999 resultados para small watersheds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microstructures of hydrogenated microcrystalline silicon (tic-Si: H) thin films, prepared by plasma-enhanced chemical vapor deposition (PECVD), hot wire CVD(HWCVD) and plasma assisted HWCVD (PE-HWCVD), have been analyzed by the small angle x-ray scattering(SAXS) measurement. The SAXS data show that the microstructures of the μ c-Si: H films display different characteristics for different deposition techniques. For films deposited by PECVD, the volume fraction of micro-voids and mean size are smaller than those in HWCVD sample. Aided by suitable ion-bombardment, PE-HWCVD samples show a more compact structure than the HWCVD sample. The microstructure parameters of the μ c-Si: H thin films deposited by two-steps HWCVD and PE-HWCVD with Ar ions are evidently improved. The result of 45° tilting SAXS measurement indicates that the distribution of micro-voids in the film is anisotropic. The Fouriertransform infrared spectra confirm the SAXS data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An extended subtraction method of scattering parameters for characterizing laser diode is proposed in this paper. The intrinsic response is extracted from the measured transmission coefficients of laser diode, and the parasitics of packaging net-work laser chip are determined from the measured reflection coefficient of laser diode simultaneously. It is shown that the theories agree well with the experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of plasmonic very-small-aperture lasers is demonstrated in this letter. It is an integration of the surface plasmon structures and very-small-aperture lasers (VSAL). The experimental and numerical results demonstrate that the transmission field can be confined to a spot with subwavelength width in the far field, and the power output can be enhanced 140% of the normal VSAL. Such a device can be useful in the application of a high resolution far-field scanning optical microscope. (C) 2007 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the pulsed injection method is extended to measure the chip temperature of various packaged laser modules, such as the DFB laser modules, the FP laser modules, and the EML laser modules. An optimal injection condition is obtained by investigating the dependence of the lasing wavelength on the width and period of the injection pulse in a relatively wide temperature range. The small-signal frequency responses and large-signal performances of packaged laser modules at different chip temperature are measured. The adiabatic small-signal modulation characteristics of packaged LD are first extracted. In the large-signal measurement, the effects of chip temperature, bias current and driving signal on the performances of the laser modules are discussed. It has been found that the large-signal performances of the EML modules depend on the different red-shift speeds of the DFB and EAM sections as chip temperature varying, and the optimal characteristics may be achieved at higher temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose and demonstrate measurement of the frequency response of an electroabsorption (EA) modulator using an extended small-signal power measuring technique. In this technique, the modulator is driven by a microwave carrier amplitude modulated by a low-frequency signal, and the modulator frequency response is obtained without the need of a high-speed photodetector. Based upon the nonlinear characteristics of the EA modulator and the underlying principle of the present method, equations have been derived. A measurement scheme using a network analyzer and a low-speed photodetector has been proposed and constructed, and the experimental results confirm that our proposed method is as accurate as the swept-frequency measurement using a network analyzer directly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on biomimetic pattern recognition theory, we proposed a novel speaker-independent continuous speech keyword-spotting algorithm. Without endpoint detection and division, we can get the minimum distance curve between continuous speech samples and every keyword-training net through the dynamic searching to the feature-extracted continuous speech. Then we can count the number of the keywords by investigating the vale-value and the numbers of the vales in the curve. Experiments of small vocabulary continuous speech with various speaking rate have got good recognition results and proved the validity of the algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a resonant tunneling diode (RTD) small signal equivalent circuit model consisting of quantum capacitance and quantum inductance. The model is verified through the actual InAs/In0.53Ga0.47As/AlAs RTD fabricated on an InP substrate. Model parameters are extracted by fitting the equivalent circuit model with ac measurement data in three different regions of RTD current-voltage (I-V) characteristics. The electron lifetime, representing the average time that the carriers remain in the quasibound states during the tunneling process, is also calculated to be 2.09 ps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the enhancement of light transmission through a sub-wavelength aperture by oil- or solid-immersion is presented in this letter. An output power enhancement phenomenon related to the oil-immersion or solid-immersion mechanism is realized experimentally and reported for a very small aperture laser, which is an agreement with simulation analysis. This phenomenon could be useful for future optical data storage, microscopy and lithography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a theoretical and experimental research about applying a very-small-aperture laser (VSAL) to detect sub-wavelength data. Near-field distribution of a VSAL, which is essential for the application of such near-field devices, will be affected by the sample or fiber posited in the near-field region of the aperture. When the device is applied to detect the sub-wavelength data, the real resolution depends on the near-field spot size, the divergent angle of the beam and the distance from the aperture to the sample. Experimental results, including the near-field detection of the spot and detection of the sub-wavelength data by using the VSAL, are presented in this paper. We realize the two dimensional scanning about the sub-wavelength data (with the width 600 nm) by employing a VSAL with a 300 nm x 300 nm aperture.