991 resultados para ENVIRONMENTAL-SAMPLES


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Perfluoro and sulfonated ion-exchange polymers are recognized as a very useful material for various mechanistic studies and applications in electrochemistry. These polymers are characterized by high equivalent weights and by a low number of ion-exchange sites interposed between long organic chains. The solubility enables a preparation of stable polyelectrolyte films on the electrode surface. Examples of the determination of trace metals and organic componds in real environmental samples are presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The toxicity of the major As species present in the environment justifies the effort for quantifying the element in environmental organic samples, which can vary from animal and vegetal tissues to coal and industrial residues. This paper comments about the applicability of the O2 bomb digestion, as a general procedure for all environmental organic materials. A rapid and straightforward method is suggested, which consists in burning the sample in the bomb at high O2 pressure, dissolving the vapours in diluted HNO3 and determining As in the resulting solution by atomic absorption spectrometry with electrothermal atomization. The method was applied to certified materials and plant samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The development of liquid chromatography-mass spectrometric (LC-MS) techniques in the last few decades has made possible the analysis of trace amounts of analytes from complex matrices. With LC, the analytes of interest can be separated from each other as well as from the interfering matrix, after which they can be reliably identified thanks to the sensitivity and specificity of MS. LC-MS has become an irreplaceable tool for many applications, ranging from the analysis of proteins or pharmaceuticals in biological fluids to the analysis of toxic substances in environmental samples. In different segments of Brazilian Industry mass spectrometry has an important role, e.g. in the pharmaceutical industry in the development of generic formulations, contributing to the growth of Industry and social inclusion. However, the Brazilian chemists until this moment don't have an effective role in this new segment of the analytical chemistry in Brazil. The present paper shows the actual scenario for mass spectrometry in the pharmaceutical industry, emphasizing the need of a revision of graduation courses to attend the needs of this growing market.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work a simple and sensitive procedure to extract organic mercury from water and sediment samples, using methylene chloride in acidic media followed by CVAFS quantification has been developed. The method was evaluated for possible interferents, using different inorganic mercury species and humic acid, no effects being observed. The detection limit for organic mercury was 160 pg and 396 pg for water and sediment samples respectively. The accuracy of the method was evaluated using a certified reference material of methylmercury (BCR-580, estuarine sediment). Recovery tests using methylmercury as surrogate spiked with 1.0 up to 30.0 ng L-1 ranged from 90 up to 109% for water samples, whereas for sediments, recoveries ranged from 57 up to 97%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents the VALIDATION SPREADSHEET, a public domain tool that can be used to evaluate the figures of merit for univariate analytical methods. A real example of BTEX determination in environmental samples is included to illustrate its use. The spreadsheet has been developed for Excel® and Open Office®, and is available on the internet at http//lqta.iqm.unicamp.br.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L-1 were tested with percentage recoveries varying from 89 to 113%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The construction of a low cost mini sensor containing a bismuth-film electrode (BiFE), as work electrode, a silver electrode as pseudo reference electrode, and copper as counter electrode is proposed. The application of this mini sensor using a low cost electrochemical cell for in loco voltammetric determinations of inorganic and organic analytes is also described.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The need for automated analyzers for industrial and environmental samples has triggered the research for new and cost-effective strategies of automation and control of analytical systems. The widespread availability of open-source hardware together with novel analytical methods based on pulsed flows have opened the possibility of implementing standalone automated analytical systems at low cost. Among the areas that can benefit from this approach are the analysis of industrial products and effluents and environmental analysis. In this work, a multi-pumping flow system is proposed for the determination of phosphorus in effluents and polluted water samples. The system employs photometric detection based on the formation of molybdovanadophosphoric acid, and the fluidic circuit is built using three solenoid micropumps. The detection is implemented with a low cost LED-photodiode photometric detection system and the whole system is controlled by an open-source Arduino Uno microcontroller board. The optimization of the timing to ensure the color development and the pumping cycle is discussed for the proposed implementation. Experimental results to evaluate the system behavior are presented verifying a linear relationship between the relative absorbance and the phosphorus concentrations for levels as high as 50 mg L-1.