999 resultados para Electric radiation
Resumo:
Purpose: To determine whether uniform guidelines and training in the stabilization and formation of thermoplastic shells can improve the reproducibility of set-up for Head and Neck cancer patients. Methods and materials: Image based measurements of the planning and treatment positions for 35 head and neck cancer patients undergoing radical radiotherapy were analysed to provide a baseline of the reproducibility of thermoplastic immobilization. Radiation therapists (RT) were surveyed to establish a perception of their confidence in thermoplastic procedures. An evidence based staff training program was created and implemented. Set-up reproduction and staff perception were reviewed to measure the impact of the training program. Results: The mean (SD) 3D vectors of anatomical displacement, measured on the patient images, improved from 4.64 (2.03) for the baseline group compared to 3.02 (1.65) following training (p < 0.01). The proportion of 3D displacements of patient data exceeding 5 mm 3D vector was decreased from 37.1% to 5.7% (p < 0.001) and the 3 mm vector from 85.7% to 42.9% (p < 0.001). The post-training survey scores demonstrated improved confidence in reproducibility of set-up for head and neck patients. Conclusion: The Thermoplastic Shells Training Program has been found to improve the treatment reproducibility for head and neck radiation therapy patients. Uniform guidelines have increased RT confidence in thermoplastic procedures.
Resumo:
We conducted an in-situ X-ray micro-computed tomography heating experiment at the Advanced Photon Source (USA) to dehydrate an unconfined 2.3 mm diameter cylinder of Volterra Gypsum. We used a purpose-built X-ray transparent furnace to heat the sample to 388 K for a total of 310 min to acquire a three-dimensional time-series tomography dataset comprising nine time steps. The voxel size of 2.2 μm3 proved sufficient to pinpoint reaction initiation and the organization of drainage architecture in space and time. We observed that dehydration commences across a narrow front, which propagates from the margins to the centre of the sample in more than four hours. The advance of this front can be fitted with a square-root function, implying that the initiation of the reaction in the sample can be described as a diffusion process. Novel parallelized computer codes allow quantifying the geometry of the porosity and the drainage architecture from the very large tomographic datasets (20483 voxels) in unprecedented detail. We determined position, volume, shape and orientation of each resolvable pore and tracked these properties over the duration of the experiment. We found that the pore-size distribution follows a power law. Pores tend to be anisotropic but rarely crack-shaped and have a preferred orientation, likely controlled by a pre-existing fabric in the sample. With on-going dehydration, pores coalesce into a single interconnected pore cluster that is connected to the surface of the sample cylinder and provides an effective drainage pathway. Our observations can be summarized in a model in which gypsum is stabilized by thermal expansion stresses and locally increased pore fluid pressures until the dehydration front approaches to within about 100 μm. Then, the internal stresses are released and dehydration happens efficiently, resulting in new pore space. Pressure release, the production of pores and the advance of the front are coupled in a feedback loop.
Resumo:
With the progressive exhaustion of fossil energy and the enhanced awareness of environmental protection, more attention is being paid to electric vehicles (EVs). Inappropriate siting and sizing of EV charging stations could have negative effects on the development of EVs, the layout of the city traffic network, and the convenience of EVs' drivers, and lead to an increase in network losses and a degradation in voltage profiles at some nodes. Given this background, the optimal sites of EV charging stations are first identified by a two-step screening method with environmental factors and service radius of EV charging stations considered. Then, a mathematical model for the optimal sizing of EV charging stations is developed with the minimization of total cost associated with EV charging stations to be planned as the objective function and solved by a modified primal-dual interior point algorithm (MPDIPA). Finally, simulation results of the IEEE 123-node test feeder have demonstrated that the developed model and method cannot only attain the reasonable planning scheme of EV charging stations, but also reduce the network loss and improve the voltage profile.
