1000 resultados para Replica method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective is to reinforce the importance of blood reinfusion as a cheap, safe and simple method, which can be used in small hospitals, especially those in which there is no blood bank. Moreover, even with the use of devices that perform the collection and filtration of blood, more recent studies show that the cost-benefit ratio is much better when autologous transfusion is compared with blood transfusions, even when there is injury to hollow viscera and blood contamination. It is known that the allogeneic blood transfusion carries a number of risks to patients, among them are the coagulation disorders mediated by excess enzymes in the conserved blood, and deficiency in clotting factors, mainly the Factor V, the proacelerin. Another factor would be the risk of contamination with still unknown pathogens or that are not investigated during screening for selection of donors, such as the West Nile Fever and Creutzfeldt-Jacob, better known as "Mad Cow" disease. Comparing both methods, we conclude that blood autotransfusion has numerous advantages over heterologous transfusion, even in large hospitals. We are not against blood transfusions, just do not agree that the patient's own blood is discarded without making sure there will be enough blood in stock to get him out of the hemorrhagic shock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxidized starch is a key component in the paper industry, where it is used as both surfacing sizer and filler. Large quantities are annually used for this purpose; however, the methods for the oxidation are not environmentally friendly. In our research, we have studied the possibility to replace the harmful oxidation agents, such as hypochlorite or iodates and transition metal catalysts, with a more environmentally friendly oxidant, hydrogen peroxide (H2O2), and a special metal complex catalyst (FePcS), of which only a small amount is needed. The work comprised batch and semi-batch studies by H2O2, ultrasound studies of starch particles, determination of low-molecular by-products and determination of the decomposition kinetics of H2O2 in the presence of starch and the catalyst. This resulted in a waste-free oxidation method, which only produces water and oxygen as side products. The starch oxidation was studied in both semi-batch and batch modes in respective to the oxidant (H2O2) addition. The semi-batch mode proved to yield a sufficient degree of substitution (COOH groups) for industrial purposes. Treatment of starch granules by ultrasound was found to improve the reactivity of starch. The kinetic results were found out to have a rather complex pattern – several oxidation phases were observed, apparently due to the fact that the oxidation reaction in the beginning only took place on the surface, whereas after a prolonged reaction time, partial degradation of the solid starch granules allowed further reaction in the interior parts. Batch-mode experiments enabled a more detailed study of the mechanisms of starch in the presence of H2O2 and the catalyst, but yielded less oxidized starch due to rapid decomposition of H2O2 due to its high concentrations. The effect of the solid-liquid (S/L) ratio in the reaction system was studied in batch experiments. These studies revealed that the presence of the catalyst and the starch enhance the H2O2 decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lyhyet toimitusajat tuovat yrityksille kilpailuetua nopeasti muuttuvassa teollisuusympäristössä. Tämän diplomityön ensisijaisena tavoitteena on löytää kirjallisuuden avulla yrityksen käyttöön soveltuva menetelmä, joka soveltuu systemaattiseen läpimenoaikojen lyhentämiseen. Tärkeää on myös varmistaa valitun menetelmän soveltuvuus kohdeyrityksen ympäristöön. Työn toisena tavoitteena on ymmärtää, että minkälaisella panostuksella yhden päivän läpimenoaika voidaan saavuttaa. Kirjallisuustutkimuksen avulla on valittu tarkoitukseen sopiva toimintamalli. Menetelmä on testattu yhdellä tuotantolinjalla ja saadut tulokset sekä palaute osoittavat, että se näyttäisi soveltuvan kohdeyrityksen käyttöön. Tuotantolinjalle on tehty toimintasuunnitelma yhden päivän toimitusajan saavuttamiseksi vuoden 2013 aikana. Haasteen laajuutta koko kohdeyrityksessä on tutkittu erillisessä ideointisessiossa. Session tulosten perusteella on tehty prioriteettilista, joka antaa käsityksen toimitusajan merkittävän lyhentämisen vaatimuksista. Yleisesti ottaen kysynnän vaihtelun hallinta on suurin haaste, mutta useita ratkaisuvaihtoehtoja tämän hallitsemiseksi on tunnistettu.