942 resultados para CONTINUOUS-WAVE


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A diode stack end-pumped Nd:YVO4 slab laser at 1342 nm with near-diffraction-limited beam quality by using a hybrid resonator was presented. At a pump power of 139.5 W, laser power of 35.4 W was obtained with a conversion efficiency of 25.4% of the laser diode to laser output. The beam quality M-2 factors were measured to be 1.2 in the unstable direction and 1.3 in the stable direction at the output power of 29 W. (C) 2009 Optical Society of America

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We analyse the physical origin of population inversion via continuous wave two-colour coherent excitation in three-level systems by dressing the inverted transition. Two different mechanisms are identified as being responsible for the population inversion. For V-configured systems and cascade (E) configured systems with inversion on the lower transition, the responsible mechanism is the selective trapping of dressed states, and the population inversion approaches the ideal value of 1. For Lambda-configured systems and Xi-configured systems with inversion on the upper transition, population inversion is based on the selective excitation of dressed states, with the population inversion tending towards 0.5. As the essential difference between these two mechanisms, the selective trapping of dressed states occurs in systems with strong decay into dressed states while the selective excitation appears in systems with strong decay out of dressed states.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The transient evolution processes and steady outputs of continuous wave lasing without inversion (LWI) and self-pulsing LWI in a resonant open V type three-level system are studied. It was found that the two kinds of LWI have some obvious differences not only from the steady outputs but also from the transient evolution processes. The effects of the unsaturated gain coefficient, cavity loss coefficient, ratio of the atomic injection rates and atomic exit rate on the transient evolution processes and steady outputs are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis explores the design, construction, and applications of the optoelectronic swept-frequency laser (SFL). The optoelectronic SFL is a feedback loop designed around a swept-frequency (chirped) semiconductor laser (SCL) to control its instantaneous optical frequency, such that the chirp characteristics are determined solely by a reference electronic oscillator. The resultant system generates precisely controlled optical frequency sweeps. In particular, we focus on linear chirps because of their numerous applications. We demonstrate optoelectronic SFLs based on vertical-cavity surface-emitting lasers (VCSELs) and distributed-feedback lasers (DFBs) at wavelengths of 1550 nm and 1060 nm. We develop an iterative bias current predistortion procedure that enables SFL operation at very high chirp rates, up to 10^16 Hz/sec. We describe commercialization efforts and implementation of the predistortion algorithm in a stand-alone embedded environment, undertaken as part of our collaboration with Telaris, Inc. We demonstrate frequency-modulated continuous-wave (FMCW) ranging and three-dimensional (3-D) imaging using a 1550 nm optoelectronic SFL.

We develop the technique of multiple source FMCW (MS-FMCW) reflectometry, in which the frequency sweeps of multiple SFLs are "stitched" together in order to increase the optical bandwidth, and hence improve the axial resolution, of an FMCW ranging measurement. We demonstrate computer-aided stitching of DFB and VCSEL sweeps at 1550 nm. We also develop and demonstrate hardware stitching, which enables MS-FMCW ranging without additional signal processing. The culmination of this work is the hardware stitching of four VCSELs at 1550 nm for a total optical bandwidth of 2 THz, and a free-space axial resolution of 75 microns.

We describe our work on the tomographic imaging camera (TomICam), a 3-D imaging system based on FMCW ranging that features non-mechanical acquisition of transverse pixels. Our approach uses a combination of electronically tuned optical sources and low-cost full-field detector arrays, completely eliminating the need for moving parts traditionally employed in 3-D imaging. We describe the basic TomICam principle, and demonstrate single-pixel TomICam ranging in a proof-of-concept experiment. We also discuss the application of compressive sensing (CS) to the TomICam platform, and perform a series of numerical simulations. These simulations show that tenfold compression is feasible in CS TomICam, which effectively improves the volume acquisition speed by a factor ten.