Resumo:
The development of an intelligent plug-in electric vehicle (PEV) network is an important research topic in the smart grid environment. An intelligent PEV network enables a flexible control of PEV charging and discharging activities and hence PEVs can be utilized as ancillary service providers in the power system concerned. Given this background, an intelligent PEV network architecture is first developed, and followed by detailed designs of its application layers, including the charging and discharging controlling system, mobility and roaming management, as well as communication mechanisms associated. The presented architecture leverages the philosophy in mobile communication network buildup
Resumo:
OBJECTIVES: Ecological studies have suggested an inverse relationship between latitude and risks of some cancers. However, associations between solar ultraviolet radiation (UVR) exposure and esophageal cancer risk have not been fully explored. We therefore investigated the association between nevi, freckles, and measures of ambient UVR over the life-course with risks of esophageal cancers. METHODS: We compared estimated lifetime residential ambient UVR among Australian patients with esophageal cancer (330 esophageal adenocarcinoma (EAC), 386 esophago-gastric junction adenocarcinoma (EGJAC), and 279 esophageal squamous cell carcinoma (ESCC)), and 1471 population controls. We asked people where they had lived at different periods of their life, and assigned ambient UVR to each location based on measurements from NASA's Total Ozone Mapping Spectrometer database. Freckling and nevus burden were self-reported. We used multivariable logistic regression models to estimate the magnitude of associations between phenotype, ambient UVR, and esophageal cancer risk. RESULTS: Compared with population controls, patients with EAC and EGJAC were less likely to have high levels of estimated cumulative lifetime ambient UVR (EAC odds ratio (OR) 0.59, 95% confidence interval (CI) 0.35-0.99, EGJAC OR 0.55, 0.34-0.90). We found no association between UVR and risk of ESCC (OR 0.91, 0.51-1.64). The associations were independent of age, sex, body mass index, education, state of recruitment, frequency of reflux, smoking status, alcohol consumption, and H. pylori serostatus. Cases with EAC were also significantly less likely to report high levels of nevi than controls. CONCLUSIONS: These data show an inverse association between ambient solar UVR at residential locations and risk of EAC and EGJAC, but not ESCC.
Resumo:
The problem of MHD natural convection boundary layer flow of an electrically conducting and optically dense gray viscous fluid along a heated vertical plate is analyzed in the presence of strong cross magnetic field with radiative heat transfer. In the analysis radiative heat flux is considered by adopting optically thick radiation limit. Attempt is made to obtain the solutions valid for liquid metals by taking Pr≪1. Boundary layer equations are transformed in to a convenient dimensionless form by using stream function formulation (SFF) and primitive variable formulation (PVF). Non-similar equations obtained from SFF are then simulated by implicit finite difference (Keller-box) method whereas parabolic partial differential equations obtained from PVF are integrated numerically by hiring direct finite difference method over the entire range of local Hartmann parameter, $xi$ . Further, asymptotic solutions are also obtained for large and small values of local Hartmann parameter $xi$ . A favorable agreement is found between the results for small, large and all values of $xi$ . Numerical results are also demonstrated graphically by showing the effect of various physical parameters on shear stress, rate of heat transfer, velocity and temperature.
Resumo:
In this study, natural convection boundary layer flow of thermally radiating fluid along a heated vertical wavy surface is analyzed. Here, the radiative component of heat flux emulates the surface temperature. Governing equations are reduced to dimensionless form, subject to the appropriate transformation. Resulting dimensionless equations are transformed to a set of parabolic partial differential equations by using primitive variable formulation, which are then integrated numerically via iterative finite difference scheme. Emphasis has been given to low Prandtl number fluid. The numerical results obtained for the physical parameters, such as, surface radiation parameter, R, and radiative length parameter, ξ, are discussed in terms of local skin friction and Nusselt number coefficients. Comprehensive interpretation of velocity distribution is also given in the form of streamlines.
Resumo:
The effect of conduction-convection-radiation on natural convection flow of Newtonian optically thick gray fluid, confined in a non-Darcian porous media square cavity is numerically studied. For the gray fluid consideration is given to Rosseland diffusion approximation. Further assuming that (i) the temperature of the left vertical wall is varying linearly with height, (ii) cooled right vertical and top walls and (iii) the bottom wall is uniformly-heated. The governing equations are solved using the Alternate Direct Implicit method together with the Successive Over Relaxation technique. The investigation of the effect of governing parameters namely the Forschheimer resistance (Γ), the Planck constant (Rd), and the temperature difference (Δ), on flow pattern and heat transfer characteristics has been carried out. It was seen that the reduction of flow and heat transfer occurs as the Forschheimer resistance is increased. On the other hand both the strength of flow and heat transfer increases as the temperature ratio, Δ, is increased.
