sittenkin nielun sijaan nenänielu. Myös kirjallisuudesta löytyi tälle tukea. EBV-antigeeniosoitustestin osoitettiin toimivan hyvin standardinäyte-materiaalilla. Testikehitysprojektin jatkon kannalta oleellista on kuitenkin vielä selvittää laajemmalla kliinisellä näyteaineistolla, mistä EBV:n antigeeneja pitäisi osoittaa akuutissa EBV-infektiossa ja ovatko niiden pitoisuudet riittävän korkeita.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim was to determine whether follicle growth in cattle is accompanied by changes in levels of inhibin-A (inh-A), activin-A (act-A) and different Mr isofomus of follistatin (FS) in bovine follicular fluid (bFF), reflecting differential roles of these proteins during folliculogenesis. Follcles (n= 146) from 2-20 min diameter were dissected from ovaries of similar to 40 cattle. Immunoassays were used to measure total FS, act-A, inh-A, oestradiol (E) and progesterone (P) levels; immunoblotting was used to quanti, the relative abundance of different FS isoforms. Follicle growth from 2-6 mm was associated with a 6-fold increase in inh-A and 30-fold increase in act-A; FS remained uniformly high from 2-10 turn. From 6-2 min, inh-A remained high while act-A and FS fell 3-fold and 2-fold, respectively. Act-A/FS ratio increased 20-fold from 2-6 mm before falling slightly through to 20 mm. Act-A/inh-A ratio increased 6-fold from 2-6 nun before falling 2-fold from 6 to 17-20 mm. These findings imply a marked increase in relative activin 'tone' around the stage at which dominant follicle,;election occurs. When larger follicles (13-20 mm) were subdivided according to E/P ratio, those with high (> 5) E/P ratio had lower (2-fold; P < 0(.)001) levels of inh-A and act-A in comparison to follicles with low (< 5) E/P ratio, but there were no significant diffierences in FS, act-A/inh-A ratio or act-A/FS ratio. Thus follicle size, but not oestrogenic status, has a major influence on the intrafollicular balance between act-A and its opposing factors, inh-A and FS. Six FS isoforms were detected in bFF (apparent Mr: 65, 41, 37, 35, 33 and 31 kDa) averaging 6, 13, 24, 26 13 and 17% respectively of total FS. During growth from 2-20 mm the proportion of total FS represented by 605, 41 and 37 kDa isoforms increased similar to 2-fold while the proportion represented by the 33 and 31 kDa isoforms decreased by 3-fold and 1(.)6-fold, respectively. Treatment of bovine granulosa cells in vitro with FSH and IGF alone or in combination increased total FS secretion up to 12-fold but did not affect the relative abundance of the five different FS isoforms detected. While the functional significance of the intriguing shift in FS isoform abundance in bFF during follicle development remains to be established, we have shown that a marked increase in intrafollicular activin 'tone' accompanies bovine follicle growth from 3-6 min, corresponding to the stage at which the FSH-dependent follicle selection mechanism operates in this species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extent, causes, and physiological significance of the variation in number of follicles growing during ovarian follicular waves in human beings and cattle are unknown. Therefore, the present study examined the variability and repeatability in numbers of follicles 3 mm or greater in diameter during the follicular waves in bovine estrous cycles, and we determined if the variation in number of follicles during waves was associated with alterations in secretion of FSH, estradiol, inhibin, and insulin-like growth factor I (IGF-I). Dairy cattle were subjected to twice-daily ultrasound analysis to count total number of antral follicles 3 mm or greater in diameter throughout 138 different follicular waves. In another study, blood samples were taken at frequent intervals from cows that consistently had low or very high numbers of follicles during waves and were subjected to immunoassays. Results indicate the following: First, despite an approximately sevenfold variation in number of follicles during waves among animals and marked differences in age, stage of lactation, and season of the year, a very highly repeatable (0.95) number of follicles 3 mm or greater in diameter is maintained during the ovulatory and nonovulatory follicular waves of individuals. Second, variation in number of follicles 3 mm or greater in diameter during waves and the inverse association of number of follicles during waves with FSH are not directly explained by alterations in the patterns of secretion of estradiol, inhibin, or IGF-I. Third, ovarian ultrasound analysis can be used reliably by investigators to identify cattle that consistently