989 resultados para Consumidor 3.0
Resumo:
This work aims to reflect on the role of professional public relations in the context of connected information society and, therefore, understand how the internet has changed life in society, evaluating their impact on organizations, communication and public relations. Certainly the communication as a whole is no longer the same after the arrival of the online universe. Organizations, in turn, also are not out of context and begin to feel the impacts of such changes. Perform a reflection on the current situation and the practices and functions of public relations is fundamental to that in the midst of many technological innovations, do not ignore the essence of humanistic profession
Resumo:
This paper aims to discuss the influence of the Public Relations professional in the current market environment, where the client's relationship with the organization is visibly marked by greater freedom of the latter in the decision of buying. The importance of the work and vision of this professional can be observed trough the paths marketing area had been taking, like the appearance of Marketing 3.0. In this paper the intention is to study the paths who lead to the convergence of both areas and in what way both professionals can allied their knowledge aiming to succeed in the market, without ignoring the fact that the results will be better and better the more genuine is the philosophy of respect for the client practiced by the organization and its employees
Resumo:
With Hg-199 atoms confined in an optical lattice trap in the Lamb-Dicke regime, we obtain a spectral line at 265.6 nm for which the FWHM is similar to 15 Hz. Here we lock an ultrastable laser to this ultranarrow S-1(0) - P-3(0) clock transition and achieve a fractional frequency instability of 5.4 x 10(-15) / root tau for tau <= 400 s. The highly stable laser light used for the atom probing is derived from a 1062.6 nm fiber laser locked to an ultrastable optical cavity that exhibits a mean drift rate of -6.0 x 10(-17) s-(1) (-16.9 mHzs(-1) at 282 THz) over a six month period. A comparison between two such lasers locked to independent optical cavities shows a flicker noise limited fractional frequency instability of 4 x 10(-16) per cavity. (c) 2012 Optical Society of America
Resumo:
Con l’evoluzione dei social network e degli strumenti del 2.0 (blog, wiki, forum), internet si avvia verso nuove forme di business cui artigiani e pmi possono sfruttare per nuove opportunità, unendo social network e e-commerce e capire come si è evoluto il processo di creazione e finanziamento di un prodotto. La tesi è un viaggio per scoprire quali sono queste nuove opportunità per chi pratica artigianato a livello locale, e come è cambiata la figura stessa dell’artigiano, tra questi un nuovo movimento chiamato makers, che sfruttano i nuovi strumenti, tra cui anche mezzi rivoluzionari come la stampante 3D ora accessibile a tutti per creare oggetti e nuove idee. Sarà necessario capire quali sono le vetrine online dove e come poter vendere i nostri prodotti e profilare attraverso una segmentazione l’utente medio che già utilizza il social-commerce. In seguito si tratta il caso empirico di una start-up italiana, Blomming, una dei primi a differenziarsi dagli altri marketplace più famosi come contenitore adatto ad artigiani, ma non solo. Si seguiranno le varie fasi di crescita da un’idea, introduzione nel mercato fino alla direzione a cui si sta avviando con le ultime novità effettuando un’analisi dei rischi. Infine per capire tendenze e storie di chi sta già usando queste piattaforme è stato necessario fare un profilo dell’artigiano fai-da-te medio intervistando, e successivamente creando grafici, 100 artigiani che già vendono online.
Resumo:
To assess the relationship of morphologically defined lumbar disc abnormalities with quantitative T2 mapping.
Resumo:
To use T2 and T2* mapping in patients after matrix-associated autologous chondrocyte transplantation (MACT) of the knee, and to compare and correlate both methodologies.
Resumo:
The purpose was to investigate the in vivo effects of unloading and compression on T1-Gd relaxation times in healthy articular knee cartilage.
Resumo:
The aim of the study was to investigate the association of T2 relaxation times of the knee with early degenerative cartilage changes. Furthermore the impact of unloading the knee on T2 values was evaluated.
Resumo:
Preoperative mapping of the arterial spinal supply prior to thoracoabdominal aortic aneurysm repair is highly relevant because of high risk for postoperative ischemic spinal cord injuries such as paraparesis or paraplegia.
Resumo:
The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using the metabolite cycling technique for non-water-suppressed MR spectroscopy from a large brain voxel in 11 healthy volunteers at 3.0 T. The exchange rates of the most prominent peaks downfield of water were found to range from 0.5 to 8.9 s(-1), while the T(1) relaxation times in absence of exchange were found to range from 175 to 525 ms. These findings may help toward the assignments of the downfield resonances and a better understanding of the sources of contrast in chemical exchange saturation transfer imaging.
Resumo:
To assess, compare and correlate quantitative T2 and T2* relaxation time measurements of intervertebral discs (IVDs) in patients suffering from low back pain, with respect to the IVD degeneration as assessed by the morphological Pfirrmann Score. Special focus was on the spatial variation of T2 and T2* between the annulus fibrosus (AF) and the nucleus pulposus (NP).
Resumo:
To define the feasibility of utilizing T2* mapping for assessment of early cartilage degeneration prior to surgery in patients with symptomatic femoroacetabular impingement (FAI), we compared cartilage of the hip joint in patients with FAI and healthy volunteers using T2* mapping at 3.0 Tesla over time.
Resumo:
A variety of modified nucleosides to improve antisense oligodeoxynucleotide properties such as target affinity, nuclease resistance, and pharmacokinetics were developed in the last two decades. In the context of conformational restriction we present here the synthesis of the [4.3.0]-bicyclo-DNA thymine monomer via Pd(II)-mediated ring expansion of an intermediate of the tricyclo-DNA synthesis.
Resumo:
OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.
Resumo:
OBJECTIVES: To assess magnetic resonance (MR)-colonography (MRC) for detection of colorectal lesions using two different T1w three-dimensional (3D)-gradient-recalled echo (GRE)-sequences and integrated parallel data acquisition (iPAT) at a 3.0 Tesla MR-unit. MATERIALS AND METHODS: In this prospective study, 34 symptomatic patients underwent dark lumen MRC at a 3.0 Tesla unit before conventional colonoscopy (CC). After colon distension with tap water, 2 high-resolution T1w 3D-GRE [3-dimensional fast low angle shot (3D-FLASH), iPAT factor 2 and 3D-volumetric interpolated breathhold examination (VIBE), iPAT 3] sequences were acquired without and after bolus injection of gadolinium. Prospective evaluation of MRC was performed. Image quality of the different sequences was assessed qualitatively and quantitatively. The findings of the same day CC served as standard of reference. RESULTS: MRC identified all polyps >5 mm (16 of 16) in size and all carcinomas (4 of 4) correctly. Fifty percent of the small polyps =5 mm (4 of 8) were visualized by MRC. Diagnostic quality was excellent in 94% (384 of 408 colonic segments) using the 3D-FLASH and in 92% (376 of 408) for the VIBE. The 3D-FLASH sequence showed a 3-fold increase in signal-to-noise ratio (8 +/- 3.3 standard deviation (SD) in lesions without contrast enhancement (CE); 24.3 +/- 7.8 SD after CE). For the 3D-VIBE sequence, signal-to-noise ratio doubled in the detected lesions (147 +/- 54 SD without and 292 +/- 168 SD after CE). Although image quality was ranked lower in the VIBE, the image quality score of both sequences showed no statistical significant difference (chi > 0.6). CONCLUSIONS: MRC using 3D-GRE-sequences and iPAT is feasible at 3.0 T-systems. The high-resolution 3D-FLASH was slightly preferred over the 3D-VIBE because of better image quality, although both used sequences showed no statistical significant difference.