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Some models of ion-selective electrodes (ISE) and other methods have been elaborated, to quantify nitrate levels in environmental samples (water, fruits, vegetables and others), using direct potentiometry

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The ligand di-2-pyridyl ketone benzoylhydrazone (DPKBH) is widely used for the determination of transition metal ions in environmental samples. Due to its low solubility in water it is used in aqueous-ethanol (1:1) solvent and for higher sensitivity the pH must be properly adjusted. The properties of DPKBH solutions must be known at different ethanol-water percentages in order to achieve higher sensitivity and/or selectivity for metal analysis. The acid-base behavior of this reagent in aqueous-ethanol solvent and the dissociation/ionization constants (pK1 and pK2) of DPKBH have been determined in different aqueous-ethanol solvent mixtures (10, 20, 30 and 50 % V/V of ethanol) from potentiometric titrations at 25.0 ± 0.1° C. As the amount of ethanol increases from 10 to 30% the pK1 and pK2 values increased, but they decreased in 50% of the organic solvent. The results are correlated with the medium composition and its effects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Att övervaka förekomsten av giftiga komponenter i naturliga vattendrag är nödvändigt för människans välmående. Eftersom halten av föroreningar i naturens ekosystem bör hållas möjligast låg, pågår en ständig jakt efter kemiska analysmetoder med allt lägre detektionsgränser. I dagens läge görs miljöanalyser med dyr och sofistikerad instrumentering som kräver mycket underhåll. Jonselektiva elektroder har flera goda egenskaper som t.ex. bärbarhet, låg energiförbrukning, och dessutom är de relativt kostnadseffektiva. Att använda jonselektiva elektroder vid miljöanalyser är möjligt om deras känslighetsområde kan utvidgas genom att sänka deras detektionsgränser. För att sänka detektionsgränsen för Pb(II)-selektiva elektroder undersöktes olika typer av jonselektiva membran som baserades på polyakrylat-kopolymerer, PVC och PbS/Ag2S. Fast-fas elektroder med membran av PbS/Ag2S är i allmänhet enklare och mer robusta än konventionella elektroder vid spårämnesanalys av joniska föroreningar. Fast-fas elektrodernas detektionsgräns sänktes i detta arbete med en nyutvecklad galvanostatisk polariseringsmetod och de kunde sedan framgångsrikt användas för kvantitativa bestämningar av bly(II)-halter i miljöprov som hade samlats in i den finska skärgården nära tidigare industriområden. Analysresultaten som erhölls med jonselektiva elektroder bekräftades med andra analytiska metoder. Att sänka detektionsgränsen m.hj.a. den nyutvecklade polariseringsmetoden möjliggör bestämning av låga och ultra-låga blyhalter som inte kunde nås med klassisk potentiometri. Den verkliga fördelen med att använda dessa blyselektiva elektroder är möjligheten att utföra mätningar i obehandlade miljöprov trots närvaron av fasta partiklar vilket inte är möjligt att göra med andra analysmetoder. Jag väntar mig att den nyutvecklade polariseringsmetoden kommer att sätta en trend i spårämnesanalys med jonselektiva elektroder.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objectives of this study were to isolate Klebsiella pneumoniae from different sources in three dairy cattle herds, to use the pulsed-field gel electrophoresis (PFGE) to measure genotypic similarities between isolates within a dairy herd, to verify the production of extended-spectrum β-lactamases (ESBLs) by the double-disk synergy test (DDST), and to use the PCR to detect the main ESBLs subgroups genes. Three dairy farms were selected based on previous mastitis outbreaks caused by K. pneumoniae. Milk samples were collected from lactating cows and from the bulk tank. Swabs were performed in different locations, including milking parlors, waiting room, soil, animal's hind limbs and rectum. K. pneumoniae was isolated from 27 cases of intramammary infections (IMI) and from 41 swabs. For farm A isolates from IMI and bulk tank were considered of the same PGFE subtype. One isolate from a bulk tank, three from IMI cases and four from environmental samples were positive in the DDST test. All eight DDST positive isolates harbored the bla shv gene, one harbored the bla tem gene, and three harbored the bla ctx-m gene, including the bulk tank isolate. Our study confirms that ESBL producing bacteria is present in different locations in dairy farms, and may be responsible for IMI. The detection of ESBLs on dairy herds could be a major concern for both public and animal health.