999 resultados para Perl`s method
Resumo:
The theoretical research of the study focused to business process management and business process modeling, the goal was to found a new business process modeling method for electrical accessories manufacturing enterprise. The focus was to find few options for business process modeling methods where company could have chosen the best one for its needs The study was carried out as a qualitative research with an action study and a case study as the most important ways collect data. In the empirical part of the study examples of company’s processes modeled with the new modeling method and process modeling process are presented. The new way of modeling processes improves especially visual presentation of the processes and improves the understanding how employees should work in the organizational interfaces of the process and in the interfaces between different processes. The results of the study is a new unified way to model company’s processes, which makes it easier to understand and create the process models. This improved readability makes it possible to reduce the costs that were created from the unclear old process models.
Resumo:
Capillary electrophoresis method designed originally for the analysis of monosaccharides was validated using reference solutions of polydatin. The validation was conducted by studying and determining the concentration levels of LOD and LOQ and the range of linearity and by determining levels of uncertainty in respect to repeatability and reproducibility. The reliability of the gained results is also discussed. A guide with recommendations considering the validation and overall design of analysis sequences with CE is also produced as a result of this study.
Resumo:
Real option valuation, in particular the fuzzy pay-off method, has proven to be useful in defining risk and visualizing imprecision of investments in various industry applications. This study examines whether the evaluation of risk and profitability for public real estate investments can be improved by using real option methodology. Firstly, the context of real option valuation in the real estate industry is examined. Further, an empirical case study is performed on 30 real estate investments of a Finnish government enterprise in order to determine whether the presently used investment analysis system can be complemented by the pay-off method. Despite challenges in the application of the pay-off method to the case company’s large investment base, real option valuation is found to create additional value and facilitate more robust risk analysis in public real estate applications.
Resumo:
Tool center point calibration is a known problem in industrial robotics. The major focus of academic research is to enhance the accuracy and repeatability of next generation robots. However, operators of currently available robots are working within the limits of the robot´s repeatability and require calibration methods suitable for these basic applications. This study was conducted in association with Stresstech Oy, which provides solutions for manufacturing quality control. Their sensor, based on the Barkhausen noise effect, requires accurate positioning. The accuracy requirement admits a tool center point calibration problem if measurements are executed with an industrial robot. Multiple possibilities are available in the market for automatic tool center point calibration. Manufacturers provide customized calibrators to most robot types and tools. With the handmade sensors and multiple robot types that Stresstech uses, this would require great deal of labor. This thesis introduces a calibration method that is suitable for all robots which have two digital input ports free. It functions with the traditional method of using a light barrier to detect the tool in the robot coordinate system. However, this method utilizes two parallel light barriers to simultaneously measure and detect the center axis of the tool. Rotations about two axes are defined with the center axis. The last rotation about the Z-axis is calculated for tools that have different width of X- and Y-axes. The results indicate that this method is suitable for calibrating the geometric tool center point of a Barkhausen noise sensor. In the repeatability tests, a standard deviation inside robot repeatability was acquired. The Barkhausen noise signal was also evaluated after recalibration and the results indicate correct calibration. However, future studies should be conducted using a more accurate manipulator, since the method employs the robot itself as a measuring device.
Resumo:
The objectives of the present study were 1) to compare results obtained by the traditional manual method of measuring heart rate (HR) and heart rate response (HRR) to the Valsalva maneuver, standing and deep breathing, with those obtained using a computerized data analysis system attached to a standard electrocardiograph machine; 2) to standardize the responses of healthy subjects to cardiovascular tests, and 3) to evaluate the response to these tests in a group of patients with diabetes mellitus (DM). In all subjects (97 healthy and 143 with DM) we evaluated HRR to deep breathing, HRR to standing, HRR to the Valsalva maneuver, and blood pressure response (BPR) to standing up and to a sustained handgrip. Since there was a strong positive correlation between the results obtained with the computerized method and the traditional method, we conclude that the new method can replace the traditional manual method for evaluating cardiovascular responses with the advantages of speed and objectivity. HRR and BPR of men and women did not differ. A correlation between age and HRR was observed for standing (r = -0.48, P<0.001) and deep breathing (r = -0.41, P<0.002). Abnormal BPR to standing was usually observed only in diabetic patients with definite and severe degrees of autonomic neuropathy.