We develop chirped-wave phase-locking techniques, and apply them to coherent beam combining (CBC) of chirped-seed amplifiers (CSAs) in a master oscillator power amplifier configuration. The precise chirp linearity of the optoelectronic SFL enables non-mechanical compensation of optical delays using acousto-optic frequency shifters, and its high chirp rate simultaneously increases the stimulated Brillouin scattering (SBS) threshold of the active fiber. We characterize a 1550 nm chirped-seed amplifier coherent-combining system. We use a chirp rate of 5*10^14 Hz/sec to increase the amplifier SBS threshold threefold, when compared to a single-frequency seed. We demonstrate efficient phase-locking and electronic beam steering of two 3 W erbium-doped fiber amplifier channels, achieving temporal phase noise levels corresponding to interferometric fringe visibilities exceeding 98%.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

本文报导了采用半导体激光器泵浦的高效连续可调谐Yb:LYSO激光器的输出特性。LYSO晶体同时具有LSO晶体良好的激光性能和YSO晶体易于生长且成本低廉的优点,实验中我们采用5at%掺杂的Yb:LYSO晶体进行研究,获得了最大输出功率2.84W、输出波长1085nm、光-光转换效率54.5%的高效输出。并且得到了1030-1111nm,一共81nm的波长调谐范围,这是目前我们所知道的从Yb:LYSO激光器获得的最宽的调谐输出。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We investigate the laser actions of 5at.% Yb:Gd2xY2(1-x)SiO5 (Yb:GYSO; x = 0.1) crystals with different cutting directions, parallel and vertical to the growth axis. Our results show that the cutting direction of the sample plays an astonished role in the laser operation. The sample cut vertically to the growth axis possesses the favourable lasing characteristics. Its output power reaches 3.13W at 1060nm with a slope efficiency of 44.68% when the absorbed pump power is 8.9 W. In contrast, the sample cut parallel reaches only 1.65 W at 1044 nm with a slope elLiciency of 33.76% with absorbed pump power of 7.99 W. The absorption and emission spectra of the two samples are examined and the merit factor M is calculated. Our analysis is in agreement well with the experimental results. The wavelength tuning range of the superior sample covers from 1013.68 nm to 1084.82 nm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Effective diode-pumped cw tunable laser action of a new alloyed crystal Yb:Gd(2(1-)x) Y2xSiO5 (Yb:GYSO, x = 0.5) is demonstrated for the first time. The alloyed crystal retains excellent laser properties of Gd2SiO5 (GSO), as well as the favorable growth properties and the desirable physical of Y2SiO5 (YSO). With a 5-at.% Yb: GYSO sample, we achieved 2.44 W output power at 1081.5 nm and a slope efficiency of 57%. And its laser wavelength could be tuned from 1030nm to 1089 nm. (c) 2006 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fluorescence spectra of Nd: YVO4 under excitation of a continuous wave (CW) diode laser and a femtosecond laser at 800nm were investigated. It was found that Nd: YVO4 shows different upconversion and downconversion luminescencent behaviors when excited by the diode laser and the femtosecond laser. The dependence of the upconversion luminescence intensity on the pump power of the femtosecond laser was discussed. The populations of the upper energy levels for upconversion and downconversion luminescence were calculated based on the Bloch equations. The calculations agree well with the experimental results. (c) 2007 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We present the theoretical analysis and the numerical modeling of optical levitation and trapping of the stuck particles with a pulsed optical tweezers. In our model, a pulsed laser was used to generate a large gradient force within a short duration that overcame the adhesive interaction between the stuck particles and the surface; and then a low power continuous - wave (cw) laser was used to capture the levitated particle. We describe the gradient force generated by the pulsed optical tweezers and model the binding interaction between the stuck beads and glass surface by the dominative van der Waals force with a randomly distributed binding strength. We numerically calculate the single pulse levitation efficiency for polystyrene beads as the function of the pulse energy, the axial displacement from the surface to the pulsed laser focus and the pulse duration. The result of our numerical modeling is qualitatively consistent with the experimental result. (C) 2005 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