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This investigation of geochemistry and mineralogy of heavy metals in fine grained (<63^m) sediment of the Welland River was imdertaken to: 1) describe metal dispersion patterns relative to a source, identify minerals forming and existing at the outfall region and relate sediment particle size to chemistry; 2) to delineate sample handling, preparation and evaluate, modify and develop analytical methods for heavy metal analysis of complex environmental samples. Ajoint project between Brock University and Geoscience Laboratories was initiated to test a contaminated site of the Welland River at the base of Atlas Speciality Steels Co. Methods were developed and utilized for particle size separation and two acid extraction techniques: 1) Partial extraction; 2) Total extraction. The mineralogical assessment identified calcite, dolomite, quartz and clays. These minerals are typical of the carbonate-shale rock basement of the Niagara Peninsula. Minerals such as, mullite and ferrocolumbite were found at the outfall region. These are not typical of the local geology and are generally associated with industrial pollutants. Partial and total extraction techniques were used to characterize the sediments based on chemical distribution, elemental behaviour and analytical differences. The majority of elements were lower in concentration in the partial extraction technique; suggesting these elements are bound in an acid extractable phase (exchangeable, organic and carbonate phases). The total extraction technique yielded higher elemental concentrations taking difficult oxides and silicates into solution. Geochemical analyses of grain size separates revealed that heavy metal (Co, Ni, V, Mn, Fe, Ba) concentrations did not increase with decreasing grain size. This is a function of the anthropogenic mill scale input into the river. The background elements (Sc, Y, Sr, Mg, Al and Ti) showed an increase in concentration to the finest grain size suggesting that it is directly related to the local mineralogy and geology. Dispersion patterns ofmetals fall into two distinct categories: 1) the heavy metals (Co, Cu, Ni, Zn, V and Cr), and 2) the background elements (Be, Sc, Y, Sr, Al and Ti). The heavy metals show a marked increase in the outfall region, while the background elements show a significant decrease at the outfall. This pattern is attributed to a "dilution effect" ofthe natural sediments by the anthropogenic mill scale sediments. Multivariant statistical analysis and correlation coefficient matrix results clearly support these results and conclusions. These results indicate the outfall region ofthe Welland River is highly contaminated with to heavy metals from the industrialized area of Welland. A short distance downstream, the metal concentrations return to baseline geochemical levels. It appears, contaminants rapidly come out of suspension and are deposited in close proximity to the source. Therefore, it is likely that dredging the sediment from the river may cause resuspension of contaminated sediments, but may not distribute the sediment as far as initially anticipated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

It has been proposed that phages can be used commercially as a biopesticide for the control of fire blight caused by the phytopathogen Erwinia amylovora. The aim of these studies was to investigate two common bacterial resistance mechanisms, lysogeny and exopolysaccharide production and their influence on phage pathogenesis. A multiplex real-time PCR protocol was designed to monitor and quantify Podoviridae and Myoviridae phages. This protocol is compatible with known E. amylovora and Pantoea agglomerans rtPCR primers/probes which allowed simultaneous study of both phage and bacterial targets. Using in vitro positive phage selection, bacteriophage insensitive derivatives were isolated within sensitive populations of E. amylovora. Prophage screening with real-time PCR and mitomycin C induction determined that the insensitive derivatives harboured the temperate Podoviridae phage ΦEaTlOO. Lysogenic conversion resulted in resistance to secondary homologous phage infections. Prophage screening of environmental samples of E. amylovora and P. agglomerans collected from various locations in Canada, United States and Europe did not demonstrate lysogeny. Therefore, lysogeny is rare or absent while these bacterial species reside on the plant. Recombineering was used to construct exopolysaccharide deficient E. amylovora mutants. The EPS amylovoran mutants became resistant to Podoviridae and certain Siphoviridae phages. Increasing amylovoran production increased phage population growth, presumably by increasing the total number of bacterial cell surface receptors which promoted increased phage infections. In contrast, amylovoran did not playa role in Myoviridae infections, nor did production of the EPS levan for any phage pathogenesis.