have low or high numbers of follicles during waves, thus providing a novel experimental model to determine the causes and physiological significance of the high variation in antral follicle number during follicular waves among single-ovulating species, such as cattle or humans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new concept for rapid and fully portable Prostate Specific Antigen (PSA) measurement, termed “Lab-in-a-Briefcase”, which integrates an affordable microfluidic ELISA platform utilising a melt-extruded fluoropolymer Micro Capillary Film (MCF) containing 10 bore, 200 μm internal diameter capillaries, a disposable multi-syringe aspirator (MSA) plus a sample tray pre-loaded with all required immunoassay reagents, and a portable film scanner for colorimetric signal digital quantitation. Each MSA can perform 10 replicate microfluidic immunoassays on 8 samples, allowing 80measurements to be made in less than 15 minutes based on semi-automated operation and norequirement of additional fluid handling equipment. An assay was optimised for measurement of a clinically relevant range of PSA from 0.9 to 60.0 ng/ml in 15 minutes with CVs in the order of 5% based on intra-assay variability when read using a consumer flatbed film scanner. The PSA assay performance in the MSA remained robust in the presence of undiluted or 1:2 diluted human serum or whole blood, and the matrix effect could simply be overcome by extending sample incubation times. The PSA "Lab-in-a-briefcase" is particularly suited to a low-resource health setting where diagnostic labs and automated immunoassay systems are not accessible, by allowing PSA measurement outside the laboratory using affordable equipment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunodiagnostic microneedles provide a novel way to extract protein biomarkers from the skin in a minimally invasive manner for analysis in vitro. The technology could overcome challenges in biomarker analysis specifically in solid tissue, which currently often involves invasive biopsies. This study describes the development of a multiplex immunodiagnostic device incorporating mechanisms to detect multiple antigens simultaneously, as well as internal assay controls for result validation. A novel detection method is also proposed. It enables signal detection specifically at microneedle tips and therefore may aid the construction of depth profiles of skin biomarkers. The detection method can be coupled with computerised densitometry for signal quantitation. The antigen specificity, sensitivity and functional stability of the device were assessed against a number of model biomarkers. Detection and analysis of endogenous antigens (interleukins 1α and 6) from the skin using the device was demonstrated. The results were verified using conventional enzyme-linked immunosorbent assays. The detection limit of the microneedle device, at ≤10 pg/mL, was at least comparable to conventional plate-based solid-phase enzyme immunoassays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Oxidative modification of low-density lipoprotein (LDL) plays a key role in the pathogenesis of atherosclerosis. LDL(-) is present in blood plasma of healthy subjects and at higher concentrations in diseases with high cardiovascular risk, such as familial hypercholesterolemia or diabetes. Methods: We developed and validated a sandwich ELISA for LDL(-) in human plasma using two monoclonal antibodies against LDL(-) that do not bind to native LDL, extensively copper-oxidized LDL or malondialdehyde-modified LDL. The characteristics of assay performance, such as limits of detection and quantification, accuracy, inter- and intra-assay precision were evaluated. The linearity, interferences and stability tests were also performed. Results: The calibration range of the assay is 0.625-20.0 mU/L at 1: 2000 sample dilution. ELISA validation showed intra- and inter- assay precision and recovery within the required limits for immunoassays. The limits of detection and quantification were 0.423 mU/L and 0.517 mU/L LDL(-), respectively. The intra- and inter- assay coefficient of variation ranged from 9.5% to 11.5% and from 11.3% to 18.9%, respectively. Recovery of LDL(-) ranged from 92.8% to 105.1%. Conclusions: This ELISA represents a very practical tool for measuring LDL(-) in human blood for widespread research and clinical sample use. Clin Chem Lab Med 2008; 46: 1769-75.