997 resultados para hexaaquaaluminum(III) ion
Resumo:
BACKGROUND: NovoTTF is a portable device delivering low-intensity, intermediate-frequency, electric fields using noninvasive, disposable scalp electrodes. These fields physically interfere with cell division. Preliminary studies in recurrent and newly diagnosed glioblastoma (GBM) have shown promising results. A phase III study in recurrent GBM has recently been concluded. METHODS: Adults (KPS ≥ 70%) with recurrent GBM (any recurrence) were randomized (stratified by surgery and center) to either NovoTTF administered continuously (20-24 hours/day, 7 days/week) or the best available chemotherapy (best physician choice [BPC]). Primary endpoint was overall survival (OS); 6-month progression-free survival (PFS6), 1-year survival, and QOL were secondary endpoints. RESULTS: Two hundred thirty-seven patients were randomized (28 centers in the United States and Europe) to either NovoTTF alone (120 patients) or BPC (117 patients). Patient characteristics were balanced, median age was 54 years (range, 23-80 years), median KPS was 80% (range, 50-100). One quarter had surgery for recurrence, and over half were at their second or more recurrence. A survival advantage for the device group was seen in patients treated according to protocol (median OS, 7.8 months vs. 6.1 months; n = 185; p = 0.01). Moreover, subgroup analysis in patients with better prognostic baseline characteristics (KPS ≥ 80%; age ≤ 60; 1st-3rd recurrence) demonstrated a robust survival benefit for NovoTTF patients compared to matched BPC patients (median OS, 8.8 months vs. 6.6 months; n = 110; p < 0.01). In this group, 1-year survival was 35% vs. 20% and PFS6 was 25.6% vs. 7.7%. Interestingly, in patients who failed bevacizumab prior to the trial, OS was also significantly extended by NovoTTF (4.4 months vs. 3.1 months; n = 23 vs. n = 21; p < 0.02). Quality of life was equivalent or superior in NovoTTF patients. CONCLUSIONS: NovoTTF, a noninvasive, novel cancer treatment modality shows significant therapeutic efficacy with improved quality of life. The impact of NovoTTF was more pronounced when patients with better baseline prognostic factors were treated. A large scale phase III clinical trial in newly diagnosed GBM is currently being conducted.
Resumo:
There is increasing evidence that modular neck stems are prone to corrosion-related complications. Recent studies showed elevated metal ions levels and occasional pseudotumor formation in patients with such implants. The purpose of this study was to compare systemic metal-ion levels in patients after primary THA with modular neck stems to those of patients after non-modular implants. To our knowledge, this is the first cohort study including a control group, THA without CoCr heads and dry-assembled neck-stem connections. Methods: 50 patients after THA at a minimum follow-up of 1 year have been selected for the study. Patients with multiple prosthesis or other implants have been deselected. All received a cementless SPS stem from Symbios (Ti6Al4V). 40 patients have the modular neck (CoCr) version and 10 a monobloc version. All bearings were either ceramic-ceramic or ceramic-polyethylene to minimize other sources of CoCr ion release. In the modular group, the neck was chosen pre-operatively based on a 3D planning, allowing for a dry assembly of the stem and neck on the back table before implantation. A plasma system coupled to mass spectrometry was used for a complete elementary quantification in blood and serum separately. Clinical outcome was measured using the Oxford Hip Score. Results : Complete data sets of 29 patients (24 in the modular neck-group (10male, mean age 63y, 35-84y) and 5 in the monobloc-group (3 male, 69 y, 51-83y) are available to date. Mean Co blood levels were .95 ug/L (.14-12.4) in the modular group vs .27 ug/L (.10-.73) in the monobloc group (p=.2). Respective values for Cr were significantly higher in the modular group (.99 g/L; range .75-1.21) compared to those in the monobloc group (.74 g/L ;.62-.86; p=.001). No significant difference was found when comparing serum levels. 5/24 patients had Co levels above 1 g/L (12/24 for Cr), which is by some considered as a relevant elevation. The maximum Co level was measured in an asymptomatic patient. The Oxford Hip Scores were similar in both groups. Conclusion: Cr levels were significantly elevated in the modular neck group compared to those in the monobloc group. 1/24 patients with a modular prosthesis exhibited Co levels, which are beyond the threshold accepted even for metal-on-metal bearing couples. These results have contributed to our decision to abandon the use of modular neck stems. Routine follow-up including annual measurements of systemic CoCr concentrations should be considered.
Resumo:
A simple method using liquid chromatography-linear ion trap mass spectrometry for simultaneous determination of testosterone glucuronide (TG), testosterone sulfate (TS), epitestosterone glucuronide (EG) and epitestosterone sulfate (ES) in urine samples was developed. For validation purposes, a urine containing no detectable amount of TG, TS and EG was selected and fortified with steroid conjugate standards. Quantification was performed using deuterated testosterone conjugates to correct for ion suppression/enhancement during ESI. Assay validation was performed in terms of lower limit of detection (1-3ng/mL), recovery (89-101%), intraday precision (2.0-6.8%), interday precision (3.4-9.6%) and accuracy (101-103%). Application of the method to short-term stability testing of urine samples at temperature ranging from 4 to 37 degrees C during a time-storage of a week lead to the conclusion that addition of sodium azide (10mg/mL) is required for preservation of the analytes.
Resumo:
Heavy-ion reactions and other collective dynamical processes are frequently described by different theoretical approaches for the different stages of the process, like initial equilibration stage, intermediate locally equilibrated fluid dynamical stage, and final freeze-out stage. For the last stage, the best known is the Cooper-Frye description used to generate the phase space distribution of emitted, noninteracting particles from a fluid dynamical expansion or explosion, assuming a final ideal gas distribution, or (less frequently) an out-of-equilibrium distribution. In this work we do not want to replace the Cooper-Frye description, but rather clarify the ways of using it and how to choose the parameters of the distribution and, eventually, how to choose the form of the phase space distribution used in the Cooper-Frye formula. Moreover, the Cooper-Frye formula is used in connection with the freeze-out problem, while the discussion of transition between different stages of the collision is applicable to other transitions also. More recently, hadronization and molecular dynamics models have been matched to the end of a fluid dynamical stage to describe hadronization and freeze-out. The stages of the model description can be matched to each other on space-time hypersurfaces (just like through the frequently used freeze-out hypersurface). This work presents a generalized description of how to match the stages of the description of a reaction to each other, extending the methodology used at freeze-out, in simple covariant form which is easily applicable in its simplest version for most applications.