927 resultados para Electric load management
Resumo:
BACKGROUND Symptoms associated with pes planovalgus or flatfeet occur frequently, even though some people with a flatfoot deformity remain asymptomatic. Pes planovalgus is proposed to be associated with foot/ankle pain and poor function. Concurrently, the multifactorial weakness of the tibialis posterior muscle and its tendon can lead to a flattening of the longitudinal arch of the foot. Those affected can experience functional impairment and pain. Less severe cases at an early stage are eligible for non-surgical treatment and foot orthoses are considered to be the first line approach. Furthermore, strengthening of arch and ankle stabilising muscles are thought to contribute to active compensation of the deformity leading to stress relief of soft tissue structures. There is only limited evidence concerning the numerous therapy approaches, and so far, no data are available showing functional benefits that accompany these interventions. METHODS After clinical diagnosis and clarification of inclusion criteria (e.g., age 40-70, current complaint of foot and ankle pain more than three months, posterior tibial tendon dysfunction stage I & II, longitudinal arch flattening verified by radiography), sixty participants with posterior tibial tendon dysfunction associated complaints will be included in the study and will be randomly assigned to one of three different intervention groups: (i) foot orthoses only (FOO), (ii) foot orthoses and eccentric exercise (FOE), or (iii) sham foot orthoses only (FOS). Participants in the FOO and FOE groups will be allocated individualised foot orthoses, the latter combined with eccentric exercise for ankle stabilisation and strengthening of the tibialis posterior muscle. Participants in the FOS group will be allocated sham foot orthoses only. During the intervention period of 12 weeks, all participants will be encouraged to follow an educational program for dosed foot load management (e.g., to stop activity if they experience increasing pain). Functional impairment will be evaluated pre- and post-intervention by the Foot Function Index. Further outcome measures include the Pain Disability Index, Visual Analogue Scale for pain, SF-12, kinematic data from 3D-movement analysis and neuromuscular activity during level and downstairs walking. Measuring outcomes pre- and post-intervention will allow the calculation of intervention effects by 3×3 Analysis of Variance (ANOVA) with repeated measures. DISCUSSION The purpose of this randomised trial is to evaluate the therapeutic benefit of three different non-surgical treatment regimens in participants with posterior tibial tendon dysfunction and accompanying pes planovalgus. Furthermore, the analysis of changes in gait mechanics and neuromuscular control will contribute to an enhanced understanding of functional changes and eventually optimise conservative management strategies for these patients. TRIAL REGISTRATION ClinicalTrials.gov Protocol Registration System: ClinicalTrials.gov ID NCT01839669.
Resumo:
An ED-tether mission to Jupiter is presented. A bare tether carrying cathodic devices at both ends but no power supply, and using no propellant, could move 'freely' among Jupiter's 4 great moons. The tour scheme would have current naturally driven throughout by the motional electric field, the Lorentz force switching direction with current around a 'drag' radius of 160,00 kms, where the speed of the jovian ionosphere equals the speed of a spacecraft in circular orbit. With plasma density and magnetic field decreasing rapidly with distance from Jupiter, drag/thrust would only be operated in the inner plasmasphere, current being near shut off conveniently in orbit by disconnecting cathodes or plugging in a very large resistance; the tether could serve as its own power supply by plugging in an electric load where convenient, with just some reduction in thrust or drag. The periapsis of the spacecraft in a heliocentric transfer orbit from Earth would lie inside the drag sphere; with tether deployed and current on around periapsis, magnetic drag allows Jupiter to capture the spacecraft into an elliptic orbit of high eccentricity. Current would be on at succesive perijove passes and off elsewhere, reducing the eccentricity by lowering the apoapsis progressively to allow visits of the giant moons. In a second phase, current is on around apoapsis outside the drag sphere, rising the periapsis until the full orbit lies outside that sphere. In a third phase, current is on at periapsis, increasing the eccentricity until a last push makes the orbit hyperbolic to escape Jupiter. Dynamical issues such as low gravity-gradient at Jupiter and tether orientation in elliptic orbits of high eccentricity are discussed.
Resumo:
A procedure for measuring the overheating temperature (ΔT ) of a p-n junction area in the structure of photovoltaic (PV) cells converting laser or solar radiations relative to the ambient temperature has been proposed for the conditions of connecting to an electric load. The basis of the procedure is the measurement of the open-circuit voltage (VO C ) during the initial time period after the fast disconnection of the external resistive load. The simultaneous temperature control on an external heated part of a PV module gives the means for determining the value of VO C at ambient temperature. Comparing it with that measured after switching OFF the load makes the calculation of ΔT possible. Calibration data on the VO C = f(T ) dependences for single-junction AlGaAs/GaAs and triple-junction InGaP/GaAs/Ge PV cells are presented. The temperature dynamics in the PV cells has been determined under flash illumination and during fast commutation of the load. Temperature measurements were taken in two cases: converting continuous laser power by single-junction cells and converting solar power by triple-junction cells operating in the concentrator modules.