Resumo:
Introduction: Undergraduate students studying the Bachelor of Radiation Therapy at Queensland University of Technology (QUT) attend clinical placements in a number of department sites across Queensland. To ensure that the curriculum prepares students for the most common treatments and current techniques in use in these departments, a curriculum matching exercise was performed. Methods: A cross-sectional census was performed on a pre-determined “Snapshot” date in 2012. This was undertaken by the clinical education staff in each department who used a standardized proforma to count the number of patients as well as prescription, equipment, and technique data for a list of tumour site categories. This information was combined into aggregate anonymized data. Results: All 12 Queensland radiation therapy clinical sites participated in the Snapshot data collection exercise to produce a comprehensive overview of clinical practice on the chosen day. A total of 59 different tumour sites were treated on the chosen day and as expected the most common treatment sites were prostate and breast, comprising 46% of patients treated. Data analysis also indicated that intensity-modulated radiotherapy (IMRT) use is relatively high with 19.6% of patients receiving IMRT treatment on the chosen day. Both IMRT and image-guided radiotherapy (IGRT) indications matched recommendations from the evidence. Conclusion: The Snapshot method proved to be a feasible and efficient method of gathering useful
Resumo:
QUT Bachelor of Radiation Therapy students progress from first visiting a radiation therapy department to graduation and progression into the NPDP over a span of three years. Although there are clear guidelines as to expected competency level post-NPDP, there is still a variety of perceived levels prior to this. Staff and students feedback both suggest that different centres and within centres different staff have differing opinions of these levels. Indeed, many staff members object to the use of the word “competency” for a pre-NPODP undergraduate, preferring the term “achievement”. While it is acknowledged that students progress at different rates, it is vitally important for equity that staff expectations of students at different academic levels are identical. Provision of guidelines for different stages of progression are essential for equitable assessment and most assessments, including the NRTAT are complemented by statements to enable level to be determined. For the University-specific competency assessments some level of consensus between clinical staff is required, especially where students are placed at a large number of different placement sites. Aims The main aim of this initial study is to gauge staff opinions of levels of student progression in order to judge cross-centres consistency. A secondary objective is to evaluate the degree of correlation between staff seniority and perception of student levels. Informal feedback suggests that staff at or just post NPDP level have a different perception of student competency expectations than more senior staff. If these perceptions change with level it will make agreement of guidelines statements more challenging. Study Methods A standard evaluation questionnaire was provided to RT staff participating in ongoing updates to clinical assessment. As part of curriculum development staff were asked to provide anonymous and optional answers to further questions in order to audit current practice. This involved assigning level of student progression to different statements relating to tasks or competencies. After data collation, scores were assigned to level and totals used to rank statements according to perceived student level. Descriptive statistical analysis was used to identify which statements were easier to assign to student level and which were more ambiguous. Further sub-analysis was performed for each category of staff seniority to judge differences in perception. Strength of correlation between seniority and expectation was calculated to confirm or contradict the informal feedback. Results By collating different staff perceptions of competencies for different student levels commonly agreed statements can be used to define achievement level. This presentation outlines the results of the audit including statements that most staff perceived as relevant to a specific student group and statements that staff found to be harder to attribute. Strength of correlation between staff perception and seniority will be outlined where statistically significant.
Resumo:
Aerial Vehicles (UAV) has become a significant growing segment of the global aviation industry. These vehicles are developed with the intention of operating in regions where the presence of onboard human pilots is either too risky or unnecessary. Their popularity with both the military and civilian sectors have seen the use of UAVs in a diverse range of applications, from reconnaissance and surveillance tasks for the military, to civilian uses such as aid relief and monitoring tasks. Efficient energy utilisation on an UAV is essential to its functioning, often to achieve the operational goals of range, endurance and other specific mission requirements. Due to the limitations of the space available and the mass budget on the UAV, it is often a delicate balance between the onboard energy available (i.e. fuel) and achieving the operational goals. This paper presents the development of a parallel Hybrid Electric Propulsion System (HEPS) on a small fixed-wing UAV incorporating an Ideal Operating Line (IOL) control strategy. A simulation model of an UAV was developed in the MATLAB Simulink environment, utilising the AeroSim Blockset and the in-built Aerosonde UAV block and its parameters. An IOL analysis of an Aerosonde engine was performed, and the most efficient (i.e. provides greatest torque output at the least fuel consumption) points of operation for this engine were determined. Simulation models of the components in a HEPS were designed and constructed in the MATLAB Simulink environment. It was demonstrated through simulation that an UAV with the current HEPS configuration was capable of achieving a fuel saving of 6.5%, compared to the ICE-only configuration. These components form the basis for the development of a complete simulation model of a Hybrid-Electric UAV (HEUAV).
