Tracking of Stepwise Ablation of Persistent Atrial Fibrillation using Synchronization of nearby Electrogams


Autoria(s): Buttu A.; Volorio S.; Forclaz A.; Pascale P.; Narayan S.M.; Pruvot E.; Vesin J.M.
Data(s)

2011

Resumo

Intracardiac organization indices such as atrial fibril- lation (AF) cycle length (AFCL) have been used to track the efficiency of stepwise catheter ablation (step-CA) of long-standing persistent AF (pers-AF), however, with lim- ited success. The timing between nearby bipolar intracar- diac electrograms (EGMs) reflects the spatial dynamics of wavelets during AF. The extent of synchronization between EGMs is an indirect measure of AF spatial organization. The synchronization between nearby EGMs during step- CA of pers-AF was evaluated using new indices based on the cross-correlation. The first one (spar(W)) quantifies the sparseness of the cross-correlation of local activation times. The second one (OI(W)) reflects the local concen- tration around the largest peak of the cross-correlation. By computing their relative evolution during step-CA until AF termination (AF-term), we found that OI(W) appeared su- perior to AFCL and spar(W) to track the effect of step-CA "en route" to AF-term.

Identificador

http://serval.unil.ch/?id=serval:BIB_0C0EF3B11465

isbn:0276−6574

http://my.unil.ch/serval/document/BIB_0C0EF3B11465.pdf

http://nbn-resolving.org/urn/resolver.pl?urn=urn:nbn:ch:serval-BIB_0C0EF3B114651

Idioma(s)

en

Direitos

info:eu-repo/semantics/openAccess

Fonte

38th Annual Scientific Conference of Computing in Cardiology

Tipo

info:eu-repo/semantics/conferenceObject

inproceedings