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to develop a crowdsourced videographic research method for consumer culture research. Videography provides opportunities for expressing contextual and culturally embedded relations. Thus, developing new ways to conduct videographic research is meaningful. This study develops the crowdsourced videographic method based on a literature review and evaluation of a focal study. The literature review follows a qualitative systematic review process. Through the literature review, based on different methodological, crowdsourcing and consumer research related literature, this study defines the method, its application process and evaluation criteria. Furthermore, the evaluation of the focal study, where the method was applied, completes the study. This study applies professional review with self-evaluation as a form of evaluation, drawing from secondary data including research task description, screenshots of the mobile application used in the focal study, videos collected from the participants, and self-evaluation by the author. The focal study is analyzed according to its suitability to consumer culture research, research process and quality. Definitions and descriptions of the research method, its process and quality criteria form the theoretical contribution of this study. Evaluating the focal study using these definitions underlines some best practices of this type of research, generating the practical contribution of this study. Finally, this study provides ideas for future research. First, defining the boundaries of the use of crowdsourcing in various parts of conducting research. Second, improving the method by applying it to new research contexts. Third, testing how changes in one dimension of the crowdsourcing models interact with other dimension. Fourth, comparing the quality criteria applied in this study to various other quality criteria to improve the method’s usefulness. Overall, this study represents a starting point for further development of the crowdsourced videographic research method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When modeling machines in their natural working environment collisions become a very important feature in terms of simulation accuracy. By expanding the simulation to include the operation environment, the need for a general collision model that is able to handle a wide variety of cases has become central in the development of simulation environments. With the addition of the operating environment the challenges for the collision modeling method also change. More simultaneous contacts with more objects occur in more complicated situations. This means that the real-time requirement becomes more difficult to meet. Common problems in current collision modeling methods include for example dependency on the geometry shape or mesh density, calculation need increasing exponentially in respect to the number of contacts, the lack of a proper friction model and failures due to certain configurations like closed kinematic loops. All these problems mean that the current modeling methods will fail in certain situations. A method that would not fail in any situation is not very realistic but improvements can be made over the current methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of tear sampling for protein quantification. Tear samples were collected from 29 healthy dogs (58 eyes) using Schirmer tear test (STT) strip and microcapillary tubes. The samples were frozen at -80ºC and analyzed by the Bradford method. Results were analyzed by Student's t test. The average protein concentration and standard deviation from tears collected with microcapillary tube were 4.45mg/mL ±0.35 and 4,52mg/mL ±0.29 for right and left eyes respectively. The average protein concentration and standard deviation from tears collected with Schirmer Tear Test (STT) strip were and 54.5mg/mL ±0.63 and 54.15mg/mL ±0.65 to right and left eyes respectively. Statistically significant differences (p<0.001) were found between the methods. In the conditions in which this study was conducted, the average protein concentration obtained with the Bradford test from tear samples obtained by Schirmer Tear Test (STT) strip showed values higher than those obtained with microcapillary tube. It is important that concentration of tear protein pattern values should be analyzed according the method used to collect tear samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrocardiography (ECG) QT interval is influenced by fluctuations in heart rate (HR) what may lead to misinterpretation of its length. Considering that alterations in QT interval length reflect abnormalities of the ventricular repolarisation which predispose to occurrence of arrhythmias, this variable must be properly evaluated. The aim of this work is to determine which method of correcting the QT interval is the most appropriate for dogs regarding different ranges of normal HR (different breeds). Healthy adult dogs (n=130; German Shepherd, Boxer, Pit Bull Terrier, and Poodle) were submitted to ECG examination and QT intervals were determined in triplicates from the bipolar limb II lead and corrected for the effects of HR through the application of three published formulae involving quadratic, cubic or linear regression. The mean corrected QT values (QTc) obtained using the diverse formulae were significantly different (ρ<0.05), while those derived according to the equation QTcV = QT + 0.087(1- RR) were the most consistent (linear regression). QTcV values were strongly correlated (r=0.83) with the QT interval and showed a coefficient of variation of 8.37% and a 95% confidence interval of 0.22-0.23 s. Owing to its simplicity and reliability, the QTcV was considered the most appropriate to be used for the correction of QT interval in dogs.