693 resultados para Calibração de camêra


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Image acquisition systems based on multi-head arrangement of digital frame cameras, such as the commercial systems DMC, UltraCam, besides others, are attractive alternatives enabling larger imaging area when compared to a single frame camera. Considering that in these systems, cameras are tightly attached to an external mount, it is assumed that relative position and orientation between cameras are stable during image acquisition and, consequently, these constraint can be included in the calibration step. This constraint is acceptable because estimates of the relative orientation (RO) parameters between cameras, from previously estimated exterior orientation parameters, present higher and significant deviations than the expected physical variations, due to error propagation. In order to solve this problem, this work presents an approach based on simultaneous calibration of two or more cameras using constraints that state that the relative rotation matrix and the distance between the cameras head are stable. Experiments with images acquired by an arrangement of two Hasselblad H2D cameras were accomplished, without and with the mentioned constraints. The experiments showed that the calibration process with RO constraints allows better results than the approach based on single camera calibration, provided that the estimation has included only images with good target distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo visou à obtenção das curvas de calibração de um equipamento de TDR (Time Domain Reflectometry) em cinco solos da região de Piracicaba, SP, e testou a adequação da calibração interna do equipamento e das curvas genéricas de calibração. As curvas ajustadas, em cada solo separadamente, apresentaram coeficientes de determinação (R²) da ordem de 0,99, e a curva ajustada para o conjunto de dados dos cinco solos apresentou R² = 0,976. A análise de erros-padrão de estimativa mostrou que as curvas genéricas não se prestam às aplicações mais sensíveis, tais como na determinação absoluta do conteúdo de água do solo. Os testes de comparação entre as curvas ajustadas, a curva genérica e a curva embutida no equipamento mostraram que a primeira é superior às demais. O estudo mostrou, também, que a curva de calibração embutida no equipamento é inadequada para as determinações de umidade nos cinco solos estudados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is combined with the potential of the technique of near infrared spectroscopy - NIR and chemometrics order to determine the content of diclofenac tablets, without destruction of the sample, to which was used as the reference method, ultraviolet spectroscopy, which is one of the official methods. In the construction of multivariate calibration models has been studied several types of pre-processing of NIR spectral data, such as scatter correction, first derivative. The regression method used in the construction of calibration models is the PLS (partial least squares) using NIR spectroscopic data of a set of 90 tablets were divided into two sets (calibration and prediction). 54 were used in the calibration samples and the prediction was used 36, since the calibration method used was crossvalidation method (full cross-validation) that eliminates the need for a validation set. The evaluation of the models was done by observing the values of correlation coefficient R 2 and RMSEC mean square error (calibration error) and RMSEP (forecast error). As the forecast values estimated for the remaining 36 samples, which the results were consistent with the values obtained by UV spectroscopy

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the quantitative analysis of glucose, triglycerides and cholesterol (total and HDL) in both rat and human blood plasma was performed without any kind of pretreatment of samples, by using near infrared spectroscopy (NIR) combined with multivariate methods. For this purpose, different techniques and algorithms used to pre-process data, to select variables and to build multivariate regression models were compared between each other, such as partial least squares regression (PLS), non linear regression by artificial neural networks, interval partial least squares regression (iPLS), genetic algorithm (GA), successive projections algorithm (SPA), amongst others. Related to the determinations of rat blood plasma samples, the variables selection algorithms showed satisfactory results both for the correlation coefficients (R²) and for the values of root mean square error of prediction (RMSEP) for the three analytes, especially for triglycerides and cholesterol-HDL. The RMSEP values for glucose, triglycerides and cholesterol-HDL obtained through the best PLS model were 6.08, 16.07 e 2.03 mg dL-1, respectively. In the other case, for the determinations in human blood plasma, the predictions obtained by the PLS models provided unsatisfactory results with non linear tendency and presence of bias. Then, the ANN regression was applied as an alternative to PLS, considering its ability of modeling data from non linear systems. The root mean square error of monitoring (RMSEM) for glucose, triglycerides and total cholesterol, for the best ANN models, were 13.20, 10.31 e 12.35 mg dL-1, respectively. Statistical tests (F and t) suggest that NIR spectroscopy combined with multivariate regression methods (PLS and ANN) are capable to quantify the analytes (glucose, triglycerides and cholesterol) even when they are present in highly complex biological fluids, such as blood plasma

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, the basic concepts of radiometric, photometric and colorimetric calibration are presented, which were applied to three light-emitting diodes (LEDs) used to compose the different color sensations that the human eye perceives in the visible region of the electromagnetic spectrum. In this sense, an experimental setup comprising a LED drive circuit and a home-made integrating sphere was assembled for the initial radiometric and photometric calibration as well as to obtain a set of intensity and spectral combinations associated to different colorimetric CIE (Commission Internationale de l'Eclairage) coordinates. The reader can, therefore, understand, in a simple manner, the process of color composition inside a color monitor or display picture element (pixel ). © Sociedade Brasileira de Física.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Proteção de Plantas) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Energia na Agricultura) - FCA

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação trata sobre o Sistema de Gestão implantado no Centro de Tecnologia da Eletrobras - Eletronorte – OCT, face à norma ABNT NBR ISO/IEC17025. Objetiva analisar o Sistema de Gestão da Qualidade em laboratório de ensaio. Expõe o crescimento do uso de sistemas de gestão, para dizer que em geral tem aumentado à necessidade de assegurar que laboratórios que fazem parte de organizações maiores ou que oferecem outros serviços possam operar de acordo com um sistema de gestão que esteja em conformidade com a norma ABNT NBR ISO 9001. Para conduzir e operar com sucesso uma organização é necessário dirigila e controlá-la de maneira transparente e sistemática. Verifica-se que seu sucesso pode resultar da implementação e manutenção de um sistema de gestão concebido para melhorar continuamente seu desempenho, levando em consideração, ao mesmo tempo, as necessidades de todas as partes interessadas. Os laboratórios acreditados garantem aspectos referentes à confiabilidade, a confidencialidade dos resultados propostos, além da rastreabilidade dos padrões utilizados nos ensaios e calibrações.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A ocorrência de escorregamentos translacionais no litoral paulista é parte integrante da evolução natural das encostas, que se intensifica sob condições de clima tropical em uma morfologia de serras com desníveis em torno de 700m. Sob precipitações intensas, mesmo sem a interferência direta do homem, os movimentos de massa ocorrem de forma isolada ou generalizada, como a centena de escorregamentos registrados no evento de janeiro de 1985, em que os índices pluviométricos atingiram 210 mm em 24 h. Utilizando um inventário de cicatrizes de escorregamentos obtido de um aerolevantamento de agosto de 1985, definiu-se como objetivo calibrar e validar um mapa de índice de estabilidade utilizando o modelo de análise de estabilidade de encostas por talude infinito, disponível no programa SINMAP, na Serra de Cubatão, na escala 1:10.000. O modelo foi aplicado considerando os parâmetros do solo constantes para toda área e também variáveis em função das unidades litológicas. Os resultados mostraram que mais de 79% das cicatrizes ficaram dentro dos limites inferior de estabilidade e superior de instabilidade para o caso de parâmetros constantes e mais de 95% das cicatrizes para o caso de parâmetros variáveis dentro dos mesmos limites. Palavras-chave: Índice de estabilidade, movimentos de massa, Serra do Mar.