949 resultados para Cross-correlation function


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A novel strategy for fast NMR resonance assignment of N-15 HSQC spectra of proteins is presented. It requires the structure coordinates of the protein, a paramagnetic center, and one or more residue-selectively N-15-labeled samples. Comparison of sensitive undecoupled N-15 HSQC spectra recorded of paramagnetic and diamagnetic samples yields data for every cross-peak on pseudocontact shift, paramagnetic relaxation enhancement, cross-correlation between Curie-spin and dipole-dipole relaxation, and residual dipolar coupling. Comparison of these four different paramagnetic quantities with predictions from the three-dimensional structure simultaneously yields the resonance assignment and the anisotropy of the susceptibility tensor of the paramagnetic center. The method is demonstrated with the 30 kDa complex between the N-terminal domain of the epsilon subunit and the theta subunit of Escherichia Coll DNA polymerase III. The program PLATYPUS was developed to perform the assignment, provide a measure of reliability of the assignment, and determine the susceptibility tensor anisotropy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In high-velocity free-surface flows, air is continuously being trapped and released through the free-surface. Such high-velocity highly-aerated flows cannot be studied numerically because of the large number of relevant equations and parameters. Herein an advanced signal processing of traditional single- and dual-tip conductivity probes provides some new information on the air-water turbulent time and length scales. The technique is applied to turbulent open channel flows in a large-size facility. The auto- and cross-correlation analyses yield some characterisation of the large eddies advecting the bubbles. The transverse integral turbulent length and time scales are related to the step height: i.e., Lxy/h ~ 0.02 to 0.2, and T.sqrt(g/h) ~ 0.004 to 0.04. The results are irrespective of the Reynolds numbers. The present findings emphasise that turbulent dissipation by large-scale vortices is a significant process in the intermediate zone between the spray and bubbly flow regions (0.3 < C < 0.7). Some self-similar relationships were observed systematically at both macroscopic and microscopic levels. The results are significant because they provide a picture general enough to be used to characterise the air-water flow field in prototype spillways.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In order to determine the role played by heroin purity in fatal heroin overdoses, time series analyses were conducted on the purity of street heroin seizures in south western Sydney and overdose fatalities in that region. A total of 322 heroin samples were analysed in fortnightly periods between February 1993 to January 1995. A total of 61 overdose deaths occurred in the region in the study period. Cross correlation plots revealed a significant correlation of 0.57 at time lag zero between mean purity of heroin samples per fortnight and number of overdose fatalities. Similarly, there was a significant correlation of 0.50 at time lag zero between the highest heroin purity per fortnight and number of overdose fatalities. The correlation between range of heroin purity and number of deaths per fortnight was 0.40. A simultaneous multiple regression on scores adjusted for first order correlation indicated both the mean level of heroin purity and the range of heroin purity were independent predictors of the number of deaths per fortnight. The results indicate that the occurrence of overdose fatalities was moderately associated with both the average heroin purity and the range of heroin purity over the study period. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background The aim of this study was to validate a biomagnetic method (alternate current biosusceptometry, ACB) for monitoring gastric wall contractions in rats. Methods In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed in pentobarbital-anesthetized rats with SG and magnetic markers previously implanted under the gastric serosa or after ingestion of magnetic material. Gastric motility was quantified from the tracing amplitudes and frequency profiles obtained by Fast Fourier Transform. Key Results The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation coefficient between the ACB and SG signal amplitude was higher (P < 0.0001) in the postprandial (88.3 +/- 9.1 V) than in the fasting state (31.0 +/- 16.9 V). Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation between techniques for fasting-state recordings. When a magnetic material was ingested, there was also strong correlation in the frequency and signal amplitude and a small phase-difference between the techniques. The contraction frequencies using ACB were 0.068 +/- 0.007 Hz (postprandial) and 0.058 +/- 0.007 Hz (fasting) (P < 0.002) and those using SG were 0.066 +/- 0.006 Hz (postprandial) and 0.059 +/- 0.008 Hz (fasting) (P < 0.005). Conclusions & Inferences In summary, ACB is reliable for monitoring gastric wall contractions using both implanted and ingested magnetic materials, and may serve as an accurate and sensitive technique for gastrointestinal motility studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Área de especialização: Imagem Digital por Radiação X.