对体布拉格光栅(VBG)作为波长选择元件的外腔半导体激光器的波长锁定进行了实验研究,报道了连续运转输出功率达43.5 W的半导体激光器阵列的体布拉格光栅波长锁定实验结果,给出了不同热沉温度下的稳定的波长锁定结果,说明采用体布拉格光栅外腔将减小半导体激光器的温控压力。实验中发现,随着注入电流的增大,输出激光功率逐渐增强,锁定的激射波长向长波长方向偏移。在输出功率为34.5 W时,波长红移约0.56 nm。这一移动与实验测量的体布拉格光栅的温度特性相吻合。连续和高占空比运行、高输出功率情况下,在器件的设计和使用时应该考虑这一效应。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experimental results of the Talbot effect of an amplitude grating under femtosecond laser illumination are reported. Compared with Talbot image under continuous wave (CW) illumination, Talbot images under femtosecond laser illumination are different due to the wide spectral bandwidth and the Talbot images are more distorted at longer Talbot distances. The spectrums and the pulsewidths of femtosecond laser pulses are measured with the frequency-resolved optical gating (FROG) apparatus. Experimental results are in good agreement with the theoretical analysis. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The concept of femtosecond laser speckles is put forward. The theory of a speckle pattern in light of finite bandwidth is applied to describe femtosecond laser speckles. Basic representations of the contrast and the spectral correlation of femtosecond laser speckles are presented. The relationship between the speckle contrast and the bandwidth of a femtosecond laser is given. Experimental results are given that indicate an obvious difference between the speckle patterns produced by a continuous-wave laser and those produced by a femtosecond laser. (c) 2005 Optical Society of America

Relevância:

60.00% 60.00%

Publicador:

Resumo:

用Ansys软件模拟了大功率半导体激光器阵列的稳态温度分布,并对自行研制的半导体激光器阵列的温度变化进行了测试,结果表明理论计算与实验结果基本吻合。该模拟结果对大功率半导体激光器阵列的封装设计具有现实的指导意义。

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Experimental investigation of Talbot self-imaging effect of an amplitude grating under illumination of femtosecond laser pulse -- the FemtoTalbot effect is reported. Theoretical analyzed results show that Talbot images under illumination of femtosecond laser pulses are not the same as that under continuous wave illumination. Experimental results are in good agreement with the theoretical analysis. We believe that the experimental investigation of the FemtoTalbot effect is highly interesting for the enormous potential applications of Talbot effect.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho teve por objetivo quantificar, comparativamente, a área de preenchimento de dois materiais obturadores sólidos, cones de guta-percha (GP) e cones de Resilon (R), no terço apical de incisivos inferiores humanos, ex vivo, obturados pela técnica da onda contínua de condensação. Os espécimes foram submetidos a um protocolo, desde a cirurgia de acesso até o final do preparo químico-mecânico e divididos aleatoriamente em dois grupos, de 21 dentes cada, de acordo com o material utilizado. Não foi utilizado cimento endodôntico em nenhuma das amostras. Após a obturação, as amostras foram seccionadas transversalmente em dois níveis, a 3 e a 5mm do ápice, e subdivididas em grupos de acordo com a altura de corte e do material obturador, sendo estabelecido: GP3 (guta-percha com corte a 3mm), GP5 (guta-percha com corte a 5mm), R3 (Resilon com corte a 3mm) e R5 (Resilon com corte a 5mm). Posteriormente, as amostras foram submetidas a um processo de lixamento e polimento e examinadas em microscópio óptico por reflexão com aumento de 50x a 100x. Para a análise e processamento digital das imagens, foi utilizado o sistema de imagens Axio Vision 4.6 para Windows, sendo obtidas as medidas para cada área observada em micrômetros (μm); uma da área da cavidade, e outra da área de material obturador. Foi aferido o grau de circularidade de cada amostra, por uma fórmula matemática utilizada automaticamente pelo programa, onde 1 (um) é considerado o círculo perfeito e, quanto mais achatado o canal, mais tendente a 0 (zero) nesta escala. Obteve-se a área do canal, a circularidade de 0 a 1, a área preenchida pelo material obturador e, a porcentagem da área de preenchimento do material obturador em relação à área do canal. Foi realizado o cruzamento dos grupos dois a dois pelo teste t de Student, sendo verificada diferença estatisticamente significante entre os grupos GP3 e R3, tendo o grupo R3 apresentado maior porcentagem de área do canal radicular preenchida pelo material obturador em suas amostras (p<0,05). Na relação da circularidade com a quantidade de preenchimento, com o teste de Correlação de Pearson, não foi observada forte correlação entre a forma final do canal (relação de circularidade) e a quantidade de preenchimento do canal radicular pelos materiais obturadores testados. Conclui-se que houve grande variação de preenchimento mínimo e máximo em todos os grupos testados e o Resilon apresentou maior porcentagem de preenchimento de área do canal radicular em suas amostras.