966 resultados para Disposable equipment
Resumo:
Abstract The present work describes setting up a laboratory unit for supercritical fluid extraction. In addition to its construction, a survey of cost was done to compare the cost of the homemade unit with that of commercial units. The equipment was validated using an extraction of annatto seeds’ oil, and the extraction and fractionation of fennel oil were used to validate the two separators; for both systems, the solvent was carbon dioxide. The chemical profiles of annatto and fennel extracts were assessed using thin layer chromatography; the images of the chromatographic plates were processed using the free ImageJ software. The cost survey showed that the homemade equipment has a very low cost (~US$ 16,000) compared to commercial equipment. The extraction curves of annatto were similar to those obtained in the literature (yield of 3.8% oil). The separators were validated, producing both a 2.5% fraction of fennel seed extract rich in essential oils and another extract fraction composed mainly of oleoresins. The ImageJ software proved to be a low-cost tool for obtaining an initial evaluation of the chemical profile of the extracts.
Resumo:
The growth of the food packaging industry has raised more interest in bio-based fibre packing. The use of petroleum based packages is unfriendly to the environment while bio-based is a sustainable option for food packing. In this Master Thesis the aim was to discover how the press forming machineries runnability is affected by parameters of the press and how it also affects formability of paperboard trays. Familiarisation of the working operation parameters was done with the KAMA ST 75 flat-bed die cutting machine and the VP3-70 mould press. Some small test runs of moulding trays where done to get acquainted to the adjustment parameters of the machines. Literature study was done on how paperboards physical properties react to the forces applied during press forming. The study of what kind of defects to the paperboard tray might occur during forming process and the causes for these defects. Also how the parameters of the press forming machine affects formability of the tray. Maintenance procedures was done to the press forming machine to enhance the reliably of production process. Tool alignment measurement was done to determine proper alignment. Laboratory test of the physical properties of the test material was done to find any connection to how the test material performs in press forming. An evaluation criterion was made to evaluate the dimensions and defects of the tray. From the test result a conclusion can be drawn on how the parameters of the press forming process affect the paperboard material. Based on the results the adjustment the parameters of moulding machines to the mechanical properties of paperboard it is possible to produce high quality fibre passed trays for the food packaging industry.
Resumo:
Electrical road vehicles were common at the begin of the 20th century but internal combustion engines took a victory from electrical motors in road vehicles. The acknowledgement of the environment, and the price and the availability of the crude oil are reasons for the comeback of the electrical vehicles. Advancement in industrial technology and political atmosphere in EU as the directive 20--20--20, which consists of reducing fossil emission, increasing renewable energy and increasing the energy efficiency, have made the electrification popular again. In this thesis tests based on standard ISO 16750--2 electrical loads for electrical equipment in road vehicles are made for Visedo Oy's PowerMASTER M-frame power electronics device. This device is designed for mainly drive trains in mobile work machines and marine vessels but can be used in other application in its power range which also includes road vehicles. The functionality of the device is tested with preliminary tests which act as a framework for the tests based on standards.
Resumo:
A photograph negative of Donald Ziraldo working a machine.
Resumo:
Letter containing a handwritten list of prices for items such as tripods and sockets sent to Mr. S.D. Woodruff from Troughton and Simms of Fleet Street, London, England, Feb.23, 1846.
Resumo:
Letter of estimate sent to S.D. Woodruff for the total cost of construction and equipment of the extension of the line to Port Colborne [this is unsigned]. There is an envelope with this letter that suggests that it is from Mr. Shanly, Mar. 12, 1857.
Resumo:
This thesis reports on the details of the works done to develop a complete system for acquisition of the important marine environmental parameters namely, current, current direction, salinity, temperature and depth. It encompaéps transducers,signalconditioners display arrangements and remote controlled multiplexer which constitue the system. The various associate instruentation and environmental requisites and problems have been discussed and solved to considerable extend. The design and development features of this composite system includes an integrated approach in order to make the final equipment to be simple, inexpensive and easy for operation from small and large boats. This could be achieved with the successful development of all required components with features matching between them, such as sensors, signals conditioners remote operated multiplexers, comon display methods, quick performance check and calibration methods. The major success rests on the development of sensors with excellent performance characteristics suitable for marine environment. out of the 5 sensors. that of current salinity and depth are quite noval types with specific advantages. The environmental effects have been eliminated to the required extend. The common signal conditioner for salinity, temperature and depth has noval design features for achieving simplicity, reliability and accomodating the three sensors of different functional requirements.
Resumo:
Chemical sensors have growing interest in the determination of food additives, which are creating toxicity and may cause serious health concern, drugs and metal ions. A chemical sensor can be defined as a device that transforms chemical information, ranging from the concentration of a specific sample component to total composition analysis, into an analytically useful signal. The chemical information may be generated from a chemical reaction of the analyte or from a physical property of the system investigated. Two main steps involved in the functioning of a chemical sensor are recognition and transduction. Chemical sensors employ specific transduction techniques to yield analyte information. The most widely used techniques employed in chemical sensors are optical absorption, luminescence, redox potential etc. According to the operating principle of the transducer, chemical sensors may be classified as electrochemical sensors, optical sensors, mass sensitive sensors, heat sensitive sensors etc. Electrochemical sensors are devices that transform the effect of the electrochemical interaction between analyte and electrode into a useful signal. They are very widespread as they use simple instrumentation, very good sensitivity with wide linear concentration ranges, rapid analysis time and simultaneous determination of several analytes. These include voltammetric, potentiometric and amperometric sensors. Fluorescence sensing of chemical and biochemical analytes is an active area of research. Any phenomenon that results in a change of fluorescence intensity, anisotropy or lifetime can be used for sensing. The fluorophores are mixed with the analyte solution and excited at its corresponding wavelength. The change in fluorescence intensity (enhancement or quenching) is directly related to the concentration of the analyte. Fluorescence quenching refers to any process that decreases the fluorescence intensity of a sample. A variety of molecular rearrangements, energy transfer, ground-state complex formation and collisional quenching. Generally, fluorescence quenching can occur by two different mechanisms, dynamic quenching and static quenching. The thesis presents the development of voltammetric and fluorescent sensors for the analysis of pharmaceuticals, food additives metal ions. The developed sensors were successfully applied for the determination of analytes in real samples. Chemical sensors have multidisciplinary applications. The development and application of voltammetric and optical sensors continue to be an exciting and expanding area of research in analytical chemistry. The synthesis of biocompatible fluorophores and their use in clinical analysis, and the development of disposable sensors for clinical analysis is still a challenging task. The ability to make sensitive and selective measurements and the requirement of less expensive equipment make electrochemical and fluorescence based sensors attractive.
Resumo:
Short set of slides explaining the workflow from a university website to equipment.data.ac.uk
Resumo:
La ciencia en la escuela primaria resulta cada vez más solicitada, por ello los maestros deben aprender a elegir entre una gama de equipos cada vez más sofisticados. El objetivo es ayudar a los docentes en su tarea de garantizar que los niños accedan a un equipamiento científico adecuado,y que las escuelas desarrollen una política progresista en el suministro, uso y cuidado de estos aparatos.