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neste relatório apresentam-se resultados de um estudo estatístico que procura contribuir para um melhor entendimento da problemática inerente à liberalização do setor elétrico em Portugal e dos desafios que esta liberalização, existente desde meados de 2007, trás aos seus intervenientes. Iniciam-se os trabalhos com um estudo que pretende avaliar a existência de relação entre o Preço de Mercado da eletricidade e um conjunto de variáveis potencialmente explicativas/condicionantes do Preço de Mercado. Neste estudo consideram-se duas abordagens. A primeira usa a função de correlação cruzada para avaliar a existência de relação do tipo linear entre pares de variáveis. A segunda considera o teste causalidade de Granger na avaliação de uma relação de causa e efeito entre esses pares. Este estudo avaliou a relação entre o Preço de Mercado da eletricidade e 19 variáveis ditas condicionantes distribuídas por três categorias distintas (consumo e produção de eletricidade; indicadores climáticos; e energias primárias). O intervalo de tempo em estudo cinge-se ao biénio 2012-2103. Durante este período avaliam-se as relações entre as variáveis em diversos sub-períodos de tempo em ciclos de consumo representativos do consumo em baixa (fim de semana) e de consumo mais elevado (fora de vazio) com os valores observados de cada uma das variáveis tratados com uma base horária e diária (média). Os resultados obtidos mostram a existência relação linear entre algumas das variáveis em estudo e o preço da eletricidade em regime de mercado liberalizado, mas raramente é possível identificar precedência temporal entre as variáveis. Considerando os resultados da análise de correlação e causalidade, apresenta-se ainda um modelo de previsão do Preço de Mercado para o curto e médio prazo em horas de período fora de vazio.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In a transversal study on a sample of 386 children and adolescents from an outpatient clinic for filariasis in Recife, Northeast Brazil, the frequency of anti-Toxocara antibodies and its relation to age, gender, number of peripheral eosinophils, Wuchereria bancrofti microfilariae and intestinal helminths was determined. The total anti-Toxocara IgG antibody frequency was 39.4%, by ELISA technique. The difference in frequency between males (40.1%) and females (37.6%) was not statistically significant. The 6 to 10-year-old subset presented the highest frequency of anti-Toxocara antibodies (60%), and within this age group there was a statistically significant male bias. There was also a significant association between the number of eosinophils and the presence of anti-Toxocara antibodies. Intestinal parasite frequency was 52.1%, but no association was found between this data and the presence of anti-Toxocara antibodies. In the present sample, 42.2% of the patients were Wuchereria bancrofti carriers, however, again this was not associated with the presence of anti-Toxocara antibodies. In conclusion, anti-Toxocara antibodies were highly prevalent in this sample. The present data show that there is no cross correlation between anti-Toxocara IgG antibody and the presence of intestinal helminths and filariasis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

High transverse momentum jets produced in pp collisions at a centre of mass energy of 7 TeV are used to measure the transverse energy--energy correlation function and its associated azimuthal asymmetry. The data were recorded with the ATLAS detector at the LHC in the year 2011 and correspond to an integrated luminosity of 158 pb−1. The selection criteria demand the average transverse momentum of the two leading jets in an event to be larger than 250 GeV. The data at detector level are well described by Monte Carlo event generators. They are unfolded to the particle level and compared with theoretical calculations at next-to-leading-order accuracy. The agreement between data and theory is good and provides a precision test of perturbative Quantum Chromodynamics at large momentum transfers. From this comparison, the strong coupling constant given at the Z boson mass is determined to be αs(mZ)=0.1173±0.0010 (exp.) +0.0065−0.0026 (theo.).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This project was funded under the Applied Research Grants Scheme administered by Enterprise Ireland. The project was a partnership between Galway - Mayo Institute of Technology and an industrial company, Tyco/Mallinckrodt Galway. The project aimed to develop a semi - automatic, self - learning pattern recognition system capable of detecting defects on the printed circuits boards such as component vacancy, component misalignment, component orientation, component error, and component weld. The research was conducted in three directions: image acquisition, image filtering/recognition and software development. Image acquisition studied the process of forming and digitizing images and some fundamental aspects regarding the human visual perception. The importance of choosing the right camera and illumination system for a certain type of problem has been highlighted. Probably the most important step towards image recognition is image filtering, The filters are used to correct and enhance images in order to prepare them for recognition. Convolution, histogram equalisation, filters based on Boolean mathematics, noise reduction, edge detection, geometrical filters, cross-correlation filters and image compression are some examples of the filters that have been studied and successfully implemented in the software application. The software application developed during the research is customized in order to meet the requirements of the industrial partner. The application is able to analyze pictures, perform the filtering, build libraries, process images and generate log files. It incorporates most of the filters studied and together with the illumination system and the camera it provides a fully integrated framework able to analyze defects on printed circuit boards.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abnormalities in the topology of brain networks may be an important feature and etiological factor for psychogenic non-epileptic seizures (PNES). To explore this possibility, we applied a graph theoretical approach to functional networks based on resting state EEGs from 13 PNES patients and 13 age- and gender-matched controls. The networks were extracted from Laplacian-transformed time-series by a cross-correlation method. PNES patients showed close to normal local and global connectivity and small-world structure, estimated with clustering coefficient, modularity, global efficiency, and small-worldness (SW) metrics, respectively. Yet the number of PNES attacks per month correlated with a weakness of local connectedness and a skewed balance between local and global connectedness quantified with SW, all in EEG alpha band. In beta band, patients demonstrated above-normal resiliency, measured with assortativity coefficient, which also correlated with the frequency of PNES attacks. This interictal EEG phenotype may help improve differentiation between PNES and epilepsy. The results also suggest that local connectivity could be a target for therapeutic interventions in PNES. Selective modulation (strengthening) of local connectivity might improve the skewed balance between local and global connectivity and so prevent PNES events.