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The synthesis and study of the chemiluminescence parameters and thermal stability of 1,2-dioxetanes containing a spirofenchyl substituent are reported. Three fenchyl-substituted 1,2-dioxetanes were synthesized by photooxygenation of the corresponding alkenes, obtained by Barton-Kellogg olefination of the readily available (-)-fenchone. The fenchyl-substituted 1,2-dioxetanes showed thermal stabilities similar to those of the corresponding spiroadamantyl-substituted derivatives, although being slightly more labile with respect to unimolecular decomposition than the latter derivatives, which are widely utilized as labels in a great variety of chemiluminescent immunoassays. Fluoride induced decomposition of one triggerable fenchyl 1,2-dioxetane derivative showed kinetic parameters similar to those of the corresponding adamantyl-substituted derivative. The chemiluminescence quantum yields in the one percent range are also similar to that of other widely utilized chemiluminescence systems as the luminol reaction. These results indicate that fenchyl-substituted 1,2-dioxetanes can potentially be utilized as a cheaper alternative to substitute the corresponding spiroadamantyl derivatives in bioanalytical applications. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dosagem do GH no soro é essencial para confirmar ou excluir o seu excesso. Na acromegalia, a ausência de critérios clínicos suficientemente sensíveis para monitorizar o sucesso do tratamento faz com que o GH sérico seja o procedimento de escolha e, para isso, é essencial que a sua dosagem seja realizada de forma confiável, capaz de permitir interpretações uniformes. Vários critérios hormonais têm sido propostos para caracterizar remissão da acromegalia, incluindo níveis séricos de GH randômico inferior a 2,5 μg/l, nadir de GH durante o teste de tolerância oral a glicose inferior a 1,0 μg/l e IGF-I normal para sexo e idade. A importância do tratamento adequado consiste na possibilidade de reverter a mortalidade prematura da acromegalia através da diminuição dos níveis de GH para valores menores que 2,5 μg/l. Com o surgimento de ensaios ultra-sensíveis para medida do GH, tornaram-se necessários critérios mais estritos para determinar cura ou remissão da doença. Nesta revisão, descreveremos aqui as modificações decorrentes da evolução dos ensaios, as conseqüências nos resultados de GH e os pontos de corte propostos na literatura para caracterização da atividade e remissão da acromegalia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

NASCIMENTO, H. G. ; FERNANDES, L. C. ; SOUSA, M. B. C. . Avaliação da fidedignidade dos ensaios de esteróides fecais realizados no Laboratório de Medidas Hormonais do Departamento de Fisiologia da UFRN. Publica , v. 2, p. 39-48, 2006.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enzyme-Linked Immunosorbent Assay (ELISA) has been evaluated by analyzing rich-humic water samples from tropical rivers. The samples were spiked with atrazine at ppb level Different pHs (4 to 9) and humic concentrations (2.5 to 40 mg L-1) were investigated. The assay performance showed a strong dependence on the pH values and amount of humic matter at low atrazine concentration. From all the conditions studied the low pH (pH 4) and high humic substances concentrations (40 mg L-1) showed the greatest influence. The IC50 value to control sample (no humic) diminished from 0.28 nmol L-1 to 0.64 nmol L-1 to humic acid solution. This effect is specially noted for the humic acid fractions, since fulvic acid fractions showed no significant change on the immunoassay results. Additionally, it has been demonstrated that at basic pH the matrix effect produced by the natural Brazilian water sample containing humic substances even at 40 mg L-1 disappears. Therefore, the ELISA method used to determine atrazine, can be employed to determine this pesticide in water samples containing humic substances without prior preparation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enzyme-linked immunosorbent assays (ELISAs) are the most extensively studied types of immunoassay and their application in pesticide residue monitoring is an area with enormous potential for growth. In comparison with classical analytical methods, ELISA methods offer the possibility of highly sensitive, relatively rapid, and cost-effective measurements. This review introduces the general ELISA formats used, focusing on their use in pesticide analysis. Identifying and studying the effects of interferences in immunoassays is an active area of research and we discuss the matrix effects observed in several studies involving e.g. food, crop and environmental samples. The procedures to eliminate the matrix interferences are briefly discussed. (C) 1998 Elsevier B.V. B.V.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)