Resumo:
As the use of fiducial markers (FMs) for the localisation of the prostate during external beam radiation therapy (EBRT) has become part of routine practice, radiation therapists (RTs) have become increasingly responsible for online image interpretation. The aim of this investigation was to quantify the limits of agreement (LoA) between RTs when localising to FMs with orthogonal kilovoltage (kV) imaging. Methods Six patients receiving prostate EBRT utilising FMs were included in this study. Treatment localisation was performed using kV imaging prior to each fraction. Online stereoscopic assessment of FMs, performed by the treating RTs, was compared with the offline assessment by three RTs. Observer agreement was determined by pairwise Bland-Altman analysis. Results Stereoscopic analysis of 225 image pairs was performed online at the time of treatment, and offline by three RT observers. Eighteen pairwise Bland-Altman analyses were completed to assess the level of agreement between observers. Localisation by RTs was found to be within clinically acceptable 95% LoAs. Conclusions Small differences between RTs, in both the online and offline setting, were found to be within clinically acceptable limits. RTs were able to make consistent and reliable judgements when matching FMs on planar kV imaging.
Resumo:
Two different morphologies of nanotextured molybdenum oxide were deposited by thermal evaporation. By measuring their field emission (FE) properties, an enhancement factor was extracted. Subsequently, these films were coated with a thin layer of Pt to form Schottky contacts. The current-voltage (I-V) characteristics showed low magnitude reverse breakdown voltages, which we attributed to the localized electric field enhancement. An enhancement factor was obtained from the I-V curves. We will show that the enhancement factor extracted from the I-V curves is in good agreement with the enhancement factor extracted from the FE measurements.
Resumo:
Background Individual exposure to ultraviolet radiation (UVR) is challenging to measure, particularly for diseases with substantial latency periods between first exposure and diagnosis of outcome, such as cancer. To guide the choice of surrogates for long-term UVR exposure in epidemiologic studies, we assessed how well stable sun-related individual characteristics and environmental/meteorological factors predicted daily personal UVR exposure measurements. Methods We evaluated 123 United States Radiologic Technologists subjects who wore personal UVR dosimeters for 8 hours daily for up to 7 days (N = 837 days). Potential predictors of personal UVR derived from a self-administered questionnaire, and public databases that provided daily estimates of ambient UVR and weather conditions. Factors potentially related to personal UVR exposure were tested individually and in a model including all significant variables. Results The strongest predictors of daily personal UVR exposure in the full model were ambient UVR, latitude, daily rainfall, and skin reaction to prolonged sunlight (R2 = 0.30). In a model containing only environmental and meteorological variables, ambient UVR, latitude, and daily rainfall were the strongest predictors of daily personal UVR exposure (R2 = 0.25). Conclusions In the absence of feasible measures of individual longitudinal sun exposure history, stable personal characteristics, ambient UVR, and weather parameters may help estimate long-term personal UVR exposure.
Resumo:
Background: Despite the technologic advances, radiation dermatitis is still a prevalent and distressing symptom in patients with cancer undergoing radiotherapy. Systematic reviews (SRs) are regarded as level I evidence providing direction for clinical practice and guidelines. This overview aims to provide a critical appraisal of SRs published on interventions for the prevention/management of radiation dermatitis. Methodology: We searched the following electronic databases: MEDLINE, CINAHL, EMBASE, and the Cochrane Library (up to Feb 2012). We also hand-searched reference lists of potentially eligible articles and a number of key journals in the area. Two authors screened all potential articles and included eligible SRs. Two authors critically appraised and extracted key findings from the included reviews using the “A Measurement Tool to Assess Systematic Reviews” (AMSTAR). Results: Of 1837 potential titles, six SRs were included. A number of interventions have been reported to be potentially beneficial for managing radiation dermatitis. Interventions evaluated in these reviews included skin care advice, steroidal/non-steroidal topical agents, systematic therapies, modes of radiation delivery, and dressings. However, all the included SRs reported that there is insufficient evidence supporting any single effective intervention. The methodological quality of the included studies varied, and methodological shortfalls in these reviews may create biases to the overall results or recommendations for clinical practice. Conclusions and implications: An up-to-date high quality SR in preventing/managing radiation dermatitis is needed to guide practice and direction for future research. Clinicians or guideline developers are recommended to critically evaluate the information of SRs in their decision making.