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Functional connectivity in human brain can be represented as a network using electroencephalography (EEG) signals. These networks--whose nodes can vary from tens to hundreds--are characterized by neurobiologically meaningful graph theory metrics. This study investigates the degree to which various graph metrics depend upon the network size. To this end, EEGs from 32 normal subjects were recorded and functional networks of three different sizes were extracted. A state-space based method was used to calculate cross-correlation matrices between different brain regions. These correlation matrices were used to construct binary adjacency connectomes, which were assessed with regards to a number of graph metrics such as clustering coefficient, modularity, efficiency, economic efficiency, and assortativity. We showed that the estimates of these metrics significantly differ depending on the network size. Larger networks had higher efficiency, higher assortativity and lower modularity compared to those with smaller size and the same density. These findings indicate that the network size should be considered in any comparison of networks across studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Intracardiac organization indices such as atrial fibril- lation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of long-standing persistent AF (pers-AF), however, with lim- ited success. The timing between nearby bipolar intracar- diac electrograms (EGMs) reflects the spatial dynamics of wavelets during AF. The extent of synchronization between EGMs is an indirect measure of AF spatial organization. The synchronization between nearby EGMs during step- CA of pers-AF was evaluated using new indices based on the cross-correlation. The first one (spar(W)) quantifies the sparseness of the cross-correlation of local activation times. The second one (OI(W)) reflects the local concen- tration around the largest peak of the cross-correlation. By computing their relative evolution during step-CA until AF termination (AF-term), we found that OI(W) appeared su- perior to AFCL and spar(W) to track the effect of step-CA "en route" to AF-term.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The consolidation of a universal health system coupled with a process of regionaldevolution characterise the institutional reforms of the National Health System(NHS) in Spain in the last two decades. However, scarce empirical evidence hasbeen reported on the effects of both changes in health inputs, outputs andoutcomes, both at the country and at the regional level. This paper examinesthe empirical evidence on regional diversity, efficiency and inequality ofthese changes in the Spanish NHS using cross-correlation, panel data andexpenditure decomposition analysis. Results suggest that besides significantheterogeneity, once we take into account region-specific needs there is evidenceof efficiency improvements whilst inequalities in inputs and outcomes, althoughmore visible , do not appear to have increased in the last decade. Therefore,the devolution process in the Spanish Health System offers an interesting casefor the experimentation of health reforms related to regional diversity butcompatible with the nature of a public NHS, with no sizeable regionalinequalitiest.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Las características principales de las redes de cerco artesanales anchoveteras para CHD (PS 01.1.0 “ISSCFG”), utilizan tamaños de malla en el copo y cuerpo de ½” ~ 13 mm de material nylon Poliamida (PA). Se encontró una diferencia en las dimensiones, el material y diámetro del hilo del paño usado, entre las redes de las ANC-CHD tradicionales (Paita, Chimbote, Callao e Ilo) que utilizan paños anchoveteros de R310tex, R381tex R462tex, con longitud de relinga superior (LRS) de 183-366 m (100 a 200 bz), altura de paño estirado (AHE) de 27 a 64 m (15 a 35 bz); y las redes de cerco ANC-Pisco que utilizan paños anchoveteros de R155tex y R230tex, con LRS de 270 a 396 m (145 a 215 bz) y AHE de 30 m (16 bz). Del análisis regresional experimental, las principales características de la red (LRS, AHE), y la embarcación–capacidad de bodega-(CBOD) presentaron correlaciones significativas para la flota ANC-Tradicional (r = 0,86 y 0,91), mientras que en la flota ANC-Pisco las correlación de la función CBODLRS fue de 0,30 y la AHE fue constante (30 m) para todo el rango de LRS (270 - 396 m).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Diffuse flow velocimetry (DFV) is introduced as a new, noninvasive, optical technique for measuring the velocity of diffuse hydrothermal flow. The technique uses images of a motionless, random medium (e.g.,rocks) obtained through the lens of a moving refraction index anomaly (e.g., a hot upwelling). The method works in two stages. First, the changes in apparent background deformation are calculated using particle image velocimetry (PIV). The deformation vectors are determined by a cross correlation of pixel intensities across consecutive images. Second, the 2-D velocity field is calculated by cross correlating the deformation vectors between consecutive PIV calculations. The accuracy of the method is tested with laboratory and numerical experiments of a laminar, axisymmetric plume in fluids with both constant and temperaturedependent viscosity. Results show that average RMS errors are ∼5%–7% and are most accurate in regions of pervasive apparent background deformation which is commonly encountered in regions of diffuse hydrothermal flow. The method is applied to a 25 s video sequence of diffuse flow from a small fracture captured during the Bathyluck’09 cruise to the Lucky Strike hydrothermal field (September 2009). The velocities of the ∼10°C–15°C effluent reach ∼5.5 cm/s, in strong agreement with previous measurements of diffuse flow. DFV is found to be most accurate for approximately 2‐D flows where background objects have a small spatial scale, such as sand or gravel