Resumo:
El objetivo del presente trabajo es el diseño de una máquina para ensayos de Creep, con capacidad de aplicar carga variable. Se busca una máquina liviana, desmontable y fácilmente transportable entre laboratorios. El diseño de la máquina parte de una ingeniería básica, pasando por una etapa de detalle y finalizando en la fabricación y montaje de la misma. Se incluye en el diseño un sistema de adquisición y control de carga. Se diseñó y construyó una máquina accionada por resorte capaz de aplicar 5 kN. Se evalúa su respuesta ante distintos programas de carga. El control de carga es capaz de seguir referencias con evolución suave en el tiempo sin mayores dificultades y mantener la carga constante durante intervalos largos de tiempo. La adquisición de datos se realiza mediante un módulo QuantumX y transductores de desplazamiento y carga HBM.
Resumo:
El objetivo del presente trabajo es el diseño de una máquina para ensayos de Creep, con capacidad de aplicar carga variable. Se busca una máquina liviana, desmontable y fácilmente transportable entre laboratorios. El diseño de la máquina parte de una ingeniería básica, pasando por una etapa de detalle y finalizando en la fabricación y montaje de la misma. Se incluye en el diseño un sistema de adquisición y control de carga. Se diseñó y construyó una máquina accionada por resorte capaz de aplicar 5 kN. Se evalúa su respuesta ante distintos programas de carga. El control de carga es capaz de seguir referencias con evolución suave en el tiempo sin mayores dificultades y mantener la carga constante durante intervalos largos de tiempo. La adquisición de datos se realiza mediante un módulo QuantumX y transductores de desplazamiento y carga HBM.
Resumo:
Tämän työn tavoitteena on skenaarioiden avulla luoda pitkän aikavälin alueellinen sähkökuormien kehitysennuste Rovaniemen Verkko Oy:lle. Pitkän aikavälin kuormitusennusteet ovat välttämättömiä verkon kehittämisen pohjalle, jotta verkko voidaan mitoittaa vastaamaan kuormitusta pitkälle tulevaisuuteen tekniset ja taloudelliset vaatimukset huomioiden. Kuormitusennusteen onkin jatkossa tarkoitus toimia apuvälineenä verkon strategisessa kehittämisessä. Pohjana kuormitusennusteissa on tilastokeskuksen ja Rovaniemen kaupungin väestö- ja työpaikkaennusteet. Väestöennusteiden ja erilaisten rakentamistilastoiden avulla arvioidaan uudisrakentamisen määrä tulevaisuudessa. Uudisrakentamisen kuormitusvaikutuksiin päästään työssä määritettyjen paikallisten ja rakennustyyppikohtaisten sähkön ominaiskulutuksien avulla. Kuormituksien alueellinen sijoittautuminen arvioidaan kaavoituksen ja kaupungin maankäytön toteuttamisohjelman avulla. Työssä tutkitaan myös tulevaisuudessa sähkönkäytössä tapahtuvien useiden muutosten vaikutusta alueelliseen kuormitukseen. Näitä muutoksia ovat muun muassa sähköautojen, hajautetun tuotannon, lämpöpumppujen ja kysynnän jouston lisääntyminen. Myös rakennusten jatkuvasti parantuva energiatehokkuus aiheuttaa muutoksia sähkön kulutukseen.
Resumo:
The large penetration of intermittent resources, such as solar and wind generation, involves the use of storage systems in order to improve power system operation. Electric Vehicles (EVs) with gridable capability (V2G) can operate as a means for storing energy. This paper proposes an algorithm to be included in a SCADA (Supervisory Control and Data Acquisition) system, which performs an intelligent management of three types of consumers: domestic, commercial and industrial, that includes the joint management of loads and the charge/discharge of EVs batteries. The proposed methodology has been implemented in a SCADA system developed by the authors of this paper – the SCADA House Intelligent Management (SHIM). Any event in the system, such as a Demand Response (DR) event, triggers the use of an optimization algorithm that performs the optimal energy resources scheduling (including loads and EVs), taking into account the priorities of each load defined by the installation users. A case study considering a specific consumer with several loads and EVs is presented in this paper.
Resumo:
Electric vehicle (EV) batteries tend to have accelerated degradation due to high peak power and harsh charging/discharging cycles during acceleration and deceleration periods, particularly in urban driving conditions. An oversized energy storage system (ESS) can meet the high power demands; however, it suffers from increased size, volume and cost. In order to reduce the overall ESS size and extend battery cycle life, a battery-ultracapacitor (UC) hybrid energy storage system (HESS) has been considered as an alternative solution. In this work, we investigate the optimized configuration, design, and energy management of a battery-UC HESS. One of the major challenges in a HESS is to design an energy management controller for real-time implementation that can yield good power split performance. We present the methodologies and solutions to this problem in a battery-UC HESS with a DC-DC converter interfacing with the UC and the battery. In particular, a multi-objective optimization problem is formulated to optimize the power split in order to prolong the battery lifetime and to reduce the HESS power losses. This optimization problem is numerically solved for standard drive cycle datasets using Dynamic Programming (DP). Trained using the DP optimal results, an effective real-time implementation of the optimal power split is realized based on Neural Network (NN). This proposed online energy management controller is applied to a midsize EV model with a 360V/34kWh battery pack and a 270V/203Wh UC pack. The proposed online energy management controller effectively splits the load demand with high power efficiency and also effectively reduces the battery peak current. More importantly, a 38V-385Wh battery and a 16V-2.06Wh UC HESS hardware prototype and a real-time experiment platform has been developed. The real-time experiment results have successfully validated the real-time implementation feasibility and effectiveness of the real-time controller design for the battery-UC HESS. A battery State-of-Health (SoH) estimation model is developed as a performance metric to evaluate the battery cycle life extension effect. It is estimated that the proposed online energy management controller can extend the battery cycle life by over 60%.