Resumo:
Thirty-seven patients were submitted to kidney transplantation after transfusion at 2-week intervals with 4-week stored blood from their potential donors. All patients and donors were typed for HLA-A-B and DR antigens. The patients were also tested for cytotoxic antibodies against donor antigens before each transfusion. The percentage of panel reactive antibodies (PRA) was determined against a selected panel of 30 cell donors before and after the transfusions. The patients were immunosuppressed with azathioprine and prednisone. Rejection crises were treated with methylprednisolone. The control group consisted of 23 patients who received grafts from an unrelated donor but who did not receive donor-specific pretransplant blood transfusion. The incidence and reversibility of rejection episodes, allograft loss caused by rejection, and patient and graft survival rates were determined for both groups. Non-parametric methods (chi-square and Fisher tests) were used for statistical analysis, with the level of significance set at P<0.05. The incidence and reversibility of rejection crises during the first 60 post-transplant days did not differ significantly between groups. The actuarial graft and patient survival rates at five years were 56% and 77%, respectively, for the treated group and 39.8% and 57.5% for the control group. Graft loss due to rejection was significantly higher in the untreated group (P = 0.0026) which also required more intense immunosuppression (P = 0.0001). We conclude that tranfusions using stored blood have the immunosuppressive effect of fresh blood transfusions without the risk of provoking a widespread formation of antibodies. In addition, this method permits a reduction of the immunosuppressive drugs during the process without impairing the adequate functioning of the renal graft
Resumo:
In the present study, histopathological analysis of rat mesentery was used to quantify the effect of two anti-inflammatory agents, dexamethasone (Dex) and pertussis toxin (Ptx), on leukocyte migration. The intravenous injection of Dex (1 mg/kg) and Ptx (1,200 ng) 1 h prior to the intraperitoneal injection of the inflammatory stimuli lipopolysaccharide (LPS) or formyl-methionyl-leucyl-phenylalanine (fMLP) significantly reduced the neutrophil diapedesis (LPS: Ptx = 0.86 ± 0.19 and Dex = 0.35 ± 0.13 vs saline (S) = 2.85 ± 0.59; fMLP: Ptx = 0.43 ± 0.09 and Dex 0.01 ± 0.01 vs S = 1.08 ± 0.15 neutrophil diapedesis/field) and infiltration (LPS: Ptx = 6.29 ± 1.4 and Dex = 3.06 ± 0.76 vs S = 15.94 ± 3.97; fMLP: Ptx = 3.85 ± 0.56 and Dex = 0.40 ± 0.16 vs S = 7.15 ± 1.17 neutrophils/field) induced by the two agonists in the rat mesentery. The inhibitory effect of Dex and Ptx was clearly visible in the fields nearest the venule (up to 200 µm), demonstrating that these anti-inflammatory agents act preferentially in the transmigration of neutrophils from the vascular lumen into the interstitial space, but not in cell movement in response to a haptotactic gradient. The mesentery of rats pretreated with Dex showed a decreased number of neutrophils within the venules (LPS: Dex = 1.50 ± 0.38 vs S = 4.20 ± 1.01; fMLP: Dex = 0.25 ± 0.11 vs S = 2.20 ± 0.34 neutrophils in the lumen/field), suggesting that this inhibitor may be acting at a step that precedes neutrophil arrival in the inflamed tissue. In contrast to that observed with Dex treatment, the number of neutrophils found in mesenteric venules was significantly elevated in animals pretreated with Ptx (LPS: Ptx = 9.85 ± 2.25 vs S = 4.20 ± 1.01; fMLP: Ptx = 4.66 ± 1.24 vs S = 2.20 ± 0.34 neutrophils in the lumen/field). This discrepancy shows that Ptx and Dex act via different mechanisms and suggests that Ptx prevents locomotion of neutrophils from the vascular lumen to the interstitial space. In conclusion, the method described here is useful for quantifying the inflammatory and anti-inflammatory effect of different substances. The advantage of this histopathological approach is that it provides additional information about the steps involved in leucocyte migration.