Resumo:
The increasing integration of Renewable Energy Resources (RER) and the role of Electric Energy Storage (EES) in distribution systems has created interest in using energy management strategies. EES has become a suitable resource to manage energy consumption and generation in smart grid. Optimize scheduling of EES can also maximize retailer’s profit by introducing energy time-shift opportunities. This paper proposes a new strategy for scheduling EES in order to reduce the impact of electricity market price and load uncertainty on retailers’ profit. The proposed strategy optimizes the cost of purchasing energy with the objective of minimizing surplus energy cost in hedging contract. A case study is provided to demonstrate the impact of the proposed strategy on retailers’ financial benefit.
Resumo:
Designing a heat sink based on a phase change material (PCM) under cyclic loading is a critical issue. For cyclic operation, it is required that the fraction of the PCM melting during the heating cycle should completely resolidify during the cooling period, so that that thermal storage unit can be operated for an unlimited number of cycles. Accordingly, studies are carried out to find the parameters influencing the behavior of a PCM under cyclic loading. A number of parameters are identified in the process, the most important ones being the duty cycle and heat transfer coefficient (h) for cooling. The required h or the required cooling period for complete resolidification for infinite cyclic operation of a conventional PCM-based heat sink is found to be very high and unrealistic with air cooling from the surface. To overcome this problem, the conventional design is modified where h and the area exposed to heat transfer can be independently controlled. With this arrangement, the enhanced area provided for cooling keeps h within realistic limits. Analytical investigation is carried out to evaluate the thermal performance of this modified PCM-based heat sink in comparison to those with conventional designs. Experiments are also performed on both the conventional and the modified PCM-based heat sinks to validate the new findings.
Resumo:
The international introduction of electric vehicles (EVs) will see a change in private passenger car usage, operation and management. There are many stakeholders, but currently it appears that the automotive industry is focused on EV manufacture, governments and policy makers have highlighted the potential environmental and job creation opportunities while the electricity sector is preparing for an additional electrical load on the grid system. If the deployment of EVs is to be successful the introduction of international EV standards, universal charging hardware infrastructure, associated universal peripherals and user-friendly software on public and private property is necessary. The focus of this paper is to establish the state-of-the-art in EV charging infrastructure, which includes a review of existing and proposed international standards, best practice and guidelines under consideration or recommendation.
Resumo:
Dwindling fossil fuel resources and pressures to reduce greenhouse gas (GHG) emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is that supply instantaneously meets demand and that robust operating standards are maintained to ensure a consistent supply of high quality electricity to end-users. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management (DSM) with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating (EWH) has been studied previously, particularly at the domestic level to provide load control, peak shave and to benefit end-users financially with lower bills, particularly in vertically integrated monopolies. In this paper, a continuous Direct Load Control (DLC) EWH algorithm is applied in a liberalized market environment using actual historical electricity system and market data to examine the potential energy savings, cost reductions and electricity system operational improvements.
Resumo:
Dwindling fossil fuel resources and pressures to reduce greenhouse gas emissions will result in a more diverse range of generation portfolios for future electricity systems. Irrespective of the portfolio mix the overarching requirement for all electricity suppliers and system operators is to instantaneously meet demand, to operate to standards and reduce greenhouse gas emissions. Therefore all electricity market participants will ultimately need to use a variety of tools to balance the power system. Thus the role of demand side management with energy storage will be paramount to integrate future diverse generation portfolios. Electric water heating has been studied previously, particularly at the domestic level to provide load control, peak shave and to bene?t end-users ?nancially with lower bills, particularly in vertically integrated monopolies. In this paper a number of continuous direct load control demand response based electric water heating algorithms are modelled to test the effectiveness of wholesale electricity market signals to study the system bene?ts. The results are compared and contrasted to determine which control algorithm showed the best potential for energy savings, system marginal price savings and wind integration.
Resumo:
This study characterizes the domestic loads suitable to participate in the load participation scheme to make the power system more carbon and economically efficient by shifting the electricity demand profile towards periods when there is plentiful renewable in-feed.
A series of experiments have been performed on a common fridge-freezer, both completely empty and half full. The results presented are ambient temperature, temperature inside the fridge, temperature inside the drawer of the fridge, temperature inside the freezer, thermal time constants, power consumption and electric energy consumed.
The thermal time constants obtained clearly demonstrate the potential of such refrigeration load for Smart Customer Load Participation.